-
A Four-channel Optically Pumped Magnetometer for a Magnetoencephalography Sensor Array
Authors:
Joonas Iivanainen,
Tony R. Carter,
Jonathan E. Dhombridge,
Timothy S. Read,
Kaleb Campbell,
Quinn Abate,
David M. Ridley,
Amir Borna,
Peter D. D. Schwindt
Abstract:
We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical pow…
▽ More
We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.
△ Less
Submitted 22 December, 2023;
originally announced December 2023.
-
Bind-and-bend model for DNA looping
Authors:
Michael Liaofan Liu,
Daniel W. Oo,
Ryan B. McMillan,
Ashley R. Carter
Abstract:
DNA looping is important in DNA condensation and regulation. One method for forming a DNA loop, thought to be used by the condensing agent protamine, is bind-and-bend. In bind-and-bend, molecules bind all along the DNA, each creating a bend in the DNA. Eventually, enough bending leads to the formation of a loop. Here, we adapt theory for DNA bending by cations to create a simple bind-and-bend mode…
▽ More
DNA looping is important in DNA condensation and regulation. One method for forming a DNA loop, thought to be used by the condensing agent protamine, is bind-and-bend. In bind-and-bend, molecules bind all along the DNA, each creating a bend in the DNA. Eventually, enough bending leads to the formation of a loop. Here, we adapt theory for DNA bending by cations to create a simple bind-and-bend model. To test the model, we simulate bending and looping by the condensing agent protamine and compare the output of the simulation to experimental data. The model captures several interesting features of the data including: the curvature of the DNA due to both protamine-induced bending and thermal fluctuations, the small circumference of the loops (200-300 bp), the bias in the location where the loop forms, and the emergence of multi-looped flower structures. The model leads to insight into where protamine binds, how it bends DNA, and how it creates one or more DNA loops. More broadly, the model could be useful in understanding the compaction of nucleic acids or polyelectrolytes.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Calibration and localization of optically pumped magnetometers using electromagnetic coils
Authors:
Joonas Iivanainen,
Amir Borna,
Rasmus Zetter,
Tony R. Carter,
Julia M. Stephen,
Jim McKay,
Lauri Parkkonen,
Samu Taulu,
Peter D. D. Schwindt
Abstract:
In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer a…
▽ More
In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer and model these discreetly sampled fields using vector-spherical harmonics (VSH) functions. We then localize and calibrate a sensor by minimizing the sum of squared errors between the model signals and the sensor responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. By determining the coil currents based on the VSH models, the coil fields can approximate these low-order field components, yielding computationally simple initial estimates of the sensor parameters. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2° and 0.8%, respectively. Last, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
DNA toroids form via a flower intermediate
Authors:
Ryan B. McMillan,
Hilary Bediako,
Luka M. Devenica,
Yuxing E. Ma,
Donna M. Roscoe,
Ashley R. Carter
Abstract:
DNA in sperm cells must undergo an extreme compaction to almost crystalline packing levels. To produce this dense packing, DNA is condensed by protamine, a positively charged protein that loops the DNA into a toroid. Our goal is to determine the pathway and mechanism for toroid formation. We first imaged short-length (L=217-1023 nm) DNA molecules in 0-5.0 $μ$M protamine using an atomic force micro…
▽ More
DNA in sperm cells must undergo an extreme compaction to almost crystalline packing levels. To produce this dense packing, DNA is condensed by protamine, a positively charged protein that loops the DNA into a toroid. Our goal is to determine the pathway and mechanism for toroid formation. We first imaged short-length (L=217-1023 nm) DNA molecules in 0-5.0 $μ$M protamine using an atomic force microscope (AFM). At low protamine concentrations (0.2-0.6 $μ$M), molecules dramatically condensed, folding into a flower structure. Dynamic folding measurements of the DNA using a tethered particle motion (TPM) assay revealed a corresponding, initial folding event, which was >3 loops at L=398 nm. The initial folding event was made up of smaller (<1 loop) events that had similar dynamics as protamine-induced bending. This suggests that flowers form in an initial step as protamine binds and bends the DNA. It was not until higher protamine concentrations (>2 $μ$M) that DNA in the AFM assay formed small (<10 loop), vertically packed toroids. Taken together, these results lead us to propose a nucleation-growth model of toroid formation that includes a flower intermediate. This pathway is important in both in vivo DNA condensation and in vitro engineering of DNA nanostructures.
△ Less
Submitted 13 January, 2021;
originally announced January 2021.
-
Non-Invasive Functional-Brain-Imaging with a Novel Magnetoencephalography System
Authors:
Amir Borna,
Tony R. Carter,
Anthony P. Colombo,
Yuan-Yu Jau,
Jim McKay,
Michael Weisend,
Samu Taulu,
Julia M. Stephen,
Peter D. D. Schwindt
Abstract:
A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. Due to proximity (12 mm) of the OPM channels to the brain, it is anticipated that this MEG system offers an enhanced spatial resolution as it can capture finer spatial features compar…
▽ More
A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. Due to proximity (12 mm) of the OPM channels to the brain, it is anticipated that this MEG system offers an enhanced spatial resolution as it can capture finer spatial features compared to traditional MEG systems employing superconducting quantum interference device (SQUID). We have conducted two MEG experiments on three subjects: somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial SQUID-based MEG system. We have cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects.
△ Less
Submitted 6 December, 2018;
originally announced December 2018.
-
A 20-Channel Magnetoencephalography System Based on Optically Pumped Magnetometers
Authors:
Amir Borna,
Tony R. Carter,
Anthony P. Colombo,
Yuan-Yu Jau,
Christopher Berry,
Jim McKay,
Julia Stephen,
Michael Weisend,
Peter D. D. Schwindt
Abstract:
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquis…
▽ More
We describe a multichannel magnetoencephalography (MEG) system that uses optically pumped magnetometers (OPMs) to sense the magnetic fields of the human brain. The system consists of an array of 20 OPM channels conforming to the human subject's head, a person-sized magnetic shield containing the array and the human subject, a laser system to drive the OPM array, and various control and data acquisitions systems. We conducted two MEG experiments: auditory evoked magnetic field (AEF) and somatosensory evoked magnetic field (SEF), on three healthy male subjects, using both our OPM array and a 306-channel Elekta-Neuromag superconducting quantum interference device (SQUID) MEG system. The described OPM array measures the tangential components of the magnetic field as opposed to the radial component measured by all SQUID-based MEG systems. Herein we compare the results of the OPM- and SQUID-based MEG systems on the auditory and somatosensory data recorded in the same individuals on both systems.
△ Less
Submitted 19 June, 2017;
originally announced June 2017.
-
Biophysical Measurements of Cells, Microtubules, and DNA with an Atomic Force Microscope
Authors:
Luka M. Devenica,
Clay Contee,
Raysa Cabrejo,
Matthew Kurek,
Edward F. Deveney,
Ashley R. Carter
Abstract:
Atomic force microscopes (AFMs) are ubiquitous in research laboratories and have recently been priced for use in teaching laboratories. Here we review several AFM platforms (Dimension 3000 by Digital Instruments, EasyScan2 by Nanosurf, ezAFM by Nanomagnetics, and TKAFM by Thorlabs) and describe various biophysical experiments that could be done in the teaching laboratory using these instruments. I…
▽ More
Atomic force microscopes (AFMs) are ubiquitous in research laboratories and have recently been priced for use in teaching laboratories. Here we review several AFM platforms (Dimension 3000 by Digital Instruments, EasyScan2 by Nanosurf, ezAFM by Nanomagnetics, and TKAFM by Thorlabs) and describe various biophysical experiments that could be done in the teaching laboratory using these instruments. In particular, we focus on experiments that image biological materials and quantify biophysical parameters: 1) imaging cells to determine membrane tension, 2) imaging microtubules to determine their persistence length, 3) imaging the random walk of DNA molecules to determine their contour length, and 4) imaging stretched DNA molecules to measure the tensional force.
△ Less
Submitted 15 December, 2015;
originally announced December 2015.
-
Radio-frequency power generation
Authors:
Richard G. Carter
Abstract:
This paper reviews the main types of radio-frequency power amplifiers which are, or may be, used for high-power hadron accelerators. It covers tetrodes, inductive output tubes, klystrons and magnetrons with power outputs greater than 10 kW continuous wave or 100 kW pulsed at frequencies from 50 MHz to 30 GHz. Factors affecting the satisfactory operation of amplifiers include cooling, matching and…
▽ More
This paper reviews the main types of radio-frequency power amplifiers which are, or may be, used for high-power hadron accelerators. It covers tetrodes, inductive output tubes, klystrons and magnetrons with power outputs greater than 10 kW continuous wave or 100 kW pulsed at frequencies from 50 MHz to 30 GHz. Factors affecting the satisfactory operation of amplifiers include cooling, matching and protection circuits are discussed. The paper concludes with a summary of the state of the art for the different technologies.
△ Less
Submitted 6 March, 2013;
originally announced March 2013.
-
arXiv:1302.4541
[pdf]
cond-mat.mtrl-sci
cond-mat.mes-hall
cond-mat.soft
physics.bio-ph
physics.chem-ph
Electrochemical Deposition of ZnO Hierarchical Nanostructures from Hydrogel Coated Electrodes
Authors:
Shuxi Dai,
Yinyong Li,
Zuliang Du,
Kenneth R. Carter
Abstract:
The electrochemical deposition of ZnO hierarchical nanostructures directly from PHEMA hydrogel coated electrodes has been successfully demonstrated. A variety of hierarchical ZnO nanostructures, including porous nanoflakes, nanosheets and nanopillar arrays were fabricated directly from the PHEMA hydrogel coated electrodes. Hybrid ZnO-hydrogel composite films were formed with low zinc concentration…
▽ More
The electrochemical deposition of ZnO hierarchical nanostructures directly from PHEMA hydrogel coated electrodes has been successfully demonstrated. A variety of hierarchical ZnO nanostructures, including porous nanoflakes, nanosheets and nanopillar arrays were fabricated directly from the PHEMA hydrogel coated electrodes. Hybrid ZnO-hydrogel composite films were formed with low zinc concentration and short electrodeposition time. A dual-layer structure consisting of a ZnO/polymer and pure ZnO layer was obtained with zinc concentration above 0.01 M. SEM observations and XPS depth profiling were used to investigate ZnO nanostructure formation in the early electrodeposition process. A growth mechanism to understand the formation of ZnO/hydrogel hybrid hierarchical nanostructures was developed. The I-V characteristics of the ZnO-hydrogel composite films in dark and under ultraviolet (UV) illumination demonstrate potential applications in UV photodetection.
△ Less
Submitted 19 February, 2013;
originally announced February 2013.
-
Spatial Modulation Microscopy for Real-Time Imaging of Plasmonic Nanoparticles and Cells
Authors:
N. Fairbairn,
R. A. Light,
R. Carter,
R. Fernandes,
A. G. Kanaras,
T. J. Elliott,
M. G. Somekh,
M. C. Pitter,
O. L. Muskens
Abstract:
Spatial modulation microscopy is a technique originally developed for quantitative spectroscopy of individual nano-objects. Here, a parallel implementation of the spatial modulation microscopy technique is demonstrated based on a line detector capable of demodulation at kHz frequencies. The capabilities of the imaging system are shown using an array of plasmonic nanoantennas and dendritic cells in…
▽ More
Spatial modulation microscopy is a technique originally developed for quantitative spectroscopy of individual nano-objects. Here, a parallel implementation of the spatial modulation microscopy technique is demonstrated based on a line detector capable of demodulation at kHz frequencies. The capabilities of the imaging system are shown using an array of plasmonic nanoantennas and dendritic cells incubated with gold nanoparticles.
△ Less
Submitted 27 March, 2012;
originally announced March 2012.
-
RF power generation
Authors:
R. G. Carter
Abstract:
This paper reviews the main types of r.f. power amplifiers which are, or may be, used for particle accelerators. It covers solid-state devices, tetrodes, inductive output tubes, klystrons, magnetrons, and gyrotrons with power outputs greater than 10 kW c.w. or 100 kW pulsed at frequencies from 50 MHz to 30 GHz. Factors affecting the satisfactory operation of amplifiers include cooling, matching an…
▽ More
This paper reviews the main types of r.f. power amplifiers which are, or may be, used for particle accelerators. It covers solid-state devices, tetrodes, inductive output tubes, klystrons, magnetrons, and gyrotrons with power outputs greater than 10 kW c.w. or 100 kW pulsed at frequencies from 50 MHz to 30 GHz. Factors affecting the satisfactory operation of amplifiers include cooling, matching and protection circuits are discussed. The paper concludes with a summary of the state of the art for the different technologies.
△ Less
Submitted 14 December, 2011;
originally announced December 2011.
-
Integration of fluorescence collection optics with a microfabricated surface electrode ion trap
Authors:
Gregory R. Brady,
A. Robert Ellis,
David L. Moehring,
Daniel Stick,
Clark Highstrete,
Kevin M. Fortier,
Matthew G. Blain,
Raymond A. Haltli,
Alvaro A. Cruz-Cabrera,
Ronald D. Briggs,
Joel R. Wendt,
Tony R. Carter,
Sally Samora,
Shanalyn A. Kemme
Abstract:
We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion-trapping chip without negatively impacting trapping performance. Epoxies, vacuum feedthrough, and optical component materials were care…
▽ More
We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion-trapping chip without negatively impacting trapping performance. Epoxies, vacuum feedthrough, and optical component materials were carefully chosen so that they did not degrade the vacuum environment, and we have demonstrated light detection as well as ion trapping and shuttling behavior comparable to trapping chips without integrated optics, with no modification to the control voltages of the trapping chip.
△ Less
Submitted 23 September, 2010; v1 submitted 17 August, 2010;
originally announced August 2010.
-
Wakefield damping for the CLIC crab cavity
Authors:
P. K. Ambattu,
G. Burt,
A. C. Dexter,
R. G. Carter,
V. Khan,
R. M. Jones,
V. Dolgashev
Abstract:
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole ki…
▽ More
A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole kicks demand very high damping of the inter-bunch wakes, the major contributor to the luminosity loss of colliding bunches. This paper investigates the nature of the wakefields in the CLIC crab cavity and the possibility of using various damping schemes to suppress them effectively.
△ Less
Submitted 19 June, 2009;
originally announced June 2009.
-
Crab cavities for linear colliders
Authors:
G. Burt,
P. Ambattu,
R. Carter,
A. Dexter,
I. Tahir,
C. Beard,
M. Dykes,
P. Goudket,
A. Kalinin,
L. Ma,
P. McIntosh,
D. Shulte,
R. M. Jones,
L. Bellantoni,
B. Chase,
M. Church,
T. Khabouline,
A. Latina,
C. Adolphsen,
Z. Li,
A. Seryei,
L. Xiao
Abstract:
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity…
▽ More
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.
△ Less
Submitted 16 October, 2008;
originally announced October 2008.
-
Initial study on the shape optimisation of the CLIC crab cavity
Authors:
P. K. Ambattu,
G. Burt,
R. G. Carter,
A. C. Dexter,
R. M. Jones,
P. McIntosh
Abstract:
The compact linear collider (CLIC) requires a crab cavity to align bunches prior to collision. The bunch structure demands tight amplitude and phase tolerances of the RF fields inside the cavity, for the minimal luminosity loss. Beam loading effects require special attention as it is one potential sources of field errors in the cavity. In order to assist the amplitude and phase control, we propo…
▽ More
The compact linear collider (CLIC) requires a crab cavity to align bunches prior to collision. The bunch structure demands tight amplitude and phase tolerances of the RF fields inside the cavity, for the minimal luminosity loss. Beam loading effects require special attention as it is one potential sources of field errors in the cavity. In order to assist the amplitude and phase control, we propose a travelling wave (TW) structure with a high group velocity allowing rapid propagation of errors out of the system. Such a design makes the cavity structure significantly different from previous ones. This paper will look at the implications of this on other cavity parameters and the optimisation of the cavity geometry.
△ Less
Submitted 16 October, 2008;
originally announced October 2008.