-
NEMA NU 2-2018 performance evaluation of a new generation digital 32-cm axial field-of-view Omni Legend PET-CT
Authors:
Rhodri Lyn Smith,
Lee Bartley,
Christopher O'Callaghan,
Kevin M. Bradley,
Chris Marshall
Abstract:
A NEMA performance evaluation was conducted on the new General Electric (GE) digital Omni Legend PET-CT system with 32-cm extended field-of-view. This study marks the introduction of the first-ever commercially available clinical digital bismuth germanate technology. Testing was performed in accordance with the NEMA NU2-2018 standard. A comparison was made with the performance of two other commerc…
▽ More
A NEMA performance evaluation was conducted on the new General Electric (GE) digital Omni Legend PET-CT system with 32-cm extended field-of-view. This study marks the introduction of the first-ever commercially available clinical digital bismuth germanate technology. Testing was performed in accordance with the NEMA NU2-2018 standard. A comparison was made with the performance of two other commercial GE scanners with extended fields-of-view. A digital lutetium yttrium orthosilicate system (Discovery MI - 6 ring) and a non-digital bismuth germanate system (Discovery IQ). For the Omni assessment, the tangential, radial, and axial spatial resolutions at 1 cm radial offset were measured as 3.76 mm, 3.73 mm, and 4.25 mm FWHM. The total system sensitivity to a line source at the center was 44.36 cps/kBq. The peak NECR was 501 kcps at 17.8 kBq/mL. The scatter fraction at NECR peak was 35.48%, and the maximum count-rate error at and below NEC peak was 5.5%. Sphere contrast recovery coefficients were from 52% (10 mm) to 93% (37 mm). The system does not use time of flight; thus, no assessment of timing resolution was made. The PET-CT co-registration accuracy was 2.4 mm. The performance of the Omni Legend surpassed that of the Discovery MI on all NEMA tests, except for assessments of background variability (image noise). Time of flight is associated with inherent improvements in signal-to-noise ratio. In lieu of time of flight capabilities, the Omni provides software corrections in the form of a pre-trained neural network (trained on non-ToF to ToF). With such corrections, average performance is competitive when compared to ToF systems. Further validation is required to optimize clinical imaging protocols and hyperparameters associated with such software corrections and to examine the effect of non-linear corrections with varying target size, particularly for real world, clinical scans.
△ Less
Submitted 11 August, 2023;
originally announced August 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
High-speed dual color fluorescence lifetime endomicroscopy for highly-multiplexed pulmonary diagnostic applications and detection of labeled bacteria
Authors:
Ettore Pedretti,
Michael G. Tanner,
Tushar R. Choudhary,
Nikola Krstajic,
Alicia Megia--Fernandez,
Robert K. Henderson,
Mark Bradley,
Robert R. Thomson,
John M. Girkin,
Kev Dhaliwal,
Paul A. Dalgarno
Abstract:
We present a dual color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche photo--diode detectors (SPADs), minimizing detection dead time maximizing th…
▽ More
We present a dual color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche photo--diode detectors (SPADs), minimizing detection dead time maximizing the number of photons detected per excitation pulse without photon pile--up to achieve the high frame rate. Dual color fluorescence imaging is achieved by temporally shifting the dual excitation lasers, with respect to each other, to separate the two spectrally distinct fluorescent decays. Combining the temporal encoding, to provide spectral separation, with lifetime measurements we show a one FPS, multi-channel endomicroscopy platform for clinical applications and diagnosis. We demonstrate the potential of the system by imaging smartprobe-labeled bacteria in ex vivo samples of human lung using lifetime to differentiate bacterial fluorescence from the strong background lung auto--fluorescence which was used to provide structural information.
△ Less
Submitted 4 September, 2018;
originally announced September 2018.
-
High fidelity fibre-based physiological sensing deep in tissue
Authors:
Tushar R. Choudhary,
Michael G. Tanner,
Alicia Megia-Fernandez,
Kerrianne Harrington,
Harry A. Wood,
Adam Marshall,
Patricia Zhu,
Sunay V. Chankeshwara,
Debaditya Choudhury,
Graham Monro,
Muhammed Ucuncu,
Fei Yu,
Rory R. Duncan,
Robert R. Thomson,
Kevin Dhaliwal,
Mark Bradley
Abstract:
Physiological sensing deep in tissue, remains a clinical challenge. Here a flexible miniaturised sensing optrode providing a platform to perform minimally invasive in vivo in situ measurements is reported. Silica microspheres covalently coupled with a high density of ratiometrically configured fluorophores were deposited into etched pits on the distal end of a 150 micron diameter multicore optical…
▽ More
Physiological sensing deep in tissue, remains a clinical challenge. Here a flexible miniaturised sensing optrode providing a platform to perform minimally invasive in vivo in situ measurements is reported. Silica microspheres covalently coupled with a high density of ratiometrically configured fluorophores were deposited into etched pits on the distal end of a 150 micron diameter multicore optical fibre. With this platform, multiplexed photonic measurements of pH and oxygen concentration with high precision in the distal alveolar space of the lung is reported. We demonstrated the phenomenon that high-density deposition of carboxyfluorescein covalently coupled to silica microspheres shows an inverse shift in fluorescence in response to varying pH. This platform delivered fast and accurate measurements, near instantaneous response time, no photobleaching, immunity to power fluctuations and a flexible architecture for addition of multiple sensors.
△ Less
Submitted 27 August, 2018;
originally announced August 2018.
-
Fast Switching Dual Fabry-Perot Cavity Optical Refractometry - Methodologies for Accurate Assessment of Gas Density
Authors:
Isak Silander,
Thomas Hausmaninger,
Michael Bradley,
Martin Zelan,
Ove Axner
Abstract:
Dual Fabry-Perot cavity based optical refractometry (DFPC-OR) has a high potential for assessments of gas density. However, drifts of the FP cavity often limit its performance. We show that by the use of two narrow-linewidth fiber lasers locked to two high finesse cavities and Allan-Werle plots that drift-free DFPC-OR can be obtained for short measurement times (for which the drifts of the cavity…
▽ More
Dual Fabry-Perot cavity based optical refractometry (DFPC-OR) has a high potential for assessments of gas density. However, drifts of the FP cavity often limit its performance. We show that by the use of two narrow-linewidth fiber lasers locked to two high finesse cavities and Allan-Werle plots that drift-free DFPC-OR can be obtained for short measurement times (for which the drifts of the cavity can be disregarded). Based on this, a novel strategy, termed fast switching DFPC-OR (FS-DFPC-OR), is presented. A set of novel methodologies for assessment of both gas density and flow rates (in particular from small leaks) that are not restricted by the conventional limitations imposed by the drifts of the cavity are presented. The methodologies deal with assessments in both open and closed (finite-sized) compartments. They circumvent the problem with volumetric expansion, i.e. that the gas density in a measurement cavity is not the same as that in the closed external compartment that should be assessed, by performing a pair of measurements in rapid succession; the first one serves the purpose of assessing the density of the gas that has been transferred into the measurement cavity by the gas equilibration process, while the 2nd is used to automatically calibrate the system with respect to the relative volumes of the measurement cavity and the external compartment. The methodologies for assessments of leak rates comprise triple cavity evacuation assessments, comprising two measurements performed in rapid succession, supplemented by a 3rd measurement a certain time thereafter. A clear explanation of why the technique has such a small temperature dependence is given. It is concluded that FS-DFPC-OR constitutes a novel strategy that can be used for precise and accurate assessment of gas number density and gas flows under a variety of conditions, in particular non-temperature stabilized ones.
△ Less
Submitted 10 January, 2018; v1 submitted 3 April, 2017;
originally announced April 2017.
-
Ballistic and snake photon imaging for locating optical endomicroscopy fibres
Authors:
M. G. Tanner,
T. R. Choudhary,
T. H. Craven,
B. Mills,
M. Bradley,
R. K. Henderson,
K. Dhaliwal,
R. R. Thomson
Abstract:
We demonstrate determination of the location of the distal-end of a fibre-optic device deep in tissue through the imaging of ballistic and snake photons using a time resolved single-photon detector array. The fibre was imaged with centimetre resolution, within clinically relevant settings and models. This technique can overcome the limitations imposed by tissue scattering in optically determining…
▽ More
We demonstrate determination of the location of the distal-end of a fibre-optic device deep in tissue through the imaging of ballistic and snake photons using a time resolved single-photon detector array. The fibre was imaged with centimetre resolution, within clinically relevant settings and models. This technique can overcome the limitations imposed by tissue scattering in optically determining the in vivo location of fibre-optic medical instruments.
△ Less
Submitted 18 August, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
Exact nonstationary solutions to the mean-field equations of motion for two-component Bose-Einstein condensates in periodic potentials
Authors:
R. Mark Bradley,
Bernard Deconinck,
J. Nathan Kutz
Abstract:
We study the dynamics of two-component Bose-Einstein condensates in periodic potentials in one dimension. Elliptic potentials which have the sinusoidal optical potential as a special case are considered. We construct exact nonstationary solutions to the mean-field equations of motion. Among the solutions are two types of temporally-periodic solutions -- in one type there are condensate oscillati…
▽ More
We study the dynamics of two-component Bose-Einstein condensates in periodic potentials in one dimension. Elliptic potentials which have the sinusoidal optical potential as a special case are considered. We construct exact nonstationary solutions to the mean-field equations of motion. Among the solutions are two types of temporally-periodic solutions -- in one type there are condensate oscillations between neighboring potential wells, while in the other the condensates oscillate from side to side within the wells. Our numerical studies of the stability of these solutions suggests the existence of one-parameter families of stable nonstationary solutions.
△ Less
Submitted 21 March, 2004;
originally announced March 2004.
-
Parametric Excitation of Alfven Waves by Gravitational Radiation
Authors:
M. Servin,
G. Brodin,
M. Bradley,
M. Marklund
Abstract:
We consider the parametric excitation of Alfven waves by gravitational radiation propagating on a Minkowski background, parallel to an external magnetic field. As a starting point, standard ideal MHD equations incorporating the curvature of space-time has been derived. The growth rate of the Alfven waves has been calculated, using the normal mode approach. Various astrophysical applications of o…
▽ More
We consider the parametric excitation of Alfven waves by gravitational radiation propagating on a Minkowski background, parallel to an external magnetic field. As a starting point, standard ideal MHD equations incorporating the curvature of space-time has been derived. The growth rate of the Alfven waves has been calculated, using the normal mode approach. Various astrophysical applications of our investigations are discussed, and finally we demonstrate that the coupling coefficients of the interacting modes fulfill the Manley-Rowe relations.
△ Less
Submitted 7 September, 2000; v1 submitted 19 October, 1999;
originally announced October 1999.