-
Introducing advanced concepts for young students
Authors:
Paulo de F Borges
Abstract:
The compound Atwood's machine (Atm) problem is revisited in order to introduce young students on advanced concepts in Physics. Atm is an old-fashioned device. However, it allows us to speak about relativity of motion, principle of equivalence, inertial and non-inertial frames of reference, general covariance and invariance under coordinate transformations. Besides, it also provides experimental su…
▽ More
The compound Atwood's machine (Atm) problem is revisited in order to introduce young students on advanced concepts in Physics. Atm is an old-fashioned device. However, it allows us to speak about relativity of motion, principle of equivalence, inertial and non-inertial frames of reference, general covariance and invariance under coordinate transformations. Besides, it also provides experimental support for our theoretical models. We have started with coordinate transformations and inertial and non inertial reference frames followed by the principle of equivalence. The composed Atm was worked out in the following. We calculate the acceleration in the machine applying Newton's Laws to describe its dynamics in an inertial frame on the fixed pulley center and in a non-inertial one on the moving pulley center. Coordinate transformations mapping inertial frame solutions in non-inertial ones and vice-versa allow students catch on relativity concepts and the role played by general covariance. A comparison between these solutions showed the importance of the principle of equivalence in the evaluation of the intensity of gravity locally. In addition, according to this coordinate transformation the non-inertial reference frame equations of motion are equivalent to one single Atm plus one falling mass. Our results have also shown, in agreement with experimental outcomes, that after movement starts single Atm becomes lighter than $m_{3}$ mass, consequently $m_{3}$ mass is falling. It is a non-intuitive experimental result first observed for the 1854 Poggendorff's fall machine. A measure of single Atm's mass reduction was reported in 2016's last issue of Physics Education.
△ Less
Submitted 18 July, 2017;
originally announced August 2017.
-
Severe Vesico-ureteral Reflux and Urine Sequestration: Mathematical Relations and Urodynamic Consequences
Authors:
Lisieux Eyer de Jesus,
Paulo de Faria Borges
Abstract:
Some simple mathematical formulae to calculate the volumes of proximal pyeloureteral reflexive systems are presented, and the results are compared to bladder capacity values. Using the results of the calculi, the author discusses possible implications of severe urinary sequestration in the pyeloureteral systems. Using geometrical and topological approximations we calculate the volumes of ureters…
▽ More
Some simple mathematical formulae to calculate the volumes of proximal pyeloureteral reflexive systems are presented, and the results are compared to bladder capacity values. Using the results of the calculi, the author discusses possible implications of severe urinary sequestration in the pyeloureteral systems. Using geometrical and topological approximations we calculate the volumes of ureters and renal pelvises, applying in vivo measurements obtained from conventional ultrasound, retrograde cystourethrograms and topographic anatomic references. Approximations use 2 decimals and assumed $π$ value was 3.14. Ureteral and pyelic volumes are calculated, respectively, from the mathematical formula for the cylinder and cone volumes. Dolicomegaureter are compensated using proportional calculi. Bladder volumes are estimated from conventional formulae. Proximal urinary sequestration is compared between infants and older children with VUR. Mechanisms of direct induction of bladder urodynamic failure from VUR are suggested. Sequestration of urine in the ureter and renal pelvis can be estimated from mathematical formulae in patients with VUR. The values used derive from ultrasound examinations, CUM and topographical anatomical references. Primary VUR can determine urodynamic problems. Urine sequestration in the proximal urinary system is worse in infants than in older children.
△ Less
Submitted 3 February, 2009; v1 submitted 3 February, 2009;
originally announced February 2009.
-
Description of the Primary Relaxation in Supercooled Liquids Through the Timescale Steepness Function
Authors:
Valery B. Kokshenev,
Pablo D. Borges,
Neil S. Sullivan
Abstract:
The primary relaxation in glass forming supercooled liquids (SCLs) above the glass transformation temperature T_g is discussed in terms of the first-order (steepness) and the second-order (curvature) temperature derivatives of the observed primary relaxation timescale. We report new insights into the problem of the domain of the Vogel-Fulcher-Tamman (VFT) equation, raised by Stickel et al. (J. C…
▽ More
The primary relaxation in glass forming supercooled liquids (SCLs) above the glass transformation temperature T_g is discussed in terms of the first-order (steepness) and the second-order (curvature) temperature derivatives of the observed primary relaxation timescale. We report new insights into the problem of the domain of the Vogel-Fulcher-Tamman (VFT) equation, raised by Stickel et al. (J. Chem. Phys.,1995, 1996) and discussed by Richert and Angell (ibid., 1998). A new ergodic-cluster Gaussian statistical approach to the problem is given based on Onsager's thermodynamic principle. The primary relaxation is described by the VFT equation below the crossover temperature T_c (known from mode coupling theory (MCT)), and above T_c by an extended (VFTE) equation obtained after accounting for cluster-size fluctuations. The timescale is parametrized by a finite number of observable parameters such as the steepness function m_T, the MCT slowing-down exponent gamma_c, and the VFT and VFTE strength indices D_g and D_c. The latter are defined at T_g and T_c, respectively, for the strongly and moderately SCL states, which show absolute thermodynamic instability at the same VFT temperature T_0, associated with the Kauzmann temperature. For both states the limiting cluster-size characteristics are derived from experiment. A thermodynamic-dynamic correspondence is established between the dynamic VFT equation and the thermodynamic Adam and Gibbs model. The problem of the irregular SCLs, which are not consistent with the standard VFT equation, such as salol, ortho-terphenyl, and bis-methoxy-enyl-cyclohexane, is also discussed.
△ Less
Submitted 15 August, 2002;
originally announced August 2002.