-
An all-optical intrinsic atomic gradiometer with sub-20 fT/cm/$\sqrt{\rm Hz}$ sensitivity in a 22 $μ$T earth-scale magnetic field
Authors:
A. R. Perry,
M. D. Bulatowicz,
M. Larsen,
T. G. Walker,
R. Wyllie
Abstract:
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/$\sqrt{\rm Hz}$ at the finite field strength of 22 $μ$T. The experimental timing sequence can be tuned to the field magnitude of interest. Our one dimensional all-opt…
▽ More
In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/$\sqrt{\rm Hz}$ at the finite field strength of 22 $μ$T. The experimental timing sequence can be tuned to the field magnitude of interest. Our one dimensional all-optical gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.
△ Less
Submitted 15 November, 2020; v1 submitted 30 August, 2020;
originally announced August 2020.
-
Continuous Comagnetometry using Transversely Polarized Xe Isotopes
Authors:
D. Thrasher,
S. Sorensen,
J. Weber,
M. Bulatowicz,
A. Korver,
M. Larsen,
T. G. Walker
Abstract:
We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as $^{131}$Xe and $^{129}$Xe nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repet…
▽ More
We demonstrate a transversely polarized spin-exchange pumped noble gas comagnetometer which suppresses systematic errors from longitudinal polarization. Rb atoms as well as $^{131}$Xe and $^{129}$Xe nuclei are simultaneously polarized perpendicular to a pulsed bias field. Both Xe isotopes' nuclear magnetic resonance conditions are simultaneously satisfied by frequency modulation of the pulse repetition rate. The Rb atoms detect the Xe precession. We highlight the importance of magnetometer phase shifts when performing comagnetometry. For detection of non-magnetic spin-dependent interactions the sensing bandwidth is 1 Hz, the white-noise level is 7 $μ$Hz /$\sqrt{\text{Hz}}$, and the bias stability is $\approx1$ $μ$Hz.
△ Less
Submitted 21 November, 2019; v1 submitted 4 October, 2019;
originally announced October 2019.
-
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Authors:
I. A. Sulai,
Z. J. DeLand,
M. D. Bulatowicz,
C. P. Wahl,
R. T. Wakai,
T. G. Walker
Abstract:
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices (SQUIDs) due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free (SERF) vector atomic magnetic gradiometer with sens…
▽ More
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices (SQUIDs) due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free (SERF) vector atomic magnetic gradiometer with sensitivity of $3\, \rm{fT} \,{cm}^{-1}{Hz}^{-1/2}$ and common mode rejection ratio (CMRR) $> 150$ in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline, and for quickly assessing the advantage, if any, of performing a measurement in gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.
△ Less
Submitted 7 June, 2019;
originally announced June 2019.
-
Dual-axis pi-pulse spin-exchange relaxation-free magnetometer
Authors:
Elena Zhivun,
Michael Bulatowicz,
Alexander Hryciuk,
Thad Walker
Abstract:
We present a new spin-exchange relaxation-free vector magnetometer with suppressed 1/f probe noise, achieved by applying a small DC bias field and a comb of magnetic DC $π$ pulses along the pump direction. This results in a synchronous orthogonal AC response for each of its two sensitive axes. The new magnetometer is particularly well-suited to applications such as biomagnetism in which the signal…
▽ More
We present a new spin-exchange relaxation-free vector magnetometer with suppressed 1/f probe noise, achieved by applying a small DC bias field and a comb of magnetic DC $π$ pulses along the pump direction. This results in a synchronous orthogonal AC response for each of its two sensitive axes. The new magnetometer is particularly well-suited to applications such as biomagnetism in which the signal to be measured carries a dominant component of its power at low frequencies. The magnetometer reaches a technical noise floor of 8.4 fT/sqrt(Hz) (x) and 11 fT/sqrt(Hz) (y) at 0.01 Hz. A single-axis DC SERF sharing the same experimental apparatus attains 61 fT/sqrt(Hz) at the same frequency. A noise minimum of 1.1 fT/sqrt(Hz) (x) and 2.0 fT/sqrt(Hz) (y) is reached by the new magnetometer at 10 Hz, compared to 0.7 fT/sqrt(Hz) at 25 Hz for a DC SERF.
△ Less
Submitted 5 January, 2019; v1 submitted 30 May, 2018;
originally announced May 2018.
-
Synchronous Spin-Exchange Optical Pumping
Authors:
Anna Korver,
Daniel Thrasher,
Mike Bulatowicz,
Thad Walker
Abstract:
We describe a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR frequency shifts due to the alkali spin exchange field. The electronic spin polarization of optically pumped alkali atoms is square-wave modulated at the noble-gas NMR frequency and oriented transverse to the DC Fourier component of the NMR bias field. Noble gas NMR is driven by spin-exchange collisions…
▽ More
We describe a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR frequency shifts due to the alkali spin exchange field. The electronic spin polarization of optically pumped alkali atoms is square-wave modulated at the noble-gas NMR frequency and oriented transverse to the DC Fourier component of the NMR bias field. Noble gas NMR is driven by spin-exchange collisions with the oscillating electron spins. On resonance, the time-average torque from the oscillating spin-exchange field produced by the alkali spins is zero. Implementing the NMR bias field as a sequence of alkali 2$ π$-pulses enables synchronization of the alkali and noble gas spins despite a 1000-fold discrepancy in gyromagnetic ratio. We demonstrate this method with Rb and Xe, and observe novel NMR broadening effects due to the transverse oscillating spin exchange field. When uncompensated, the spin-exchange field at high density broadens the NMR linewidth by an order of magnitude, with an even more dramatic suppression (up to 70x) of the phase shift between the precessing alkali and Xe polarizations. When we introduce a transverse compensation field, we are able to eliminate the spin-exchange broadening and restore the usual NMR phase sensitivity. The projected quantum-limited sensitivity is better than 1 nHz/$\sqrt{\rm Hz}$.
△ Less
Submitted 29 June, 2015;
originally announced June 2015.
-
A Laboratory Search for a Long-Range T-odd, P-odd Interaction from Axion-Like Particles using Dual Species Nuclear Magnetic Resonance with Polarized Xe-129 and Xe-131 Gas
Authors:
M. Bulatowicz,
R. Griffith,
M. Larsen,
J. Mirijanian,
T. G. Walker,
C. B. Fu,
E. Smith,
W. M. Snow,
H. Yan
Abstract:
We place new limits on potential T- and P- violating monopole-dipole interactions between unpolarized nucleons and neutrons using dual species magnetic resonance in polarzed Xe gas. Free-induction decay transients with relaxation times ~20 s allow high precision measurements of the NMR frequencies, whose ratios cancel magnetic fluctuations. The new limits on the product gsgp improve on previous la…
▽ More
We place new limits on potential T- and P- violating monopole-dipole interactions between unpolarized nucleons and neutrons using dual species magnetic resonance in polarzed Xe gas. Free-induction decay transients with relaxation times ~20 s allow high precision measurements of the NMR frequencies, whose ratios cancel magnetic fluctuations. The new limits on the product gsgp improve on previous laboratory work by 2 orders of magnitude.
△ Less
Submitted 30 July, 2013; v1 submitted 22 January, 2013;
originally announced January 2013.