Radiochromic Film Dosimetry for VHEE and UHDR: Considerations for the CLEAR Facility and Comparisons with Alanine, RPL and Dosimetry Phantoms
Authors:
V. F. Rieker,
J. J. Bateman,
L. M. Wroe,
M. Caloz,
V. Grilj,
Y. Q. Aguiar,
A. Schüller,
C. Bailat,
W. Farabolini,
A. Gilardi,
C. Robertson,
P. Korysko,
A. Malyzhenkov,
S. Stapnes,
M. -C. Vozenin,
M. Dosanjh,
R. Corsini
Abstract:
Radiochromic films (RCFs) offer valuable two-dimensional dosimetry capabilities with a conceptually simple operating principle that requires minimal investment, making them particularly suitable for very high energy electron (VHEE) FLASH dosimetry where dosimetry standards are currently lacking. However, achieving high-accuracy measurements with RCFs presents significant practical challenges. With…
▽ More
Radiochromic films (RCFs) offer valuable two-dimensional dosimetry capabilities with a conceptually simple operating principle that requires minimal investment, making them particularly suitable for very high energy electron (VHEE) FLASH dosimetry where dosimetry standards are currently lacking. However, achieving high-accuracy measurements with RCFs presents significant practical challenges. Without the standardised protocols that ensure reliable outcomes across applications and facilities, knowledge of RCF behaviour becomes essential. This paper identifies common sources of error in RCF preparation, scanning, and processing while proposing specific mitigation strategies to improve accuracy and efficiency. Using our optimised RCF protocol at the CLEAR facility, we demonstrate relative agreement within 5% compared to alanine dosimeters when measuring Gaussian VHEE beams, establishing a foundation for reliable dosimetry in these advanced radiotherapy applications.
△ Less
Submitted 20 June, 2025;
originally announced June 2025.
-
Operation of parallel SNSPDs at high detection rates
Authors:
Matthieu Perrenoud,
Misael Caloz,
Emna Amri,
Claire Autebert,
Christian Schönenberger,
Hugo Zbinden,
Félix Bussières
Abstract:
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPD) has delivered ex-cellent performance, and their increased adoption has had a great impact on a range of applications. One of the key characteristic of SNSPDs is their detection rate, which is typically higher than other types of free-running single-photondetectors. The maximum achievable rate is limited…
▽ More
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPD) has delivered ex-cellent performance, and their increased adoption has had a great impact on a range of applications. One of the key characteristic of SNSPDs is their detection rate, which is typically higher than other types of free-running single-photondetectors. The maximum achievable rate is limited by the detector recovery time after a detection, which itself is linked to the superconducting material properties and to the geometry of the meandered SNSPD. Arrays of detectors biased individually can be used to solve this issue, but this approach significantly increases both the thermal load in the cryo-stat and the need for time processing of the many signals, and this scales unfavorably with a large number of detectors. One potential scalable approach to increase the detection rate of individual detectors further is based on parallelizing smaller meander sections. In this way, a single detection temporarily disables only one subsection of the whole active area, thereby leaving the overall detection efficiency mostly unaffected. In practice however, cross-talk between parallel nanowires typically leads to latching, which prevents high detection rates. Here we show how this problem can be avoided through a careful design of the whole SNSPD structure. Using the same electronic readout as with conventional SNSPDs and a single coaxial line, we demonstrate detection rates over 200 MHz without any latching, and a fibre-coupled SDE as high as 77%, and more than 50% average SDE per photon at 50 MHz detection rate under continuous wave illumination.
△ Less
Submitted 7 September, 2021;
originally announced September 2021.
-
Direct measurement of the recovery time of superconducting nanowire single-photon detectors
Authors:
Claire Autebert,
Gaëtan Gras,
Emna Amri,
Matthieu Perrenoud,
Misael Caloz,
Hugo Zbinden,
Félix Bussières
Abstract:
One of the key properties of single-photon detectors is their recovery time, i.e. the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterisation of this recovery time and its time dynamics is essential for many quantum op…
▽ More
One of the key properties of single-photon detectors is their recovery time, i.e. the time required for the detector to recover its nominal efficiency. In the case of superconducting nanowire single-photon detectors (SNSPDs), which can feature extremely short recovery times in free-running mode, a precise characterisation of this recovery time and its time dynamics is essential for many quantum optics or quantum communication experiments. We introduce a fast and simple method to characterise precisely the recovery time of SNSPDs. It provides full information about the recovery of the efficiency in time for a single or several consecutive detections. We also show how the method can be used to gain insight into the behaviour of the bias current inside the nanowire after a detection, which allows predicting the behaviour of the detector and its efficiency in any practical experiment using these detectors.
△ Less
Submitted 12 March, 2020;
originally announced March 2020.
-
Intrinsically-limited timing jitter in molybdenum silicide superconducting nanowire single-photon detectors
Authors:
Misael Caloz,
Boris Korzh,
Edward Ramirez,
Christian Schönenberger,
Richard J. Warburton,
Hugo Zbinden,
Matthew D. Shaw,
Félix Bussières
Abstract:
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performances, and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs…
▽ More
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) has delivered excellent performances, and has had a great impact on a range of research fields. The timing jitter, which denotes the temporal resolution of the detection, is a crucial parameter for many applications. Despite extensive work since their apparition, the lowest jitter achievable with SNSPDs is still not clear, and the origin of the intrinsic limits is not fully understood. Understanding its intrinsic behaviour and limits is a mandatory step toward improvements. Here, we report our experimental study on the intrinsically-limited timing jitter in molybdenum silicide (MoSi) SNSPDs. We show that to reach intrinsic jitter, several detector properties such as the latching current and the kinetic inductance of the devices have to be understood. The dependence on the nanowire cross-section and the energy dependence of the intrinsic jitter are exhibited, and the origin of the limits are explicited. System timing jitter of 6.0 ps at 532 nm and 10.6 ps at 1550 nm photon wavelength have been obtained.
△ Less
Submitted 5 June, 2019;
originally announced June 2019.
-
High-detection efficiency and low-timing jitter with amorphous superconducting nanowire single-photon detectors
Authors:
Misael Caloz,
Matthieu Perrenoud,
Claire Autebert,
Boris Korzh,
Markus Weiss,
Christian Schönenberger,
Richard J. Warburton,
Hugo Zbinden,
Félix Bussières
Abstract:
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) made of amorphous material has delivered excellent performances, and has had a great impact on a range of research fields. Despite showing the highest system detection efficiency (SDE) ever reported with SNSPDs, amorphous materials typically lead to lower critical currents, which impacts on their jitter…
▽ More
Recent progress in the development of superconducting nanowire single-photon detectors (SNSPDs) made of amorphous material has delivered excellent performances, and has had a great impact on a range of research fields. Despite showing the highest system detection efficiency (SDE) ever reported with SNSPDs, amorphous materials typically lead to lower critical currents, which impacts on their jitter performance. Combining a very low jitter and a high SDE remains a challenge. Here, we report on highly efficient superconducting nanowire single-photon detectors based on amorphous MoSi, combining system jitters as low as 26 ps and a SDE of 80% at 1550 nm. We also report detailed observations on the jitter behaviour, which hints at intrinsic limitations and leads to practical implications for SNSPD performance.
△ Less
Submitted 6 February, 2018; v1 submitted 18 October, 2017;
originally announced October 2017.
-
Optically probing the detection mechanism in a molybdenum silicide superconducting nanowire single-photon detector
Authors:
Misael Caloz,
Boris Korzh,
Nuala Timoney,
Markus Weiss,
Stefano Gariglio,
Richard J. Warburton,
Christian Schönenberger,
Jelmer Renema,
Hugo Zbinden,
Felix Bussieres
Abstract:
We experimentally investigate the detection mechanism in a meandered molybdenum silicide (MoSi) superconducting nanowire single-photon detector by characterising the detection probability as a function of bias current in the wavelength range of 750 to 2050 nm. Contrary to some previous observations on niobium nitride (NbN) or tungsten silicide (WSi) detectors, we find that the energy-current relat…
▽ More
We experimentally investigate the detection mechanism in a meandered molybdenum silicide (MoSi) superconducting nanowire single-photon detector by characterising the detection probability as a function of bias current in the wavelength range of 750 to 2050 nm. Contrary to some previous observations on niobium nitride (NbN) or tungsten silicide (WSi) detectors, we find that the energy-current relation is nonlinear in this range. Furthermore, thanks to the presence of a saturated detection efficiency over the whole range of wavelengths, we precisely quantify the shape of the curves. This allows a detailed study of their features, which are indicative of both Fano fluctuations and position-dependent effects.
△ Less
Submitted 24 November, 2016;
originally announced November 2016.