Feasibility of the J-PET to monitor range of therapeutic proton beams
Authors:
Jakub Baran,
Damian Borys,
Karol Brzeziński,
Jan Gajewski,
Michał Silarski,
Neha Chug,
Aurélien Coussat,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Kavya V. Eliyan,
Aleksander Gajos Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Renata Kopeć,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Antony J. Lomax,
Keegan McNamara,
Szymon Niedźwiecki,
Paweł Olko,
Dominik Panek
, et al. (18 additional authors not shown)
Abstract:
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot…
▽ More
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Authors:
R. Y. Shopa,
J. Baran,
K. Klimaszewski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
K. Brzeziński,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. C. Hiesmayr,
E. Kavya Valsan,
G. Korcyl,
T. Kozik,
D. Kumar,
Ł. Kapłon,
G. Moskal,
S. Niedźwiecki,
D. Panek,
S. Parzych
, et al. (10 additional authors not shown)
Abstract:
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of…
▽ More
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
△ Less
Submitted 8 August, 2024; v1 submitted 6 February, 2023;
originally announced February 2023.