-
Diffractively coupled Fabry-Perot resonator with power-recycling
Authors:
Michael Britzger,
Daniel Friedrich,
Stefanie Kroker,
Frank Brückner,
Oliver Burmeister,
Ernst-Bernhard Kley,
Andreas Tünnermann,
Karsten Danzmann,
Roman Schnabel
Abstract:
We demonstrate the optical coupling of two cavities without light transmission through a substrate. Compared to a conventional coupling component, that is a partially transmissive mirror, an all-reflective coupler avoids light absorption in the substrate and therefore associated thermal problems, and even allows the use of opaque materials with possibly favourable mechanical and thermal properties…
▽ More
We demonstrate the optical coupling of two cavities without light transmission through a substrate. Compared to a conventional coupling component, that is a partially transmissive mirror, an all-reflective coupler avoids light absorption in the substrate and therefore associated thermal problems, and even allows the use of opaque materials with possibly favourable mechanical and thermal properties. Recently, the all-reflective coupling of two cavities with a low-efficiency 3-port diffraction grating was theoretically investigated. Such a grating has an additional (a third) port. However, it was shown that the additional port does not necessarily decrease the bandwidth of the coupled cavities. Such an all-reflective scheme for cavity coupling is of interest in the field of gravitational wave detection. In such detectors light that is resonantly enhanced inside the so-called power-recycling cavity is coupled to (kilometre-scale) Fabry-Perot resonators representing the arms of a Michelson interferometer. In order to achieve a high sensitivity over a broad spectrum, the Fabry-Perot resonators need to have a high bandwidth for a given (high) power build-up. We realized such an all-reflective coupling in a table-top experiment. Our findings are in full agreement with the theoretical model incorporating the characteristics of the 3-port grating used, and therefore encourage the application of all-reflective cavity couplers in future gravitational wave detectors.
△ Less
Submitted 2 May, 2011;
originally announced May 2011.
-
Realization of a monolithic high-reflectivity cavity mirror from a single silicon crystal
Authors:
Frank Brückner,
Daniel Friedrich,
Tina Clausnitzer,
Michael Britzger,
Oliver Burmeister,
Karsten Danzmann,
Ernst-Bernhard Kley,
Andreas Tünnermann,
Roman Schnabel
Abstract:
We report on the first experimental realization of a high-reflectivity cavity mirror that solely consists of a single silicon crystal. Since no material was added to the crystal, the urgent problem of 'coating thermal noise' that currently limits classical as well as quantum measurements is avoided. Our mirror is based on a surface nanostructure that creates a resonant surface waveguide. In full a…
▽ More
We report on the first experimental realization of a high-reflectivity cavity mirror that solely consists of a single silicon crystal. Since no material was added to the crystal, the urgent problem of 'coating thermal noise' that currently limits classical as well as quantum measurements is avoided. Our mirror is based on a surface nanostructure that creates a resonant surface waveguide. In full agreement with a rigorous model we realized a reflectivity of (99.79+/-0.01)% at a wavelength of 1.55 μm, and achieved a cavity finesse of 2784. We anticipate that our achievement will open the avenue to next generation high-precision experiments targeting fundamental questions of physics.
△ Less
Submitted 14 April, 2010;
originally announced April 2010.
-
All-reflective coupling of two optical cavities with 3-port diffraction gratings
Authors:
Oliver Burmeister,
Michael Britzger,
André Thüring,
Daniel Friedrich,
Frank Brückner,
Karsten Danzmann,
Roman Schnabel
Abstract:
The shot-noise limited sensitivity of Michelson-type laser interferometers with Fabry-Perot arm cavities can be increased by the so-called power-recycling technique. In such a scheme the power-recycling cavity is optically coupled with the interferometer's arm cavities. A problem arises because the central coupling mirror transmits a rather high laser power and may show thermal lensing, thermo-ref…
▽ More
The shot-noise limited sensitivity of Michelson-type laser interferometers with Fabry-Perot arm cavities can be increased by the so-called power-recycling technique. In such a scheme the power-recycling cavity is optically coupled with the interferometer's arm cavities. A problem arises because the central coupling mirror transmits a rather high laser power and may show thermal lensing, thermo-refractive noise and photo-thermo-refractive noise. Cryogenic cooling of this mirror is also challenging, and thus thermal noise becomes a general problem. Here, we theoretically investigate an all-reflective coupling scheme of two optical cavities based on a 3-port diffraction grating. We show that power-recycling of a high-finesse arm cavity is possible without transmitting any laser power through a substrate material. The power splitting ratio of the three output ports of the grating is, surprisingly, noncritical.
△ Less
Submitted 13 April, 2010;
originally announced April 2010.
-
Building blocks for future detectors: Silicon test masses and 1550 nm laser light
Authors:
R. Schnabel,
M. Britzger,
F. Brückner,
O. Burmeister,
K. Danzmann,
J. Dück,
T. Eberle,
D. Friedrich,
H. Lück,
M. Mehmet,
R. Nawrodt,
S. Steinlechner,
B. Willke
Abstract:
Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatu…
▽ More
Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatures might be important ingredients in order to achieve the sensitivity goal. Here we compare some properties of the fused silica and silicon test mass materials relevant for decreasing the thermal noise in future detectors as well as the recent technology achievements in the preparation of laser radiation at 1064 nm and 1550 nm relevant for decreasing the quantum noise. We conclude that silicon test masses and 1550 nm laser light have the potential to form the future building blocks of gravitational wave detection.
△ Less
Submitted 16 December, 2009;
originally announced December 2009.
-
Optical characterization of ultra-high diffraction efficiency gratings
Authors:
A. Bunkowski,
O. Burmeister,
T. Clausnitzer,
E. -B. Kley,
A. Tünnermann,
K. Danzmann,
R. Schnabel
Abstract:
We report on the optical characterization of an ultra-high diffraction efficiency grating in 1st order Littrow configuration. The apparatus used was an optical cavity built from the grating under investigation and an additional high reflection mirror. Measurement of the cavity finesse provided precise information about the grating's diffraction efficiency and its optical loss. We measured a fine…
▽ More
We report on the optical characterization of an ultra-high diffraction efficiency grating in 1st order Littrow configuration. The apparatus used was an optical cavity built from the grating under investigation and an additional high reflection mirror. Measurement of the cavity finesse provided precise information about the grating's diffraction efficiency and its optical loss. We measured a finesse of 1580 from which we deduced a diffraction efficiency of (99.635$\pm$0.016)% and an overall optical loss due to scattering and absorption of just 0.185 %.
Such high quality gratings, including the tool used for their characterization, might apply for future gravitational wave detectors. For example the demonstrated cavity itself presents an all-reflective, low-loss Fabry-Perot resonator that might replace conventional arm cavities in advanced high power Michelson interferometers.
△ Less
Submitted 5 July, 2007;
originally announced July 2007.
-
Demonstration of 3-port grating phase relations
Authors:
A. Bunkowski,
O. Burmeister,
K. Danzmann,
R. Schnabel
Abstract:
We experimentally demonstrate the phase relations of 3-port gratings by investigating 3-port coupled Fabry-Perot cavities. Two different gratings which have the same 1st order diffraction efficiency but differ substantially in their 2nd order diffraction efficiency have been designed and manufactured. Using the gratings as couplers to Fabry-Perot cavities we could validate the results of an earl…
▽ More
We experimentally demonstrate the phase relations of 3-port gratings by investigating 3-port coupled Fabry-Perot cavities. Two different gratings which have the same 1st order diffraction efficiency but differ substantially in their 2nd order diffraction efficiency have been designed and manufactured. Using the gratings as couplers to Fabry-Perot cavities we could validate the results of an earlier theoretical description of the phases at a three port grating.
△ Less
Submitted 4 July, 2007;
originally announced July 2007.
-
Input-output relations for a 3-port grating coupled Fabry-Perot cavity
Authors:
A. Bunkowski,
O. Burmeister,
K. Danzmann,
R. Schnabel
Abstract:
We analyze an optical 3-port reflection grating by means of a scattering matrix formalism. Amplitude and phase relations between the 3 ports, i.e. the 3 orders of diffraction are derived. Such a grating can be used as an all-reflective, low-loss coupler to Fabry-Perot cavities. We derive the input output relations of a 3-port grating coupled cavity and find distinct properties not present in 2-p…
▽ More
We analyze an optical 3-port reflection grating by means of a scattering matrix formalism. Amplitude and phase relations between the 3 ports, i.e. the 3 orders of diffraction are derived. Such a grating can be used as an all-reflective, low-loss coupler to Fabry-Perot cavities. We derive the input output relations of a 3-port grating coupled cavity and find distinct properties not present in 2-port coupled cavities. The cavity relations further reveal that the 3-port coupler can be designed such that the additional cavity port interferes destructively. In this case the all-reflective, low-loss, single-ended Fabry-Perot cavity becomes equivalent to a standard transmissive, 2-port coupled cavity.
△ Less
Submitted 4 July, 2007;
originally announced July 2007.
-
Diffractive Optics for Gravitational Wave Detectors
Authors:
A. Bunkowski,
O. Burmeister,
K. Danzmann,
R. Schnabel,
T. Clausnitzer,
E. -B. Kley,
A. Tünnermann
Abstract:
All-reflective interferometry based on nano-structured diffraction gratings offers new possibilities for gravitational wave detection. We investigate an all-reflective Fabry-Perot interferometer concept in 2nd order Littrow mount. The input-output relations for such a resonator are derived treating the grating coupler by means of a scattering matrix formalism. A low loss dielectric reflection gr…
▽ More
All-reflective interferometry based on nano-structured diffraction gratings offers new possibilities for gravitational wave detection. We investigate an all-reflective Fabry-Perot interferometer concept in 2nd order Littrow mount. The input-output relations for such a resonator are derived treating the grating coupler by means of a scattering matrix formalism. A low loss dielectric reflection grating has been designed and manufactured to test the properties of such a grating cavity.
△ Less
Submitted 4 July, 2007;
originally announced July 2007.
-
Low-loss grating for coupling to a high-finesse cavity
Authors:
A. Bunkowski,
O. Burmeister,
P. Beyersdorf,
K. Danzmann,
R. Schnabel,
T. Clausnitzer,
E. -B. Kley,
A. Tünnermann
Abstract:
A concept for a low loss all-reflective cavity coupler is experimentally demonstrated at a wavelength of 1064 nm. A 1450 nm period dielectric reflection grating with a diffraction efficiency of 0.58 % in the -1st order is used in 2nd order Littrow configuration as a coupler to form a cavity with a finesse of 400. The application of such reflective low-loss cavity couplers in future generations o…
▽ More
A concept for a low loss all-reflective cavity coupler is experimentally demonstrated at a wavelength of 1064 nm. A 1450 nm period dielectric reflection grating with a diffraction efficiency of 0.58 % in the -1st order is used in 2nd order Littrow configuration as a coupler to form a cavity with a finesse of 400. The application of such reflective low-loss cavity couplers in future generations of gravitational-wave detectors as well as some implementation issues are discussed.
△ Less
Submitted 4 July, 2007;
originally announced July 2007.
-
Three-port beam splitters-combiners for interferometer applications
Authors:
R. Schnabel,
A. Bunkowski,
O. Burmeister,
K. Danzmann
Abstract:
We derive generic phase and amplitude coupling relations for beam splitters-combiners that couple a single port with three output ports or input ports, respectively. We apply the coupling relations to a reflection grating that serves as a coupler to a single-ended Fabry-Perot ring cavity. In the impedance-matched case such an interferometer can act as an all-reflective ring mode cleaner. It is f…
▽ More
We derive generic phase and amplitude coupling relations for beam splitters-combiners that couple a single port with three output ports or input ports, respectively. We apply the coupling relations to a reflection grating that serves as a coupler to a single-ended Fabry-Perot ring cavity. In the impedance-matched case such an interferometer can act as an all-reflective ring mode cleaner. It is further shown that in the highly undercoupled case almost complete separation of carrier power and phase signal from a cavity strain can be achieved.
△ Less
Submitted 2 July, 2007;
originally announced July 2007.