-
Automatizing the search for mass resonances using BumpNet
Authors:
Jean-Francois Arguin,
Georges Azuelos,
Émile Baril,
Ilan Bessudo,
Fannie Bilodeau,
Maryna Borysova,
Shikma Bressler,
Samuel Calvet,
Julien Donini,
Etienne Dreyer,
Michael Kwok Lam Chu,
Eva Mayer,
Ethan Meszaros,
Nilotpal Kakati,
Bruna Pascual Dias,
Joséphine Potdevin,
Amit Shkuri,
Muhammad Usman
Abstract:
The search for resonant mass bumps in invariant-mass distributions remains a cornerstone strategy for uncovering Beyond the Standard Model (BSM) physics at the Large Hadron Collider (LHC). Traditional methods often rely on predefined functional forms and exhaustive computational and human resources, limiting the scope of tested final states and selections. This work presents BumpNet, a machine lea…
▽ More
The search for resonant mass bumps in invariant-mass distributions remains a cornerstone strategy for uncovering Beyond the Standard Model (BSM) physics at the Large Hadron Collider (LHC). Traditional methods often rely on predefined functional forms and exhaustive computational and human resources, limiting the scope of tested final states and selections. This work presents BumpNet, a machine learning-based approach leveraging advanced neural network architectures to generalize and enhance the Data-Directed Paradigm (DDP) for resonance searches. Trained on a diverse dataset of smoothly-falling analytical functions and realistic simulated data, BumpNet efficiently predicts statistical significance distributions across varying histogram configurations, including those derived from LHC-like conditions. The network's performance is validated against idealized likelihood ratio-based tests, showing minimal bias and strong sensitivity in detecting mass bumps across a range of scenarios. Additionally, BumpNet's application to realistic BSM scenarios highlights its capability to identify subtle signals while managing the look-elsewhere effect. These results underscore BumpNet's potential to expand the reach of resonance searches, paving the way for more comprehensive explorations of LHC data in future analyses.
△ Less
Submitted 9 January, 2025;
originally announced January 2025.
-
Discharge quenching mechanism and performance of RPWELL with tunable 3D printed resistive plates, charge evacuation in semiconductive glass RPWELL and discharge quenching for Cryogenic-RWELL over a wide range of resistivity
Authors:
Abhik Jash,
Luca Moleri,
Andrea Tesi,
Shikma Bressler
Abstract:
Resistive electrodes are used in gaseous detectors to quench electrical discharges. This helps to protect delicate electrodes and readout electronics and to improve the stability of the detector operation. An RPWELL is a THGEM-based WELL detector with a resistive plate coupled to a conductive anode. Till now, the choice of the resistive plate was limited to a few materials, like LRS Glass and Semi…
▽ More
Resistive electrodes are used in gaseous detectors to quench electrical discharges. This helps to protect delicate electrodes and readout electronics and to improve the stability of the detector operation. An RPWELL is a THGEM-based WELL detector with a resistive plate coupled to a conductive anode. Till now, the choice of the resistive plate was limited to a few materials, like LRS Glass and Semitron. These materials have fixed resistivities and, sometimes, thickness and area limitations. This restricts the potential usage of the detector to a rather small range of applications, as well as the possibility of studying in depth the physics processes governing the discharge quenching mechanism. In our present study, we used a new plastic material doped with carbon nanotubes to produce resistive plates with a commercial 3D printer. This method has the flexibility to produce samples of different thicknesses and different resistivity values. We describe here the sample production and characterize the RPWELL performance with different resistive plates. In particular we show the dependence of discharge quenching on the thickness and resistivity of the plate. The dynamics of the charge carriers in the material is proposed as an explanation for the long gain recovery time after a discharge.
△ Less
Submitted 13 June, 2024; v1 submitted 28 January, 2024;
originally announced January 2024.
-
Cryogenic RPWELL: a novel charge-readout element for dual-phase argon TPCs
Authors:
A. Tesi,
S. Leardini,
L. Moleri,
M. Morales,
D. Gonzalez-Diaz,
A. Jash,
A. Breskin,
S. Bressler
Abstract:
The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $Ω\cdot$cm. The detector w…
▽ More
The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $Ω\cdot$cm. The detector was operated at liquid argon temperature in saturated argon vapor (90~K, 1.2~bar) and characterized in terms of its effective charge gain and stability against discharges. Maximum stable gain of G$\approx$17 was obtained, without discharges. In addition, preliminary results from novel 3D-printed thermoplastic plates doped with carbon nanotubes are presented.
△ Less
Submitted 11 December, 2023;
originally announced December 2023.
-
The cryogenic RWELL: a stable charge multiplier for dual-phase liquid-argon detectors
Authors:
A. Tesi,
S. Leardini,
L. Moleri,
D. Gonzalez-Diaz,
A. Jash,
A. Breskin,
S. Bressler
Abstract:
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain an…
▽ More
The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain and electrical stability. A comparative study with standard, non-resistive THGEM (a.k.a LEM) and WELL multipliers, confirmed the RWELL advantages in terms of discharge quenching - thus superior gain and stability.
△ Less
Submitted 26 September, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Towards a large-area RPWELL detector: design optimization and performance
Authors:
D. Zavazieva,
L. Moleri,
A. Jash,
G. Sela,
F. de Vito-Halevy,
S. Bressler
Abstract:
We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved performances compared to previous ones: MIP detection efficiency over 96\% with 3\% uniformity across the entire detector area, a charge gain of…
▽ More
We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved performances compared to previous ones: MIP detection efficiency over 96\% with 3\% uniformity across the entire detector area, a charge gain of $\mathrm{\approx{7.5 \times 10^3}}$ with a uniformity of 22\%, and discharge probability below $\mathrm{10^{-6}}$ with a few single hotspots attributed to production imperfections. These results pave the way towards further up-scaling detectors of this kind.
△ Less
Submitted 18 July, 2023; v1 submitted 3 May, 2023;
originally announced May 2023.
-
Novel resistive charge-multipliers for dual-phase LAr-TPCs: towards stable operation at higher gains
Authors:
A. Tesi,
L. Moleri,
S. Leardini,
A. Breskin,
D. Gonzalez-Diaz,
L. Olano-Vegas,
A. Jash,
S. Bressler
Abstract:
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to t…
▽ More
Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to the THGEM. Radiation-induced ionization electrons in the liquid are extracted into the gaseous phase. They drift into the THGEM's holes where they undergo charge multiplication. Embedding resistive materials into the multiplier proved to enhance operation stability due to the mitigation of electrical discharges - thus allowing operation at higher charge gain compared to standard THGEM (a.k.a. LEM) multipliers. We present the detector concepts and report on the main preliminary results.
△ Less
Submitted 21 May, 2023; v1 submitted 8 April, 2023;
originally announced April 2023.
-
The Thick Gas Electron Multiplier and its derivatives: physics, technologies and applications
Authors:
Shikma Bressler,
Luca Moleri,
Abhik Jash,
Andrea Tesi,
Darina Zavazieva
Abstract:
The Thick Gas Electron Multiplier (THGEM) is a robust high-gain gas-avalanche electron multiplier - a building block of a variety of radiation detectors. It can be manufactured economically by standard printed-circuit drilling and etching technology. We present a detailed review of the THGEM and its derivatives. We focus on the physics phenomena that govern their operation and performances under d…
▽ More
The Thick Gas Electron Multiplier (THGEM) is a robust high-gain gas-avalanche electron multiplier - a building block of a variety of radiation detectors. It can be manufactured economically by standard printed-circuit drilling and etching technology. We present a detailed review of the THGEM and its derivatives. We focus on the physics phenomena that govern their operation and performances under different operation conditions. Technological aspects associated with the production of these detectors and their current and potential applications are discussed.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Letter of Intent: the NA60+ experiment
Authors:
C. Ahdida,
G. Alocco,
F. Antinori,
M. Arba,
M. Aresti,
R. Arnaldi,
A. Baratto Roldan,
S. Beole,
A. Beraudo,
J. Bernhard,
L. Bianchi,
M. Borysova,
S. Bressler,
S. Bufalino,
E. Casula,
C. Cicalo,
S. Coli,
P. Cortese,
A. Dainese,
H. Danielsson,
A. De Falco,
K. Dehmelt,
A. Drees,
A. Ferretti,
F. Fionda
, et al. (37 additional authors not shown)
Abstract:
We propose a new fixed-target experiment for the study of electromagnetic and hard probes of the Quark-Gluon Plasma (QGP) in heavy-ion collisions at the CERN SPS. The experiment aims at performing measurements of the dimuon spectrum from threshold up to the charmonium region, and of hadronic decays of charm and strange hadrons. It is based on a muon spectrometer, which includes a toroidal magnet a…
▽ More
We propose a new fixed-target experiment for the study of electromagnetic and hard probes of the Quark-Gluon Plasma (QGP) in heavy-ion collisions at the CERN SPS. The experiment aims at performing measurements of the dimuon spectrum from threshold up to the charmonium region, and of hadronic decays of charm and strange hadrons. It is based on a muon spectrometer, which includes a toroidal magnet and six planes of tracking detectors, coupled to a vertex spectrometer, equipped with Si MAPS immersed in a dipole field. High luminosity is an essential requirement for the experiment, with the goal of taking data with 10$^6$ incident ions/s, at collision energies ranging from $\sqrt{s_{\rm NN}} = 6.3$ GeV ($E_{\rm lab}= 20$ A GeV) to top SPS energy ($\sqrt{s_{\rm NN}} = 17.3$ GeV, $E_{\rm lab}= 158$ A GeV). This document presents the physics motivation, the foreseen experimental set-up including integration and radioprotection studies, the current detector choices together with the status of the corresponding R&D, and the outcome of physics performance studies. A preliminary cost evaluation is also carried out.
△ Less
Submitted 29 December, 2022;
originally announced December 2022.
-
Diamond-like carbon coatings for cryogenic operation of particle detectors
Authors:
Sara Leardini,
Yi Zhou,
Andrea Tesi,
Miguel Morales,
Diego González-Díaz,
Amos Breskin,
Shikma Bressler,
Luca Moleri,
Vladimir Peskov
Abstract:
Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5 Mohm/sq. The good behaviour observed in terms of linearity, surface uniformity and stability with time and transported charge add to other well-known characteristics l…
▽ More
Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5 Mohm/sq. The good behaviour observed in terms of linearity, surface uniformity and stability with time and transported charge add to other well-known characteristics like low chemical reactivity and tolerance to radiation. The observed temperature dependence and stability of electrical properties with transported charge is consistent with a conductivity mechanism based on 2-dimensional variable-range electron hopping, as expected for the surface conductivity of thin films made from amorphous carbon. First results from a resistive-protected WELL detector ('RWELL') built with DLC and operated close to the liquid-vapor coexistence point of argon (87.5 K at 1 bar) are presented.
△ Less
Submitted 22 January, 2023; v1 submitted 30 September, 2022;
originally announced September 2022.
-
Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Authors:
Dan Shaked-Renous,
Fernando Domingues Amaro,
Purba Bhattacharya,
Amos Breskin,
Maximilien Chefdeville,
Cyril Drancourt,
Theo Geralis,
Yannis Karyotakis,
Luca Moleri,
Andrea Tesi,
Maxim Titov,
Joao Veloso,
Guillaum Vouters,
Shikma Bressler
Abstract:
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average…
▽ More
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies focusing on Micro-Pattern Gaseous Detector (MPGD)-based sampling elements have shown the potential advantages; they can be operated with environmental friendly gases and reach similar detection efficiency at lower average pad-multiplicity. We summarize here the experimental test-beam results of a small-size DHCAL prototype, incorporating six Micromegas (MM) and two Resistive-Plate WELL (RPWELL) sampling elements, interlaced with steel-absorber plates. It was investigated with 2-6 GeV pion beam at the CERN/PS beam facility. The data permitted validating a GEANT4 simulation framework of a DHCAL, and evaluating the expected pion energy resolution of a full-scale RPWELL-based calorimeter. The pion energy resolution of $\fracσ{E[GeV]}=\frac{50.8\%}{\sqrt{E[GeV]}} \oplus 10.3\%$ derived expected with the RPWELL concept is competitive to that of glass RPC and MM sampling techniques.
△ Less
Submitted 7 October, 2022; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Electrical breakdown in Thick-GEM based WELL detectors
Authors:
Abhik Jash,
Luca Moleri,
Shikma Bressler
Abstract:
The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector assembly was found to be very effective. In this work, we present the results of a comparative study of electrical discharges in Thick-GEM-based WELL-type detectors…
▽ More
The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector assembly was found to be very effective. In this work, we present the results of a comparative study of electrical discharges in Thick-GEM-based WELL-type detectors - with and without resistive elements. We present a new method to measure discharges in the resistive-detector configurations; it allows demonstrating, for the first time, the occurrence of discharges also in the Resistive-Plate WELL detector configuration. It also provides direct evidence for the Raether limit.
△ Less
Submitted 28 August, 2022; v1 submitted 20 April, 2022;
originally announced April 2022.
-
Bubble dynamics in Liquid Hole Multipliers
Authors:
A. Tesi,
E. Segre,
S. Leardini,
A. Breskin,
S. Kapishnikov,
L. Moleri,
D. Vartsky,
S. Bressler
Abstract:
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the f…
▽ More
In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the first time bubbles were optically observed in LAr; their properties were studied in contact with different material surfaces. This permitted investigating the bubble-electrodynamics via numerical simulations; it was shown that the electric field acts as an additional pressure term on the bubble meniscus. The predictions for the liquid-to-gas interface were successfully validated using X-ray micro-CT in water and in silicone oil at STP. The proposed model and the results of this study are an important milestone towards understanding and optimizing the parameters of LHM-based noble-liquid detectors.
△ Less
Submitted 26 July, 2021;
originally announced August 2021.
-
A symbolic information approach to characterize response-related differences in cortical activity during a Go/No-Go task
Authors:
Helena B. Lucas,
Steven L. Bressler,
Fernanda S. Matias,
Osvaldo A. Rosso
Abstract:
How the brain processes information from external stimuli in order to perceive the world and act on it is one of the greatest questions in neuroscience. To address this question different time series analyzes techniques have been employed to characterize the statistical properties of brain signals during cognitive tasks. Typically response-specific processes are addressed by comparing the time cou…
▽ More
How the brain processes information from external stimuli in order to perceive the world and act on it is one of the greatest questions in neuroscience. To address this question different time series analyzes techniques have been employed to characterize the statistical properties of brain signals during cognitive tasks. Typically response-specific processes are addressed by comparing the time course of average event-related potentials in different trials type. Here we analyze monkey Local Field Potentials data during visual pattern discrimination called Go/No-Go task in the light of information theory quantifiers. We show that the Bandt-Pompe symbolization methodology to calculate entropy and complexity of data is a useful tool to distinguish response-related differences between Go and No-Go trials. We propose to use an asymmetry index to statistically validate trial type differences. Moreover, by using the multi-scale approach and embedding time delays to downsample the data we can estimate the important time scales in which the relevant information is been processed.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Single Electron Spectra in RPWELL-based detectors
Authors:
Purba Bhattacharya,
Andrea Tesi,
Dan Shaked-Renous,
Luca Moleri,
Amos Breskin,
Shikma Bressler
Abstract:
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic…
▽ More
Single-electron avalanche distributions in gaseous multipliers affect their efficient detection and that of single UV-photons. In this work, we investigated the shape of single-photo-electron spectra in single- and double-stage Resistive Plate WELL (RPWELL) detector configurations, operated in $\mathrm{Ne/CH_{4}}$ and $\mathrm{Ar/CH_{4}}$. Discharge-free operation was reached over a broad dynamic range, with charge gains of \numrange[range-phrase = -]{e4}{e6}. Compared to the usual exponential ones, the observed Polya-like charge spectra pave the way towards higher single-electrons detection efficiencies. The latter were evaluated here, using experimental data combined with numerical simulations. The effects of the gas mixtures, electric field configuration and detector geometry on the Polya spectra and their related "$θ$" parameter are presented.
△ Less
Submitted 21 June, 2021; v1 submitted 5 January, 2021;
originally announced January 2021.
-
Bubble-assisted Liquid Hole Multipliers in LXe and LAr: towards "local dual-phase TPCs"
Authors:
E. Erdal,
L. Arazi,
A. Breskin,
S. Shchemelinin,
A. Roy,
A. Tesi,
D. Vartsky,
S. Bressler
Abstract:
The bubble-assisted Liquid Hole Multiplier (LHM) is a novel concept for the combined detection of ionization electrons and scintillation photons in noble-liquid time projection chambers. It consists of a perforated electrode immersed in the noble liquid, with heating wires generating a stable bubble underneath. Radiation-inducted ionization electrons in the liquid drift into the electrode's holes…
▽ More
The bubble-assisted Liquid Hole Multiplier (LHM) is a novel concept for the combined detection of ionization electrons and scintillation photons in noble-liquid time projection chambers. It consists of a perforated electrode immersed in the noble liquid, with heating wires generating a stable bubble underneath. Radiation-inducted ionization electrons in the liquid drift into the electrode's holes and cross the liquid-vapor interface into the bubble where they induce electroluminescence (EL). The top surface of the electrode is optionally coated with a CsI photocathode; radiation-induced UV-scintillation photons extract photoelectrons that induce EL in a similar way. EL-photons recorded with an array of photosensors, e.g. SiPMs, provide event localization. We present the basic principles of the LHM and summarize the results obtained in LXe and LAr.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
First demonstration of a bubble-assisted Liquid Hole Multiplier operation in liquid argon
Authors:
Eran Erdal,
Andrea Tesi,
Amos Breskin,
David Vartsky,
Shikma Bressler
Abstract:
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emit…
▽ More
We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emitted from a photocathode on the electrode's surface, are collected into the holes; after crossing the liquid-gas interface, they induce electroluminescence within the bubble. After having validated in previous works the LHM concept in liquid xenon, we provide here first preliminary results on its operation in liquid argon. We demonstrate the bubble containment under a Thick Gas Electron Multiplier (THGEM) electrode and provide detector response to alpha particles, recorded with a SiPM - under electroluminescence and with modest gas multiplication; the imaging capability is also demonstrated.
△ Less
Submitted 26 September, 2019; v1 submitted 14 August, 2019;
originally announced August 2019.
-
First results of Resistive-Plate Well (RPWELL) detector operation at 163 K
Authors:
A. Roy,
M. Morales,
I. Israelashvili,
A. Breskin,
S. Bressler,
D. Gonzalez-Diaz,
C. Pecharromán,
S. Shchemelinin,
D. Vartsky,
L. Arazi
Abstract:
We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comp…
▽ More
We present for the first time, discharge-free operation at cryogenic conditions of a Resistive-Plate WELL (RPWELL) detector. It is a single-sided Thick Gaseous Electron Multiplier (THGEM) coupled to a readout anode via a plate of high bulk resistivity. The results of single- and double-stage RPWELL detectors operated in stable conditions in Ne/5$\%$CH$_{4}$ at 163 K are summarized. The RPWELL comprised a ferric-based (Fe$^{3+}$) ceramic composite ("Fe-ceramic") as the resistive plate, of volume resistivity $\sim$$10^{11}$ $Ω$$\cdot$cm at this temperature. Gains of $\sim$$10^{4}$ and $\sim$$10^{5}$ were reached with the single-stage RPWELL, with 6 keV X-rays and single UV-photons, respectively. The double-stage detector, a THGEM followed by the RPWELL, reached gains $\sim$$10^{5}$ and $\sim$$10^{6}$ with X-rays and single UV-photons, respectively. The results were obtained with and without a CsI photocathode on the first multiplying element. Potential applications at these cryogenic conditions are discussed.
△ Less
Submitted 11 July, 2019;
originally announced July 2019.
-
Novel Resistive-Plate WELL sampling element for (S)DHCAL
Authors:
S. Bressler,
P. Bhattacharya,
A. Breskin,
A. E. C. Coimbra,
D. Shaked-Renous,
A. Tesi,
L. Moler,
M. Chefdeville,
G. Vouters,
J. Karyotakis,
C. Drancourt,
M. Titov,
T. Geralis
Abstract:
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage…
▽ More
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements could outperform. An attractive, industry-produced, robust, particle-tracking detector for large-area coverage, e.g. in (S)DHCAL, could be the novel single-stage Resistive Plate WELL (RPWELL). It is a single-sided THGEM coupled to the segmented readout electrode through a sheet of large bulk resistivity. We summarize here the preliminary test-beam results obtained with 6.5 mm thick (incl. electronics) {$48 \times 48\,\mathrm{cm^2}$}~RPWELL detectors. Two configurations are considered: a standalone RPWELL detector studied with 150 GeV muons and high-rate pions beams and RPWELL sampling element investigated within a small-(S)DHCAL prototype consisting of 7 resistive MICROMEGAS sampling elements followed by 5 RPWELL ones. The sampling elements were equipped with a Semi-Digital readout electronics based on the MICROROC chip.
△ Less
Submitted 26 September, 2019; v1 submitted 11 April, 2019;
originally announced April 2019.
-
First Imaging Results of a Bubble-assisted Liquid Hole Multiplier with SiPM readout in Liquid Xenon
Authors:
E. Erdal,
A. Tesi,
D. Vartsky,
S. Bressler,
L. Arazi,
A. Breskin
Abstract:
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, induci…
▽ More
First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into the holes of a Thick Gas Electron Multiplier (THGEM) electrode having a xenon gas bubble trapped underneath. They drift through the liquid-gas interface, inducing electroluminescence within the bubble. The resulting photons are detected with a Hamamatsu VUV4 quad-SiPM array - providing the deposited energy with a charge-only RMS resolution of 6.6%. The image reconstruction resolution was estimated to be ~200 um (RMS).
△ Less
Submitted 14 January, 2019; v1 submitted 29 November, 2018;
originally announced December 2018.
-
Signal Formation in THGEM-like Detectors
Authors:
Purba Bhattacharya,
Luca Moleri,
Shikma Bressler
Abstract:
Numerical simulations were used to study signal formation in a Thick Gaseous Electron Multiplier (THGEM) and in THGEM -based Thick-WELL (THWELL) and Resistive-Plate WELL (RPWELL) detectors. The signal shapes were simulated in mixtures of Argon and Neon with $5\%$ Methane under irradiation with soft x-rays and muons. Anode-induced raw signals were convoluted with the response functions of charge-se…
▽ More
Numerical simulations were used to study signal formation in a Thick Gaseous Electron Multiplier (THGEM) and in THGEM -based Thick-WELL (THWELL) and Resistive-Plate WELL (RPWELL) detectors. The signal shapes were simulated in mixtures of Argon and Neon with $5\%$ Methane under irradiation with soft x-rays and muons. Anode-induced raw signals were convoluted with the response functions of charge-sensitive and current-sensitive pre-amplifiers. The simulation toolkit was validated by the good agreement reached between the simulated and measured response, with different pre-amplifiers. It indicates that our simulations framework provides valid insight into the inherent complex dynamical processes of the various detectors.
△ Less
Submitted 10 March, 2025; v1 submitted 30 October, 2018;
originally announced October 2018.
-
Measurements of charging-up processes in THGEM-based particle detectors
Authors:
M. Pitt,
P. M. M. Correia,
S. Bressler,
A. E. C. Coimbra,
D. Shaked Renous,
C. D. R. Azevedo,
J. F. C. A. Veloso,
A. Breskin
Abstract:
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's envi…
▽ More
The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed to examine model-simulation results of the aforementioned phenomena, under various experimental conditions. The results indicate that in a stable detector's environment, the gain stabilization process is mainly affected by the charging-up of the detector's insulating surfaces caused by the avalanche charges. The charging-up is a transient effect, occurring during the detector's initial operation period; it does not affect its long-term operation. The experimental results are consistent with the outcome of model-simulations.
△ Less
Submitted 9 January, 2018; v1 submitted 1 January, 2018;
originally announced January 2018.
-
Simulation of gain stability of THGEM gas-avalanche particle detectors
Authors:
P. M. M. Correia,
M. Pitt,
C. D. R. Azevedo,
A. Breskin,
S. Bressler,
C. A. B. Oliveira,
A. L. M. Silva,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in rel…
▽ More
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Gain stabilization in Micro Pattern Gaseous Detectors: methodology and results
Authors:
Dan Shaked Renous,
Arindam Roy,
Amos Breskin,
Shikma Bressler
Abstract:
The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector init…
▽ More
The phenomenon of avalanche-gain variations over time, particularly in Micro Pattern Gaseous Detectors (MPGD) incorporating insulator materials, have been generally attributed to electric-field modifications resulting from "charging-up" effects of the insulator. A robust methodology for characterization of gain-transients in such detectors is presented. It comprises three guidelines: detector initialization, long-gain stabilization monitoring and imposing transients by applying abrupt changes in operation conditions. Using THWELL and RPWELL detectors, we validated the proposed methodology by assessing a charging-up/charging-down model describing the governing processes of gain stabilization. The results provide a deeper insight into these processes, reflected by different transients upon abrupt variations of detector gain or the irradiation rate. This methodology provides a handle for future investigations of the involved physics phenomena in MPGD detectors comprising insulating components.
△ Less
Submitted 17 July, 2017; v1 submitted 13 July, 2017;
originally announced July 2017.
-
On the localization properties of an RPWELL gas-avalanche detector
Authors:
Luca Moleri,
Purba Bhattacharya,
Artur E. C. Coimbra,
Amos Breskin,
Shikma Bressler
Abstract:
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV…
▽ More
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 10$^{10}$ $Ω\cdot$cm bulk resistivity. Operated in ambient Ne/(5$\%$CH$_4$) gas, the detector has been investigated with 150 GeV muons at CERN-SPS. Signals induced through the resistive plate on anode readout strips were recorded with APV25/SRS electronics. The experimental results are compared with that of Monte Carlo simulations. The effects of various physics phenomena on the position resolution are discussed. The measured position resolution in the present configuration is 0.28 mm RMS - compatible with the holes-pattern of the multiplier. Possible ways for improving the detector position resolution are suggested.
△ Less
Submitted 16 August, 2017; v1 submitted 1 July, 2017;
originally announced July 2017.
-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
First in-beam studies of a Resistive-Plate WELL gaseous multiplier
Authors:
S. Bressler,
L. Moleri,
M. Pitt,
S. Kudella,
D. C. R. Azevedo,
F. D. Amaro,
M. R. Jorge,
J. M. F. dos Santos,
J. F. C. A. Veloso,
H. Natal da Luz,
L. Arazi,
E. Olivieri,
A. Breskin
Abstract:
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar…
▽ More
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
△ Less
Submitted 20 January, 2016; v1 submitted 11 October, 2015;
originally announced October 2015.
-
Hadronic Calorimeter Shower Size: Challenges and Opportunities for Jet Substructure in the Superboosted Regime
Authors:
Shikma Bressler,
Thomas Flacke,
Yevgeny Kats,
Seung J. Lee,
Gilad Perez
Abstract:
Hadrons have finite interaction size with dense material, a basic feature common to known forms of hadronic calorimeters (HCAL). We argue that substructure variables cannot use HCAL information to access the microscopic nature of jets much narrower than the hadronic shower size, which we call superboosted massive jets. It implies that roughly 15% of their transverse energy profile remains inaccess…
▽ More
Hadrons have finite interaction size with dense material, a basic feature common to known forms of hadronic calorimeters (HCAL). We argue that substructure variables cannot use HCAL information to access the microscopic nature of jets much narrower than the hadronic shower size, which we call superboosted massive jets. It implies that roughly 15% of their transverse energy profile remains inaccessible due to the presence of long-lived neutral hadrons. This part of the jet substructure is also subject to order-one fluctuations. We demonstrate that the effects of the fluctuations are not reduced when a global correction to jet variables is applied. The above leads to fundamental limitations in the ability to extract intrinsic information from jets in the superboosted regime. The neutral fraction of a jet is correlated with its flavor. This leads to an interesting and possibly useful difference between superboosted W/Z/h/t jets and their corresponding backgrounds. The QCD jets that form the background to the signal superboosted jets might also be qualitatively different in their substructure as their mass might lie at or below the Sudakov mass peak. Finally, we introduce a set of zero-cone longitudinal jet substructure variables and show that while they carry information that might be useful in certain situations, they are not in general sensitive to the jet substructure.
△ Less
Submitted 15 March, 2016; v1 submitted 8 June, 2015;
originally announced June 2015.
-
A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures
Authors:
S. Bressler,
L. Moleri,
L. Arazi,
E. Erdal,
A. Rubin,
M. Pitt,
A. Breskin
Abstract:
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge…
▽ More
A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge probability. The methodology, applicable to a broad range of detectors, is applied here for instability studies in various single-stage THGEM and THGEM-WELL structures. The results indicate upon a somewhat larger attainable dynamic range in a single-stage THGEM operated with additional multiplication in the induction gap.
△ Less
Submitted 5 November, 2013; v1 submitted 2 November, 2013;
originally announced November 2013.
-
Laboratory studies of THGEM-based WELL structures with resistive anodes
Authors:
L. Arazi,
M. Pitt,
S. Bressler,
L. Moleri,
A. Rubin,
A. Breskin
Abstract:
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-qu…
▽ More
In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-quenching capability, gain variation with position and counting rate, pulse shapes and signal propagation to neighboring readout pads; the study included both 30x30 and 100x100 mm$^2$ detectors. It was shown that the WELL structures with resistive anodes offer stable operation even in a highly ionizing environment, with effective spark quenching, as well as higher gain than the standard THGEM/induction-gap configuration. Cross talk between neighboring readout pads was shown to be effectively eliminated in the segmented detector with a conductive grid underneath the resistive layer. The latter multiplier should allow for the design of very thin detectors, e.g. sampling elements in digital hadronic calorimeters planned for experiments in future linear colliders.
△ Less
Submitted 23 October, 2013;
originally announced October 2013.
-
Recent advances with THGEM detectors
Authors:
S. Bressler,
L. Arazi,
L. Moleri,
M. Pitt,
A. Rubin,
A. Breskin
Abstract:
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are singl…
▽ More
The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are single-sided THGEM electrodes directly coupled to different anode readout electrodes. The structures differ by the coupling concept of the bottom THGEM electrode to the metallic readout pads: a Thick WELL (THWELL) with direct coupling; the Resistive WELL (RWELL) and the Segmented Resistive WELL (SRWELL) coupled through thin resistive films deposited on insulating sheets and a Resistive-Plate WELL (RPWELL) coupled through a plate of high bulk resistivity. The results are compared to that of traditional double-sided THGEM electrodes followed by induction gaps - in some cases with moderate additional multiplication within the gap. We compare the different configurations in terms of gain, avalanche extension, discharge-rate and magnitude as well as rate capabilities over a broad dynamic range - exploiting a method that mimics highly ionizing particles in the laboratory. We report on recent studies of avalanche distribution in THGEM holes using optical readout.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.
-
First studies with the Resistive-Plate WELL gaseous multiplier
Authors:
A. Rubin,
L. Arazi,
S. Bressler,
L. Moleri,
M. Pitt,
A. Breskin
Abstract:
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV…
▽ More
We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization events. We present the RPWELL detector concept and compare its performance to that of other previously explored THGEM configurations--in terms of gain, its curves, dependence on rate, and the response to high ionization. The robust Resistive Plate WELL concept is a step forward in the Micro-Pattern Gas-Detector family, with numerous potential applications.
△ Less
Submitted 28 August, 2013;
originally announced August 2013.
-
Beam studies of novel THGEM-based potential sampling elements for Digital Hadron Calorimetry
Authors:
S. Bressler,
L. Arazi,
H. Natal da Luz,
C. D. A. Azevedo,
L. Moleri,
E. Oliveri,
M. Pitt,
A. Rubin,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin
Abstract:
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-mu…
▽ More
Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-multiplicity of ~1.1. The resistive anode resulted in efficient discharge damping, with few-volt potential drops; discharge probabilities were ~10^{-7} for muons and 10^{-6} for pions in the double-stage configuration, at rates of a few kHz/cm^2. These results, together with the robustness of THGEM electrodes against spark damage and their suitability for economic production over large areas make THGEM-based detectors highly competitive compared to the other technologies considered for the SiD-DHCAL.
△ Less
Submitted 25 July, 2013; v1 submitted 20 May, 2013;
originally announced May 2013.
-
Beam Studies of the Segmented Resistive WELL: a Potential Thin Sampling Element for Digital Hadron Calorimetry
Authors:
Lior Arazi,
Carlos Davide Rocha Azevedo,
Amos Breskin,
Shikma Bressler,
Luca Moleri,
Hugo Natal da Luz,
Eraldo Oliveri,
Michael Pitt,
Adam Rubin,
Joaquim Marques Ferreira dos Santos,
João Filipe Calapez Albuquerque Veloso,
Andrew Paul White
Abstract:
Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout p…
▽ More
Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout pads. Several 10$\times$10 cm$^2$ configurations with a total thickness of 5-6 mm (excluding electronics) with 1 cm$^2$ pads coupled to APV-SRS readout were investigated with muons and pions. Detection efficiencies in the 98$%$ range were recorded with average pad-multiplicity of $\sim$1.1. The resistive anode resulted in efficient discharge damping, with potential drops of a few volts; discharge probabilities were $\sim10^{-7}$ for muons and $\sim10^{-6}$ for pions in the double-stage configuration, at rates of a few kHz/cm$^2$. Further optimization work and research on larger detectors are underway.
△ Less
Submitted 7 May, 2013;
originally announced May 2013.
-
Optical readout: a tool for studying gas-avalanche processes
Authors:
A. Rubin,
L. Arazi,
S. Bressler,
A. Dery,
L. Moleri,
M. Pitt,
D. Vartsky,
A. Breskin
Abstract:
Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiate…
▽ More
Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiated with soft x-rays, of the hole-multiplicity and avalanche asymmetry within holes, as a function of detector parameters. Further study directions are discussed.
△ Less
Submitted 5 January, 2014; v1 submitted 6 May, 2013;
originally announced May 2013.
-
The Thin Gap Chambers database experience in test beam and preparations for ATLAS
Authors:
Y. Benhammou,
E. Etzion,
S. Bressler,
S. Tarem,
D. Lellouch,
L. Levinson
Abstract:
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last few years. A relational database was used for storing the conditions of t…
▽ More
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last few years. A relational database was used for storing the conditions of the tests as well as the configuration of the system. This database has provided the detector control system with the information needed for configuration of the front end electronics. The database is used to assist the online operation and maintenance. The same database is used to store the non event condition and configuration parameters needed later for the offline reconstruction software. A larger scale of the database has been produced to support the whole TGC system. It integrates all the production, QA tests and assembly information. A 1/12th model of the whole TGC system is currently in use for testing the performance of this database in configuring and tracking the condition of the system. A prototype of the database was first implemented during the H8 test beams. This paper describes the database structure, its interface to other systems and its operational performance.
△ Less
Submitted 26 September, 2005;
originally announced September 2005.
-
Separation of multiple evoked responses using differential amplitude and latency variability
Authors:
Kevin H. Knuth,
Wilson A. Truccolo,
Steven L. Bressler,
Mingzhou Ding
Abstract:
In neuroelectrophysiology one records electric potentials or magnetic fields generated by ensembles of synchronously active neurons in response to externally presented stimuli. These evoked responses are often produced by multiple generators in the presence of ongoing background activity. While source localization techniques or current source density estimation are usually used to identify gener…
▽ More
In neuroelectrophysiology one records electric potentials or magnetic fields generated by ensembles of synchronously active neurons in response to externally presented stimuli. These evoked responses are often produced by multiple generators in the presence of ongoing background activity. While source localization techniques or current source density estimation are usually used to identify generators, application of blind source separation techniques to obtain independent components has become more popular.
We approach this problem by applying the Bayesian methodology to a more physiologically-realistic source model. As it is generally accepted that single trials vary in amplitude and latency, we incorporate this variability into the model. Rather than making the unrealistic assumption that these cortical components are independent of one another, our algorithm utilizes the differential amplitude and latency variability of the evoked waveforms to identify the cortical components. The algorithm is applied to intracortically-recorded local field potentials in monkeys performing a visuomotor task.
△ Less
Submitted 29 April, 2002;
originally announced April 2002.