The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance
Authors:
N. Abgrall,
E. Aguayo,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Boswell,
A. W. Bradley,
V. Brudanin,
T. H. Burritt,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
D. C. Combs,
C. Cuesta
, et al. (86 additional authors not shown)
Abstract:
Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations.…
▽ More
Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $ββ(0ν)$ search. This enabled it to achieve an ultimate half-life limit on $ββ(0ν)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.
△ Less
Submitted 3 January, 2025;
originally announced January 2025.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator
Authors:
M. Busch,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Design improvements to cables and connectors in the Majorana Demonstrator
Authors:
C. R. Haufe,
A. L. Reine,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (46 additional authors not shown)
Abstract:
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Researc…
▽ More
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.
△ Less
Submitted 9 December, 2017;
originally announced December 2017.
-
Initial Results from the Majorana Demonstrator
Authors:
T. S. Caldwell,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (47 additional authors not shown)
Abstract:
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point con…
▽ More
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the full detector array has been acquiring data since August 2016. We will discuss the status of the MAJORANA DEMONSTRATOR and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the DEMONSTRATOR, and implications for a ton-scale Ge-based neutrinoless double-beta decay search.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Data quality assurance for the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility i…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. The various techniques employed to ensure the integrity of the measured spectra are discussed. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components
Authors:
C. D. Christofferson,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operatin…
▽ More
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Progress Toward A $2νββ$ Measurement For The Majorana Demonstrator
Authors:
T Gilliss,
N Abgrall,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
A W Bradley,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (…
▽ More
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode ($2νββ$) of $^{76}$Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the $0νββ$ mode, even for a ton-scale experiment. However, the measurement of the $2νββ$ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the $0νββ$ and $2νββ$ decay modes. A precision measurement of the $2νββ$ shape also allows searches for spectral distortions, possibly indicative of new physics, including $0νββχ$. Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise $2νββ$ spectrum and half-life.
△ Less
Submitted 20 November, 2017; v1 submitted 15 November, 2017;
originally announced November 2017.
-
Spectral analysis for the Majorana Demonstrator experiment
Authors:
L. Hehn,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanf…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data taken with this setup since summer 2015 at different construction stages of the experiment show a clear reduction of the observed background index around the ROI for $0νββ$-decay search due to improvements in shielding. We discuss the statistical approaches to search for a $0νββ$-signal and derive the physics sensitivity for an expected exposure of $10\,\textrm{kg}{\cdot}\textrm{y}$ from enriched detectors using a profile likelihood based hypothesis test in combination with toy Monte Carlo data.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
Authors:
C. E. Aalseth,
N. Abgrall,
E. Aguayo,
S. I. Alvis,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
M. Boswell,
R. L. Brodzinski,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson
, et al. (104 additional authors not shown)
Abstract:
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construct…
▽ More
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr (90\% CL). This result constrains the effective Majorana neutrino mass to below 240 to 520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$ counts/(FWHM t yr).
△ Less
Submitted 26 March, 2018; v1 submitted 31 October, 2017;
originally announced October 2017.
-
The Status and Initial Results of the MAJORANA DEMONSTRATOR Experiment
Authors:
V. E. Guiseppe,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (45 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge de…
▽ More
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the DEMONSTRATOR are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. We discuss results of the initial physics runs, as well as the status and physics reach of the full MAJORANA DEMONSTRATOR experiment.
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
The Processing of Enriched Germanium for the MAJORANA DEMONSTRATOR and R&D for a Possible Future Ton-Scale Ge-76 Double-Beta Decay Experiment
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
J. Caja,
M. Caja,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
D. T. Dunstan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure…
▽ More
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure to cosmic rays. These procedures include careful accounting for the material; shielding it to reduce cosmogenic generation of radioactive isotopes; and development of special reprocessing techniques for contaminated solid germanium, shavings, grindings, acid etchant and cutting fluids from detector fabrication. Processing procedures were developed that resulted in a total yield in detector mass of 70%. However, none of the acid-etch solution and only 50% of the cutting fluids from detector fabrication were reprocessed. Had they been processed, the projections for the recovery yield would be between 80 -- 85%. Maximizing yield is critical to justify a possible future ton-scale experiment. A process for recovery of germanium from the acid-etch solution was developed with yield of about 90%. All material was shielded or stored underground whenever possible to minimize the formation of Ge-68 by cosmic rays, which contributes background in the double-beta decay region of interest and cannot be removed by zone refinement and crystal growth. Formation of Ge-68 was reduced by a significant factor over that in natural abundance detectors not protected from cosmic rays.
△ Less
Submitted 19 July, 2017;
originally announced July 2017.
-
The Majorana Demonstrator calibration system
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
V. M. Gehman,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioact…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this paper, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
New limits on Bosonic Dark Matter, Solar Axions, Pauli Exclusion Principle Violation, and Electron Decay from the Majorana Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn
, et al. (42 additional authors not shown)
Abstract:
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8…
▽ More
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8 keV mass particles, limiting $g_{Ae} <4.5\times 10^{-13}$ for pseudoscalars and $\frac{α'}α < 9.7\times 10^{-28}$ for vectors. We also report a 14.4 keV solar axion coupling limit of $g_{AN}^{\mathrm{eff}}\times g_{Ae}~<~3.8 \times 10^{-17}$, a $\frac{1}{2}β^2~<~8.5\times10^{-48}$ limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of $τ_e > 1.2 \times 10^{24}\;$yr for $e^- \rightarrow$ invisible.
△ Less
Submitted 11 April, 2017; v1 submitted 2 December, 2016;
originally announced December 2016.
-
Search for Pauli Exclusion Principle Violating Atomic Transitions and Electron Decay with a P-type Point Contact Germanium Detector
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. S Finnerty,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (44 additional authors not shown)
Abstract:
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electr…
▽ More
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8x10^30 seconds at 90 C.L. It is estimated that the MAJORANA DEMONSTRATOR, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76-Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.
△ Less
Submitted 19 October, 2016;
originally announced October 2016.
-
Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors
Authors:
J. Gruszko,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular…
▽ More
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular detector arrays is posed by alpha particles. In the Majorana Demonstrator, events have been observed that are consistent with energy- degraded alphas originating on the passivated surface, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, charges drift through the bulk onto that surface, and then drift along it with greatly reduced mobility. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. In this contribution we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery, allowing for the efficient rejection of passivated surface alpha events in analysis.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Initial Results from the MAJORANA DEMONSTRATOR
Authors:
S. R. Elliott,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge)…
▽ More
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full {\sc Majorana Demonstrator} experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Background model for the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4…
▽ More
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4 keV region of interest (ROI) around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials and analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements. Preliminary background results obtained during the engineering runs of the Demonstrator are presented.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
The Majorana Demonstrator search for neutrinoless double beta decay
Authors:
C. Cuesta,
M. Buuck,
J. A. Detwiler,
J. Gruszko,
I. S. Guinn,
J. Leon,
R. G. H. Robertson,
N. Abgrall,
A. W. Bradley,
Y-D. Chan,
S. Mertens,
A. W. P. Poon,
K. Vetter,
I. J. Arnquist,
E. W. Hoppe,
R. T. Kouzes,
J. L. Orrell,
F. T. Avignone III,
A. S. Barabash,
S. I. Konovalov,
V. Yumatov,
F. E. Bertrand,
A. Galindo-Uribarri,
D. C. Radford,
R. L. Varner
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.
△ Less
Submitted 29 August, 2016; v1 submitted 25 August, 2016;
originally announced August 2016.
-
High voltage testing for the MAJORANA Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett
, et al. (48 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector sign…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.
△ Less
Submitted 28 March, 2016; v1 submitted 28 March, 2016;
originally announced March 2016.
-
Muon Flux Measurements at the Davis Campus of the Sanford Underground Research Facility with the Majorana Demonstrator Veto System
Authors:
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (49 additional authors not shown)
Abstract:
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
△ Less
Submitted 7 September, 2016; v1 submitted 24 February, 2016;
originally announced February 2016.
-
The Majorana Demonstrator Radioassay Program
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
J. A. Dunmore,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. Finnerty,
A. Galindo-Uribarri,
V. M. Gehman
, et al. (60 additional authors not shown)
Abstract:
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires tha…
▽ More
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements of the radioactive-isotope contamination for a number of materials studied for use in the detector are reported.
△ Less
Submitted 22 April, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Status of the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMON…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First, the prototype module was assembled; it has been continuously taking data from July 2014 to June 2015. Second, Module 1 with more than half of the total enriched detectors and some natural detectors has been assembled and it is being commissioned. Finally, the assembly of Module 2, which will complete MAJORANA DEMONSTRATOR, is already in progress.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR
Authors:
I. Guinn,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of…
▽ More
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of <3 counts/ROI-tonne-year, which is expected to scale down to <1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.
△ Less
Submitted 13 June, 2015;
originally announced June 2015.
-
Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path f…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR 0s germanium detectors allows for significant reduction of gamma background.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.