Topologically Distinct Berry Phases in a Single Triangular Möbius Microwave Resonator
Authors:
E. C. I. Paterson,
M. E. Tobar,
M. Goryachev,
J. Bourhill
Abstract:
We report the experimental observation of two distinct Berry phases ($+\frac{2π}{3}$ and $-\frac{2π}{3}$) generated on the surface of a Möbius cavity resonator at microwave frequencies supporting the TE$_{1,0,n}$ mode family. This resonator consists of a twisted, mirror-asymmetric prism with a cross-section of the triangular $D_3$ symmetry group, bent around on itself to form a ring. This geometri…
▽ More
We report the experimental observation of two distinct Berry phases ($+\frac{2π}{3}$ and $-\frac{2π}{3}$) generated on the surface of a Möbius cavity resonator at microwave frequencies supporting the TE$_{1,0,n}$ mode family. This resonator consists of a twisted, mirror-asymmetric prism with a cross-section of the triangular $D_3$ symmetry group, bent around on itself to form a ring. This geometric class supports resonant modes with non-zero electromagnetic helicity (i.e. nonzero $\vec{E}\cdot\vec{B}$ product) at microwave frequencies. There exist modes with three-fold rotational symmetry as well as those that exhibit no rotational symmetry. The latter result in an accumulated Berry phase whilst the former do not, which is determined from the measured frequency shift of the modes when compared to a mirror-symmetric resonator of otherwise equivalent geometry.
△ Less
Submitted 26 May, 2025;
originally announced June 2025.
-
Electromagnetic Helicity in Twisted Cavity Resonators
Authors:
E. C. I. Paterson,
J. Bourhill,
M. E. Tobar,
M. Goryachev
Abstract:
Through left- or right-handed twisting, we investigate the impact of mirror-asymmetry (chirality) of the conducting boundary conditions of an equilaterial triangular cross-section electromagnetic resonator. We observe the generation of eigenmodes with non-zero electromagnetic helicity as a result of the coupling of near degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes. This can be interpreted as an…
▽ More
Through left- or right-handed twisting, we investigate the impact of mirror-asymmetry (chirality) of the conducting boundary conditions of an equilaterial triangular cross-section electromagnetic resonator. We observe the generation of eigenmodes with non-zero electromagnetic helicity as a result of the coupling of near degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes. This can be interpreted as an emergence of magneto-electric coupling, which in turn produces a measurable shift in resonant mode frequency as a function of twist angle. We show that this coupling mechanism is equivalent to introducing a non-zero chirality material parameter $κ_\text{eff}$ or axion field $θ_{\text{eff}}$ to the medium. Our findings demonstrate the potential for real-time, macroscopic manipulation of electromagnetic helicity.
△ Less
Submitted 23 June, 2025; v1 submitted 3 April, 2025;
originally announced April 2025.
-
Upconversion of Phonon Modes into Microwave Photons in a Lithium Niobate Bulk Acoustic Wave Resonator Coupled to a Microwave Cavity
Authors:
S. Parashar,
W. M. Campbell,
J. Bourhill,
E. N. Ivanov,
M. Goryachev,
M. E. Tobar
Abstract:
The coupling between acoustic vibrations in a lithium niobate bulk acoustic wave resonator and microwave photons of a re-entrant microwave cavity was investigated at a temperature close to 4 K. Coupling was achieved by placing the acoustic resonator in the location of the re-entrant cavity electric field maxima, in a symmetric "split-post" configuration, with a large overlap between the microwave…
▽ More
The coupling between acoustic vibrations in a lithium niobate bulk acoustic wave resonator and microwave photons of a re-entrant microwave cavity was investigated at a temperature close to 4 K. Coupling was achieved by placing the acoustic resonator in the location of the re-entrant cavity electric field maxima, in a symmetric "split-post" configuration, with a large overlap between the microwave field and the acoustic mode, allowing acoustic modulations of the microwave frequency. We show that the acoustic modes in this setup retain large inherent quality factors of greater than $10^6$. A maximum optomechanical coupling rate was determined to be $g_0$ = 0.014 mHz, four orders of magnitude larger than previous results obtained using a quartz BAW at 4 K in a similar experimental setup, but using a single post-re-entrant cavity resonator.
△ Less
Submitted 7 November, 2024; v1 submitted 26 October, 2024;
originally announced October 2024.
-
Sharp electromagnetically induced absorption via balanced interferometric excitation in a microwave resonator
Authors:
Michael Hatzon,
Graeme Flower,
Maxim Goryachev,
Jeremy Bourhill,
Michael E. Tobar
Abstract:
A cylindrical TM$_{0,1,0}$ mode microwave cavity resonator was excited using a balanced interferometric configuration that allowed manipulation of the electric field and potential within the resonator by adjusting the phase and amplitude of the interferometer arms driving the resonator. With precise tuning of the phase and amplitude, 25 dB suppression of the electric field at the resonance frequen…
▽ More
A cylindrical TM$_{0,1,0}$ mode microwave cavity resonator was excited using a balanced interferometric configuration that allowed manipulation of the electric field and potential within the resonator by adjusting the phase and amplitude of the interferometer arms driving the resonator. With precise tuning of the phase and amplitude, 25 dB suppression of the electric field at the resonance frequency was achieved while simultaneously resonantly enhancing the time-varying electric-scalar potential. Under these conditions, the system demonstrated electromagnetically induced absorption in the cavity response due to the annulment of the electric field at the resonance frequency. This phenomena can be regarded as a form of extreme dispersion, and led to a sharp increase in the cavity phase versus frequency response by an order of magnitude when compared to the cavity Q-factor. This work presents an experimental setup that will allow the electric-scalar Aharonov-Bohm effect to be tested under conditions involving a time-varying electric-scalar potential, without the presence of an electric field or magnetic vector potential, an experiment that has not yet been realised.
△ Less
Submitted 5 February, 2025; v1 submitted 2 October, 2024;
originally announced October 2024.
-
Microwave Cavity Mode Optimisation by Background Anti-Resonance Tuning
Authors:
Michael T. Hatzon,
Eugene N. Ivanov,
Jeremy F. Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high…
▽ More
To derive the best oscillator phase noise when implementing a high-Q resonator, the spectral line-shape must have high contrast and symmetry. Ideally, this line-shape is Lorentzian, however, in a high mode density spectral region, low-Q background spurious modes interact and distort the resonance. For a sapphire-loaded cavity resonator operating with whispering gallery modes we show that this high contrast and symmetry can be achieved by changing the dimensions of the surrounding cavity shield to tune the background low-Q structures into anti-resonance. This works because the high-Q resonances are primarily defined by the sapphire while the background modes are defined by the cavity shield. Alternatively, it was shown that a similar result can be achieved by exciting the high-Q resonator with a balanced microwave dipole probe in a Mach Zehnder interferometric configuration. The probe was constructed from two separate coaxial electric field probes symmetrically inserted into a cylindrical cavity resonator, from opposite sides with a small gap between them, so they can behave like an active wire dipole antenna. The power into the two separate probes may be matched with an external variable attenuator in one of the arms of the interferometer. Conversely, the phase between the two electric field probes may be changed with an external variable phase shifter, which changes the nature of the field components the probe couples to. The probe couples to the high-Q resonant modes as well as low-Q background modes, which can be made resonant or anti-resonant for the high-Q modes by changing this external phase. When the background modes are in anti-resonance the line shape of the high-Q mode can be made symmetric and with higher contrast. This technique was applied to both whispering gallery sapphire modes, as well as hollow cavity resonators, without changing the dimensions of the cavity.
△ Less
Submitted 13 July, 2024; v1 submitted 25 April, 2024;
originally announced May 2024.
-
Engineering synthetic gauge fields through the coupling phases in cavity magnonics
Authors:
Alan Gardin,
Guillaume Bourcin,
Jeremy Bourhill,
Vincent Vlaminck,
Christian Person,
Christophe Fumeaux,
Giuseppe C. Tettamanzi,
Vincent Castel
Abstract:
Cavity magnonics, which studies the interaction of light with magnetic systems in a cavity, is a promising platform for quantum transducers and quantum memories. At microwave frequencies, the coupling between a cavity photon and a magnon, the quasi-particle of a spin wave excitation, is a consequence of the Zeeman interaction between the cavity's magnetic field and the magnet's macroscopic spin. F…
▽ More
Cavity magnonics, which studies the interaction of light with magnetic systems in a cavity, is a promising platform for quantum transducers and quantum memories. At microwave frequencies, the coupling between a cavity photon and a magnon, the quasi-particle of a spin wave excitation, is a consequence of the Zeeman interaction between the cavity's magnetic field and the magnet's macroscopic spin. For each photon/magnon interaction, a coupling phase factor exists, but is often neglected in simple systems. However, in "loop-coupled" systems, where there are at least as many couplings as modes, the coupling phases become relevant for the physics and lead to synthetic gauge fields. We present experimental evidence of the existence of such coupling phases by considering two spheres made of Yttrium-Iron-Garnet and two different re-entrant cavities. We predict numerically the values of the coupling phases, and we find good agreement between theory and the experimental data. These results show that in cavity magnonics, one can engineer synthetic gauge fields, which can be useful for cavity-mediated coupling and engineering dark mode physics.
△ Less
Submitted 23 April, 2024; v1 submitted 8 December, 2023;
originally announced December 2023.
-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Searching for Ultra-Light Axions with Twisted Cavity Resonators of Anyon Rotational Symmetry with Bulk Modes of Non-Zero Helicity
Authors:
J. F. Bourhill,
E. C. I. Paterson,
M. Goryachev,
M. E. Tobar
Abstract:
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow…
▽ More
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow structures using equilateral triangular cross-sections, which leads to the realization of a cavity with anyon rotational symmetry. Unlike all previous cavity resonators, the anyon resonator permits the existence of bulk resonant modes that exhibit non-zero electromagnetic helicity in vacuo, with a non-zero overlap of the electric and magnetic mode eigenvectors, $\int \mathbf{E}_p\cdot\mathbf{B}_p~dτ$, integrated over the cavity volume. In the upconversion limit, we show that these non-zero helical modes couple naturally to ultra-light dark matter axions within the bandwidth of the resonator by adding amplitude-modulated sidebands through the axion-photon chiral anomaly. Thus, we show a sensitive ultra-light dark matter experiment may be realized by implementing such a resonator in an ultra-stable oscillator configuration and searching for signals in the Fourier spectrum of amplitude fluctuations. This removes the typical requirement for an external magnetic field and therefore permits the use of superconducting materials to reduce surface losses and enhance sensitivity to axions.
△ Less
Submitted 9 August, 2023; v1 submitted 1 August, 2022;
originally announced August 2022.
-
Generation of Coherent Phonons via a Cavity Enhanced Photonic Lambda Scheme
Authors:
Jeremy Bourhill,
Natalia do Carmo Carvalho,
Maxim Goryachev,
Serge Galliou,
Michael E. Tobar
Abstract:
We demonstrate the generation of coherent phonons in a quartz Bulk Acoustic Wave (BAW) resonator through the photoelastic properties of the crystal, via the coupling to a microwave cavity enhanced by a photonic lambda scheme. This is achieved by imbedding a single crystal BAW resonator between the post and the adjacent wall of a microwave reentrant cavity resonator. This 3D photonic lumped LC reso…
▽ More
We demonstrate the generation of coherent phonons in a quartz Bulk Acoustic Wave (BAW) resonator through the photoelastic properties of the crystal, via the coupling to a microwave cavity enhanced by a photonic lambda scheme. This is achieved by imbedding a single crystal BAW resonator between the post and the adjacent wall of a microwave reentrant cavity resonator. This 3D photonic lumped LC resonator at the same time acts as the electrodes of a BAW phonon resonator, and allows the direct readout of coherent phonons via the linear piezoelectric response of the quartz. A microwave pump, $ω_p$ is tuned to the cavity resonance $ω_0$, while a probe frequency, $ω_{probe}$, is detuned and varied around the red and blue detuned values with respect to the BAW phonon frequency, $Ω_m$. The pump and probe power dependence of the generated phonons unequivocally determines the process to be electrostrictive, with the phonons produced at the difference frequency between pump and probe, with no back action effects involved. Thus, the phonons are created without threshold and can be considered analogous to a Coherent Population Trapped (CPT) maser scheme.
△ Less
Submitted 8 October, 2020; v1 submitted 30 July, 2020;
originally announced August 2020.
-
Characterisation of Cryogenic Material Properties of 3D-Printed Superconducting Niobium using a 3D Lumped Element Microwave Cavity
Authors:
Ben T. McAllister,
Jeremy Bourhill,
Wing Him J. Ma,
Tim Sercombe,
Maxim Goryachev,
Michael E. Tobar
Abstract:
We present an experimental characterisation of the electrical properties of 3D-printed Niobium. The study was performed by inserting a 3D-printed Nb post inside an Aluminium cylindrical cavity, forming a 3D lumped element re-entrant microwave cavity resonator. The resonator was cooled to temperatures below the critical temperature of Niobium (9.25K) and then Aluminium (1.2K), while measuring the q…
▽ More
We present an experimental characterisation of the electrical properties of 3D-printed Niobium. The study was performed by inserting a 3D-printed Nb post inside an Aluminium cylindrical cavity, forming a 3D lumped element re-entrant microwave cavity resonator. The resonator was cooled to temperatures below the critical temperature of Niobium (9.25K) and then Aluminium (1.2K), while measuring the quality factors of the electromagnetic resonances. This was then compared with finite element analysis of the cavity and a measurement of the same cavity with an Aluminium post of similar dimensions and frequency, to extract the surface resistance of the Niobium post. The 3D-printed Niobium exhibited a transition to the superconducting state at a similar temperature to the regular Niobium, as well as a surface resistance of $3.1\times10^{-4}$ $Ω$. This value was comparable to many samples of traditionally machined Niobium previously studied without specialised surface treatment. Furthermore, this study demonstrates a simple new method for characterizing the material properties of a relatively small and geometrically simple sample of superconductor, which could be easily applied to other materials, particularly 3D-printed materials. Further research and development in additive manufacturing may see the application of 3D-printed Niobium in not only superconducting cavity designs, but in the innovative technology of the future.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.
-
Universal Characterisation of Cavity--Magnon Polariton Coupling Strength Verified in Modifiable Microwave Cavity
Authors:
Jeremy Bourhill,
Vincent Castel,
Alexandre Manchec,
Gwendal Cochet
Abstract:
A comprehensive study of the frequency dependence of the photon-magnon coupling for different magnetic samples is made possible with a tuneable 3D--printed re--entrant cavity. Strong coupling is achieved, with values ranging between 20--140 MHz. The reworked theory, experimentally verified for the first time here, enables coupling values to be calculated from simulations alone, enabling future exp…
▽ More
A comprehensive study of the frequency dependence of the photon-magnon coupling for different magnetic samples is made possible with a tuneable 3D--printed re--entrant cavity. Strong coupling is achieved, with values ranging between 20--140 MHz. The reworked theory, experimentally verified for the first time here, enables coupling values to be calculated from simulations alone, enabling future experiments with exotic cavity designs to be precisely engineered, with no limitations on sample and cavity geometry. Finally, the requirements of the deep strong coupling regime are shown to be achievable in such experiments.
△ Less
Submitted 27 August, 2020; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Piezo-optomechanical coupling of a 3D microwave resonator to a bulk acoustic wave crystalline resonator
Authors:
N. C. Carvalho,
J. Bourhill,
M. Goryachev,
S. Galliou,
M. E. Tobar
Abstract:
We report the observation of coupling between a 3D microwave cavity mode and a bulk mechanical resonator mediated by piezoelectric and radiation pressure effects. The system is composed of a quartz bulk acoustic wave resonator placed inside a microwave re-entrant cavity, which is designed to act as both the electrodes for piezoelectric actuation as well as a 3D resonator. The cavity electromagneti…
▽ More
We report the observation of coupling between a 3D microwave cavity mode and a bulk mechanical resonator mediated by piezoelectric and radiation pressure effects. The system is composed of a quartz bulk acoustic wave resonator placed inside a microwave re-entrant cavity, which is designed to act as both the electrodes for piezoelectric actuation as well as a 3D resonator. The cavity electromagnetic mode is modulated by a 5 MHz bulk acoustic wave shear mode, which is modeled and experimentally verified using the input-output formalism. Through finite element method simulations, we calculate the various contributions to the electromechanical coupling and discuss the potential of the system to reach high cooperativities as well as suitable applications.
△ Less
Submitted 15 September, 2019; v1 submitted 26 May, 2019;
originally announced July 2019.
-
Electrodynamic improvements to the theory of magnetostatic modes in ferrimagnetic spheres and their applications to saturation magnetization measurements
Authors:
Jerzy Krupka,
Adam Pacewicz,
Bartlomiej Salski,
Pawel Kopyt,
Jeremy Bourhill,
Maxim Goryachev,
Michael Tobar
Abstract:
Electrodynamic theory applied to the analysis of TEn0p mode resonances in ferromagnetic spheres placed either in metallic cavities or in the free space is compared with Walker-Fletcher's theory of so-called magnetostatic modes. The influence of the diameter of the sample, its permittivity and the permittivity of the surrounding media on the resonance frequencies of a few modes is analyzed. It is s…
▽ More
Electrodynamic theory applied to the analysis of TEn0p mode resonances in ferromagnetic spheres placed either in metallic cavities or in the free space is compared with Walker-Fletcher's theory of so-called magnetostatic modes. The influence of the diameter of the sample, its permittivity and the permittivity of the surrounding media on the resonance frequencies of a few modes is analyzed. It is shown that the dominant resonances are essentially related either to negative values of the diagonal component of the permeability tensor or, for clockwise circularly polarized magnetic fields, to negative effective permeability. The electrodynamic theory is used to determine the saturation magnetization (Ms) from measured TEn01 frequency differences. Measurements on different samples confirmed that Ms can be determined using an electrodynamic approach with uncertainties of the order of 2% regardless of sample sizes, metal enclosures or static magnetic field values.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Broadening Frequency Range of a Ferromagnetic Axion Haloscope with Strongly Coupled Cavity-Magnon Polaritons
Authors:
Graeme Flower,
Jeremy Bourhill,
Maxim Goryachev,
Michael E. Tobar
Abstract:
With the axion being a prime candidate for dark matter, there has been some recent interest in direct detection through a so called `Ferromagnetic haloscope.' Such devices exploit the coupling between axions and electrons in the form of collective spin excitations of magnetic materials with the readout through a microwave cavity. Here, we present a new, general, theoretical treatment of such exper…
▽ More
With the axion being a prime candidate for dark matter, there has been some recent interest in direct detection through a so called `Ferromagnetic haloscope.' Such devices exploit the coupling between axions and electrons in the form of collective spin excitations of magnetic materials with the readout through a microwave cavity. Here, we present a new, general, theoretical treatment of such experiments in a Hamiltonian formulation for strongly coupled magnons and photons, which hybridise as cavity-magnon polaritons. Such strongly coupled systems have an extended measurable dispersive regime. Thus, we extend the analysis and operation of such experiments into the dispersive regime, which allows any ferromagnetic haloscope to achieve improved bandwidth with respect to the axion mass parameter space. This experiment was implemented in a cryogenic setup, and initial search results are presented setting laboratory limits on the axion-electron coupling strength of $g_{aee}>3.7\times10^{-9}$ in the range $33.79~μ$eV$< m_a<33.94~μ$eV with $95\%$ confidence. The potential bandwidth of the Ferromagnetic haloscope was calculated to be in two bands, the first of about $1$GHz around $8.24$GHz (or $4.1~μ$eV mass range around $34.1~μ$eV) and the second of about $1.6$GHz around $10$GHz ($6.6~μ$eV mass range around $41.4~μ$eV). Frequency tuning may also be easily achieved via an external magnetic field which changes the ferromagnetic resonant frequency with respect to the cavity frequency. The requirements necessary for future improvements to reach the DFSZ axion model band are discussed in the paper.
△ Less
Submitted 29 March, 2019; v1 submitted 22 November, 2018;
originally announced November 2018.
-
Broadband Axion Dark Matter Haloscopes via Electric Sensing
Authors:
Ben T. McAllister,
Maxim Goryachev,
Jeremy Bourhill,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohi…
▽ More
The mass of axion dark matter is only weakly bounded by cosmological observations, necessitating a variety of detection techniques over several orders of magnitude of mass ranges. Axions haloscopes based on resonant cavities have become the current standard to search for dark matter axions. Such structures are inherently narrowband and for low masses the volume of the required cavity becomes prohibitively large. Broadband low-mass detectors have already been proposed using inductive magnetometer sensors and a gapped toroidal solenoid magnet. In this work we propose an alternative, which uses electric sensors in a conventional solenoidal magnet aligned in the laboratory z-axis, as implemented in standard haloscope experiments. In the presence of the DC magnetic field, the inverse Primakoff effect causes a time varying permanent electric vacuum polarization in the z-direction to oscillate at the axion Compton frequency, which induces an oscillating electromotive force. We propose non-resonant techniques to detect this oscillating elctromotive force by implementing a capacitive sensor or an electric dipole antenna coupled to a low noise amplifier. We present the first experimental results and discuss the foundations and potential of this proposal. Preliminary results constrain $g_{aγγ} >\sim2.35\times10^{-12}$ $\text{GeV}^{-1}$ in the mass range of $2.08\times10^{-11}$ to $2.2\times10^{-11}$ eV, and demonstrate potential sensitivity to axion-like dark matter with masses in the range of $10^{-12}$ to $10^{-8}$ eV.
△ Less
Submitted 26 October, 2018; v1 submitted 21 March, 2018;
originally announced March 2018.
-
Cavity Magnon Polaritons with Lithium Ferrite and 3D Microwave Resonators at milli-Kelvin Temperatures
Authors:
Maxim Goryachev,
Stuart Watt,
Jeremy Bourhill,
Mikhail Kostylev,
Michael E. Tobar
Abstract:
Single crystal Lithium Ferrite (LiFe) spheres of sub-mm dimension are examined at mK temperatures, microwave frequencies and variable DC magnetic field, for use in hybrid quantum systems and condensed matter and fundamental physics experiments. Strong coupling regimes of the photon-magnon interaction (cavity magnon polariton quasi-particles) were observed with coupling strength of up to 250 MHz at…
▽ More
Single crystal Lithium Ferrite (LiFe) spheres of sub-mm dimension are examined at mK temperatures, microwave frequencies and variable DC magnetic field, for use in hybrid quantum systems and condensed matter and fundamental physics experiments. Strong coupling regimes of the photon-magnon interaction (cavity magnon polariton quasi-particles) were observed with coupling strength of up to 250 MHz at 9.5 GHz (2.6\%) with magnon linewidths of order 4 MHz (with potential improvement to sub-MHz values). We show that the photon-magnon coupling can be significantly improved and exceed that of the widely used Yttrium Iron Garnet crystal, due to the small unit cell of LiFe, allowing twice more spins per unit volume. Magnon mode softening was observed at low DC fields and combined with the normal Zeeman effect creates magnon spin wave modes that are insensitive to first order order magnetic field fluctuations. This effect is observed in the Kittel mode at 5.5 GHz (and another higher order mode at 6.5 GHz) with a DC magnetic field close to 0.19 Tesla. We show that if the cavity is tuned close to this frequency, the magnon polariton particles exhibit an enhanced range of strong coupling and insensitivity to magnetic field fluctuations with both first order and second order insensitivity to magnetic field as a function of frequency (double magic point clock transition), which could potentially be exploited in cavity QED experiments.
△ Less
Submitted 22 March, 2018; v1 submitted 27 November, 2017;
originally announced November 2017.
-
The ORGAN Experiment: An axion haloscope above 15 GHz
Authors:
Ben T. McAllister,
Graeme Flower,
Justin Kruger,
Eugene N. Ivanov,
Maxim Goryachev,
Jeremy Bourhill,
Michael E. Tobar
Abstract:
We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of…
▽ More
We present first results and future plans for the Oscillating Resonant Group AxioN (ORGAN) experiment, a microwave cavity axion haloscope situated in Perth, Western Australia designed to probe for high mass axions motivated by several theoretical models. The first stage focuses around 26.6 GHz in order to directly test a claimed result, which suggests axions exist at the corresponding mass of $110~μ$eV. Later stages will move to a wider scan range of 15-50 GHz ($60-210~μ$eV). We present the results of the pathfinding run, which sets a limit on $g_{aγγ}$ of $2.02\times 10^{-12} $eV$^{-1}$ at 26.531 GHz, or 110~$μ$eV, in a span of 2.5 neV (shaped by the Lorentzian resonance) with $90 \%$ confidence. Furthermore, we outline the current design and future strategies to eventually attain the sensitivity to search for well known axion models over the wider mass range.
△ Less
Submitted 12 October, 2017; v1 submitted 1 June, 2017;
originally announced June 2017.
-
Sensitivity Characterisation of a Parametric Transducer for Gravitational Wave Detection Through Optical Spring Effect
Authors:
N. C. Carvalho,
O. D. Aguiar,
J. Bourhill,
M. E. Tobar
Abstract:
We present the characterisation of the most recent parametric transducers designed to enhance the Mario Schenberg Gravitational Wave Detector sensitivity. The transducer is composed of a microwave re-entrant cavity that attaches to the gravitational wave antenna via a rigid spring. It functions as a three-mode mass-spring system; motion of the spherical antenna couples to a 50 $μm$ thick membrane,…
▽ More
We present the characterisation of the most recent parametric transducers designed to enhance the Mario Schenberg Gravitational Wave Detector sensitivity. The transducer is composed of a microwave re-entrant cavity that attaches to the gravitational wave antenna via a rigid spring. It functions as a three-mode mass-spring system; motion of the spherical antenna couples to a 50 $μm$ thick membrane, which converts its mechanical motion into a frequency shift of the cavity resonance. Through the optical spring effect, the microwave transducer frequency-displacement sensitivity was measured to be 726 $MHz/μ$m at 4 K. The spherical antenna detection sensitivity is determined analytically using the transducer amplification gain and equivalent displacement noise in the test setup, which are 5.5 $\times$ 10$^{11} V/m$ and $1.8 \times 10^{-19} m\sqrt{Hz}^{-1}$, respectively.
△ Less
Submitted 24 July, 2017; v1 submitted 6 March, 2017;
originally announced March 2017.
-
Precision Measurement of a low-loss Cylindrical Dumbbell-Shaped Sapphire Mechanical Oscillator using Radiation Pressure
Authors:
Jeremy Bourhill,
Eugene Ivanov,
Michael Tobar
Abstract:
We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These t…
▽ More
We present first results from a number of experiments conducted on a 0.53 kg cylindrical dumbbell-shaped sapphire crystal. This is the first reported optomechanical experiment of this nature utilising a novel modification to the typical cylindrical architecture. Mechanical motion of the crystal structure alters the dimensions of the crystal, and the induced strain changes the permittivity. These two effects result in parametric frequency modulation of resonant microwave whispering gallery modes that are simultaneously excited within the crystal. A novel low-noise microwave readout system is implemented allowing extremely low noise measurements of this frequency modulation near our modes of interest, having a phase noise floor of -165 dBc/Hz at 100 kHz. Fine-tuning of the crystal's suspension has allowed for the optimisation of mechanical quality factors in preparation for cryogenic experiments, with a value of Q=8 x 10^7 achieved at 127 kHz. This results in a Q x f product of 10^13, equivalent to the best measured values in a macroscopic sapphire mechanical system. Results are presented that demonstrate the excitation of mechanical modes via radiation pressure force, allowing an experimental method of determining the transducer's displacement sensitivity df/dx, and calibrating the system. Finally, we demonstrate parametric back-action phenomenon within the system. These are all important steps towards the overall goal of the experiment; to cool a macroscopic device to the quantum ground state at millikelvin temperatures.
△ Less
Submitted 25 February, 2015; v1 submitted 25 February, 2015;
originally announced February 2015.
-
Spin bath maser in a cryogenically cooled sapphire whispering gallery mode resonator
Authors:
J. Bourhill,
K. Benmessai,
M. Goryachev,
D. L. Creedon,
W. G. Farr,
M. E. Tobar
Abstract:
We report the observation of a mechanism of maser generation in an ensemble of inter-coupled, inhomogeneously broadened two-level systems, enhanced by high quality factor electromagnetic cavity modes. In this previously unobserved form of population inversion, an inseparable quantum system leads to cavity-enhanced stimulated emission arising from interactions within an ensemble of two-level system…
▽ More
We report the observation of a mechanism of maser generation in an ensemble of inter-coupled, inhomogeneously broadened two-level systems, enhanced by high quality factor electromagnetic cavity modes. In this previously unobserved form of population inversion, an inseparable quantum system leads to cavity-enhanced stimulated emission arising from interactions within an ensemble of two-level systems, as opposed to a traditional ensemble of noninteracting identical three level systems. The effect is observed in a cryogenically cooled whispering gallery mode sapphire resonator containing dilute Fe$^{3+}$ impurity ions. These ions exhibit strong spin-lattice interaction, leading to both electron spin resonance broadening and phonon mediated spin-spin coupling. The maser effect is due to a $\left|1/2\right\rangle \rightarrow \left|3/2\right\rangle$ energy transition in electron spin angular momentum observed at zero external magnetic field. Both continuous and oscillating regimes are observed with corresponding thresholds both in detuning frequency and incident power.
△ Less
Submitted 4 December, 2013; v1 submitted 20 November, 2013;
originally announced November 2013.
-
Rigorous analysis of highly tunable cylindrical Transverse Magnetic mode re-entrant cavities
Authors:
J-M. Le Floch,
Y. Fan,
M. Aubourg,
D. Cros,
N. C. Carvalho,
Q. Shan,
J. Bourhill,
E. N. Ivanov,
G. Humbert,
V. Madrangeas,
M. E. Tobar
Abstract:
Cylindrical re-entrant cavities are unique three-dimensional structures that resonate with their electric and magnetic fields in separate parts of the cavity. To further understand these devices, we undertake rigorous analysis of the properties of the resonance using in-house developed Finite Element Method (FEM) software capable of dealing with small gap structures of extreme aspect ratio. Compar…
▽ More
Cylindrical re-entrant cavities are unique three-dimensional structures that resonate with their electric and magnetic fields in separate parts of the cavity. To further understand these devices, we undertake rigorous analysis of the properties of the resonance using in-house developed Finite Element Method (FEM) software capable of dealing with small gap structures of extreme aspect ratio. Comparisons between the FEM method and experiments are consistent and we illustrate where predictions using established lumped element models work well and where they are limited. With the aid of the modeling we design a highly tunable cavity that can be tuned from 2 GHz to 22 GHz just by inserting a post into a fixed dimensioned cylindrical cavity. We show this is possible as the mode structure transforms from a re-entrant mode during the tuning process to a standard cylindrical Transverse Magnetic (TM) mode.
△ Less
Submitted 8 January, 2014; v1 submitted 13 August, 2013;
originally announced August 2013.