-
A prototype reactor-antineutrino detector based on $^6$Li-doped pulse-shaping-discriminating plastic scintillator
Authors:
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. Bravo,
R. Carr,
T. M. Classen,
A. J. Conant,
S. A. Dazeley,
M. T. Dunbrack,
S. R. Durham,
A. S. Erickson,
A. Haghighat,
K. M. Heeger,
P. Huber,
A. Irani,
O. Kyzylova,
V. A. Li,
J. M. Link,
B. R. Littlejohn,
F. Machado,
M. P. Mendenhall,
H. P. Mumm,
J. Newby,
C. Roca,
J. Ross
, et al. (4 additional authors not shown)
Abstract:
An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of 5.5~cm. Doped with $^{6}$Li at 0.1\% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the…
▽ More
An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of 5.5~cm. Doped with $^{6}$Li at 0.1\% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-beta-decay reaction. Each bar is wrapped with a specular reflector that directs photons towards PMTs mounted at both ends of the bar. This paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as PSD, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.
△ Less
Submitted 8 May, 2025;
originally announced May 2025.
-
Nuclear recoil detection with color centers in bulk lithium fluoride
Authors:
Gabriela A. Araujo,
Laura Baudis,
Nathaniel Bowden,
Jordan Chapman,
Anna Erickson,
Mariano Guerrero Perez,
Adam A. Hecht,
Samuel C. Hedges,
Patrick Huber,
Vsevolod Ivanov,
Igor Jovanovic,
Giti A. Khodaparast,
Brenden A. Magill,
Jose Maria Mateos,
Maverick Morrison,
Nicholas W. G. Smith,
Patrick Stengel,
Stuti Surani,
Nikita Vladimirov,
Keegan Walkup,
Christian Wittweg,
Xianyi Zhang
Abstract:
We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast a…
▽ More
We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast and thermal neutron interactions deep inside a cubic-centimeter sized crystal and demonstrate automated feature extraction in three dimensions using machine learning tools. The number, size, and topology of the events agree with expectations based on simulations with TRIM. These results constitute the first step towards 10-1000g scale detectors with single-event sensitivity for applications such as the detection of dark matter particles, reactor neutrinos, and neutrons.
△ Less
Submitted 26 March, 2025;
originally announced March 2025.
-
CONFLUX: A Standardized Framework to Calculate Reactor Antineutrino Flux
Authors:
Xianyi Zhang,
Anosh Irani,
Michael P. Mendenhall,
Nathan Rybicki,
Leendert Hayen,
Nathaniel Bowden,
Patrick Huber,
Bryce Littlejohn,
Sandra Bogetic
Abstract:
Nuclear fission reactors are abundant sources of antineutrinos. The flux and spectrum of antineutrinos emitted by a reactor can indicate its activity and composition, suggesting potential applications of neutrino measurements beyond fundamental scientific studies that may be valuable to society. The utility of reactor antineutrinos for applications and fundamental science is dependent on the avail…
▽ More
Nuclear fission reactors are abundant sources of antineutrinos. The flux and spectrum of antineutrinos emitted by a reactor can indicate its activity and composition, suggesting potential applications of neutrino measurements beyond fundamental scientific studies that may be valuable to society. The utility of reactor antineutrinos for applications and fundamental science is dependent on the availability of precise predictions of these emissions. For example, in the last decade, disagreements between reactor antineutrino measurements and models have inspired revision of reactor antineutrino calculations and standard nuclear databases as well as searches for new fundamental particles not predicted by the Standard Model of particle physics. Past predictions and descriptions of the methods used to generate them are documented to varying degrees in the literature, with different modeling teams incorporating a range of methods, input data, and assumptions. The resulting difficulty in accessing or reproducing past models and reconciling results from differing approaches complicates the future study and application of reactor antineutrinos. The CONFLUX (Calculation Of Neutrino FLUX) software framework is a neutrino prediction tool built with the goal of simplifying, standardizing, and democratizing the process of reactor antineutrino flux calculations. CONFLUX include three primary methods for calculating the antineutrino emissions of nuclear reactors or individual beta decays that incorporate common nuclear data and beta decay theory. The software is prepackaged with the current nuclear database. It includes the capability to predict time-dependent neutrino model, adjust decay information entries, and propagate uncertainties. This paper describes the software structure, details the methods used for flux and spectrum calculations, and talks about potential use cases.
△ Less
Submitted 20 March, 2025;
originally announced March 2025.
-
Machine Learning for Single-Ended Event Reconstruction in PROSPECT Experiment
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. J. Dolinski,
A. Erickson,
M. Fuller,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
T. E. Haugen,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar
, et al. (21 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and partic…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
Reactor Antineutrino Directionality Measurement with the PROSPECT-I Detector
Authors:
M. Andriamirado,
B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
M. J. Dolinski,
A. Erickson,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar,
D. C. Jones,
J. R. Koblanski,
P. Kunkle
, et al. (24 additional authors not shown)
Abstract:
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and…
▽ More
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and $θ= 98.6\unicode{xB0} \pm 0.4\unicode{xB0}$, the PROSPECT-I detector is able to reconstruct an average neutrino direction of $φ= 39.4\unicode{xB0} \pm 2.9\unicode{xB0}$ and $θ= 97.6\unicode{xB0} \pm 1.6\unicode{xB0}$. This measurement is made with approximately 48000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.
△ Less
Submitted 11 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Performance of large-scale 6Li-doped pulse-shape discriminating plastic scintillators
Authors:
C. Roca,
N. S. Bowden,
L. Carman,
S. A. Dazeley,
S. R. Durham,
O. M. Falana,
M. J. Ford,
A. M. Glenn,
C. Hurlbut,
V. A. Li,
M. P. Mendenhall,
K. Shipp,
F. Sutanto,
N. P. Zaitseva
Abstract:
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable…
▽ More
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to $^6$Li-doped liquid scintillators. The scintillator EJ-299-50 shows good neutron detection capabilities with an effective efficiency for capture on $^6$Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
$^6$Li-loaded liquid scintillators produced by direct dissolution of compounds in diisopropylnaphthalene (DIPN)
Authors:
N. P. Zaitseva,
M. L. Carman,
M. J. Ford,
A. M. Glenn,
C. Roca,
S. Durham,
F. Sutanto,
S. A. Dazeley,
N. S. Bowden
Abstract:
The paper describes preparation of $^6$Li-loaded liquid scintillators by methods involving direct dissolution of $^6$Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of $^6$Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (H…
▽ More
The paper describes preparation of $^6$Li-loaded liquid scintillators by methods involving direct dissolution of $^6$Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of $^6$Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic and aliphatic $^6$Li salts in DIPN can be easily achieved at 0.1- 0.3% by weight of atomic $^6$Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of $^6$Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient $^6$Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.
△ Less
Submitted 13 June, 2024; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale
Authors:
Michael J. Ford,
Elisabeth Aigeldinger,
Felicia Sutanto,
Natalia P. Zaitseva,
Viacheslav A. Li,
M. Leslie Carman,
Andrew Glenn,
Cristian R. Catala,
Steven A. Dazeley,
Nathaniel Bowden
Abstract:
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs were necessitated by the inclusion of 0.1 wt. % lithium-6 to enable detection of thermal neutrons. The synthesis and processing of these plastic scintillators o…
▽ More
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs were necessitated by the inclusion of 0.1 wt. % lithium-6 to enable detection of thermal neutrons. The synthesis and processing of these plastic scintillators on the kilogram scale required consideration of many factors. First, a comonomer (methacrylic acid) was used to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, scintillation performance and processability were considered because the increasing content of the comonomer resulted in a sharp decrease in the light output. The use of small amounts of comonomer (less than or equal to 3 wt. %) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate an exothermic polymerization that results in premature curing and/or defects. The deleterious effects of the comonomer may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discoloration while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.
△ Less
Submitted 10 January, 2023;
originally announced January 2023.
-
Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (36 additional authors not shown)
Abstract:
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se…
▽ More
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
△ Less
Submitted 10 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Report of the Topical Group on Neutrino Applications for Snowmass 2021
Authors:
N. S. Bowden,
J. M. Link,
W. Wang
Abstract:
This report has been prepared as part of the US Community Study on the Future of Particle Physics (Snowmass 2021) by the Snowmass Neutrino Frontier Topical Group NF07 Conveners, based on input from contributed White papers and Letters of Interest.
This report has been prepared as part of the US Community Study on the Future of Particle Physics (Snowmass 2021) by the Snowmass Neutrino Frontier Topical Group NF07 Conveners, based on input from contributed White papers and Letters of Interest.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors
Authors:
Ethan P. Bernard,
Eli Mizrachi,
James Kingston,
Jingke Xu,
Sergey V. Pereverzev,
Teal Pershing,
Ryan Smith,
Charles G. Prior,
Nathaniel S. Bowden,
Adam Bernstein,
Carter R. Hall,
Emilija Pantic,
Mani Tripathi,
Daniel N. McKinsey,
Phillip S. Barbeau
Abstract:
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or…
▽ More
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Future Advances in Photon-Based Neutrino Detectors: A SNOWMASS White Paper
Authors:
Joshua R. Klein,
Tomi Akindele,
Adam Bernstein,
Steven Biller,
Nathaniel Bowden,
Jason Brodsky,
D. F. Cowen,
Michael Ford,
Julieta Gruszko,
Logan Lebenowski,
Aobo Li,
Viacheslav A. Li,
Wei Mu,
J. Pedro Ochoa-Ricoux,
Gabriel D. Orebi Gann,
Mayly Sanchez,
Robert Svoboda,
Matthew Wetstein,
Michael Wurm,
Minfang Yeh
Abstract:
We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physic…
▽ More
We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physics programs in hybrid Cherenkov/scintillation detectors, such as slow fluors, water-based liquid scintillator, and spectral sorting of photons. Several new large-scale detector ideas are also discussed, including hybrid detectors like Theia, ArTEMIS, and generic slow-fluor detectors, as well as the very different SLIPs and LiquidO approaches to instrumenting photon-based detectors. A program of demonstrators for future detectors, including ANNIE, Eos, and NuDOT are also discussed.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
White Paper on Light Sterile Neutrino Searches and Related Phenomenology
Authors:
M. A. Acero,
C. A. Argüelles,
M. Hostert,
D. Kalra,
G. Karagiorgi,
K. J. Kelly,
B. Littlejohn,
P. Machado,
W. Pettus,
M. Toups,
M. Ross-Lonergan,
A. Sousa,
P. T. Surukuchi,
Y. Y. Y. Wong,
W. Abdallah,
A. M. Abdullahi,
R. Akutsu,
L. Alvarez-Ruso,
D. S. M. Alves,
A. Aurisano,
A. B. Balantekin,
J. M. Berryman,
T. Bertólez-Martínez,
J. Brunner,
M. Blennow
, et al. (147 additional authors not shown)
Abstract:
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference,…
▽ More
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.
△ Less
Submitted 29 October, 2024; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements: Summary Report of the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM)
Authors:
Catherine Romano,
Nathaniel Bowden,
Andrew Conant,
Bethany Goldblum,
Patrick Huber,
Jonathan Link,
Bryce Littlejohn,
Pieter Mumm,
Juan Pedro Ochoa-Ricoux,
Shikha Prasad,
Catherine Riddle,
Alejandro Sonzogni,
William Wieselquist
Abstract:
The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coheren…
▽ More
The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three.
To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
PROSPECT-II Physics Opportunities
Authors:
M. Andriamirado,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribari,
C. E. Gilbert,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (37 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum fr…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from $^{235}$U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the Reactor Antineutrino Anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world's most precise measurement of the $^{235}$U antineutrino spectrum and measuring the absolute flux of antineutrinos from $^{235}$U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.
△ Less
Submitted 3 September, 2022; v1 submitted 8 July, 2021;
originally announced July 2021.
-
Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target
Authors:
M. Monterial,
K. T. Schmitt,
C. Prokop,
E. Leal-Cidoncha,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta
, et al. (15 additional authors not shown)
Abstract:
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio betwee…
▽ More
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.
△ Less
Submitted 9 July, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
Measurement of Muon-induced High-energy Neutrons from Rock in an Underground Gd-doped Water Detector
Authors:
F. Sutanto,
O. A. Akindele,
M. Askins,
M. Bergevin,
A. Bernstein,
N. S. Bowden,
S. Dazeley,
P. Jaffke,
I. Jovanovic,
S. Quillin,
C. Roecker,
S. D. Rountree
Abstract:
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results w…
▽ More
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results with the expected rate of correlated neutron captures arising from high-energy neutrons incident on the outside of the WATCHBOY shield, predicted by a hybrid FLUKA/GEANT4-based simulation. The incident neutron energy distribution used in the simulation was measured by a fast neutron spectrometer, the 1.8-ton Multiplicity and Recoil Spectrometer (MARS) detector, at the same depth. We find that the measured detection rate of two correlated neutrons is consistent with that predicted by simulation. The result lends additional confidence in the detection technique used by MARS, and therefore in the MARS spectra as measured at three different depths. Confirmation of the fast neutron flux and spectrum is important as it helps validate the scaling models used to predict the fast neutron fluxes at different overburdens.
△ Less
Submitted 30 August, 2020;
originally announced August 2020.
-
Applied Antineutrino Physics 2018 Proceedings
Authors:
M. Bergevin,
N. Bowden,
H. P. Mumm,
M. Verstraeten,
J. Park,
B. Han,
Y. Shitov,
A. P. Serebrov,
A. Onillon,
G. Karagiorgi,
K. Nakajima,
P. Chimenti,
J. Coleman,
M. Askins,
L. Marti-Magro,
T. Hill,
R. Carr,
J. Johnston,
A. N. Mabe,
M. Yeh,
G. D. Orebi Gann,
M. P. Mendenhall,
D. Mulmule,
D. L. Danielson,
J. G. Learned
Abstract:
Proceedings for the 14th installment of Applied Antineutrino Physics (AAP) workshop series.
Proceedings for the 14th installment of Applied Antineutrino Physics (AAP) workshop series.
△ Less
Submitted 9 December, 2019; v1 submitted 15 November, 2019;
originally announced November 2019.
-
Neutrino Detectors as Tools for Nuclear Security
Authors:
Adam Bernstein,
Nathaniel Bowden,
Bethany L. Goldblum,
Patrick Huber,
Igor Jovanovic,
John Mattingly
Abstract:
For over 40 years, physicists have considered possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This colloquium presents a b…
▽ More
For over 40 years, physicists have considered possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This colloquium presents a broad overview of several potential neutrino applications, including the near-field monitoring of known reactors, far-field monitoring of known or discovery of undeclared reactors, detection of reactor waste streams, and detection of nuclear explosions. We conclude that recent detector advances have made near-field monitoring feasible. Farther-field reactor detection and waste stream detection monitoring are possible in some cases with further research and development. Very long-range reactor monitoring and nuclear explosion detection do not appear feasible for the foreseeable future due to considerable physical and/or practical constraints.
△ Less
Submitted 25 March, 2020; v1 submitted 19 August, 2019;
originally announced August 2019.
-
The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
M. Febbraro,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
B. T. Hackett,
S. Hans
, et al. (40 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at…
▽ More
The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.
△ Less
Submitted 16 August, 2019; v1 submitted 17 June, 2019;
originally announced June 2019.
-
1H(n,el) as a Cross Section Reference in a White Source Neutron Beam With the fissionTPC
Authors:
N. I. Walsh,
J. T. Barker,
N. S. Bowden,
K. J. Brewster,
R. J. Casperson,
T. Classen,
N. Fotiadis,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
D. Hensle,
C. R. Hicks,
D. Higgins,
L. D. Isenhower,
A. Kemnitz,
K. J. Kiesling,
J. King,
J. L. Klay,
J. Latta,
W. Loveland,
J. A. Magee,
M. P. Mendenhall,
M. Monterial,
S. Mosby
, et al. (11 additional authors not shown)
Abstract:
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such…
▽ More
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such as the H(n,el) cross section there is the potential to further reduce the evaluation uncertainties of the measured cross sections. In principle the fissionTPC could provide a unique measurement by simultaneously measuring both fission fragments and proton recoils over a large solid angle. We investigate one method with a hydrogenous gas target and with the neutron energy determined by the proton recoil kinematics. This method enables the measurement to be performed in a white-source neutron beam and with the current configuration of the fissionTPC. We show that while such a measurement is feasible in the energy range of 0.5 MeV to $\sim$10 MeV, uncertainties on the proton detection efficiency and the neutron energy resolution do not allow us to preform a fission ratio measurement to the desired precision. Utilizing either a direct measurement of the neutron time-of-flight for the recoil proton or a mono-energetic neutron source or some combination of both would provide a path to a sub-percent precision measurement.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
A Low Mass Optical Grid for the PROSPECT Reactor Antineutrino Detector
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
A. E. Detweiler M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
Y. Gebre,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of…
▽ More
PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a short-baseline reactor antineutrino experiment designed to provide precision measurements of the $^{235}$U product $\overlineν_e$ spectrum of utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT's segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overlineν_e$ interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis, and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.
△ Less
Submitted 9 April, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Lithium-loaded Liquid Scintillator Production for the PROSPECT experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
C. Camilo Reyes,
S. Campos,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
D. Davee,
D. Dean,
G. Deichert,
R. Diaz Perez,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust
, et al. (45 additional authors not shown)
Abstract:
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a…
▽ More
This work reports the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). Fifty-nine 90 liter batches of LiLS (${}^6{\rm Li}$ mass fraction 0.082%$\pm$0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.
△ Less
Submitted 27 March, 2019; v1 submitted 16 January, 2019;
originally announced January 2019.
-
Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
T. Classen,
A. J. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
M. Febbraro,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert
, et al. (45 additional authors not shown)
Abstract:
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays…
▽ More
This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.
△ Less
Submitted 28 June, 2019; v1 submitted 27 December, 2018;
originally announced December 2018.
-
The PROSPECT Reactor Antineutrino Experiment
Authors:
PROSPECT Collaboration,
J. Ashenfelter,
A. B. Balantekin,
C. Baldenegro,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
L. J. Bignell,
N. S. Bowden,
J. Boyle,
J. Bricco,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
A. A. Cox,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski
, et al. (64 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reacto…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented $^6$Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the $\barν_e$ disappearance experiments at 4$σ$ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3$σ$ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.
△ Less
Submitted 21 August, 2019; v1 submitted 31 July, 2018;
originally announced August 2018.
-
Performance of a segmented $^{6}$Li-loaded liquid scintillator detector for the PROSPECT experiment
Authors:
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
C. D. Bass,
D. E. Bergeron,
D. Berish,
N. S. Bowden,
J. P. Brodsky,
C. D. Bryan,
A. Bykadorova Telles,
J. J. Cherwinka,
T. Classen,
K. Commeford,
A. Conant,
D. Davee,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
B. Hackett,
K. Han
, et al. (41 additional authors not shown)
Abstract:
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source a…
▽ More
This paper describes the design and performance of a 50 liter, two-segment $^{6}$Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the $^{6}$Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850$\pm$20 PE/MeV, an energy resolution of $σ$ = 4.0$\pm$0.2% at 1 MeV, and efficient pulse-shape discrimination of low $dE/dx$ (electronic recoil) and high $dE/dx$ (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85$\pm$3 cm is measured in each segment. The 0.1% by mass concentration of $^{6}$Li in the scintillator results in a measured neutron capture time of $τ$ = 42.8$\pm$0.2 $μs$. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.
△ Less
Submitted 29 June, 2018; v1 submitted 23 May, 2018;
originally announced May 2018.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a MICROMEGAS-based TPC in a high-energy neutron beam
Authors:
Lucas Snyder,
Brett Manning,
Nathaniel S. Bowden,
Jeremy Bundgaard,
Robert J. Casperson,
Daniel A. Cebra,
Timothy Classen,
Dana L. Duke,
Joshua Gearhart,
Uwe Greife,
Christian Hagmann,
Michael Heffner,
David Hensle,
Daniel Higgins,
Donald Isenhower,
Jonathan King,
Jennifer L. Klay,
Verena Geppert-Kleinrath,
Walter Loveland,
Joshua A. Magee,
Michael P. Mendenhall,
Samuele Sangiorgio,
Brandon Seilhan,
Kyle T. Schmitt,
Fredrik Tovesson
, et al. (5 additional authors not shown)
Abstract:
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some dr…
▽ More
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. For a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Reactors as a source of antineutrinos: the effect of fuel loading and burnup for mixed oxide fuels
Authors:
Adam Bernstein,
Nathaniel Bowden,
Anna Erickson
Abstract:
In a conventional light water reactor loaded with a range of uranium and plutonium-based fuel mixtures, the variation in antineutrino production over the cycle reflects both the initial core fissile inventory and its evolution. Under the assumption of constant thermal power, we calculate the rate at which antineutrinos are emitted from variously fueled cores, and the evolution of that rate as meas…
▽ More
In a conventional light water reactor loaded with a range of uranium and plutonium-based fuel mixtures, the variation in antineutrino production over the cycle reflects both the initial core fissile inventory and its evolution. Under the assumption of constant thermal power, we calculate the rate at which antineutrinos are emitted from variously fueled cores, and the evolution of that rate as measured by a representative ton-scale antineutrino detector. We find that antineutrino flux decreases with burnup for Low Enriched Uranium cores, increases for full mixed-oxide (MOX) cores, and does not appreciably change for cores with a MOX fraction of approximately 75%. Accounting for uncertainties in the fission yields, in the emitted antineutrino spectra, and the detector response function, we show that the difference in core-wide MOX fractions at least as small as 8% can be distinguished using a hypothesis test. The test compares the evolution of the antineutrino rate relative to an initial value over part or all of the cycle. The use of relative rates reduces the sensitivity of the test to an independent thermal power measurement, making the result more robust against possible countermeasures. This rate-only approach also offers the potential advantage of reducing the cost and complexity of the antineutrino detectors used to verify the diversion, compared to methods that depend on the use of the antineutrino spectrum. A possible application is the verification of the disposition of surplus plutonium in nuclear reactors.
△ Less
Submitted 5 December, 2016; v1 submitted 1 December, 2016;
originally announced December 2016.
-
Applied Antineutrino Physics 2015 -- Conference Summary
Authors:
N. S. Bowden,
K. M. Heeger,
P. Huber,
C. Mariani,
R. B. Vogelaar
Abstract:
This is a brief summary of the 11th Applied Antineutrino Physics 2015 workshop held at the Virginia Tech Arlington Research Facility from December 7-8, 2015.
This is a brief summary of the 11th Applied Antineutrino Physics 2015 workshop held at the Virginia Tech Arlington Research Facility from December 7-8, 2015.
△ Less
Submitted 15 February, 2016;
originally announced February 2016.
-
The PROSPECT Physics Program
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
C. D. Bryan,
J. P. Brodsky,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
B. W. Goddard
, et al. (39 additional authors not shown)
Abstract:
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both…
▽ More
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long distances. PROSPECT is conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino detector at distances of 7 - 12 m from the reactor core. It will probe the best-fit point of the $ν_e$ disappearance experiments at 4$σ$ in 1 year and the favored region of the sterile neutrino parameter space at $>$3$σ$ in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV$^{2}$ at 5$σ$ in 3 additional years. The measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent $θ_{13}$ experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.
△ Less
Submitted 7 December, 2015;
originally announced December 2015.
-
A search for cosmogenic production of $β$-neutron emitting radionuclides in water
Authors:
S. Dazeley,
M. Askins,
M. Bergevin,
A. Bernstein,
N. S. Bowden,
P. Jaffke,
S. D. Rountree,
T. M. Shokair,
M. Sweany
Abstract:
Here we present the first results of WATCHBOY, a water Cherenkov detector designed to measure the yield of $β$-neutron emitting radionuclides produced by cosmic ray muons in water. In addition to the $β$-neutron measurement, we also provide a first look at isolating single-$β$ producing radionuclides following muon-induced hadronic showers as a check of the detection capabilities of WATCHBOY. The…
▽ More
Here we present the first results of WATCHBOY, a water Cherenkov detector designed to measure the yield of $β$-neutron emitting radionuclides produced by cosmic ray muons in water. In addition to the $β$-neutron measurement, we also provide a first look at isolating single-$β$ producing radionuclides following muon-induced hadronic showers as a check of the detection capabilities of WATCHBOY. The data taken over $207$ live days indicates a $^{9}$Li production yield upper limit of $1.9\times10^{-7}μ^{-1}g^{-1}\mathrm{cm}^2$ at $\sim400$ meters water equivalent (m.w.e.) overburden at the $90\%$ confidence level. In this work the $^{9}$Li signal in WATCHBOY was used as a proxy for the combined search for $^{9}$Li and $^{8}$He production. This result will provide a constraint on estimates of antineutrino-like backgrounds in future water-based antineutrino detectors.
△ Less
Submitted 18 July, 2016; v1 submitted 2 December, 2015;
originally announced December 2015.
-
Light Collection and Pulse-Shape Discrimination in Elongated Scintillator Cells for the PROSPECT Reactor Antineutrino Experiment
Authors:
J. Ashenfelter,
B. Balantekin,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
A. Bowes,
J. P. Brodsky,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
K. Commeford,
D. Davee,
D. Dean,
G. Deichert,
M. V. Diwan,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn
, et al. (41 additional authors not shown)
Abstract:
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been stu…
▽ More
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron/gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell long axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. Key design features for optimizing MeV-scale response and background rejection capabilities are identified.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
Background Radiation Measurements at High Power Research Reactors
Authors:
J. Ashenfelter,
B. Balantekin,
C. X. Baldenegro,
H. R. Band,
G. Barclay,
C. D. Bass,
D. Berish,
N. S. Bowden,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
D. Davee,
D. Dean,
G. Deichert,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
S. Fan,
J. K. Gaison,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
M. Green,
K. Han
, et al. (36 additional authors not shown)
Abstract:
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are p…
▽ More
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including $γ$-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.
△ Less
Submitted 11 November, 2015; v1 submitted 11 June, 2015;
originally announced June 2015.
-
The Intermediate Neutrino Program
Authors:
C. Adams,
J. R. Alonso,
A. M. Ankowski,
J. A. Asaadi,
J. Ashenfelter,
S. N. Axani,
K. Babu,
C. Backhouse,
H. R. Band,
P. S. Barbeau,
N. Barros,
A. Bernstein,
M. Betancourt,
M. Bishai,
E. Blucher,
J. Bouffard,
N. Bowden,
S. Brice,
C. Bryan,
L. Camilleri,
J. Cao,
J. Carlson,
R. E. Carr,
A. Chatterjee,
M. Chen
, et al. (164 additional authors not shown)
Abstract:
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermedia…
▽ More
The US neutrino community gathered at the Workshop on the Intermediate Neutrino Program (WINP) at Brookhaven National Laboratory February 4-6, 2015 to explore opportunities in neutrino physics over the next five to ten years. Scientists from particle, astroparticle and nuclear physics participated in the workshop. The workshop examined promising opportunities for neutrino physics in the intermediate term, including possible new small to mid-scale experiments, US contributions to large experiments, upgrades to existing experiments, R&D plans and theory. The workshop was organized into two sets of parallel working group sessions, divided by physics topics and technology. Physics working groups covered topics on Sterile Neutrinos, Neutrino Mixing, Neutrino Interactions, Neutrino Properties and Astrophysical Neutrinos. Technology sessions were organized into Theory, Short-Baseline Accelerator Neutrinos, Reactor Neutrinos, Detector R&D and Source, Cyclotron and Meson Decay at Rest sessions.This report summarizes discussion and conclusions from the workshop.
△ Less
Submitted 1 April, 2015; v1 submitted 23 March, 2015;
originally announced March 2015.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
PROSPECT - A Precision Reactor Oscillation and Spectrum Experiment at Short Baselines
Authors:
J. Ashenfelter,
A. B. Balantekin,
H. R. Band,
G. Barclay,
C. Bass,
N. S. Bowden,
C. D. Bryan,
J. J. Cherwinka,
R. Chu,
T. Classen,
D. Davee,
D. Dean,
G. Deichert,
M. Diwan,
M. J. Dolinski,
J. Dolph,
D. A. Dwyer,
Y. Efremenko,
S. Fan,
A. Galindo-Uribarri,
K. Gilje,
A. Glenn,
M. Green,
K. Han,
S. Hans
, et al. (41 additional authors not shown)
Abstract:
Current models of antineutrino production in nuclear reactors predict detection rates and spectra at odds with the existing body of direct reactor antineutrino measurements. High-resolution antineutrino detectors operated close to compact research reactor cores can produce new precision measurements useful in testing explanations for these observed discrepancies involving underlying nuclear or new…
▽ More
Current models of antineutrino production in nuclear reactors predict detection rates and spectra at odds with the existing body of direct reactor antineutrino measurements. High-resolution antineutrino detectors operated close to compact research reactor cores can produce new precision measurements useful in testing explanations for these observed discrepancies involving underlying nuclear or new physics. Absolute measurement of the 235U-produced antineutrino spectrum can provide additional constraints for evaluating the accuracy of current and future reactor models, while relative measurements of spectral distortion between differing baselines can be used to search for oscillations arising from the existence of eV-scale sterile neutrinos. Such a measurement can be performed in the United States at several highly-enriched uranium fueled research reactors using near-surface segmented liquid scintillator detectors. We describe here the conceptual design and physics potential of the PROSPECT experiment, a U.S.-based, multi-phase experiment with reactor-detector baselines of 7-20 meters capable of addressing these and other physics and detector development goals. Current R&D status and future plans for PROSPECT detector deployment and data-taking at the High Flux Isotope Reactor at Oak Ridge National Laboratory will be discussed.
△ Less
Submitted 27 January, 2015; v1 submitted 29 September, 2013;
originally announced September 2013.
-
Reactor electron antineutrino disappearance in the Double Chooz experiment
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadón,
K. Crum
, et al. (140 additional authors not shown)
Abstract:
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted…
▽ More
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin^2 2θ13 = 0.109 \pm 0.030(stat) \pm 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).
△ Less
Submitted 30 August, 2012; v1 submitted 26 July, 2012;
originally announced July 2012.
-
A Note on Neutron Capture Correlation Signals, Backgrounds, and Efficiencies
Authors:
N. S. Bowden,
M. Sweany,
S. Dazeley
Abstract:
A wide variety of detection applications exploit the timing correlations that result from the slowing and eventual capture of neutrons. These include capture-gated neutron spectrometry, multiple neutron counting for fissile material detection and identification, and antineutrino detection. There are several distinct processes that result in correlated signals in these applications. Depending on th…
▽ More
A wide variety of detection applications exploit the timing correlations that result from the slowing and eventual capture of neutrons. These include capture-gated neutron spectrometry, multiple neutron counting for fissile material detection and identification, and antineutrino detection. There are several distinct processes that result in correlated signals in these applications. Depending on the application, one class of correlated events can be a background that is difficult to distinguish from the class that is of interest. Furthermore, the correlation timing distribution depends on the neutron capture agent and detector geometry. Here, we explain the important characteristics of the neutron capture timing distribution, making reference to simulations and data from a number of detectors currently in use or under development. We point out several features that may assist in background discrimination, and that must be carefully accounted for if accurate detection efficiencies are to be quoted.
△ Less
Submitted 2 February, 2012;
originally announced February 2012.
-
Investigation of Large LGB Detectors for Antineutrino Detection
Authors:
P. Nelson,
N. S. Bowden
Abstract:
A detector material or configuration that can provide an unambiguous indication of neutron capture can substantially reduce random coincidence backgrounds in antineutrino detection and capture-gated neutron spectrometry applications. Here we investigate the performance of such a material, a composite of plastic scintillator and $^6$Li$_6^{nat}$Gd$(^{10}$BO$_{3})_{3}$:Ce (LGB) crystal shards of ~1…
▽ More
A detector material or configuration that can provide an unambiguous indication of neutron capture can substantially reduce random coincidence backgrounds in antineutrino detection and capture-gated neutron spectrometry applications. Here we investigate the performance of such a material, a composite of plastic scintillator and $^6$Li$_6^{nat}$Gd$(^{10}$BO$_{3})_{3}$:Ce (LGB) crystal shards of ~1 mm dimension and comprising 1% of the detector by mass. While it is found that the optical propagation properties of this material as currently fabricated are only marginally acceptable for antineutrino detection, its neutron capture identification ability is encouraging.
△ Less
Submitted 29 June, 2011;
originally announced June 2011.
-
Large-scale Gadolinium-doped Water Cerenkov Detector for Non-Proliferation
Authors:
M. Sweany,
A. Bernstein,
N. S. Bowden,
S. Dazeley,
G. Keefer,
R. Svoboda,
M. Tripathi
Abstract:
Fission events from Special Nuclear Material (SNM), such as highly enriched uranium or plutonium, can produce simultaneous emission of multiple neutrons and high energy gamma-rays. The observation of time correlations between any of these particles is a significant indicator of the presence of fissionable material. Cosmogenic processes can also mimic these types of correlated signals. However, if…
▽ More
Fission events from Special Nuclear Material (SNM), such as highly enriched uranium or plutonium, can produce simultaneous emission of multiple neutrons and high energy gamma-rays. The observation of time correlations between any of these particles is a significant indicator of the presence of fissionable material. Cosmogenic processes can also mimic these types of correlated signals. However, if the background is sufficiently low and fully characterized, significant changes in the correlated event rate in the presence of a target of interest constitutes a robust signature of the presence of SNM. Since fission emissions are isotropic, adequate sensitivity to these multiplicities requires a high efficiency detector with a large solid angle with respect to the target. Water Cerenkov detectors are a cost-effective choice when large solid angle coverage is required. In order to characterize the neutron detection performance of large-scale water Cerenkov detectors, we have designed and built a 3.5 kL water Cerenkov-based gamma-ray and neutron detector, and modeled the detector response in Geant4 [1]. We report the position-dependent neutron detection efficiency and energy response of the detector, as well as the basic characteristics of the simulation.
△ Less
Submitted 11 May, 2011;
originally announced May 2011.
-
Directional Fast Neutron Detection Using a Time Projection Chamber
Authors:
N. S. Bowden,
M. Heffner,
G. Carosi,
D. Carter,
P. O'Malley,
J. Mintz,
M. Foxe,
I. Jovanovic
Abstract:
Measurement of the three dimensional trajectory and specific ionization of recoil protons using a hydrogen gas time projection chamber provides directional information about incident fast neutrons. Here we demonstrate directional fast neutron detection using such a device. The wide field of view and excellent gamma rejection that are obtained suggest that this device is well suited to searches for…
▽ More
Measurement of the three dimensional trajectory and specific ionization of recoil protons using a hydrogen gas time projection chamber provides directional information about incident fast neutrons. Here we demonstrate directional fast neutron detection using such a device. The wide field of view and excellent gamma rejection that are obtained suggest that this device is well suited to searches for special nuclear materials, among other applications.
△ Less
Submitted 6 October, 2010;
originally announced October 2010.
-
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
Authors:
C. E. Aalseth,
P. S. Barbeau,
N. S. Bowden,
B. Cabrera-Palmer,
J. Colaresi,
J. I. Collar,
S. Dazeley,
P. de Lurgio,
G. Drake,
J. E. Fast,
N. Fields,
C. H. Greenberg,
T. W. Hossbach,
M. E. Keillor,
J. D. Kephart,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
D. C. Radford,
D. Reyna,
R. G. H. Robertson,
R. L. Talaga,
O. Tench,
T. D. Van Wechel
, et al. (2 additional authors not shown)
Abstract:
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to t…
▽ More
We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.
△ Less
Submitted 15 March, 2010; v1 submitted 25 February, 2010;
originally announced February 2010.
-
Improved Fast Neutron Spectroscopy via Detector Segmentation
Authors:
N. S. Bowden,
P. Marleau,
J. T. Steele,
S. Mrowka,
G. Aigeldinger,
W. Mengesha
Abstract:
Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before depositing all of their energy within it. Second, fast neutrons will typically scatter several times within a detector, and there is a non-proportional relatio…
▽ More
Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before depositing all of their energy within it. Second, fast neutrons will typically scatter several times within a detector, and there is a non-proportional relationship between the energy of, and the scintillation light produced by, each individual scatter; therefore, there is not a deterministic relationship between the scintillation light observed and the neutron energy deposited. Here we demonstrate a hardware technique for reducing both of these effects. Use of a segmented detector allows for the event-by-event correction of the light yield non-proportionality and for the preferential selection of events with near-complete energy deposition, since these will typically have high segment multiplicities.
△ Less
Submitted 8 August, 2009;
originally announced August 2009.
-
Observation of Neutrons with a Gadolinium Doped Water Cerenkov Detector
Authors:
S. Dazeley,
A. Bernstein,
N. S. Bowden,
R. Svoboda
Abstract:
Spontaneous and induced fission in Special Nuclear Material (SNM) such as 235U and 239Pu results in the emission of neutrons and high energy gamma-rays. The multiplicities of and time correlations between these particles are both powerful indicators of the presence of fissile material. Detectors sensitive to these signatures are consequently useful for nuclear material monitoring, search, and ch…
▽ More
Spontaneous and induced fission in Special Nuclear Material (SNM) such as 235U and 239Pu results in the emission of neutrons and high energy gamma-rays. The multiplicities of and time correlations between these particles are both powerful indicators of the presence of fissile material. Detectors sensitive to these signatures are consequently useful for nuclear material monitoring, search, and characterization. In this article, we demonstrate sensitivity to both high energy gamma-rays and neutrons with a water Cerenkov based detector. Electrons in the detector medium, scattered by gamma-ray interactions, are detected by their Cerenkov light emission. Sensitivity to neutrons is enhanced by the addition of a gadolinium compound to the water in low concentrations. Cerenkov light is similarly produced by an 8 MeV gamma-ray cascade following neutron capture on the gadolinium. The large solid angle coverage and high intrinsic efficiency of this detection approach can provide robust and low cost neutron and gamma-ray detection with a single device.
△ Less
Submitted 1 August, 2008;
originally announced August 2008.
-
Experimental Results from an Antineutrino Detector for Cooperative Monitoring of Nuclear Reactors
Authors:
N. S. Bowden,
A. Bernstein,
M. Allen,
J. S. Brennan,
M. Cunningham,
J. K. Estrada,
C. M. R. Greaves,
C. Hagmann,
J. Lund,
W. Mengesha,
T. D. Weinbeck,
C. D. Winant
Abstract:
Our collaboration has designed, installed, and operated a compact antineutrino detector at a nuclear power station, for the purpose of monitoring the power and plutonium content of the reactor core. This paper focuses on the basic properties and performance of the detector. We describe the site, the reactor source, and the detector, and provide data that clearly show the expected antineutrino si…
▽ More
Our collaboration has designed, installed, and operated a compact antineutrino detector at a nuclear power station, for the purpose of monitoring the power and plutonium content of the reactor core. This paper focuses on the basic properties and performance of the detector. We describe the site, the reactor source, and the detector, and provide data that clearly show the expected antineutrino signal. Our data and experience demonstrate that it is possible to operate a simple, relatively small, antineutrino detector near a reactor, in a non-intrusive and unattended mode for months to years at a time, from outside the reactor containment, with no disruption of day-to-day operations at the reactor site. This unique real-time cooperative monitoring capability may be of interest for the International Atomic Energy Agency (IAEA) reactor safeguards program and similar regimes.
△ Less
Submitted 15 December, 2006;
originally announced December 2006.