Particle Detection Using Magnetic Avalanches in Single-Molecule Magnet Crystals
Authors:
Bailey Kohn,
Hao Chen,
Rupak Mahapatra,
Glenn Agnolet,
Ivan Borzenets,
Philip C. Bunting,
Jeffrey R. Long,
Minjie Lu,
Tom Melia,
Michael Nippe,
Lok Raj Pant,
Surjeet Rajendran,
Anna Schmautz,
Amis Sharma
Abstract:
The detection of a single quantum of energy with high efficiency and a low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We confirm our initial experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM…
▽ More
The detection of a single quantum of energy with high efficiency and a low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We confirm our initial experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM) crystals made of Mn$_{12}$-acetate, establishing the use of SMMs as particle detectors for the first time. Although the current setup has an energy threshold in the MeV regime, our results motivate the exploration of a wide variety of SMMs whose properties could allow for detection of sub-eV energy depositions.
△ Less
Submitted 4 August, 2025;
originally announced August 2025.
-
Infra-red thermographic inversion in ST40
Authors:
Matteo Moscheni,
Erik Maartensson,
Matthew Robinson,
Chris Marsden,
Adrian Rengle,
Andrea Scarabosio,
Patrick Bunting,
Travis Kelly Gray,
Salomon Janhunen,
Elena Vekshina,
Xin Zhang
Abstract:
Infra-red (IR) thermography is an essential diagnostic tool for understanding the edge plasma behavior in fusion devices. In this work, we present a new in-house numerical tool, Functional Analysis of Heat Flux (FAHF), for IR thermographic inversion on Tokamak Energy's spherical tokamak (ST40). FAHF, written in Python, is designed for multi-2D thermographic inversions by solving the heat conductio…
▽ More
Infra-red (IR) thermography is an essential diagnostic tool for understanding the edge plasma behavior in fusion devices. In this work, we present a new in-house numerical tool, Functional Analysis of Heat Flux (FAHF), for IR thermographic inversion on Tokamak Energy's spherical tokamak (ST40). FAHF, written in Python, is designed for multi-2D thermographic inversions by solving the heat conduction equation within the divertor tiles using the finite difference method, and an explicit time stepping scheme. Utilising IR camera data with the highest available effective spatial resolution, FAHF calculates the plasma perpendicular heat flux density on the divertor tile surfaces -- a crucial quantity for edge plasma analysis. The tool's internal numerics is first verified through formal time and space convergence analyses, and further corroborated by an energy balance assessment. Although FAHF demonstrates significant sensitivity to user-selected spatial resolution, precise heat flux values are recoverable by ensuring a sufficiently high resolution. Implications for the optimal resolution of both the code and the diagnostic system are discussed. Finally, FAHF's model and geometry simplifications are confirmed to be accurate within 10%, based on comparison with COMSOL Multiphysics simulations. As such, FAHF is proven to be a precise and accurate tool for IR thermographic inversions in ST40.
△ Less
Submitted 23 October, 2024; v1 submitted 6 September, 2024;
originally announced September 2024.
-
Quantum Detection using Magnetic Avalanches in Single-Molecule Magnets
Authors:
Hao Chen,
Rupak Mahapatra,
Glenn Agnolet,
Michael Nippe,
Minjie Lu,
Philip C. Bunting,
Tom Melia,
Surjeet Rajendran,
Giorgio Gratta,
Jeffrey Long
Abstract:
The detection of a single quantum of energy with high efficiency and low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We report the first experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM) cry…
▽ More
The detection of a single quantum of energy with high efficiency and low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We report the first experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM) crystals made of Mn12-acetate, establishing the use of SMMs as particle detectors for the first time. While the current setup has an energy threshold in the MeV regime, our results motivate the exploration of a wide variety of SMMs whose properties could allow for detection of sub-eV energy depositions.
△ Less
Submitted 24 May, 2020; v1 submitted 21 February, 2020;
originally announced February 2020.
-
Magnetic Bubble Chambers and Sub-GeV Dark Matter Direct Detection
Authors:
Philip C. Bunting,
Giorgio Gratta,
Tom Melia,
Surjeet Rajendran
Abstract:
We propose a new application of single molecule magnet crystals: their use as "magnetic bubble chambers" for the direct detection of sub-GeV dark matter. The spins in these macroscopic crystals effectively act as independent nano-scale magnets. When anti-aligned with an external magnetic field they form meta-stable states with a relaxation time that can be very long at sufficiently low temperature…
▽ More
We propose a new application of single molecule magnet crystals: their use as "magnetic bubble chambers" for the direct detection of sub-GeV dark matter. The spins in these macroscopic crystals effectively act as independent nano-scale magnets. When anti-aligned with an external magnetic field they form meta-stable states with a relaxation time that can be very long at sufficiently low temperatures. The Zeeman energy stored in this system can be released through localized heating, caused for example by the scattering or absorption of dark matter, resulting in a spin avalanche (or "magnetic deflagration") that amplifies the effects of the initial heat deposit, enabling detection. Much like the temperature and pressure in a conventional bubble chamber, the temperature and external magnetic field set the detection threshold for a single molecule magnet crystal. We discuss this detector concept for dark matter detection and propose ways to ameliorate backgrounds. If successfully developed, this detector concept can search for hidden photon dark matter in the meV - eV mass range with sensitivities exceeding current bounds by several orders of magnitude.
△ Less
Submitted 3 May, 2017; v1 submitted 23 January, 2017;
originally announced January 2017.