Development of a picosecond-timing Cherenkov detector using gaseous photomultiplification
Authors:
R. Okubo,
K. Matsuoka,
T. Iijima,
K. Inami,
Y. Horii,
K. Suzuki,
K. Sumi,
T. Ichikawa,
K. Ueda,
S. Koji,
A. Kondo,
K. Chiba
Abstract:
Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a gaseous photomultiplier (GasPM) and demonstrated that a single-photon time resolution is $25\pm1.1~\rm{ps}$ at the gain of $3.3\times10^6$ with a $\rm {LaB_6}$ pho…
▽ More
Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a gaseous photomultiplier (GasPM) and demonstrated that a single-photon time resolution is $25\pm1.1~\rm{ps}$ at the gain of $3.3\times10^6$ with a $\rm {LaB_6}$ photocathode, which has an extremely low quantum efficiency. We then developed a Cherenkov detector using GasPM with a $\rm{CsI}$ photocathode aiming for an application in time-of-flight measurements with a resolution below 10~$\rm{ps}$ for particle identification. We performed a test using the 3 GeV electron beam at the PF-AR test beamline located at KEK, Japan. As a result, the resolution of time-of-flight between the detector and an MCP-PMT is measured to be $σ=73.0\pm2.4~\rm{ps}$. The obtained resolution is worse than the target because of the lower gap voltage compared to the design. However, it is consistent with the expectation from the applied gap voltage. It is an important milestone for achieving the designed resolution by increasing the gap voltage and photon detection efficiency in future development.
△ Less
Submitted 24 February, 2025;
originally announced February 2025.
Development of a method to measure trace level of uranium and thorium in scintillation films
Authors:
K. Ichimura,
K. Chiba,
Y. Gando,
H. Ikeda,
Y. Kishimoto,
M. Kurasawa,
K. Nemoto,
A. Sakaguchi,
Y. Takaku,
Y. Sakakieda
Abstract:
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, in…
▽ More
We have established a method to measure picograms-per-gram (pg g$^{-1}$) levels of $^{238}$U and $^{232}$Th in scintillation films by combining the dry ashing method and inductively coupled plasma mass spectrometry. Trace amounts of $^{238}$U and $^{232}$Th were measured in up to 2~g of the scintillation film with almost 100% collection efficiency. This paper details the experimental procedure, including the pretreatment of the samples and labware, detection limit of the method, collection efficiencies of $^{238}$U and $^{232}$Th, and measurement of $^{238}$U and $^{232}$Th in a polyethylene naphthalate film. This method is also applicable to $^{238}$U and $^{232}$Th measurements in other low-background organic materials for rare event search experiments.
△ Less
Submitted 8 May, 2024;
originally announced May 2024.