The LHCb VELO Upgrade Module Construction
Authors:
K. Akiba,
M. Alexander,
C. Bertella,
A. Biolchini,
A. Bitadze,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
K. Bridges,
M. Brock,
A. T. Burke,
J. Buytaert,
W. Byczynski,
J. Carroll,
V. Coco,
P. Collins,
A. Davis,
O. De Aguiar Francisco,
K. De Bruyn,
S. De Capua,
K. De Roo,
F. Doherty,
L. Douglas,
L. Dufour,
R. Dumps
, et al. (62 additional authors not shown)
Abstract:
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon dete…
▽ More
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.
△ Less
Submitted 21 April, 2024;
originally announced April 2024.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Microchannel cooling for the LHCb VELO Upgrade I
Authors:
Oscar Augusto De Aguiar Francisco,
Wiktor Byczynski,
Kazu Akiba,
Claudia Bertella,
Alexander Bitadze,
Matthew Brock,
Bartosz Bulat,
Guillaume Button,
Jan Buytaert,
Stefano De Capua,
Riccardo Callegari,
Christine Castellana,
Andrea Catinaccio,
Catherine Charrier,
Collette Charvet,
Victor Coco,
Paula Collins,
Jordan Degrange,
Raphael Dumps,
Diego Alvarez Feito,
Julian Freestone,
Mariusz Jedrychowski,
Vinicius Franco Lima,
Abraham Gallas,
Wouter Hulsbergen
, et al. (35 additional authors not shown)
Abstract:
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures…
▽ More
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures was completed in September 2021. This paper describes the R\&D path supporting the microchannel production and assembly and the motivation for the design choices. The microchannel coolers have excellent thermal peformance, low and uniform mass, no thermal expansion mismatch with the ASICs and are radiation hard. The fluidic and thermal performance is presented.
△ Less
Submitted 23 December, 2021;
originally announced December 2021.
-
Timing performance of the LHCb VELO Timepix3 Telescope
Authors:
K. Heijhoff,
K. Akiba,
M. van Beuzekom,
P. Bosch,
J. Buytaert,
M. Campbell,
A. P. Colijn,
P. Collins,
E. Dall'Occo,
T. Evans,
R. Geertsema,
M. L. E. Heidotting,
D. Hynds,
X. Llopart Cudie,
H. Schindler,
H. Snoek
Abstract:
We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal…
▽ More
We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal charge in the sensor to correct for a mixture of different effects: variations in charge carrier drift time; variations in signal induction, which are the result of a non-uniform weighting field in the pixels; and lastly, timewalk in the analog front-end. The second step corrects for systematic timing offsets in Timepix3 that vary from -2 ns to 2 ns. By applying this method, we improved the track time resolution from 438$\,\pm\,$16 ps to 276$\,\pm\,$4 ps.
△ Less
Submitted 11 August, 2020;
originally announced August 2020.
-
The HEV Ventilator
Authors:
J. Buytaert,
A. Abed Abud,
P. Allport,
A. Pazos Álvarez,
K. Akiba,
O. Augusto de Aguiar Francisco,
A. Bay,
F. Bernard,
S. Baron,
C. Bertella,
J. Brunner,
T. Bowcock,
M. Buytaert-De Jode,
W. Byczynski,
R. De Carvalho,
V. Coco,
P. Collins,
R. Collins,
N. Dikic,
N. Dousse,
B. Dowd,
R. Dumps,
P. Durante,
W. Fadel,
S. Farry
, et al. (49 additional authors not shown)
Abstract:
HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The stan…
▽ More
HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform
Authors:
P. Kopciewicz,
T. Szumlak,
M. Majewski,
K. Akiba,
O. Augusto,
J. Back,
D. S. Bobulska,
G. Bogdanova,
S. Borghi,
T. Bowcock,
J. Buytaert,
E. Lemos Cid,
V. Coco,
P. Collins,
E. Dall'Occo,
K. de Bruyn,
S. de Capua,
F. Dettori,
K. Dreimanis,
D. Dutta,
L. Eklund,
T. Evans,
M. Ferro-Luzzi W. Funk,
L. Meyer Garcia,
O. Boente García
, et al. (41 additional authors not shown)
Abstract:
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in…
▽ More
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.
△ Less
Submitted 22 July, 2022; v1 submitted 16 June, 2020;
originally announced June 2020.
-
The HEV Ventilator Proposal
Authors:
J. Buytaert,
A. Abed Abud,
K. Akiba,
A. Bay,
C. Bertella,
T. Bowcock,
W. Byczynski,
V. Coco,
P. Collins,
O. Augusto De Aguiar Francisco,
N. Dikic,
R. Dumps,
P. Durante,
A. Fernández Prieto,
V. Franco Lima,
R. Guida,
K. Hennessy,
D. Hutchcroft,
S. Ilic,
A. Jevtic,
K. Kapusniak,
E. Lemos Cid,
J. Lindner,
M. Milovanovic,
D. Murray
, et al. (6 additional authors not shown)
Abstract:
We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is i…
▽ More
We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is in the concept and prototyping stage. It is presented here to invite fast feedback for development and deployment in the face of the COVID-19 pandemic.
△ Less
Submitted 2 April, 2020; v1 submitted 1 April, 2020;
originally announced April 2020.
-
LHCb VELO Timepix3 Telescope
Authors:
Kazu Akiba,
Martin van Beuzekom,
Henk Boterenbrood,
Emma Buchanan,
Jan Buytaert,
Wiktor Byczynski,
Xabier Cid Vidal,
Paula Collins,
Elena Dall'Occo,
Alvaro Dosil Suarez,
Raphael Dumps,
Tim Evans,
Vinicius Franco Lima,
Abraham Gallas Torreira,
Julian Garcia Pardinas,
Bas van der Heijden,
Christoph Hombach,
Malcolm John,
Szymon Kulis,
Xavi Llopart Cudie,
Franciole Marinho,
Eugenia Price,
Sophie Richards,
Pablo Rodriguez Perez,
Daniel Saunders
, et al. (8 additional authors not shown)
Abstract:
The LHCb VELO Timepix3 telescope is a silicon pixel tracking system constructed initially to evaluate the performance of LHCb VELO Upgrade prototypes. The telesope consists of eight hybrid pixel silicon sensor planes equipped with the Timepix3 ASIC. The planes provide excellent charge measurement, timestamping and spatial resolution and the system can function at high track rates. This paper descr…
▽ More
The LHCb VELO Timepix3 telescope is a silicon pixel tracking system constructed initially to evaluate the performance of LHCb VELO Upgrade prototypes. The telesope consists of eight hybrid pixel silicon sensor planes equipped with the Timepix3 ASIC. The planes provide excellent charge measurement, timestamping and spatial resolution and the system can function at high track rates. This paper describes the construction of the telescope and its data acquisition system and offline reconstruction software. A timing resolution of 350~ps was obtained for reconstructed tracks. A pointing resolution of better than 2~\mum was determined for the 180~GeV/c %\gevc mixed hadron beam at the CERN SPS. The telescope has been shown to operate at a rate of 5 million particles~\unit{s^{-1}\cdot cm^{-2}} without a loss in efficiency.
△ Less
Submitted 26 February, 2019;
originally announced February 2019.
-
Mapping the material in the LHCb vertex locator using secondary hadronic interactions
Authors:
M. Alexander,
W. Barter,
A. Bay,
L. J. Bel,
M. van Beuzekom,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
E. Buchanan,
J. Buytaert,
K. Carvalho Akiba,
S. Chen,
V. Coco,
P. Collins,
A. Crocombe,
F. Da Cunha Marinho,
E. Dall'Occo,
S. De Capua,
C. T. Dean,
F. Dettori,
D. Dossett,
K. Dreimanis,
G. Dujany,
L. Eklund,
T. Evans
, et al. (41 additional authors not shown)
Abstract:
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties…
▽ More
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties of a reconstructed secondary vertex and its constituent tracks, a $p$-value can be assigned to the hypothesis that the secondary vertex originates from a material interaction. A validation of this procedure is presented using photon conversions to dimuons.
△ Less
Submitted 18 June, 2018; v1 submitted 20 March, 2018;
originally announced March 2018.
-
Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam
Authors:
K. Akiba,
R. Aoude,
J. Alozy,
M. van Beuzekom,
J. Buytaert,
P. Collins,
A. Dosil Suárez,
R. Dumps,
A. Gallas,
C. Hombach,
D. Hynds,
M. John,
A. Leflat,
Y. Li,
E. Pérez Trigo,
R. Plackett,
M. M. Reid,
P. Rodríguez Pérez,
H. Schindler,
P. Tsopelas,
C. Vázquez Sierra,
J. J. Velthuis,
M. Wysokiński
Abstract:
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.
△ Less
Submitted 12 January, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Performance of the LHCb Vertex Locator
Authors:
LHCb VELO Group,
R. Aaij,
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
R. B. Appleby,
M. Artuso,
A. Bates,
A. Bay,
O. Behrendt,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
A. Borgia,
T. J. V. Bowcock,
J. van den Brand,
H. Brown,
J. Buytaert,
O. Callot,
J. Carroll,
G. Casse,
P. Collins
, et al. (79 additional authors not shown)
Abstract:
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stabi…
▽ More
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.
△ Less
Submitted 10 September, 2014; v1 submitted 30 May, 2014;
originally announced May 2014.
-
The Timepix Telescope for High Performance Particle Tracking
Authors:
Kazuyoshi Akiba,
Per Arne Ronning,
Martin van Beuzekom,
Vincent van Beveren,
Silvia Borghi,
Henk Boterenbrood,
Jan Buytaert,
Paula Collins,
Alvaro Dosil Suarez,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Abraham Gallas,
Hamish Gordon,
Bas van der Heijden,
Christoph Hombach,
Daniel Hynds,
Malcolm John,
Alexander Leflat,
Yi Ming Li,
Ian Longstaff,
Alexander Morton,
Noritsugu Nakatsuka,
Andre Nomerotski,
Chris Parkes
, et al. (10 additional authors not shown)
Abstract:
The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed arou…
▽ More
The Timepix particle tracking telescope has been developed as part of the LHCb VELO Upgrade project, supported by the Medipix Collaboration and the AIDA framework. It is a primary piece of infrastructure for the VELO Upgrade project and is being used for the development of new sensors and front end technologies for several upcoming LHC trackers and vertexing systems. The telescope is designed around the dual capability of the Timepix ASICs to provide information about either the deposited charge or the timing information from tracks traversing the 14 x 14mm matrix of 55 x 55 um pixels. The rate of reconstructed tracks available is optimised by taking advantage of the shutter driven readout architecture of the Timepix chip, operated with existing readout systems. Results of tests conducted in the SPS North Area beam facility at CERN show that the telescope typically provides reconstructed track rates during the beam spills of between 3.5 and 7.5 kHz, depending on beam conditions. The tracks are time stamped with 1 ns resolution with an efficiency of above 98% and provide a pointing resolution at the centre of the telescope of 1.6 um . By dropping the time stamping requirement the rate can be increased to 15 kHz, at the expense of a small increase in background. The telescope infrastructure provides CO2 cooling and a flexible mechanical interface to the device under test, and has been used for a wide range of measurements during the 2011-2012 data taking campaigns.
△ Less
Submitted 18 April, 2013;
originally announced April 2013.
-
Radiation damage in the LHCb Vertex Locator
Authors:
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
M. Artuso,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
H. Brown,
J. Buytaert,
G. Casse,
P. Collins,
S. De Capua,
D. Dossett,
L. Eklund,
C. Farinelli,
J. Garofoli,
M. Gersabeck,
T. Gershon,
H. Gordon,
J. Harrison,
V. Heijne
, et al. (26 additional authors not shown)
Abstract:
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the op…
▽ More
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the operational sensor temperature of approximately $-7\,^{\circ}\rm{C}$, the average rate of sensor current increase is $18\,\upmu\rm{A}$ per $\rm{fb^{-1}}$, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of $E_{g}=1.16\pm0.03\pm0.04\,\rm{eV}$ obtained. The first observation of n-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around $15 \times 10 ^{12}$ of $1\,\rm{MeV\,n_{eq}}$. The only n-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately $\rm{3 \times 10^{12}\,1\,MeV\,n_{eq}}$, a decrease in the Effective Depletion Voltage (EDV) of around 25\,V is observed, attributed to oxygen induced removal of boron interstitial sites. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n-on-n type sensors, with rates of $(1.43\pm 0.16) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ and $(1.35\pm 0.25) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ measured for n-on-p and n-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed.
△ Less
Submitted 21 February, 2013;
originally announced February 2013.
-
Large-volume optical coherence tomography with real-time correction of geometric distortion artifacts
Authors:
Sam Van der Jeught,
Jan A. N. Buytaert,
Adrian Bradu,
Adrian Gh. Podoleanu,
Joris J. J. Dirckx
Abstract:
Large-volume optical coherence tomography (OCT)-setups employ scanning mirrors and suffer from non-linear geometric distortion artifacts in which the degree of distortion is determined by the maximum angles over which the mirrors rotate. In this chapter, we describe a straightforward approach to correct for these distortion artifacts, creating an alternative to previously reported ray-tracing sche…
▽ More
Large-volume optical coherence tomography (OCT)-setups employ scanning mirrors and suffer from non-linear geometric distortion artifacts in which the degree of distortion is determined by the maximum angles over which the mirrors rotate. In this chapter, we describe a straightforward approach to correct for these distortion artifacts, creating an alternative to previously reported ray-tracing schemes that are unable to apply these corrections in real-time. By implementing the proposed 3D recalibration algorithm on the graphics card of a standard computer, this feature can be applied in real-time. We validate the accuracy of the technique using OCT measurements of a highly curved object within a large imaging volume of 12.35 x 10.13 x 2.36 mm^3. The resulting 3D object shape measurements are compared against high-resolution and aberration-free optical profilometry measurements. Maintaining an optical resolution of <10 micron within the sample, both axially and transversally, we realized a real-time, high-resolution, large-volume OCT imaging system, capable of producing distortion corrected wide-field OCT data with a geometric surface shape accuracy of <15 micron.
△ Less
Submitted 7 December, 2012;
originally announced December 2012.
-
Evaporative CO2 cooling using microchannels etched in silicon for the future LHCb vertex detector
Authors:
A. Nomerotski,
J. Buytart,
P. Collins,
R. Dumps,
E. Greening,
M. John,
A. Mapelli,
A. Leflat,
Y. Li,
G. Romagnoli,
B. Verlaat
Abstract:
The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a s…
▽ More
The extreme radiation dose received by vertex detectors at the Large Hadron Collider dictates stringent requirements on their cooling systems. To be robust against radiation damage, sensors should be maintained below -20 degree C and at the same time, the considerable heat load generated in the readout chips and the sensors must be removed. Evaporative CO2 cooling using microchannels etched in a silicon plane in thermal contact with the readout chips is an attractive option. In this paper, we present the first results of microchannel prototypes with circulating, two-phase CO2 and compare them to simulations. We also discuss a practical design of upgraded VELO detector for the LHCb experiment employing this approach.
△ Less
Submitted 16 February, 2013; v1 submitted 6 November, 2012;
originally announced November 2012.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures
Authors:
J. A. N. Buytaert,
W. H. M. Salih,
M. Dierick,
P. Jacobs,
J. J. J. Dirckx
Abstract:
In order to improve realism in middle ear (ME) finite element modeling (FEM), comprehensive and precise morphological data are needed. To date, micro-scale X-ray computed tomography (μCT) recordings have been used as geometric input data for FEM models of the ME ossicles. Previously, attempts were made to obtain this data on ME soft tissue structures as well. However, due to low X-ray absorption o…
▽ More
In order to improve realism in middle ear (ME) finite element modeling (FEM), comprehensive and precise morphological data are needed. To date, micro-scale X-ray computed tomography (μCT) recordings have been used as geometric input data for FEM models of the ME ossicles. Previously, attempts were made to obtain this data on ME soft tissue structures as well. However, due to low X-ray absorption of soft tissue, quality of these images is limited. Another popular approach is using histological sections as data for 3D models, delivering high in-plane resolution for the sections, but the technique is destructive in nature and registration of the sections is difficult.
We combine data from high-resolution μCT recordings with data from high-resolution orthogonal-plane fluorescence optical-sectioning microscopy (OPFOS), both obtained on the same gerbil specimen. State-of-the-art μCT delivers high-resolution data on the three-dimensional shape of ossicles and other ME bony structures, while the OPFOS setup generates data of unprecedented quality both on bone and soft tissue ME structures. Each of these techniques is tomographic and non-destructive, and delivers sets of automatically aligned virtual sections. The datasets coming from different techniques need to be registered with respect to each other. By combining both datasets, we obtain a complete high-resolution morphological model of all functional components in the gerbil ME. The resulting three-dimensional model can be readily imported in FEM software and is made freely available to the research community. In this paper, we discuss the methods used, present the resulting merged model and discuss morphological properties of the soft tissue structures, such as muscles and ligaments.
△ Less
Submitted 16 June, 2011;
originally announced June 2011.
-
The OPFOS microscopy family: High-resolution optical-sectioning of biomedical specimens
Authors:
Jan A. N. Buytaert,
Emilie Descamps,
Dominique Adriaens,
Joris J. J. Dirckx
Abstract:
We report on the recently emerging (Laser) Light Sheet based Fluorescence Microscopy field (LSFM). The techniques used in this field allow to study and visualize biomedical objects non-destructively in high-resolution through virtual optical sectioning with sheets of laser light. Fluorescence originating in the cross section of the sheet and sample is recorded orthogonally with a camera. In this p…
▽ More
We report on the recently emerging (Laser) Light Sheet based Fluorescence Microscopy field (LSFM). The techniques used in this field allow to study and visualize biomedical objects non-destructively in high-resolution through virtual optical sectioning with sheets of laser light. Fluorescence originating in the cross section of the sheet and sample is recorded orthogonally with a camera. In this paper, the first implementation of LSFM to image biomedical tissue in three dimensions - Orthogonal-Plane Fluorescence Optical Sectioning microscopy (OPFOS) - is discussed. Since then many similar and derived methods have surfaced (SPIM, Ultramicroscopy, HR-OPFOS, mSPIM, DSLM, TSLIM...) which we all briefly discuss. All these optical sectioning methods create images showing histological detail. We illustrate the applicability of LSFM on several specimen types with application in biomedical and life sciences.
△ Less
Submitted 16 June, 2011;
originally announced June 2011.
-
Charged Particle Tracking with the Timepix ASIC
Authors:
Kazuyoshi Akiba,
Marina Artuso,
Ryan Badman,
Alessandra Borgia,
Richard Bates,
Florian Bayer,
Martin van Beuzekom,
Jan Buytaert,
Enric Cabruja,
Michael Campbell,
Paula Collins,
Michael Crossley,
Raphael Dumps,
Lars Eklund,
Daniel Esperante,
Celeste Fleta,
Abraham Gallas,
Miriam Gandelman,
Justin Garofoli,
Marco Gersabeck,
Vladimir V. Gligorov,
Hamish Gordon,
Erik H. M. Heijne,
Veerle Heijne,
Daniel Hynds
, et al. (17 additional authors not shown)
Abstract:
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was u…
▽ More
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron square pixels. The telescope achieved a pointing resolution of 2.3 micron at the position of the device under test. During a beam test in 2009 the telescope was used to evaluate in detail the performance of two Timepix hybrid pixel assemblies; a standard planar 300 micron thick sensor, and 285 micron thick double sided 3D sensor. This paper describes a detailed charge calibration study of the pixel devices, which allows the true charge to be extracted, and reports on measurements of the charge collection characteristics and Landau distributions. The planar sensor achieved a best resolution of 4.0 micron for angled tracks, and resolutions of between 4.4 and 11 micron for perpendicular tracks, depending on the applied bias voltage. The double sided 3D sensor, which has significantly less charge sharing, was found to have an optimal resolution of 9.0 micron for angled tracks, and a resolution of 16.0 micron for perpendicular tracks. Based on these studies it is concluded that the Timepix ASIC shows an excellent performance when used as a device for charged particle tracking.
△ Less
Submitted 14 June, 2011; v1 submitted 14 March, 2011;
originally announced March 2011.