-
Enantiospecificity in NMR Enabled by Chirality-Induced Spin Selectivity
Authors:
T. Georgiou,
J. L. Palma,
V. Mujica,
S. Varela,
M. Galante,
V. Santamarıa Garcıa,
L. Mboning,
R. N. Schwartz,
G. Cuniberti,
L. -S. Bouchard
Abstract:
Spin polarization in chiral molecules is a magnetic molecular response associated with electron transport and enantioselective bond polarization that occurs even in the absence of an external magnetic field. An unexpected finding by Santos and co-workers reported enantiospecific NMR responses in solid-state cross-polarization (CP) experiments, suggesting a possible additional contribution to the i…
▽ More
Spin polarization in chiral molecules is a magnetic molecular response associated with electron transport and enantioselective bond polarization that occurs even in the absence of an external magnetic field. An unexpected finding by Santos and co-workers reported enantiospecific NMR responses in solid-state cross-polarization (CP) experiments, suggesting a possible additional contribution to the indirect nuclear spin-spin coupling in chiral molecules induced by bond polarization in the presence of spin-orbit coupling. Herein we provide a theoretical treatment for this phenomenon, presenting an effective spin-Hamiltonian for helical molecules like DNA and density functional theory (DFT) results on amino acids that confirm the dependence of J-couplings on the choice of enantiomer. The connection between nuclear spin dynamics and chirality could offer insights for molecular sensing and quantum information sciences. These results establish NMR as a potential tool for chiral discrimination without external agents.
△ Less
Submitted 2 July, 2024; v1 submitted 30 June, 2024;
originally announced July 2024.
-
Diamond Magnetometry of Superconducting Thin Films
Authors:
A. Waxman,
H. Schlussel,
D. Groswasser,
V. M. Acosta,
L. -S. Bouchard,
D. Budker,
R. Folman
Abstract:
In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties…
▽ More
In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties of a thin-layer yttrium barium copper oxide (YBCO) superconductor. Using fluorescence-microscopy methods and samples integrated with an NV sensor on a microchip, we measure the temperature of phase transition in the layer to be 70.0(2) K, and the penetration field of vortices to be 46(4) G. We observe the pinning of the vortices in the layer at 65 K, and estimate their density after cooling the sample in a ~ 10 G field to be 0.45(1) μm^{-2}. These measurements are done with a 10 nm thick NV layer, so that high spatial resolution may be enabled in the future. Based on these results, we anticipate that this magnetometer could be useful for imaging the structure and dynamics of vortices. As an outlook, we present a fabrication method for a superconductor chip designed for this purpose.
△ Less
Submitted 5 February, 2014; v1 submitted 12 August, 2013;
originally announced August 2013.
-
Macro-scale Topology Optimization for Controlling Internal Shear Stress in a Porous Scaffold Bioreactor
Authors:
K. Youssef,
J. J. Mack,
M. L. Iruela-Arispe,
L. -S. Bouchard
Abstract:
Shear stress is an important physical factor that regulates proliferation, migration and morphogenesis. In particular, the homeostasis of blood vessels is dependent on shear stress. To mimic this process ex vivo, efforts have been made to seed scaffolds with vascular and other cell types in the presence of growth factors and under pulsatile flow conditions. However, the resulting bioreactors lack…
▽ More
Shear stress is an important physical factor that regulates proliferation, migration and morphogenesis. In particular, the homeostasis of blood vessels is dependent on shear stress. To mimic this process ex vivo, efforts have been made to seed scaffolds with vascular and other cell types in the presence of growth factors and under pulsatile flow conditions. However, the resulting bioreactors lack information on shear stress and flow distributions within the scaffold. Consequently, it is difficult to interpret the effects of shear stress on cell function. Such knowledge would enable researchers to improve upon cell culture protocols. Recent work has focused on optimizing the microstructural parameters of the scaffold to fine tune the shear stress. In this study, we have adopted a different approach whereby flows are redirected throughout the bioreactor along channels patterned in the porous scaffold to yield shear stress distributions that are optimized for uniformity centered on a target value. A topology optimization algorithm coupled to computational fluid dynamics simulations was devised to this end. The channel topology in the porous scaffold was varied using a combination of genetic algorithm and fuzzy logic. The method is validated by experiments using magnetic resonance imaging (MRI) readouts of the flow field.
△ Less
Submitted 9 January, 2012; v1 submitted 6 April, 2011;
originally announced April 2011.
-
Nuclear-spin relaxation of $^{207}$Pb in ferroelectric powders
Authors:
L. -S. Bouchard,
A. O. Sushkov,
D. Budker,
J. J. Ford,
A. S. Lipton
Abstract:
Motivated by a recent proposal by O. P. Sushkov and co-workers to search for a P,T-violating Schiff moment of the $^{207}$Pb nucleus in a ferroelectric solid, we have carried out a high-field nuclear magnetic resonance study of the longitudinal and transverse spin relaxation of the lead nuclei from room temperature down to 10 K for powder samples of lead titanate (PT), lead zirconium titanate (P…
▽ More
Motivated by a recent proposal by O. P. Sushkov and co-workers to search for a P,T-violating Schiff moment of the $^{207}$Pb nucleus in a ferroelectric solid, we have carried out a high-field nuclear magnetic resonance study of the longitudinal and transverse spin relaxation of the lead nuclei from room temperature down to 10 K for powder samples of lead titanate (PT), lead zirconium titanate (PZT), and a PT monocrystal. For all powder samples and independently of temperature, transverse relaxation times were found to be $T_2\approx 1.5 $ms, while the longitudinal relaxation times exhibited a temperature dependence, with $T_1$ of over an hour at the lowest temperatures, decreasing to $T_1\approx 7 $s at room temperature. At high temperatures, the observed behavior is consistent with a two-phonon Raman process, while in the low temperature limit, the relaxation appears to be dominated by a single-phonon (direct) process involving magnetic impurities. This is the first study of temperature-dependent nuclear-spin relaxation in PT and PZT ferroelectrics at such low temperatures. We discuss the implications of the results for the Schiff-moment search.
△ Less
Submitted 15 November, 2007; v1 submitted 8 November, 2007;
originally announced November 2007.
-
Detection of nuclear magnetic resonance with an anisotropic magnetoresistive sensor
Authors:
F. Verpillat,
M. P. Ledbetter,
D. Budker,
S. Xu,
D. Michalak,
C. Hilty,
S. Antonijevic,
A. Pines,
L. -S. Bouchard
Abstract:
We report detection of nuclear magnetic resonance (NMR) using an anisotropic magnetoresistive (AMR) sensor. A ``remote-detection'' arrangement was used, in which protons in flowing water were pre-polarized in the field of a superconducting NMR magnet, adiabatically inverted, and subsequently detected with an AMR sensor situated downstream from the magnet and the adiabatic inverter. AMR sensing i…
▽ More
We report detection of nuclear magnetic resonance (NMR) using an anisotropic magnetoresistive (AMR) sensor. A ``remote-detection'' arrangement was used, in which protons in flowing water were pre-polarized in the field of a superconducting NMR magnet, adiabatically inverted, and subsequently detected with an AMR sensor situated downstream from the magnet and the adiabatic inverter. AMR sensing is well suited for NMR detection in microfluidic ``lab-on-a-chip'' applications.
△ Less
Submitted 11 October, 2007;
originally announced October 2007.