Spatial resolution improvements with finer-pitch GEMs
Authors:
K. J. Flöthner,
L. Scharenberg,
A. Brask,
F. Brunbauer,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
M. Van Stenis,
R. Veenhof
Abstract:
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In t…
▽ More
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
Reversed flow at low frequencies in a microfabricated AC electrokinetic pump
Authors:
Misha Marie Gregersen,
Laurits H. Olesen,
Anders Brask,
Mikkel Fougt Hansen,
Henrik Bruus
Abstract:
Microfluidic chips have been fabricated to study electrokinetic pumping generated by a low voltage AC signal applied to an asymmetric electrode array. A measurement procedure has been established and followed carefully resulting in a high degree of reproducibility of the measurements. Depending on the ionic concentration as well as the amplitude of the applied voltage, the observed direction of…
▽ More
Microfluidic chips have been fabricated to study electrokinetic pumping generated by a low voltage AC signal applied to an asymmetric electrode array. A measurement procedure has been established and followed carefully resulting in a high degree of reproducibility of the measurements. Depending on the ionic concentration as well as the amplitude of the applied voltage, the observed direction of the DC flow component is either forward or reverse. The impedance spectrum has been thoroughly measured and analyzed in terms of an equivalent circuit diagram. Our observations agree qualitatively, but not quantitatively, with theoretical models published in the literature.
△ Less
Submitted 10 April, 2007;
originally announced April 2007.