-
First image-guided treatment of a mouse tumor with radioactive ion beams
Authors:
Daria Boscolo,
Giulio Lovatti,
Olga Sokol,
Tamara Vitacchio,
Francesco Evangelista,
Emma Haettner,
Walter Tinganelli,
Christian Graeff,
Uli Weber,
Christoph Schuy,
Munetaka Nitta,
Martina Moglioni,
Daria Kostyleva,
Sivaji Purushothaman,
Peter G. Thirolf,
Jonathan Bortfeldt,
Christoph Scheidenberger,
Katia Parodi,
Marco Durante
Abstract:
Radioactive ion beams (RIB) are a key focus of current research in nuclear physics. Already long ago it was proposed that they could have applications in cancer therapy. In fact, while charged particle therapy is potentially the most effective radiotherapy technique available, it is highly susceptible to uncertainties in the beam range. RIB are well-suited for image-guided particle therapy, as iso…
▽ More
Radioactive ion beams (RIB) are a key focus of current research in nuclear physics. Already long ago it was proposed that they could have applications in cancer therapy. In fact, while charged particle therapy is potentially the most effective radiotherapy technique available, it is highly susceptible to uncertainties in the beam range. RIB are well-suited for image-guided particle therapy, as isotopes that undergo \b{eta}+-decay can be precisely visualized using positron emission tomography (PET), enabling accurate real-time monitoring of the beam range. We successfully treated a mouse osteosarcoma using a radioactive 11C-ion beam. The tumor was located in the neck, in close proximity to the spinal cord, increasing the risk of radiation-induced myelopathy from even slight variations in the beam range caused by anatomical changes or incorrect calibration of the planning CT. We managed to completely control the tumor with the highest dose while minimizing toxicity. Low-grade neurological side effects were correlated to the positron activity measured in the spine. The biological washout of the activity from the tumor volume was dependent on the dose, indicating a potential component of vascular damage at high doses. This experiment marks the first instance of tumor treatment using RIB and paves the way for future clinical applications.
△ Less
Submitted 1 April, 2025; v1 submitted 23 September, 2024;
originally announced September 2024.
-
Range margin reduction in carbon ion therapy: potential benefits of using radioactive ion beams
Authors:
Olga Sokol,
Laura Cella,
Daria Boscolo,
Felix Horst,
Caterina Oliviero,
Roberto Pacelli,
Giuseppe Palma,
Micol De Simoni,
Manuel Conson,
Mara Caroprese,
Ulrich Weber,
Christian Graeff,
Katia Parodi,
Marco Durante
Abstract:
Radiotherapy with heavy ions, in particular, 12C beams, is one of the most advanced forms of cancer treatment. Sharp dose gradients and high biological effectiveness in the target region make them an ideal tool to treat deep-seated and radioresistant tumors, however, at the same time, sensitive to small errors in the range prediction. Safety margins are added to the tumor volume to mitigate these…
▽ More
Radiotherapy with heavy ions, in particular, 12C beams, is one of the most advanced forms of cancer treatment. Sharp dose gradients and high biological effectiveness in the target region make them an ideal tool to treat deep-seated and radioresistant tumors, however, at the same time, sensitive to small errors in the range prediction. Safety margins are added to the tumor volume to mitigate these uncertainties and ensure its uniform coverage, but during the irradiation they lead to unavoidable damage to the surrounding healthy tissue. To fully exploit the benefits of a sharp Bragg peak, a large effort is put into establishing precise range verification methods for the so-called image-guided radiotherapy. Despite positron emission tomography being widely in use for this purpose in 12C ion therapy, the low count rates, biological washout, and broad shape of the activity distribution still limit its precision to a few millimeters. Instead, radioactive beams used directly for treatment would yield an improved signal and a closer match with the dose fall-off, potentially enabling precise in vivo beam range monitoring. We have performed a treatment planning study to estimate the possible impact of the reduced range uncertainties, enabled by radioactive 11C beams treatments, on sparing critical organs in the tumor proximity. We demonstrate that (i) annihilation maps for 11C ions can in principle reflect even millimeter shifts in dose distributions in the patient, (ii) outcomes of treatment planning with 11C beams are significantly improved in terms of meeting the constraints for the organs at risk compared to 12C plans, and (iii) less severe toxicities for serial and parallel critical organs can be expected following 11C treatment with reduced range uncertainties, compared to 12C treatments.
△ Less
Submitted 10 October, 2022;
originally announced October 2022.
-
May oxygen depletion explain the FLASH effect? A chemical track structure analysis
Authors:
Daria Boscolo,
Emanuele Scifoni,
Marco Durante,
Michael Krämer,
Martina C. Fuss
Abstract:
Background and purpose: Recent observations in animal models show that ultra-high dose rate ("FLASH") radiation treatment significantly reduces normal tissue toxicity maintaining an equivalent tumor control. The dependence of this "FLASH" effect on target oxygenation has led to the assumption that oxygen "depletion" could be its major driving force. Materials and Methods: In a bottom-up approach s…
▽ More
Background and purpose: Recent observations in animal models show that ultra-high dose rate ("FLASH") radiation treatment significantly reduces normal tissue toxicity maintaining an equivalent tumor control. The dependence of this "FLASH" effect on target oxygenation has led to the assumption that oxygen "depletion" could be its major driving force. Materials and Methods: In a bottom-up approach starting from the chemical track evolution of 1 MeV electrons in oxygenated water simulated with the TRAX-CHEM Monte Carlo code, we determine the oxygen consumption and radiolytic reactive oxygen species production following a short radiation pulse. Based on these values, the effective dose weighted by oxygen enhancement ratio (OER) or the in vitro cell survival under dynamic oxygen pressure is calculated and compared to that of conventional exposures, at constant OER. Results: We find an excellent agreement of our Monte Carlo predictions with the experimental value for radiolytic oxygen removal from oxygenated water. However, the application of the present model to published radiobiological experiment conditions shows that oxygen depletion can only have a negligible impact on radiosensitivity through oxygen enhancement, especially at typical experimental oxygenations where a FLASH effect has been observed. Conclusion: We show that the magnitude and dependence of the "oxygen depletion" hypothesis are not consistent with the observed biological effects of FLASH irradiation. While oxygenation plays an undoubted role in mediating the FLASH effect, we conclude that state-of-the-art radiation chemistry models do not support oxygen depletion and radiation-induced transient hypoxia as the main mechanism.
△ Less
Submitted 21 July, 2021; v1 submitted 22 January, 2021;
originally announced January 2021.