-
The development of IBIC microscopy at the 100 kV ion implanter of the University of Torino (LIUTo) and the application for the assessment of the radiation hardness of a silicon photodiode
Authors:
Emilio Corte,
Alberto Bortone,
Elena Nieto Hernández,
Carlo Ceresa,
Georgios Provatas,
Karla Ivanković Nizić,
Milko Jaksić,
Ettore Vittone,
Sviatoslav Ditalia Tchernij
Abstract:
The Ion Beam Induced Charge (IBIC) technique is widely used to characterize the electronic properties of semiconductor materials and devices. Its main advantage over other charge collection microscopies stems in the use of MeV ion probes, which provide both measurable induced charge signals from single ions, and high spatial resolution, which is maintained along the ion range. It is a fact, howeve…
▽ More
The Ion Beam Induced Charge (IBIC) technique is widely used to characterize the electronic properties of semiconductor materials and devices. Its main advantage over other charge collection microscopies stems in the use of MeV ion probes, which provide both measurable induced charge signals from single ions, and high spatial resolution, which is maintained along the ion range. It is a fact, however, that the use of low-energy ions in the keV range can provide the IBIC technique with complementary analytical capabilities, that are not available with MeV ions, for example the higher sensitivity to the status, contamination and morphology of the surface and the fact that the induced signal depends on the transport of only one type of charge carrier. This paper outlines the upgrade that was made at the 100 kV ion implanter of the University of Torino, originally installed for material and surface modification, to explore the rather unexplored keV-IBIC field and to assess its potential to characterize semiconductor devices. Finally, we report the first IBIC application of our apparatus, which regards the assessment of the radiation damage of a commercially available silicon photodiode, adopting the IAEA experimental protocol and the relevant interpretative model.
△ Less
Submitted 31 January, 2025;
originally announced January 2025.
-
Study of the decay and production properties of $D_{s1}(2536)$ and $D_{s2}^*(2573)$
Authors:
M. Ablikim,
M. N. Achasov,
P. Adlarson,
O. Afedulidis,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
I. Balossino,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann
, et al. (645 additional authors not shown)
Abstract:
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be…
▽ More
The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ processes are studied using data samples collected with the BESIII detector at center-of-mass energies from 4.530 to 4.946~GeV. The absolute branching fractions of $D_{s1}(2536)^- \rightarrow \bar{D}^{*0}K^-$ and $D_{s2}^*(2573)^- \rightarrow \bar{D}^0K^-$ are measured for the first time to be $(35.9\pm 4.8\pm 3.5)\%$ and $(37.4\pm 3.1\pm 4.6)\%$, respectively. The measurements are in tension with predictions based on the assumption that the $D_{s1}(2536)$ and $D_{s2}^*(2573)$ are dominated by a bare $c\bar{s}$ component. The $e^+e^-\rightarrow D_s^+D_{s1}(2536)^-$ and $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ cross sections are measured, and a resonant structure at around 4.6~GeV with a width of 50~MeV is observed for the first time with a statistical significance of $15σ$ in the $e^+e^-\rightarrow D_s^+D^*_{s2}(2573)^-$ process. It could be the $Y(4626)$ found by the Belle collaboration in the $D_s^+D_{s1}(2536)^{-}$ final state, since they have similar masses and widths. There is also evidence for a structure at around 4.75~GeV in both processes.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Development and operation of the CGEM Inner Tracker for the BESIII experiment
Authors:
Alberto Bortone
Abstract:
The extension of data acquisition for the BEijing Spectrometer (BESIII) experiment until at least 2030 has resulted in upgrades to both the accelerator and the detector. An innovative Cylindrical Gas Electron Multiplier (CGEM) is under construction to upgrade the inner tracker, which is suffering from aging. The CGEM Inner Tracker (CGEM -IT) was designed to restore efficiency and enhance the recon…
▽ More
The extension of data acquisition for the BEijing Spectrometer (BESIII) experiment until at least 2030 has resulted in upgrades to both the accelerator and the detector. An innovative Cylindrical Gas Electron Multiplier (CGEM) is under construction to upgrade the inner tracker, which is suffering from aging. The CGEM Inner Tracker (CGEM -IT) was designed to restore efficiency and enhance the reconstruction of the secondary vertexes position. Reconstruction in the magnetic field of 1 T requires an analog readout and an electronic contribution to the time resolution better than 5 ns. The entire system consists of about 10,000 electronic channels and must maintain a peak rate of 14 kHz/strip of signal hits for the innermost layer of the CGEM-IT. The CGEM readout system is based on the innovative TIGER ASIC, which is manufactured using 110 nm CMOS technology. A special readout chain consisting of GEM Read Out Cards (GEMROC) was developed for data acquisition. Two of three layers, equipped with the final electronics, have been operating in Beijing since January 2020 collecting cosmic ray data in a test facility, remotely controlled by the Italian group due to the pandemic situation. Since it was not possible to perform further tests on the cylindrical detector, in July 2021, a test beam was conducted at CERN with the final electronics configuration on a small prototype consisting of four triple-GEM planar detectors. In this presentation, the general status of the project CGEM-IT will be presented, with particular emphasis on the results of the test beam data collection.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Track-based alignment for the BESIII CGEM detector in the cosmic-ray test
Authors:
A. Q. Guo,
L. H. Wu,
L. L. Wang,
R. E. Mitchell,
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Y. Dong,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta
, et al. (27 additional authors not shown)
Abstract:
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical tri…
▽ More
The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.
△ Less
Submitted 14 December, 2022; v1 submitted 2 November, 2022;
originally announced November 2022.
-
Deployment of the readout electronics for the BESIII Cylindrical GEM Inner Tracker
Authors:
Alberto Bortone
Abstract:
The Beijing Spectrometer (BESIII) is an experimental setup located at the Beijing Electron Positron Collider (BEPCII). The recently approved ten-year extension of data acquisition for BESIII prompted an upgrade program for both the BEPCII collider that houses the experiment and some of the sub-detectors that make up the spectrometer. The current inner drift chamber is suffering from aging and it h…
▽ More
The Beijing Spectrometer (BESIII) is an experimental setup located at the Beijing Electron Positron Collider (BEPCII). The recently approved ten-year extension of data acquisition for BESIII prompted an upgrade program for both the BEPCII collider that houses the experiment and some of the sub-detectors that make up the spectrometer. The current inner drift chamber is suffering from aging and it has been proposed to replace it with a detector based on the Cylindrical Gas Electron Multiplier (CGEM) technology.
The CGEM Inner Tracker (CGEM-IT) consists of three coaxial layers of triple GEM. The lightweight tracker is designed to recover efficiency and improve z-determination and secondary vertex position reconstruction, resulting in a better performance and longer lifetime. A novel system has been deeloped for the readout of the CGEM detector, including a new ASIC, called TIGER (Torino Integrated GEM Electronics for Readout), designed to amplify and digitize the CGEM signals. The data output from TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, which is responsible for configuring and controlling the front-end ASICs. A second FPGA-based module, GEM Data Concentrator (GEM DC), builds the event packets and transmits them to the BESIII data acquisition system.
In this thesis I will describe the entire custom electronics chain designed for the CGEM-IT to achieve the desired performance.
The structure of my work is presented along with the results of the measurements performed on the detector and the analysis of the data obtained with the detection of cosmic rays and under test beam.
△ Less
Submitted 16 November, 2021; v1 submitted 2 November, 2021;
originally announced November 2021.
-
The CGEM-IT readout chain
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
R. Bugalho,
A. Calcaterra,
S. Cerioni,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
A. Di Francesco,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
S. Garbolino,
I. Garzia,
M. Gatta
, et al. (22 additional authors not shown)
Abstract:
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output b…
▽ More
An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
△ Less
Submitted 17 August, 2021; v1 submitted 19 May, 2021;
originally announced May 2021.
-
PARSIFAL: a toolkit for triple-GEM parametrized simulation
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
I. Garzia,
M. Gatta,
G. Giraudo,
S. Gramigna
, et al. (16 additional authors not shown)
Abstract:
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic f…
▽ More
PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic field, if present, and GEM amplification to provide the dependable triple-GEM detector response. In the design and optimization stages of this kind of detectors, simulations play an important role. Accurate and robust software programs, such as GARFIELD++, can simulate the transport of electrons and ions in a gas medium and their interaction with the electric field, but they are CPU-time consuming. The necessity to reduce the processing time while maintaining the precision of a full simulation is the main driver of this work. For a given set of geometrical and electrical settings, GARFIELD++ is run once-and-for-all to provide the input parameters for PARSIFAL. Once PARSIFAL is initialized and run, it produces the detector output, including the signal induction and the output of the electronics. The results of the analysis of the simulated data obtained with PARSIFAL are compared with the results of the experimental data collected during a testbeam: some tuning factors are applied to the simulation to improve the agreement. This paper describes the structure of the code and the methodology used to match the output to the experimental data.
△ Less
Submitted 7 June, 2023; v1 submitted 9 May, 2020;
originally announced May 2020.
-
Time performance of a triple-GEM detector at high rate
Authors:
A. Amoroso,
R. Baldini Ferroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
A. Calcaterra,
S. Cerioni,
W. Cheng,
G. Cibinetto,
A. Cotta Ramusino,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
A. Denig,
M. Destefanis,
J. Dong,
F. Evangelisti,
R. Farinelli,
L. Fava,
G. Felici,
B. Garillon,
I. Garzia,
M. Gatta,
G. Giraudo
, et al. (23 additional authors not shown)
Abstract:
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier a…
▽ More
Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.
△ Less
Submitted 10 April, 2020;
originally announced April 2020.
-
Triple GEM performance in magnetic field
Authors:
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferroli,
I. Balossino,
G. Bencivenni,
M. Bertani,
D. Bettoni,
F. Bianchi,
A. Bortone,
A. Calcaterra,
M. Capodiferro,
V. Carassiti,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
A. Cotta Ramusino,
G. Cotto,
F. Cossio,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
D. Domenici
, et al. (43 additional authors not shown)
Abstract:
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is…
▽ More
Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.
△ Less
Submitted 17 August, 2019;
originally announced August 2019.
-
GRAAL: Gem Reconstruction And Analysis Library
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. BaldiniFerroli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (25 additional authors not shown)
Abstract:
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysi…
▽ More
MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.
△ Less
Submitted 8 May, 2019;
originally announced May 2019.
-
A fast and parametric digitization for triple-GEM detectors
Authors:
R. Farinelli,
M. Alexeev,
A. Amoroso,
S. Bagnasco,
R. Baldini Ferrioli,
I. Balossino,
M. Bertani,
D. Bettoni,
A. Bortone,
F. Bianchi,
A. Calcaterra,
S. Cerioni,
J. Chai,
W. Cheng,
S. Chiozzi,
G. Cibinetto,
F. Cossio,
A. Cotta Ramusino,
G. Cotto,
M. Da Rocha Rolo,
F. De Mori,
M. Destefanis,
F. Evangelisti,
L. Fava,
G. Felici
, et al. (26 additional authors not shown)
Abstract:
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the…
▽ More
Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.
△ Less
Submitted 12 April, 2019;
originally announced April 2019.