-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Snowmass 2021 Instrumentation Frontier (IF5 - MPGDs) -- White Paper 2: Micro Pattern Gaseous Detectors for Nuclear Physics
Authors:
Fernando Barbosa,
Daniel Bazin,
Francesco Bossú,
Marco Cortesi,
Silvia Dalla Torre,
Sergey Furletov,
Yulia Furletova,
Paul Gueye,
Kondo Gnanvo,
Marcus Hohlmann,
Wolfgang Mittig,
Damien Neyret,
Matthiew Posik,
Christopher Wrede
Abstract:
Many current and future nuclear physics (NP) experiments across the United States have and are implementing micro-pattern gas detectors (MPGDs) to be used for tracking and PID purposes. MPGDs are capable of operating in high rate environments and providing excellent spatial resolution over a large-area with a low material budget. Summarized in this white paper is the role that MPGDs are playing in…
▽ More
Many current and future nuclear physics (NP) experiments across the United States have and are implementing micro-pattern gas detectors (MPGDs) to be used for tracking and PID purposes. MPGDs are capable of operating in high rate environments and providing excellent spatial resolution over a large-area with a low material budget. Summarized in this white paper is the role that MPGDs are playing in NP experiments and the R&D which is needed to meet the requirements of future NP experiments.
△ Less
Submitted 11 March, 2022;
originally announced March 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Performance of the RPC-based ALICE muon trigger system at the LHC
Authors:
Francesco Bossù,
Martino Gagliardi,
Massimiliano Marchisone,
ALICE Collaboration
Abstract:
The forward muon spectrometer of ALICE (A Large Ion Collider Experiment) is equipped with a trigger system made of four planes of Resistive Plate Chambers (RPC), arranged in two stations with two planes each, for a total area of about 140 m2 . The system provides single and di-muon triggers with suitable transverse momentum selection, optimised for the physics of quarkonia and open heavy flavour.…
▽ More
The forward muon spectrometer of ALICE (A Large Ion Collider Experiment) is equipped with a trigger system made of four planes of Resistive Plate Chambers (RPC), arranged in two stations with two planes each, for a total area of about 140 m2 . The system provides single and di-muon triggers with suitable transverse momentum selection, optimised for the physics of quarkonia and open heavy flavour. In the first two years of data-taking at the Large Hadron Collider (2010 and 2011) the 72 RPCs were operated in highly saturated avalanche mode in both pp and Pb-Pb collisions. The integrated charge was about 1.3 mC/cm2 on average and 3.5 mC/cm2 for the most exposed detectors. This paper describes two main results. The first result is the determination of the RPC performance, with particular focus on the stability of the main detector parameters such as efficiency, dark current, and dark rate. The second result is the measurement of the muon trigger performance in Pb-Pb collisions at sqrt(s_NN) = 2.76 TeV, in terms of the reliability and stability of the trigger decision logic.
△ Less
Submitted 8 November, 2012;
originally announced November 2012.