UCGretina GEANT4 Simulation of the GRETINA Gamma-Ray Energy Tracking Array
Authors:
L. A. Riley,
D. Weisshaar,
H. L. Crawford,
M. L. Agiorgousis,
C. M. Campbell,
M. Cromaz,
P. Fallon,
A. Gade,
S. D. Gregory,
E. B. Haldeman,
L. R. Jarvis,
E. D. Lawson-John,
B. Roberts,
B. V. Sadler,
C. G. Stine
Abstract:
UCGretina, a GEANT4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton co…
▽ More
UCGretina, a GEANT4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at $v/c \gtrsim 0.3$ at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. We adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.
△ Less
Submitted 17 April, 2021;
originally announced April 2021.
-
ADC Nonlinearity Correction for the MAJORANA DEMONSTRATOR
Authors:
N. Abgrall,
J. M. Allmond,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. M. Campbell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
H. L. Crawford,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (42 additional authors not shown)
Abstract:
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC…
▽ More
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. A simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.
△ Less
Submitted 24 March, 2021; v1 submitted 4 March, 2020;
originally announced March 2020.
-
A computer program for nuclear scattering at intermediate and high energies
Authors:
C. A. Bertulani,
C. M. Campbell,
T. Glasmacher
Abstract:
A computer program is presented which calculates the elastic and inelastic scattering in intermediate and high energy nuclear collisions. A coupled-channels method is used for Coulomb and nuclear excitations of E1, E2, E3, M1, and M2 multipolarities, respectively. The program applies to an arbitrary nucleus, specified by the spins and energies of the levels and by reduced matrix elements. For gi…
▽ More
A computer program is presented which calculates the elastic and inelastic scattering in intermediate and high energy nuclear collisions. A coupled-channels method is used for Coulomb and nuclear excitations of E1, E2, E3, M1, and M2 multipolarities, respectively. The program applies to an arbitrary nucleus, specified by the spins and energies of the levels and by reduced matrix elements. For given bombarding conditions, the angular distribution of elastic and inelastic scattered particles and angular distributions of gamma-rays from the excited nucleus are computed.
△ Less
Submitted 17 December, 2002; v1 submitted 12 July, 2002;
originally announced July 2002.