-
Direct estimation of global longitudinal strain from echocardiograms using a logarithm-scaled Fourier magnitude correlation
Authors:
Brett A. Meyers,
Melissa C. Brindise,
Vivek Jani,
Shelby Kutty,
Pavlos P. Vlachos
Abstract:
We present a new method for measuring global longitudinal strain and global longitudinal strain rate from 2D echocardiograms using a logarithmic-transform correlation (LTC) method. In contrast to traditional echocardiography strain analysis, our approach does not require cardiac chamber segmentation and regularization. The algorithm was benchmarked against two conventional strain analysis methods…
▽ More
We present a new method for measuring global longitudinal strain and global longitudinal strain rate from 2D echocardiograms using a logarithmic-transform correlation (LTC) method. In contrast to traditional echocardiography strain analysis, our approach does not require cardiac chamber segmentation and regularization. The algorithm was benchmarked against two conventional strain analysis methods using synthetic left ventricle ultrasound images. Measurement error was assessed as a function of contrast-to-noise ratio (CNR) using mean absolute error and root-mean-square error and showed better agreement to the ground truth for strain($R^2$ = 0.91) and strain rate($R^2$ = 0.85) as compared to conventional algorithms (strain($R^2$ = 0.7), strain rate($R^2$ = 0.7)). Also, our method was unaffected by CNR. A 200% increase in strain measurement accuracy was observed compared to the conventional algorithms. Subsequently, we tested the method using a 54-subject clinical cohort (20 subjects diseased with cardiomyopathy, 34 healthy controls). Our method distinguished between normal and abnormal left ventricular function with an AUC = 0.85, a 10% improvement over the conventional GLS algorithms.
△ Less
Submitted 24 May, 2021; v1 submitted 25 March, 2020;
originally announced March 2020.
-
4D-Flow MRI Pressure Estimation Using Velocity Measurement-Error based Weighted Least-Squares
Authors:
Jiacheng Zhang,
Melissa C. Brindise,
Sean Rothenberger,
Susanne Schnell,
Michael Markl,
David Saloner,
Vitaliy L. Rayz,
Pavlos P. Vlachos
Abstract:
This work introduces a 4D-flow magnetic resonance imaging (MRI) pressure reconstruction method which employs weighted least-squares (WLS) for pressure integration. Pressure gradients are calculated from the velocity fields, and velocity errors are estimated from the velocity divergence for incompressible flow. Pressure gradient errors are estimated by propagating the velocity errors through Navier…
▽ More
This work introduces a 4D-flow magnetic resonance imaging (MRI) pressure reconstruction method which employs weighted least-squares (WLS) for pressure integration. Pressure gradients are calculated from the velocity fields, and velocity errors are estimated from the velocity divergence for incompressible flow. Pressure gradient errors are estimated by propagating the velocity errors through Navier-Stokes momentum equation. A weight matrix is generated based on the pressure gradient errors, then employed for pressure reconstruction. The pressure reconstruction method was demonstrated and analyzed using synthetic velocity fields as well as Poiseuille flow measured using in vitro 4D-flow MRI. Performance of the proposed WLS method was compared to the method of solving the pressure Poisson equation which has been the primary method used in the previous studies. Error analysis indicated that the proposed method is more robust to velocity measurement errors. Improvement on pressure results was found to be more significant for the cases with spatially-varying velocity error level, with reductions in error ranging from 50% to over 200%. Finally, the method was applied to flow in a patient-specific cerebral aneurysm. Validation was performed with in vitro flow data collected using Particle Tracking Velocimetry (PTV) and Shake the Box (STB) method, and in vivo flow measurement obtained using 4D-flow MRI. Pressure calculated by WLS, as opposed to the Poisson equation, was more consistent with the flow structures and showed better agreement between the in vivo and in vitro data. These results suggest the utility of WLS method to obtain reliable pressure field from clinical flow measurement data.
△ Less
Submitted 30 April, 2019;
originally announced April 2019.
-
Patient-Specific Cerebral Aneurysm Hemodynamics: Comparison of in vitro Volumetric Particle Velocimetry, Computational Fluid Dynamics (CFD), and in vivo 4D Flow MRI
Authors:
Melissa C. Brindise,
Sean Rothenberger,
Benjamin Dickerhoff,
Susanne Schnell,
Michael Markl,
David Saloner,
Vitaliy L. Rayz,
Pavlos P. Vlachos
Abstract:
Typical approaches to patient-specific hemodynamic studies of cerebral aneurysms use image based computational fluid dynamics (CFD) and seek to statistically correlate parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) to risk of growth and rupture. However, such studies have reported contradictory results, emphasizing the need for in-depth comparisons of volumetric exper…
▽ More
Typical approaches to patient-specific hemodynamic studies of cerebral aneurysms use image based computational fluid dynamics (CFD) and seek to statistically correlate parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) to risk of growth and rupture. However, such studies have reported contradictory results, emphasizing the need for in-depth comparisons of volumetric experiments and CFD. In this work, we conducted tomographic particle velocimetry experiments using two patient-specific cerebral aneurysm models (basilar tip and internal carotid artery) under pulsatile flow conditions and processed the particle images using Shake the Box (STB), a particle tracking method. The STB data was compared to that obtained from in vivo 4D flow MRI and CFD. Although qualitative agreement of flow pathlines across modalities was observed, each modality maintained notably unique spatiotemporal distributions of low normalized WSS regions. Analysis of time averaged WSS (TAWSS), OSI, and Relative Residence Time (RRT) demonstrated that non-dimensional parameters, such as OSI, may be more robust to the varying assumptions, limitations, and spatial resolutions of each subject and modality. These results suggest a need for further multi-modality analysis as well as development of non-dimensional hemodynamic parameters and correlation of such metrics to aneurysm risk of growth and rupture.
△ Less
Submitted 4 March, 2019;
originally announced March 2019.
-
Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: an in vitro study
Authors:
Melissa C. Brindise,
Claudio Chiastra,
Francesco Burzotta,
Francesco Migliavacca,
Pavlos P. Vlachos
Abstract:
Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions w…
▽ More
Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions were investigated experimentally. Three implantation methods, provisional side branch (PSB), culotte (CUL), and crush (CRU), were investigated using time-resolved particle image velocimetry (PIV) to measure the velocity fields. Subsequently, hemodynamic parameters including wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated and the pressure field through the vessel was non-invasively quantified. The effects of each stented case were evaluated and compared against an un-stented case. CRU provided the lowest compliance mismatch, but demonstrated detrimental stent interactions. PSB, the clinically preferred method, and CUL maintained many normal flow conditions. However, PSB provided about a 300% increase in both OSI and RRT. CUL yielded a 10% and 85% increase in OSI and RRT, respectively. The results of this study support the concept that different bifurcation stenting techniques result in hemodynamic environments that deviate from that of un-stented bifurcations, to varying degrees.
△ Less
Submitted 10 March, 2016;
originally announced March 2016.