-
Exploring the keV-scale physics potential of CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
A. Armatol,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (98 additional authors not shown)
Abstract:
We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among t…
▽ More
We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.
△ Less
Submitted 29 May, 2025;
originally announced May 2025.
-
First-ever detection of microseismic activity with a tonne-scale cryogenic experiment
Authors:
D. Q. Adams,
C. Alduino,
K. Alfonso,
A. Armatol,
F. T. Avignone,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
C. Capelli,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (105 additional authors not shown)
Abstract:
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations us…
▽ More
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0νββ$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0νββ$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.
△ Less
Submitted 13 May, 2025;
originally announced May 2025.
-
Innovating Bolometers' Mounting: A Gravity-Based Approach
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska,
J. Camilleri
, et al. (168 additional authors not shown)
Abstract:
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by grav…
▽ More
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of bolometers and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li$_2$MoO$_4$ crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than $\pm$0.5 mK at 10 mK, (ii) a good energy resolution of Li$_2$MoO$_4$ bolometers, (6.6 $\pm$ 2.2) keV FWHM at 2615 keV, and (iii) a Li$_2$MoO$_4$ light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.
△ Less
Submitted 6 March, 2025;
originally announced March 2025.
-
CUPID, the CUORE Upgrade with Particle IDentification
Authors:
The CUPID Collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
L. Benussi,
V. Berest,
M. Beretta,
L. Bergé,
M. Bettelli,
M. Biassoni,
J. Billard,
F. Boffelli,
V. Boldrini,
E. D. Brandani,
C. Brofferio,
C. Bucci,
M. Buchynska
, et al. (168 additional authors not shown)
Abstract:
CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo wit…
▽ More
CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{ββ}$) sensitivity of 9--15 meV, and a $3σ$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{ββ}$ range of 12--21 meV.
△ Less
Submitted 11 July, 2025; v1 submitted 1 March, 2025;
originally announced March 2025.
-
Simulation of the Background from $^{13}$C$(α, n)^{16}$O Reaction in the JUNO Scintillator
Authors:
JUNO Collaboration,
Thomas Adam,
Kai Adamowicz,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Fengpeng An,
Costas Andreopoulos,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Beretta,
Antonio Bergnoli,
Nikita Bessonov,
Daniel Bick,
Lukas Bieger,
Svetlana Biktemerova
, et al. (608 additional authors not shown)
Abstract:
Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($α, n$)…
▽ More
Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($α, n$) reactions. In organic liquid scintillator detectors, $α$ particles emitted from intrinsic contaminants such as $^{238}$U, $^{232}$Th, and $^{210}$Pb/$^{210}$Po, can be captured on $^{13}$C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ($α, n$) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $^{13}$C$(α, n)^{16}$O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.
△ Less
Submitted 2 May, 2025; v1 submitted 2 March, 2025;
originally announced March 2025.
-
Implementation of a high-efficiency muon veto system for the GeSparK alpha-beta/gamma coincidence detector
Authors:
A. Barresi,
D. Chiesa,
M. Nastasi,
E. Previtali,
M. Sisti
Abstract:
One of the main background sources of low background high purity germanium (HPGe) detectors is the cosmic muon showers produced in the interaction with the lead and copper shield surrounding the detector that can induce signals not distinguishable from radioactivity events. Plastic scintillators are widely used to implement active veto systems to reduce this contribution and increase the measureme…
▽ More
One of the main background sources of low background high purity germanium (HPGe) detectors is the cosmic muon showers produced in the interaction with the lead and copper shield surrounding the detector that can induce signals not distinguishable from radioactivity events. Plastic scintillators are widely used to implement active veto systems to reduce this contribution and increase the measurement sensitivity. In this work, we present the implementation of a high-efficiency muon veto system for the alpha-beta/gamma coincidence detector, called GeSparK. The veto system consists of six plastic scintillator detectors accurately positioned around the HPGe and liquid scintillator detectors. The final design includes two detectors above and four inside the passive shielding between the copper and lead layers. In this way, we could limit both their size and the event rate produced by external radioactivity. A dedicated background measurement showed that the achieved background reduction is a bit less than 93%.
△ Less
Submitted 17 February, 2025;
originally announced February 2025.
-
Fluorescence emission of the JUNO liquid scintillator
Authors:
M. Beretta,
F. Houria,
F. Ferraro,
D. Basilico,
A. Brigatti,
B. Caccianiga,
A. Caslini,
C. Landini,
P. Lombardi,
L. Pelicci,
E. Percalli,
G. Ranucci,
A. C. Re,
C. Clementi,
F. Ortica,
A. Romani,
V. Antonelli,
M. G. Giammarchi,
L. Miramonti,
P. Saggese,
M. D. C. Torri,
S. Aiello,
G. Andronico,
A. Barresi,
A. Bergnoli
, et al. (43 additional authors not shown)
Abstract:
JUNO is a huge neutrino detector that will use 20 kton of organic liquid scintillator as its detection medium. The scintillator is a mixture of linear alkyl benzene (LAB), 2.5 g/L of 2,5-diphenyloxazole (PPO) and 3 mg/L of 1,4-Bis(2-methylstyryl)benzene (Bis-MSB). The main goal of JUNO is to determine the Neutrino Mass Ordering [1, 2, 3]. In order to achieve this purpose, good energy and position…
▽ More
JUNO is a huge neutrino detector that will use 20 kton of organic liquid scintillator as its detection medium. The scintillator is a mixture of linear alkyl benzene (LAB), 2.5 g/L of 2,5-diphenyloxazole (PPO) and 3 mg/L of 1,4-Bis(2-methylstyryl)benzene (Bis-MSB). The main goal of JUNO is to determine the Neutrino Mass Ordering [1, 2, 3]. In order to achieve this purpose, good energy and position reconstruction is required, hence a complete understanding of the optical characteristics of the liquid scintillator is mandatory. In this paper we present the measurements on the JUNO scintillator emission spectrum, absorption length and fluorescence time distribution performed respectively with a spectrofluorimeter, a spectrophotometer and a custom made setup
△ Less
Submitted 9 March, 2025; v1 submitted 17 January, 2025;
originally announced January 2025.
-
Machine learning-assisted techniques for Compton-background discrimination in Broad Energy Germanium (BEGe) detector
Authors:
Giovanni Baccolo,
Andrea Barresi,
Davide Chiesa,
Andrea Giachero,
Danilo Labranca,
Roberto Moretti,
Massimiliano Nastasi,
Alessandro Paonessa,
Marco Picione,
Ezio Previtali,
Monica Sisti
Abstract:
High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad E…
▽ More
High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad Energy Germanium (BEGe TM) detectors. We introduce two machine learning models: an autoencoder-MLP (Multilayer Perceptron) and a Gaussian Mixture Model (GMM). These models differentiate single-site events (SSEs) from multi-site events (MSEs) and train on signal waveforms produced in the detector. The GMM method differs from previous machine learning efforts in that it is fully unsupervised, hence not requiring specific data labelling during the training phase. Being both label-free and simulation-agnostic makes the unsupervised approach particularly advantageous for tasks where realistic, high-fidelity labeling is challenging or where biases introduced by simulated data must be avoided. In our analysis, the full-energy Peak-to-Compton ratio of the 137-Cs, a radionuclide contained in a cryoconite sample, exhibits an improvement from 0.238 in the original spectrum to 0.547 after the ACM data filtering and 0.414 after the GMM data filtering, demonstrating the effectiveness of these methods. The results also showcase an enhancement in the signal-to-background ratio across many regions of interest, enabling the detection of lower concentrations of radionuclides.
△ Less
Submitted 11 December, 2024;
originally announced December 2024.
-
Radiopurity screening of materials for rare event searches by neutron activation at the TRIGA reactor of Pavia
Authors:
G. Baccolo,
A. Barresi,
D. Chiesa,
M. Nastasi,
E. Previtali,
M. Sisti
Abstract:
In the framework of physics experiments searching for rare events, the selection of extremely radiopure materials is a challenging task, as the signal of interest is often hidden by instrumental background. Neutron activation is a powerful technique to measure trace contaminants with high sensitivity but, to be properly applied, it requires a good characterization of neutron irradiation and $γ$-sp…
▽ More
In the framework of physics experiments searching for rare events, the selection of extremely radiopure materials is a challenging task, as the signal of interest is often hidden by instrumental background. Neutron activation is a powerful technique to measure trace contaminants with high sensitivity but, to be properly applied, it requires a good characterization of neutron irradiation and $γ$-spectroscopy facilities. This paper presents the state-of-the-art workflow adopted by the Radioactivity Laboratory of the University of Milano-Bicocca for radiopurity screening of materials by neutron activation performed at the TRIGA reactor in Pavia. The ultimate sensitivity of the described workflow, in the absence of interfering activation products and without the application of radiochemical and/or active background rejection techniques, is $<10^{-14}$ g/g for $^{40}$K, $<10^{-12}$ g/g for $^{238}$U and of the order of $10^{-12}$ g/g for $^{232}$Th contaminations. Further details are here provided to address systematic uncertainties related to neutron irradiation that may bias results. To this aim, a dedicated neutron activation campaign was performed and the data were analyzed exploiting a Monte Carlo simulation model of the reactor and applying an unfolding technique to obtain a comprehensive characterization of the neutron flux in typical irradiation configurations. The results of this work provide a valuable benchmark for the application of neutron activation in future radiopurity screening campaigns.
△ Less
Submitted 4 November, 2024;
originally announced November 2024.
-
Interpretable machine learning approach for electron antineutrino selection in a large liquid scintillator detector
Authors:
A. Gavrikov,
V. Cerrone,
A. Serafini,
R. Brugnera,
A. Garfagnini,
M. Grassi,
B. Jelmini,
L. Lastrucci,
S. Aiello,
G. Andronico,
V. Antonelli,
A. Barresi,
D. Basilico,
M. Beretta,
A. Bergnoli,
M. Borghesi,
A. Brigatti,
R. Bruno,
A. Budano,
B. Caccianiga,
A. Cammi,
R. Caruso,
D. Chiesa,
C. Clementi,
S. Dusini
, et al. (43 additional authors not shown)
Abstract:
Several neutrino detectors, KamLAND, Daya Bay, Double Chooz, RENO, and the forthcoming large-scale JUNO, rely on liquid scintillator to detect reactor antineutrino interactions. In this context, inverse beta decay represents the golden channel for antineutrino detection, providing a pair of correlated events, thus a strong experimental signature to distinguish the signal from a variety of backgrou…
▽ More
Several neutrino detectors, KamLAND, Daya Bay, Double Chooz, RENO, and the forthcoming large-scale JUNO, rely on liquid scintillator to detect reactor antineutrino interactions. In this context, inverse beta decay represents the golden channel for antineutrino detection, providing a pair of correlated events, thus a strong experimental signature to distinguish the signal from a variety of backgrounds. However, given the low cross-section of antineutrino interactions, the development of a powerful event selection algorithm becomes imperative to achieve effective discrimination between signal and backgrounds. In this study, we introduce a machine learning (ML) model to achieve this goal: a fully connected neural network as a powerful signal-background discriminator for a large liquid scintillator detector. We demonstrate, using the JUNO detector as an example, that, despite the already high efficiency of a cut-based approach, the presented ML model can further improve the overall event selection efficiency. Moreover, it allows for the retention of signal events at the detector edges that would otherwise be rejected because of the overwhelming amount of background events in that region. We also present the first interpretable analysis of the ML approach for event selection in reactor neutrino experiments. This method provides insights into the decision-making process of the model and offers valuable information for improving and updating traditional event selection approaches.
△ Less
Submitted 25 November, 2024; v1 submitted 9 June, 2024;
originally announced June 2024.
-
Search for fractionally charged particles with CUORE
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (95 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.
△ Less
Submitted 18 June, 2024;
originally announced June 2024.
-
Distillation and Stripping purification plants for JUNO liquid scintillator
Authors:
C. Landini,
M. Beretta,
P. Lombardi,
A. Brigatti,
M. Montuschi,
S. Parmeggiano,
G. Ranucci,
V. Antonelli,
D. Basilico,
B. Caccianiga,
M. G. Giammarchi,
L. Miramonti,
E. Percalli,
A. C. Re,
P. Saggese,
M. D. C. Torri,
S. Aiello,
G. Andronico,
A. Barresi,
A. Bergnoli,
M. Borghesi,
R. Brugnera,
R. Bruno,
A. Budano,
A. Cammi
, et al. (42 additional authors not shown)
Abstract:
The optical and radiochemical purification of the scintillating liquid, which will fill the central detector of the JUNO experiment, plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions and an unprecedented target value of about 3% @ 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation leng…
▽ More
The optical and radiochemical purification of the scintillating liquid, which will fill the central detector of the JUNO experiment, plays a crucial role in achieving its scientific goals. Given its gigantic mass and dimensions and an unprecedented target value of about 3% @ 1 MeV in energy resolution, JUNO has set severe requirements on the parameters of its scintillator, such as attenuation length (Lat>20 m at 430 nm), transparency, light yield, and content of radioactive contaminants (238U,232Th<10-15 g/g). To accomplish these needs, the scintillator will be processed using several purification methods, including distillation in partial vacuum and gas stripping, which are performed in two large scale plants installed at the JUNO site. In this paper, layout, operating principles, and technical aspects which have driven the design and construction of the distil- lation and gas stripping plants are reviewed. The distillation is effective in enhancing the optical properties and removing heavy radio-impurities (238U,232Th, 40K), while the stripping process exploits pure water steam and high-purity nitrogen to extract gaseous contaminants (222Rn, 39Ar, 85Kr, O2) from the scintillator. The plant operating parameters have been tuned during the recent com- missioning phase at the JUNO site and several QA/QC measurements and tests have been performed to evaluate the performances of the plants. Some preliminary results on the efficiency of these purification processes will be shown.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Refractive index in the JUNO liquid scintillator
Authors:
H. S. Zhang,
M. Beretta,
S. Cialdi,
C. X. Yang,
J. H. Huang,
F. Ferraro,
G. F. Cao,
G. Reina,
Z. Y. Deng,
E. Suerra,
S. Altilia,
V. Antonelli,
D. Basilico,
A. Brigatti,
B. Caccianiga,
M. G. Giammarchi,
C. Landini,
P. Lombardi,
L. Miramonti,
E. Percalli,
G. Ranucci,
A. C. Re,
P. Saggese,
M. D. C. Torri,
S. Aiello
, et al. (51 additional authors not shown)
Abstract:
In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for…
▽ More
In the field of rare event physics, it is common to have huge masses of organic liquid scintillator as detection medium. In particular, they are widely used to study neutrino properties or astrophysical neutrinos. Thanks to its safety properties (such as low toxicity and high flash point) and easy scalability, linear alkyl benzene is the most common solvent used to produce liquid scintillators for large mass experiments. The knowledge of the refractive index is a pivotal point to understand the detector response, as this quantity (and its wavelength dependence) affects the Cherenkov radiation and photon propagation in the medium. In this paper, we report the measurement of the refractive index of the JUNO liquid scintillator between 260-1064 nm performed with two different methods (an ellipsometer and a refractometer), with a sub percent level precision. In addition, we used an interferometer to measure the group velocity in the JUNO liquid scintillator and verify the expected value derived from the refractive index measurements.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Data-driven background model for the CUORE experiment
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
J. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi
, et al. (93 additional authors not shown)
Abstract:
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo…
▽ More
We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
Prediction of Energy Resolution in the JUNO Experiment
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Kai Adamowicz,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta,
Antonio Bergnoli,
Daniel Bick
, et al. (629 additional authors not shown)
Abstract:
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components o…
▽ More
This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3\% at 1~MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of study reveal an energy resolution of 2.95\% at 1~MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors.
△ Less
Submitted 9 January, 2025; v1 submitted 28 May, 2024;
originally announced May 2024.
-
Analysis of reactor burnup simulation uncertainties for antineutrino spectrum prediction
Authors:
A. Barresi,
M. Borghesi,
A. Cammi,
D. Chiesa,
L. Loi,
M. Nastasi,
E. Previtali,
M. Sisti,
S. Aiello,
G. Andronico,
V. Antonelli,
D. Basilico,
M. Beretta,
A. Bergnoli,
A. Brigatti,
R. Brugnera,
R. Bruno,
A. Budano,
B. Caccianiga,
V. Cerrone,
R. Caruso,
C. Clementi,
S. Dusini,
A. Fabbri,
G. Felici
, et al. (42 additional authors not shown)
Abstract:
Nuclear reactors are a source of electron antineutrinos due to the presence of unstable fission products that undergo $β^-$ decay. They will be exploited by the JUNO experiment to determine the neutrino mass ordering and to get very precise measurements of the neutrino oscillation parameters. This requires the reactor antineutrino spectrum to be characterized as precisely as possible both through…
▽ More
Nuclear reactors are a source of electron antineutrinos due to the presence of unstable fission products that undergo $β^-$ decay. They will be exploited by the JUNO experiment to determine the neutrino mass ordering and to get very precise measurements of the neutrino oscillation parameters. This requires the reactor antineutrino spectrum to be characterized as precisely as possible both through high resolution measurements, as foreseen by the TAO experiment, and detailed simulation models. In this paper we present a benchmark analysis utilizing Serpent Monte Carlo simulations in comparison with real pressurized water reactor spent fuel data. Our objective is to study the accuracy of fission fraction predictions as a function of different reactor simulation approximations. Then, utilizing the BetaShape software, we construct fissile antineutrino spectra using the summation method, thereby assessing the influence of simulation uncertainties on reactor antineutrino spectrum.
△ Less
Submitted 30 October, 2024; v1 submitted 21 November, 2023;
originally announced November 2023.
-
Array of Cryogenic Calorimeters to Evaluate the Spectral Shape of forbidden $β$-decays: the ACCESS project
Authors:
L. Pagnanini,
G. Benato,
P. Carniti,
E. Celi,
D. Chiesa,
J. Corbett,
I. Dafinei,
S. Di Domizio,
P. Di Stefano,
S. Ghislandi,
C. Gotti,
D. L. Helis,
R. Knobel,
J. Kostensalo,
J. Kotila,
S. Nagorny,
G. Pessina,
S. Pirro,
S. Pozzi,
A. Puiu,
S. Quitadamo,
M. Sisti,
J. Suhonen,
S. Kuznetsov
Abstract:
The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays, which can serve as an important benchmark for nuclear physics calculations and represent a significant background in astroparticle physics experiments. ACCESS will operate a pilot array of cryogenic calorimeters based on…
▽ More
The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays, which can serve as an important benchmark for nuclear physics calculations and represent a significant background in astroparticle physics experiments. ACCESS will operate a pilot array of cryogenic calorimeters based on natural and doped crystals containing \b{eta}-emitting radionuclides. In this way, natural (e.g. 113 Cd and 115In) and synthetic isotopes (e.g. 99Tc) will be simultaneously measured with a common experimental technique. The array will also include further crystals optimised to disentangle the different background sources, thus reducing the systematic uncertainty. In this paper, we give an overview of the ACCESS research program, discussing a detector design study and promising results of 115In.
△ Less
Submitted 3 May, 2023;
originally announced May 2023.
-
The background model of the CUPID-Mo $0νββ$ experiment
Authors:
CUPID-Mo Collaboration,
:,
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
E. Celi,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa
, et al. (58 additional authors not shown)
Abstract:
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform…
▽ More
CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation $0νββ$ decay experiment, CUPID. It consisted of an array of 20 enriched Li$_{2}$$ ^{100}$MoO$_4$ bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the $2νββ$ decay and other processes with high precision. We also measure the radio-purity of the Li$_{2}$$^{100}$MoO$_4$ crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7$^{+0.9}_{-0.8}$(stat)$^{+1.5}_{-0.7}$(syst)$\times10^{-3}$counts/$Δ$E$_{FWHM}$/mol$_{iso}$/yr, the lowest in a bolometric $0νββ$ decay experiment.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics
Authors:
Riccardo Triozzi,
Andrea Serafini,
Marco Bellato,
Antonio Bergnoli,
Matteo Bolognesi,
Riccardo Brugnera,
Vanessa Cerrone,
Chao Chen,
Barbara Clerbaux,
Alberto Coppi,
Daniele Corti,
Flavio dal Corso,
Jianmeng Dong,
Wei Dou,
Lei Fan,
Alberto Garfagnini,
Arsenii Gavrikov,
Guanghua Gong,
Marco Grassi,
Rosa Maria Guizzetti,
Shuang Hang,
Cong He,
Jun Hu,
Roberto Isocrate,
Beatrice Jelmini
, et al. (107 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the exp…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the experiment is an unprecedented 3% energy resolution, guaranteed by its large active mass (20 kton) and the use of more than 20,000 20-inch photo-multiplier tubes (PMTs) acquired by high-speed, high-resolution sampling electronics located very close to the PMTs. As the Front-End and Read-Out electronics is expected to continuously run underwater for 30 years, a reliable readout acquisition system capable of handling the timestamped data stream coming from the Large-PMTs and permitting to simultaneously monitor and operate remotely the inaccessible electronics had to be developed. In this contribution, the firmware and hardware implementation of the IPbus based readout protocol will be presented, together with the performances measured on final modules during the mass production of the electronics.
△ Less
Submitted 20 February, 2023;
originally announced February 2023.
-
Mass testing of the JUNO experiment 20-inch PMTs readout electronics
Authors:
Alberto Coppi,
Beatrice Jelmini,
Marco Bellato,
Antonio Bergnoli,
Matteo Bolognesi,
Riccardo Brugnera,
Vanessa Cerrone,
Chao Chen,
Barbara Clerbaux,
Daniele Corti,
Flavio dal Corso,
Jianmeng Dong,
Wei Dou,
Lei Fan,
Alberto Garfagnini,
Arsenii Gavrikov,
Guanghua Gong,
Marco Grassi,
Rosa Maria Guizzetti,
Shuang Hang,
Cong He,
Jun Hu,
Roberto Isocrate,
Xiaolu Ji,
Xiaoshan Jiang
, et al. (107 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test pro…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test protocol for the 20-inch PMT underwater readout electronics, performed in parallel to the mass production line. In a time period of about ten months, a total number of 6950 electronic boards were tested with an acceptance yield of 99.1%.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
Validation and integration tests of the JUNO 20-inch PMTs readout electronics
Authors:
Vanessa Cerrone,
Katharina von Sturm,
Marco Bellato,
Antonio Bergnoli,
Matteo Bolognesi,
Riccardo Brugnera,
Chao Chen,
Barbara Clerbaux,
Alberto Coppi,
Flavio dal Corso,
Daniele Corti,
Jianmeng Dong,
Wei Dou,
Lei Fan,
Alberto Garfagnini,
Guanghua Gong,
Marco Grassi,
Shuang Hang,
Rosa Maria Guizzetti,
Cong He,
Jun Hu,
Roberto Isocrate,
Beatrice Jelmini,
Xiaolu Ji,
Xiaoshan Jiang
, et al. (105 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. JUNO will be able to study the neutrino mass ordering and to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range, spanning from 200 keV to several GeV. Given the ambitious physics goals of JUNO, the electronic system has to meet specific tight requirements, and a thorough characterization is required. The present paper describes the tests performed on the readout modules to measure their performances.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
F. De Dominics,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (23 additional authors not shown)
Abstract:
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last…
▽ More
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Beretta,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
C. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali
, et al. (96 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
△ Less
Submitted 28 July, 2022; v1 submitted 9 May, 2022;
originally announced May 2022.
-
Final results on the $0νββ$ decay half-life limit of $^{100}$Mo from the CUPID-Mo experiment
Authors:
C. Augier,
A. S. Barabash,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
J. Billard,
Yu. A. Borovlev,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
D. Chiesa,
I. Dafinei,
F. A. Danevich,
M. De Jesus,
P. de Marcillac,
T. Dixon,
L. Dumoulin,
K. Eitel,
F. Ferri,
B. K. Fujikawa,
J. Gascon,
L. Gironi,
A. Giuliani
, et al. (54 additional authors not shown)
Abstract:
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20…
▽ More
The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20 mK. We present here the final analysis with the full exposure of CUPID-Mo ($^{100}$Mo exposure of 1.47 kg$\times$yr) used to search for lepton number violation via 0$νββ$ decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $^{100}$Mo 0$νββ$ decay half-life of $T^{0ν}_{1/2} > 1.8 \times 10^{24}$ year (stat.+syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $\left<m_{ββ}\right> < (0.28$--$0.49)$ eV, dependent upon the nuclear matrix element utilized.
△ Less
Submitted 11 December, 2022; v1 submitted 17 February, 2022;
originally announced February 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
Measurements of neutron fields in a wide energy range using multi-foil activation analysis
Authors:
D. Chiesa,
C. Cazzaniga,
M. Nastasi,
M. Rebai,
C. D. Frost,
G. Gorini,
S. Lilley,
S. Pozzi,
E. Previtali
Abstract:
An accurate characterization of the neutron fields at spallation sources is crucial for many applications based on neutron irradiations, such as radiation damage tests that need a precise dose estimate. In this work we present the neutron flux measurements performed with the multi-foil activation technique in the ROTAX and ChipIr beamlines of the ISIS spallation source, characterized by moderated…
▽ More
An accurate characterization of the neutron fields at spallation sources is crucial for many applications based on neutron irradiations, such as radiation damage tests that need a precise dose estimate. In this work we present the neutron flux measurements performed with the multi-foil activation technique in the ROTAX and ChipIr beamlines of the ISIS spallation source, characterized by moderated and unmoderated spectra, respectively. We selected many different activation reactions to cover a wide energy range, from thermal to very fast neutrons up to about 100 MeV. By applying a Bayesian unfolding algorithm, we demonstrate the effectiveness of this technique in measuring the neutron flux intensity and energy spectrum with precision and accuracy.
△ Less
Submitted 15 March, 2022; v1 submitted 11 October, 2021;
originally announced October 2021.
-
CUORE Opens the Door to Tonne-scale Cryogenics Experiments
Authors:
CUORE Collaboration,
D. Q. Adams,
C. Alduino,
F. Alessandria,
K. Alfonso,
E. Andreotti,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
M. Barucci,
J. W. Beeman,
F. Bellini,
G. Benato,
M. Beretta,
A. Bersani,
D. Biare,
M. Biassoni,
F. Bragazzi,
A. Branca,
C. Brofferio,
A. Bryant,
A. Buccheri
, et al. (184 additional authors not shown)
Abstract:
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve…
▽ More
The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.
△ Less
Submitted 2 December, 2021; v1 submitted 17 August, 2021;
originally announced August 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Background identification in cryogenic calorimeters through $α-α$ delayed coincidences
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel,
M. Martinez
, et al. (20 additional authors not shown)
Abstract:
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to inv…
▽ More
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $α-α$ delayed coincidences in $^{232}$Th and $^{238}$U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $α$ decay position.
△ Less
Submitted 13 August, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Measurement of $^{216}$Po half-life with the CUPID-0 experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
V. Caracciolo,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (22 additional authors not shown)
Abstract:
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited ex…
▽ More
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.
△ Less
Submitted 12 May, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Improving radioactive contaminant identification through the analysis of delayed coincidences with an $α$-spectrometer
Authors:
G. Baccolo,
A. Barresi,
M. Beretta,
D. Chiesa,
M. Nastasi,
L. Pagnanini,
S. Pozzi,
E. Previtali,
M. Sisti,
G. Terragni
Abstract:
In the framework of rare event searches, the identification of radioactive contaminants in ultra-pure samples is a challenging task, because the signal is often at the same level of the instrumental background. This is a rather common situation for $α$-spectrometers and other detectors used for low-activity measurements. In order to obtain the target sensitivity without extending the data taking l…
▽ More
In the framework of rare event searches, the identification of radioactive contaminants in ultra-pure samples is a challenging task, because the signal is often at the same level of the instrumental background. This is a rather common situation for $α$-spectrometers and other detectors used for low-activity measurements. In order to obtain the target sensitivity without extending the data taking live-time, analysis strategies that highlight the presence of the signal sought should be developed. In this paper, we show how to improve the contaminant tagging capability relying on the time-correlation of radioactive decay sequences. We validate the proposed technique by measuring the impurity level of both contaminated and ultra-pure copper samples, demonstrating the potential of this analysis tool in disentangling different background sources and providing an effective way to mitigate their impact in rare event searches.
△ Less
Submitted 9 November, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Search for double $β$-decay modes of $^{64}$Zn using purified zinc
Authors:
F. Bellini,
M. Beretta,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
Yu. V. Gorbenko,
C. Gotti,
G. P. Kovtun,
M. Laubenstein,
S. Nagorny,
S. Nisi,
L. Pagnanini,
L. Pattavina,
G. Pessina,
S. Pirro,
E. Previtali,
C. Rusconi,
K. Schaffner
, et al. (5 additional authors not shown)
Abstract:
The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the L…
▽ More
The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the Laboratori Nazionali del Gran Sasso. The total activity of cosmogenic activated nuclides is measured at the level of a few mBq/kg, as well as limits on naturally occurring radionuclides are set to less than mBq/kg. The excellent radiopurity of the zinc sample allows us to search for electron capture with positron emission and neutrinoless double electron capture of $^{64}$Zn, setting the currently most stringent lower limits on their half-lives, $T_{1/2}^{\varepsilonβ^+} > 2.7 \times 10^{21}\text{yr}$ (90% C.I.), and $T_{1/2}^{0\nu2\varepsilon}> 2.6 \times 10^{21}\text{yr}$ (90% C.I.), respectively.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
New results from the CUORE experiment
Authors:
A. Giachero,
D. Q. Adams,
C. Alduino,
K. Alfonso,
F. T. Avignone III,
O. Azzolini,
G. Bari,
F. Bellini,
G. Benato,
M. Biassoni,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Caminata,
A. Campani,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa
, et al. (88 additional authors not shown)
Abstract:
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion…
▽ More
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.
△ Less
Submitted 7 January, 2021; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Search for Neutrino-less Double Beta Decay of $^{64}$Zn and $^{70}$Zn with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
E. Celi,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
O. Cremomesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti,
G. Keppel
, et al. (21 additional authors not shown)
Abstract:
CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of…
▽ More
CUPID-0 is the first pilot experiment of CUPID, a next-generation project searching for neutrino-less double beta decay. In its first scientific run, CUPID-0 operated 26 ZnSe cryogenic calorimeters coupled to light detectors in the underground Laboratori Nazionali del Gran Sasso. In this work, we analyzed a ZnSe exposure of 11.34 kg$\times$yr to search for the neutrino-less double beta decay of $^{70}$Zn and for the neutrino-less positron-emitting electron capture of $^{64}$Zn. We found no evidence for these decays and set 90$\%$ credible interval limits of ${\rm T}_{1/2}^{0νββ}(^{70}{\rm Zn}) > 1.6 \times 10^{21}$ yr and ${\rm T}_{1/2}^{0νEC β+}(^{64}{\rm Zn}) > 1.2 \times 10^{22}$ yr, surpassing by almost two orders of magnitude the previous experimental results
△ Less
Submitted 15 September, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
Embedded Readout Electronics R&D for the Large PMTs in the JUNO Experiment
Authors:
M. Bellato,
A. Bergnoli,
A. Brugnera,
S. Chen,
Z. Chen,
B. Clerbaux,
F. dal Corso,
D. Corti,
J. Dong,
G. Galet,
A. Garfagnini,
A. Giaz,
G. Gong,
C. Grewing,
J. Hu,
R. Isocrate,
X. Jiang,
F. Li,
I. Lippi,
F. Marini,
Z. Ning,
A. G. Olshevskiyi,
D. Pedretti,
P. A. Petitjean,
M. Robens
, et al. (69 additional authors not shown)
Abstract:
Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high…
▽ More
Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high speed, high resolution sampling electronics located very close to the detector signal. Linearity in the response of the electronics in another important ingredient for the success of the experiment. During the initial design phase of the electronics, a custom design, with the Front-End and Read-Out electronics located very close to the detector analog signal has been developed and successfully tested. The present paper describes the electronics structure and the first tests performed on the prototypes. The electronics prototypes have been tested and they show good linearity response, with a maximum deviation of 1.3% over the full dynamic range (1-1000 p.e.), fulfilling the JUNO experiment requirements.
△ Less
Submitted 17 May, 2020; v1 submitted 18 March, 2020;
originally announced March 2020.