-
Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3 -- Ex vivo imaging: data processing, comparisons with microscopy, and tractography
Authors:
Kurt G Schilling,
Amy FD Howard,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij
, et al. (33 additional authors not shown)
Abstract:
Preclinical diffusion MRI (dMRI) has proven value in methods development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages that facilitat…
▽ More
Preclinical diffusion MRI (dMRI) has proven value in methods development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages that facilitate high spatial resolution and high signal-to-noise ratio (SNR) images, cutting-edge diffusion contrasts, and direct comparison with histological data as a methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging of small animals, but ultimately affect what questions can be answered using the data. This work concludes a 3-part series of recommendations and considerations for preclinical dMRI. Herein, we describe best practices for dMRI of ex vivo tissue, with a focus on image pre-processing, data processing and model fitting, and tractography. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist (and why), and where future work should lie. We end by providing guidelines on code sharing and data sharing, and point towards open-source software and databases specific to small animal and ex vivo imaging.
△ Less
Submitted 24 October, 2024;
originally announced November 2024.
-
Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging: added value and acquisition
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Amy FD Howard,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and enabling more advanced diffusion cont…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and enabling more advanced diffusion contrasts. Another major advantage of ex vivo dMRI is the direct comparison with histological data as a methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with decisions that not only differ dramatically from in vivo imaging of small animals, but ultimately affect what questions can be answered using the data. This work represents "Part 2" of a 3-part series of recommendations and considerations for preclinical dMRI. We describe best practices for dMRI of ex vivo tissue, with a focus on the value that ex vivo imaging adds to the field of dMRI and considerations in ex vivo image acquisition. We give general considerations and foundational knowledge that must be considered when designing experiments. We describe differences in specimens and models and discuss why some may be more or less appropriate for different studies. We then give guidelines for ex vivo protocols, including tissue fixation, sample preparation, and MR scanning. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist (and why), and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 24 October, 2024; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Considerations and Recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
Small-animal diffusion MRI (dMRI) has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the resultant data. This work aims…
▽ More
Small-animal diffusion MRI (dMRI) has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the resultant data. This work aims to present selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. We describe the general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss why some may be more or less appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, and imaging sequences, followed by advice for data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. In each section, we attempt to provide guides and recommendations, but also highlight areas for which no guidelines exist (and why), and where future work should focus. While we mainly cover the central nervous system (on which most preclinical dMRI studies are focused), we also provide, where possible and applicable, recommendations for other organs of interest. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 November, 2024; v1 submitted 26 September, 2022;
originally announced September 2022.
-
SnO/$β$-Ga2O3 vertical $pn$ heterojunction diodes
Authors:
Melanie Budde,
Daniel Splith,
Piero Mazzolini,
Abbes Tahraoui,
Johannes Feldl,
Manfred Ramsteiner,
Holger von Wenckstern,
Marius Grundmann,
Oliver Bierwagen
Abstract:
Vertical $pn$ heterojunction diodes were prepared by plasma-assisted molecular beam epitaxy of unintentionally-doped $p$-type SnO layers with hole concentrations ranging from $p=10^{18}$ to $10^{19}$cm$^{-3}$ on unintentionally-doped $n$-type $β$-Ga$_{2}$O$_{3}$(-201) substrates with an electron concentration of $n=2.0\times10^{17}$cm$^{-3}$. The SnO layers consist of (001)-oriented grains without…
▽ More
Vertical $pn$ heterojunction diodes were prepared by plasma-assisted molecular beam epitaxy of unintentionally-doped $p$-type SnO layers with hole concentrations ranging from $p=10^{18}$ to $10^{19}$cm$^{-3}$ on unintentionally-doped $n$-type $β$-Ga$_{2}$O$_{3}$(-201) substrates with an electron concentration of $n=2.0\times10^{17}$cm$^{-3}$. The SnO layers consist of (001)-oriented grains without in-plane expitaxial relation to the substrate. After subsequent contact processing and mesa etching (which drastically reduced the reverse current spreading in the SnO layer and associated high leakage) electrical characterization by current-voltage and capacitance-voltage measurement was performed. The results reveal a type-I band alignment and junction transport by thermionic emission in forward bias. A rectification of $2\times10^{8}$ at $\pm1$V, an ideality factor of 1.16, differential specific on-resistance of 3.9m$Ω\thinspace$cm$^{2}$, and built-in voltage of 0.96V were determined. The $pn$-junction isolation prevented parallel conduction in the highly-conductive Ga$_{2}$O$_{3}$ substrate (sheet resistance $R_{S}\approx3\thinspaceΩ$) during van-der-Pauw Hall measurements of the SnO layer on top ($R_{S}\approx150$k$Ω$, $p\approx2.5\times10^{18}$cm$^{-3}$, Hall mobility $\approx1$cm$^{2}$/Vs). The measured maximum reverse breakdown voltage of the diodes was 66V, corresponding to a peak breakdown field 2.2MV/cm in the Ga$_{2}$O$_{3}$-depletion region. Higher breakdown voltages that are required in high-voltage devices could be achieved by reducing the donor concentration in the $β$-Ga$_{2}$O$_{3}$ to increase the depletion width as well as improving the contact geometry to reduce field crowding.
△ Less
Submitted 1 October, 2020;
originally announced October 2020.
-
Structural, optical, and electrical properties of unintentionally doped NiO layers grown on MgO by plasma-assisted molecular beam epitaxy
Authors:
Melanie Budde,
Carsten Tschammer,
Philipp Franz,
Johannes Feldl,
Manfred Ramsteiner,
Rüdiger Goldhahn,
Martin Feneberg,
Nicolae Barsan,
Alexandru Oprea,
Oliver Bierwagen
Abstract:
NiO layers were grown on MgO(100), MgO(110), and MgO(111) substrates by plasma-assisted molecular beam epitaxy under Ni-flux limited growth conditions. Single crystalline growth with a cube-on-cube epitaxial relationship was confirmed by X-ray diffraction measurements for all used growth conditions and substrates except MgO(111). A detailed growth series on MgO(100) was prepared using substrate te…
▽ More
NiO layers were grown on MgO(100), MgO(110), and MgO(111) substrates by plasma-assisted molecular beam epitaxy under Ni-flux limited growth conditions. Single crystalline growth with a cube-on-cube epitaxial relationship was confirmed by X-ray diffraction measurements for all used growth conditions and substrates except MgO(111). A detailed growth series on MgO(100) was prepared using substrate temperatures ranging from 20 °C to 900 °C to investigate the influence on the layer characteristics. Energy-dispersive X-ray spectroscopy indicated close-to-stoichiometric layers with an oxygen content of ~47 at. % and ~50 at. % grown under low and high O-flux, respectively. All NiO layers had a root-mean-square surface roughness below 1 nm, measured by atomic force microscopy, except for rougher layers grown at 900 °C or using molecular oxygen. Growth at 900 °C led to a significant diffusion of Mg from the substrate into the film. The relative intensity of the quasi-forbidden one-phonon Raman peak is introduced as a gauge of the crystal quality, indicating the highest layer quality for growth at low oxygen flux and high growth temperature, likely due to the resulting high adatom diffusion length during growth. The optical and electrical properties were investigated by spectroscopic ellipsometry and resistance measurements, respectively. All NiO layers were transparent with an optical bandgap around 3.6 eV and semi-insulating at room temperature. However, changes upon exposure to reducing or oxidizing gases of the resistance of a representative layer at elevated temperature were able to confirm p-type conductivity, highlighting their suitability as a model system for research on oxide-based gas sensing.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Plasma-assisted molecular beam epitaxy of NiO on GaN(00.1)
Authors:
Melanie Budde,
Thilo Remmele,
Carsten Tschammer,
Johannes Feldl,
Philipp Franz,
Jonas Lähnemann,
Zongzhe Cheng,
Michael Hanke,
Manfred Ramsteiner,
Martin Albrecht,
Oliver Bierwagen
Abstract:
The growth of NiO on GaN(00.1) substrates by plasma-assisted molecular beam epitaxy under oxygen rich conditions was investigated at growth temperatures between 100 $^{\circ}$C and 850 $^{\circ}$C. Epitaxial growth of NiO(111) with two rotational domains, with epitaxial relation $\normalsize{}\mathrm{\mathrm{\mathrm{NiO}(1\bar{\mathrm{1}}0)}\:||\:\mathrm{\mathrm{GaN}(11.0)}}$ and…
▽ More
The growth of NiO on GaN(00.1) substrates by plasma-assisted molecular beam epitaxy under oxygen rich conditions was investigated at growth temperatures between 100 $^{\circ}$C and 850 $^{\circ}$C. Epitaxial growth of NiO(111) with two rotational domains, with epitaxial relation $\normalsize{}\mathrm{\mathrm{\mathrm{NiO}(1\bar{\mathrm{1}}0)}\:||\:\mathrm{\mathrm{GaN}(11.0)}}$ and $\mathrm{\mathrm{\mathrm{NiO}\mathrm{(10\bar{\mathrm{1}})}\:||\:\mathrm{GaN(11.0)}}}$, was observed by X-ray diffraction (XRD) and confirmed by in-situ reflection high-energy electron diffraction as well as transmission electron microscopy (TEM) and electron backscatter diffraction. With respect to the high lattice mismatch of 8.1 % and a measured low residual tensile layer strain, growth by lattice matching epitaxy or domain matching epitaxy is discussed. The morphology measured by atomic force microscopy showed a grainy surface, probably arising from the growth by the columnar rotational domains visible in TEM micrographs. The domain sizes measured by AFM and TEM increase with the growth temperature, indicating an increasing surface diffusion length. Growth at 850 $^{\circ}$C, however, involved local decomposition of the GaN substrate that lead to an interfacial $\mathrmβ$-Ga$\mathrm{_{2}}$O$\mathrm{_{3}}$($\bar{\mathrm{2}}$01) layer and a high NiO surface roughness. Raman mesurements of the quasi-forbidden one-phonon peak indicate increasing layer quality (decreasing defect density) with increasing growth temperature. The results above suggest optimum growth temperatures around 700 $^{\circ}$C for high layer and interface quality.
△ Less
Submitted 7 January, 2020; v1 submitted 17 October, 2019;
originally announced October 2019.
-
Mixing of ultracold atomic clouds by merging of two magnetic traps
Authors:
Jesper Fevre Bertelsen,
Henrik Kjaer Andersen,
Sune Mai,
Michael Budde
Abstract:
We demonstrate a method to make mixtures of ultracold atoms that does not make use of a two-species magneto-optical trap. We prepare two clouds of 87Rb atoms in distinct magnetic quadrupole traps and mix the two clouds by merging the traps. For correctly chosen parameters the mixing can be done essentially without loss of atoms and with only minor heating. The basic features of the process can b…
▽ More
We demonstrate a method to make mixtures of ultracold atoms that does not make use of a two-species magneto-optical trap. We prepare two clouds of 87Rb atoms in distinct magnetic quadrupole traps and mix the two clouds by merging the traps. For correctly chosen parameters the mixing can be done essentially without loss of atoms and with only minor heating. The basic features of the process can be accounted for by a classical simulation of particle trajectories. Such calculations indicate that mixing of different mass species is also feasible, opening the way for using the method as a starting point for making quantum gas mixtures.
△ Less
Submitted 18 February, 2007; v1 submitted 15 June, 2006;
originally announced June 2006.