-
Investigation of the Carbon Monoxide Dication Lifetime Using (CO)$_2$ Dimer Fragmentation
Authors:
A. Méry,
X. Fléchard,
S. Guillous,
V. Kumar,
M. Lalande,
J. Rangama,
W. Wolff,
A. Cassimi
Abstract:
The fragmentation of carbon monoxide dimers induced by collisions with low energy Ar$^{9+}$ ions is investigated using the COLTRIMS technique. The presence of a neighbor molecule in the dimer serves here as a diagnostic tool to probe the lifetimes of the $\rm CO^{2+}$ molecular dications resulting from the collision. The existence of metastable states with lifetimes ranging from 2~ps to 200~ns is…
▽ More
The fragmentation of carbon monoxide dimers induced by collisions with low energy Ar$^{9+}$ ions is investigated using the COLTRIMS technique. The presence of a neighbor molecule in the dimer serves here as a diagnostic tool to probe the lifetimes of the $\rm CO^{2+}$ molecular dications resulting from the collision. The existence of metastable states with lifetimes ranging from 2~ps to 200~ns is clearly evidenced experimentally through a sequential 3-body fragmentation of the dimer, whereas fast dissociation channels are observed in a so-called concerted 3-body fragmentation process. The fast fragmentation process leads to a kinetic energy release distribution also observed in collisions with monomer CO targets. This is found in contradiction with the conclusions of a former study attributing this fast process to the perturbation induced by the neighbor molecular ion.
△ Less
Submitted 7 October, 2021; v1 submitted 19 July, 2021;
originally announced July 2021.
-
Coulomb explosion imaging of carbon monoxide dimers
Authors:
A. Méry,
V. Kumar,
X. Fléchard,
B. Gervais,
S. Guillous,
M. Lalande,
J. Rangama,
W. Wolff,
A. Cassimi
Abstract:
We report on experimental results obtained from collisions of slow highly charged Ar9+ ions with a carbon monoxide dimer (CO)2 target. A COLTRIMS setup and a Coulomb explosion imaging approach are used to reconstruct the structure of the CO dimers. The three dimensional structure is deduced from the 2-body and 3-body dissociation channels from which both the intermolecular bond length and the rela…
▽ More
We report on experimental results obtained from collisions of slow highly charged Ar9+ ions with a carbon monoxide dimer (CO)2 target. A COLTRIMS setup and a Coulomb explosion imaging approach are used to reconstruct the structure of the CO dimers. The three dimensional structure is deduced from the 2-body and 3-body dissociation channels from which both the intermolecular bond length and the relative orientation of the two molecules are determined. For the 3-body channels, the experimental data are interpreted with the help of a classical model in which the trajectories of the three emitted fragments are numerically integrated. We measured the equilibrium intermolecular distance to be Re = 4.2 A. The orientation of both CO molecules with respect to the dimer axis is found to be quasi-isotropic due to the large vibrational temperature of the gas jet.
△ Less
Submitted 29 April, 2021;
originally announced April 2021.
-
A Coulomb Over-the-Barrier Monte Carlo Simulation to probe Ion-Dimer Collision Dynamics
Authors:
W. Iskandar,
X. Fléchard,
J. Matsumoto,
A. Leredde,
S. Guillous,
D. Hennecart,
J. Rangama,
A. Méry,
B. Gervais,
H. Shiromaru,
A. Cassimi
Abstract:
We present a combined theoretical and experimental study of primary and post-collision mechanisms involved when colliding low energy multiply charged ions with van der Waals dimers. The collision dynamics is investigated using a classical calculation based on the Coulombic Over-the- Barrier Model adapted to rare-gas dimer targets. Despite its simplicity, the model predictions are found in very goo…
▽ More
We present a combined theoretical and experimental study of primary and post-collision mechanisms involved when colliding low energy multiply charged ions with van der Waals dimers. The collision dynamics is investigated using a classical calculation based on the Coulombic Over-the- Barrier Model adapted to rare-gas dimer targets. Despite its simplicity, the model predictions are found in very good agreement with experimental results obtained using COLd Target Recoil Ion Momentum Spectroscopy (COLTRIMS), both for the relative yields of the different relaxation processes and for the associated transverse momentum exchange distributions between the projectile and the target. This agreement shows to which extent van der Waals dimers can be assimilated to independent atoms.
△ Less
Submitted 12 April, 2018;
originally announced April 2018.
-
Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL
Authors:
G. Boissonnat,
J. -M. Fontbonne,
E. Balanzat,
F. Boumard,
B. Carniol,
A. Cassimi,
J. Colin,
D. Cussol,
D. Etasse,
C. Fontbonne,
A. -M. Frelin,
J. Hommet,
J. Peronnel,
S. Salvador
Abstract:
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sa…
▽ More
Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.
△ Less
Submitted 15 September, 2016; v1 submitted 22 July, 2016;
originally announced July 2016.
-
Interatomic Coulombic Decay as a New Source of Low Energy Electrons in slow Ion-Dimer Collisions
Authors:
W. Iskandar,
J. Matsumoto,
A. Leredde,
X. Flechard,
B. Gervais,
S. Guillous,
D. Hennecart,
A. Mery,
J. Rangama,
C. L. Zhou,
H. Shiromaru,
A. Cassimi
Abstract:
We provide the experimental evidence that the single electron capture process in slow collisions between O$^{3+}$ ions and neon dimer targets leads to an unexpected production of low-energy electrons. This production results from the interatomic Coulombic decay process, subsequent to inner shell single electron capture from one site of the neon dimer. Although pure one-electron capture from inner…
▽ More
We provide the experimental evidence that the single electron capture process in slow collisions between O$^{3+}$ ions and neon dimer targets leads to an unexpected production of low-energy electrons. This production results from the interatomic Coulombic decay process, subsequent to inner shell single electron capture from one site of the neon dimer. Although pure one-electron capture from inner shell is expected to be negligible in the low collision energy regime investigated here, the electron production due to this process overtakes by one order of magnitude the emission of Auger electrons by the scattered projectiles after double-electron capture. This feature is specific to low charge states of the projectile: similar studies with Xe$^{20+}$ and Ar$^{9+}$ projectiles show no evidence of inner shell single-electron capture. The dependence of the process on the projectile charge state is interpreted using simple calculations based on the classical over the barrier model.
△ Less
Submitted 3 November, 2014;
originally announced November 2014.
-
Ion impact induced Interatomic Coulombic Decay in neon and argon dimers
Authors:
H. -K. Kim,
H. Gassert,
M. S. Schöffler,
J. N. Titze,
M. Waitz,
J. Voigtsberger,
F. Trinter,
J. Becht,
A. Kalinin,
N. Neumann,
C. Zhou,
L. Ph. H. Schmidt,
O. Jagutzki,
A. Czasch,
H. Merabet,
H. Schmidt-Böcking,
T. Jahnke,
A. Cassimi,
R. Dörner
Abstract:
We investigate the contribution of Interatomic Coulombic Decay induced by ion impact in neon and argon dimers (Ne$_2$ and Ar$_2$) to the production of low energy electrons. Our experiments cover a broad range of perturbation strengths and reaction channels. We use 11.37 MeV/u S$^{14+}$, 0.125 MeV/u He$^{1+}$, 0.1625 MeV/u He$^{1+}$ and 0.150 MeV/u He$^{2+}$ as projectiles and study ionization, sin…
▽ More
We investigate the contribution of Interatomic Coulombic Decay induced by ion impact in neon and argon dimers (Ne$_2$ and Ar$_2$) to the production of low energy electrons. Our experiments cover a broad range of perturbation strengths and reaction channels. We use 11.37 MeV/u S$^{14+}$, 0.125 MeV/u He$^{1+}$, 0.1625 MeV/u He$^{1+}$ and 0.150 MeV/u He$^{2+}$ as projectiles and study ionization, single and double electron transfer to the projectile as well as projectile electron loss processes. The application of a COLTRIMS reaction microscope enables us to retrieve the three-dimensional momentum vectors of the ion pairs of the fragmenting dimer into Ne$^{q+}$/Ne$^{1+}$ and Ar$^{q+}$/Ar$^{1+}$ (q = 1, 2, 3) in coincidence with at least one emitted electron.
△ Less
Submitted 31 October, 2013;
originally announced October 2013.
-
High resolution probe of coherence in low-energy charge exchange collisions with oriented targets
Authors:
A. Leredde,
X. Fléchard,
A. Cassimi,
D. Hennecart,
B. Pons
Abstract:
The trapping lasers of a magneto-optical trap (MOT) are used to bring Rb atoms into well defined oriented states. Coupled to recoil-ion momentum spectroscopy (RIMS), this yields a unique MOTRIMS setup which is able to probe scattering dynamics, including their coherence features, with unprecedented resolution. This technique is applied to the low-energy charge exchange processes Na$^+$+Rb(…
▽ More
The trapping lasers of a magneto-optical trap (MOT) are used to bring Rb atoms into well defined oriented states. Coupled to recoil-ion momentum spectroscopy (RIMS), this yields a unique MOTRIMS setup which is able to probe scattering dynamics, including their coherence features, with unprecedented resolution. This technique is applied to the low-energy charge exchange processes Na$^+$+Rb($5p_{\pm 1}$) $\rightarrow$ Na($3p,4s$)+Rb$^+$. The measurements reveal detailed features of the collisional interaction which are employed to improve the theoretical description. All of this enables to gauge the reliability of intuitive pictures predicting the most likely capture transitions.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.
-
SPORT: A new sub-nanosecond time-resolved instrument to study swift heavy ion-beam induced luminescence - Application to luminescence degradation of a fast plastic scintillator
Authors:
E. Gardés,
E. Balanzat,
B. Ban-d'Etat,
A. Cassimi,
F. Durantel,
C. Grygiel,
T. Madi,
I. Monnet,
J. -M. Ramillon,
F. Ropars,
H. Lebius
Abstract:
We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/μm. As a consequence of increasing permanent radiation damages with increasin…
▽ More
We developed a new sub-nanosecond time-resolved instrument to study the dynamics of UV-visible luminescence under high stopping power heavy ion irradiation. We applied our instrument, called SPORT, on a fast plastic scintillator (BC-400) irradiated with 27-MeV Ar ions having high mean electronic stopping power of 2.6 MeV/μm. As a consequence of increasing permanent radiation damages with increasing ion fluence, our investigations reveal a degradation of scintillation intensity together with, thanks to the time-resolved measurement, a decrease in the decay constant of the scintillator. This combination indicates that luminescence degradation processes by both dynamic and static quenching, the latter mechanism being predominant. Under such high density excitation, the scintillation deterioration of BC-400 is significantly enhanced compared to that observed in previous investigations, mainly performed using light ions. The observed non-linear behaviour implies that the dose at which luminescence starts deteriorating is not independent on particles' stopping power, thus illustrating that the radiation hardness of plastic scintillators can be strongly weakened under high excitation density in heavy ion environments.
△ Less
Submitted 23 January, 2013;
originally announced January 2013.