-
Electron beam characterization via fluorescence imaging of Rydberg states in atomic vapor
Authors:
Rob Behary,
Kevin Su,
Nicolas DeStefano,
Mykhailo Vorobiov,
T. Averett,
Alexandre Camsonne,
Shukui Zhang,
Charlie Fancher,
Neel Malvania,
Eugeniy Mikhailov,
Seth Aubin,
Irina Novikova
Abstract:
We demonstrate an all-optical, minimally invasive method for electron beam (e-beam) characterization using Rydberg electrometry. The e-beam passes through a dilute Rb vapor prepared in a quantum superposition of ground and Rydberg states that reduces resonant absorption in a narrow spectral region. Imaging the modifications of Rb fluorescence due to shifts in the Rydberg state from the e-beam elec…
▽ More
We demonstrate an all-optical, minimally invasive method for electron beam (e-beam) characterization using Rydberg electrometry. The e-beam passes through a dilute Rb vapor prepared in a quantum superposition of ground and Rydberg states that reduces resonant absorption in a narrow spectral region. Imaging the modifications of Rb fluorescence due to shifts in the Rydberg state from the e-beam electric field allows us to reconstruct e-beam width, centroid position, and current. We experimentally demonstrate this technique using a 20 keV e-beam in the range of currents down to 20 $μ$A, and discuss technical challenges produced by environmental electric potentials in the detection chamber. Overall, we demonstrate the promising potential of such an approach as a minimally invasive diagnostic for charged particle beams.
△ Less
Submitted 29 April, 2025;
originally announced April 2025.
-
Electron Beam Characterization via Quantum Coherent Optical Magnetometry
Authors:
Nicolas DeStefano,
Saeed Pegahan,
Aneesh Ramaswamy,
Seth Aubin,
T. Averett,
Alexandre Camsonne,
Svetlana Malinovskaya,
Eugeniy E. Mikhailov,
Gunn Park,
Shukui Zhang,
Irina Novikova
Abstract:
We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we r…
▽ More
We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin's quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size and total current. We tested this method for an e-beam with currents ranging from 30 to 110 μA. Our approach is insensitive to electron kinetic energy, and we confirmed that experimentally between 10 to 20 keV. This technique offers a unique platform for non-invasive characterization of charged particle beams used in accelerators for particle and nuclear physics research.
△ Less
Submitted 3 December, 2024;
originally announced December 2024.
-
Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors
Authors:
J. Xie,
C. Peng,
S. Joosten,
Z. -E. Meziani,
A. Camsonne,
M. Jones,
S. Malace,
E. Kaczanowicz,
M. Rehfuss,
N. Sparveris,
M. Paolone,
M. Foley,
M. Minot,
M. Popecki,
Z. W. Zhao
Abstract:
The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Ph…
▽ More
The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD$^{\rm TM}$) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab).
The results of this test confirmed that the coarse-pixelated (2.5$\times$2.5 cm$^2$ pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.
△ Less
Submitted 3 July, 2024; v1 submitted 1 February, 2024;
originally announced February 2024.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV
Authors:
John Arrington,
Jay Benesch,
Alexandre Camsonne,
Jimmy Caylor,
Jian-Ping Chen,
Silviu Covrig Dusa,
Alexander Emmert,
George Evans,
Haiyan Gao,
J. Ole Hansen,
Garth M. Huber,
Sylvester Joosten,
Vladimir Khachatryan,
Nilanga Liyanage,
Zein-Eddine Meziani,
Michael Nycz,
Chao Peng,
Michael Paolone,
Whit Seay,
Paul A. Souder,
Nikos Sparveris,
Hubert Spiesberger,
Ye Tian,
Eric Voutier,
Junqi Xie
, et al. (6 additional authors not shown)
Abstract:
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit…
▽ More
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3-D momentum space from Semi-Inclusive Deep Inelastic Scattering (SIDIS), expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS (PVDIS), a precision measurement of $J/ψ$ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.
△ Less
Submitted 12 February, 2023; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Performance of photosensors in a high-rate environment for gas Cherenkov detectors
Authors:
Chao Peng,
Junqi Xie,
Sylvester Joosten,
Zein-Eddine Meziani,
Alexandre Camsonne,
Mark Jones,
Edward Kaczanowicz,
Melanie Rehfuss,
Nikolaos Sparveris,
Michael Paolone,
Michael Foley,
Michael Minot,
Mark Popecki
Abstract:
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the…
▽ More
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm$^2$ at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small telescopic Cherenkov device in a high-rate environment up to 60 kHz/cm$^2$, in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the experimental performance of our telescopic device.
△ Less
Submitted 3 May, 2022; v1 submitted 23 November, 2020;
originally announced November 2020.
-
Production of highly-polarized positrons using polarized electrons at MeV energies
Authors:
D. Abbott,
P. Adderley,
A. Adeyemi,
P. Aguilera,
M. Ali,
H. Areti,
M. Baylac,
J. Benesch,
G. Bosson,
B. Cade,
A. Camsonne,
L. S. Cardman,
J. Clark,
P. Cole,
S. Covert,
C. Cuevas,
O. Dadoun,
D. Dale,
H. Dong,
J. Dumas,
E. Fanchini,
T. Forest,
E. Forman,
A. Freyberger,
E. Froidefond
, et al. (40 additional authors not shown)
Abstract:
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an…
▽ More
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.
△ Less
Submitted 28 June, 2016;
originally announced June 2016.
-
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
Authors:
A. Rakhman,
M. Hafez,
S. Nanda,
F. Benmokhtar,
A. Camsonne,
G. D. Cates,
M. M. Dalton,
G. B. Franklin,
M. Friend,
R. W. Michaels,
V. Nelyubin,
D. S. Parno,
K. D. Paschke,
B. P. Quinn,
P. A. Souder,
W. A. Tobias
Abstract:
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maxi…
▽ More
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO$_{3}$ crystal. The maximum achieved green power at 5 W IR pump power is 1.74 W with a total conversion efficiency of 34.8\%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7~kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7\%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0\% precision in polarization measurements of an electron beam with energy and current of 1.0~GeV and 50~$μ$A.
△ Less
Submitted 29 March, 2016; v1 submitted 3 January, 2016;
originally announced January 2016.
-
Beam Position Reconstruction for the g2p Experiment in Hall A at Jefferson Lab
Authors:
Pengjia Zhu,
Kalyan Allada,
Trent Allison,
Toby Badman,
Alexandre Camsonne,
Jian-ping Chen,
Melissa Cummings,
Chao Gu,
Min Huang,
Jie Liu,
John Musson,
Karl Slifer,
Vincent Sulkosky,
Yunxiu Ye,
Jixie Zhang,
Ryan Zielinski
Abstract:
Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast r…
▽ More
Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. Before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. The calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.
△ Less
Submitted 11 September, 2015;
originally announced September 2015.
-
MEIC Design Summary
Authors:
S. Abeyratne,
D. Barber,
A. Bogacz,
P. Brindza,
Y. Cai,
A. Camsonne,
A. Castilla,
P. Chevtsov,
E. Daly,
Y. S. Derbenev,
D. Douglas,
V. Dudnikov,
R. Ent,
B. Erdelyi,
Y. Filatov,
D. Gaskell,
J. Grames,
J. Guo,
L. Harwood,
A. Hutton,
C. Hyde,
K. Jordan,
A. Kimber,
G. A. Krafft,
A. Kondratenko
, et al. (30 additional authors not shown)
Abstract:
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current infor…
▽ More
This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current information.
△ Less
Submitted 29 April, 2015;
originally announced April 2015.
-
Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector
Authors:
D. S. Parno,
M. Friend,
V. Mamyan,
F. Benmokhtar,
A. Camsonne,
G. B. Franklin,
K. Paschke,
B. Quinn
Abstract:
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the…
▽ More
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.
△ Less
Submitted 24 May, 2013; v1 submitted 15 November, 2012;
originally announced November 2012.
-
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Authors:
M. Friend,
D. Parno,
F. Benmokhtar,
A. Camsonne,
M. Dalton,
G. B. Franklin,
V. Mamyan,
R. Michaels,
S. Nanda,
V. Nelyubin,
K. Paschke,
B. Quinn,
A. Rakhman,
P. Souder,
A. Tobias
Abstract:
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crysta…
▽ More
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped GSO crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
△ Less
Submitted 24 August, 2011; v1 submitted 15 August, 2011;
originally announced August 2011.