Calibration and sensitivity of the Virgo detector during its second science run
Authors:
The Virgo Collaboration,
T. Accadia,
F. Acernese,
F. Antonucci,
P. Astone,
G. Ballardin,
F. Barone,
M. Barsuglia,
A. Basti,
Th. S. Bauer,
M. G. Beker,
A. Belletoile,
S. Birindelli,
M. Bitossi,
M. A. Bizouard,
M. Blom,
F. Bondu,
L. Bonelli,
R. Bonnand,
V. Boschi,
L. Bosi,
B. Bouhou,
S. Braccini,
C. Bradaschia,
A. Brillet
, et al. (153 additional authors not shown)
Abstract:
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to…
▽ More
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.
△ Less
Submitted 18 January, 2011; v1 submitted 27 September, 2010;
originally announced September 2010.
Off-resonant Raman transitions impact in an atom interferometer
Authors:
A. Gauguet,
Tanja Mehlstäubler,
Thomas Lévèque,
J. Le Gouët,
Oualid Chaibi,
B. Canuel,
Andre Clairon,
Franck Pereira Dos Santos,
Arnaud Landragin
Abstract:
We study the influence of off-resonant two photon transitions on high precision measurements with atom interferometers based on stimulated Raman transitions. These resonances induce a two photon light shift on the resonant Raman condition. The impact of this effect is investigated in two highly sensitive experiments: a gravimeter and a gyroscope-accelerometer. We show that it can lead to signifi…
▽ More
We study the influence of off-resonant two photon transitions on high precision measurements with atom interferometers based on stimulated Raman transitions. These resonances induce a two photon light shift on the resonant Raman condition. The impact of this effect is investigated in two highly sensitive experiments: a gravimeter and a gyroscope-accelerometer. We show that it can lead to significant systematic phase shifts, which have to be taken into account in order to achieve best performances in term of accuracy and stability.
△ Less
Submitted 31 August, 2008;
originally announced September 2008.