-
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
Authors:
M. Szydagis,
J. Balajthy,
G. A. Block,
J. P. Brodsky,
E. Brown,
J. E. Cutter,
S. J. Farrell,
J. Huang,
A. C. Kamaha,
E. S. Kozlova,
C. S. Liebenthal,
D. N. McKinsey,
K. McMichael,
R. McMonigle,
M. Mooney,
J. Mueller,
K. Ni,
G. R. C. Rischbieter,
K. Trengove,
M. Tripathi,
C. D. Tunnell,
V. Velan,
S. Westerdale,
M. D. Wyman,
Z. Zhao
, et al. (1 additional authors not shown)
Abstract:
This paper will discuss the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describe experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background will be presented using the Noble Element Simulation Technique (NEST),…
▽ More
This paper will discuss the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describe experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background will be presented using the Noble Element Simulation Technique (NEST), which is a toolkit based on experimental data and simple, empirical formulae, which mimic previous microphysics modeling, but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field will be reviewed, as well as models for energy resolution and final pulse areas. NEST will be compared to other models or sets of models, and vetted against real data, with several specific examples pulled from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.
△ Less
Submitted 19 December, 2024; v1 submitted 19 November, 2022;
originally announced November 2022.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
The Architected Multi-material Scintillator System: Designs and Modeling
Authors:
Xianyi Zhang,
Jason Philip Brodsky,
Elaine Lee,
Andrew Neil Mabe,
Dominique Porcincula
Abstract:
We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring differently-dyed materials, the wavelength of the scintillation light encodes additional information in radiation measurements. These structures can be realized th…
▽ More
We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring differently-dyed materials, the wavelength of the scintillation light encodes additional information in radiation measurements. These structures can be realized through additive manufacture (3D-printing). Two classes of this concept are described and modelled using Monte Carlo simulations to evaluate their performance. The first detector design uses dye microstructures to encode particle tracking information, allowing for directional neutron detection and gamma/neutron discrimination. The second design uses a dye gradient to indicate the position of radiation along the gradient. The simulation results indicate this new concept in radiation detection can achieve strong performance in a variety of capabilities including particle identification, directionality and spectroscopy measurements, and particle position reconstruction.
△ Less
Submitted 9 March, 2021; v1 submitted 3 March, 2021;
originally announced March 2021.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
M. Febbraro,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
B. T. Hackett,
S. Hans
, et al. (40 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at…
▽ More
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.
△ Less
Submitted 16 August, 2019; v1 submitted 17 June, 2019;
originally announced June 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
A. E. Detweiler M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
Y. Gebre,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of…
▽ More
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.
△ Less
Submitted 9 April, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
C. Camilo Reyes,
S. Campos,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
R. Diaz Perez,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust
, et al. (45 additional authors not shown)
Abstract:
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a…
▽ More
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.
△ Less
Submitted 27 March, 2019; v1 submitted 16 January, 2019;
originally announced January 2019.
-
Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays…
▽ More
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.
△ Less
Submitted 28 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
Background Discrimination for Neutrinoless Double Beta Decay in Liquid Xenon Using Cherenkov Light
Authors:
Jason Philip Brodsky,
Samuele Sangiorgio,
Michael Heffner,
Tyana Stiegler
Abstract:
Neutrinoless double beta decays in liquid xenon produce a significant amount of Cherenkov light, with a photon number and angular distribution that distinguishes these events from common backgrounds. A GEANT4 simulation was used to simulate Cherenkov photon production and measurement in a liquid xenon detector and a multilayer perceptron was used to analyze the resulting distributions to classify…
▽ More
Neutrinoless double beta decays in liquid xenon produce a significant amount of Cherenkov light, with a photon number and angular distribution that distinguishes these events from common backgrounds. A GEANT4 simulation was used to simulate Cherenkov photon production and measurement in a liquid xenon detector and a multilayer perceptron was used to analyze the resulting distributions to classify events based on their Cherenkov photons. Our results show that a modest improvement in the sensitivity of neutrinoless double beta decay searches is possible using this technique, but the kinematics of the neutrinoless double beta decay and electron scattering in liquid xenon substantially limit this approach.
△ Less
Submitted 13 December, 2018;
originally announced December 2018.
-
The PROSPECT Reactor Antineutrino Experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
C. Baldenegro,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. Boyle,
J. Bricco,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski
, et al. (64 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reacto…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.
△ Less
Submitted 21 August, 2019; v1 submitted 31 July, 2018;
originally announced August 2018.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment
Authors:
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
D. Davee,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
B. Hackett,
K. Han
, et al. (41 additional authors not shown)
Abstract:
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source a…
▽ More
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy resolution of $σ$ = 4.0$\pm$0.2% at 1 MeV, and efficient pulse-shape discrimination of low $dE/dx$ (electronic recoil) and high $dE/dx$ (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85$\pm$3 cm is measured in each segment. The 0.1% by mass concentration of $^{6}$Li in the scintillator results in a measured neutron capture time of $τ$ = 42.8$\pm$0.2 $μs$. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.
△ Less
Submitted 29 June, 2018; v1 submitted 23 May, 2018;
originally announced May 2018.
-
Characterization of an Ionization Readout Tile for nEXO
Authors:
nEXO Collaboration,
M. Jewell,
A. Schubert,
W. R. Cen,
J. Dalmasson,
R. DeVoe,
L. Fabris,
G. Gratta,
A. Jamil,
G. Li,
A. Odian,
M. Patel,
A. Pocar,
D. Qiu,
Q. Wang,
L. J. Wen,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky
, et al. (120 additional authors not shown)
Abstract:
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale n…
▽ More
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a $^{207}$Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution $σ/E$=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.
△ Less
Submitted 19 January, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay
Authors:
nEXO Collaboration,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
M. Côté,
A. Craycraft,
W. Cree,
J. Dalmasson
, et al. (121 additional authors not shown)
Abstract:
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by…
▽ More
The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0νββ$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
△ Less
Submitted 19 October, 2018; v1 submitted 13 October, 2017;
originally announced October 2017.
-
The PROSPECT Physics Program
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
C. D. Bryan,
J. P. Brodsky,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
B. W. Goddard
, et al. (39 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ν_e$ disappearance experiments at 4$σ$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$σ$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$σ$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
Light Collection and Pulse-Shape Discrimination in Elongated Scintillator Cells for the PROSPECT Reactor Antineutrino Experiment
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn
, et al. (41 additional authors not shown)
Abstract:
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been stu…
▽ More
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.