-
Low-temperature AFM with a microwave cavity optomechanical transducer
Authors:
Ermes Scarano,
Elisabet K. Arvidsson,
August K. Roos,
Erik Holmgren,
Riccardo Borgani,
Mats O. Tholén,
David B. Haviland
Abstract:
We demonstrate AFM imaging with a microcantilever force transducer where an integrated superconducting microwave resonant circuit detects cantilever deflection using the principles of cavity optomechanics. We discuss the detector responsivity and added noise pointing to its crucial role in the context of force sensitivity. Through analysis of noise measurements we determine the effective temperatu…
▽ More
We demonstrate AFM imaging with a microcantilever force transducer where an integrated superconducting microwave resonant circuit detects cantilever deflection using the principles of cavity optomechanics. We discuss the detector responsivity and added noise pointing to its crucial role in the context of force sensitivity. Through analysis of noise measurements we determine the effective temperature of the cantilever eigenmode and we determine the region of detector operation in which the sensor is thermal-noise limited. Our analysis shows that the force-sensor design is a significant improvement over piezoelectric force sensors commonly used in low-temperature AFM. We discuss the potential for further improvement of the sensor design to achieve optimal detection at the standard quantum limit. We demonstrate AFM operation with surface-tracking feedback in both amplitude-modulation and frequency-modulation modes.
△ Less
Submitted 29 June, 2025;
originally announced June 2025.
-
Measurement and control of a superconducting quantum processor with a fully-integrated radio-frequency system on a chip
Authors:
Mats O. Tholén,
Riccardo Borgani,
Giuseppe Ruggero Di Carlo,
Andreas Bengtsson,
Christian Križan,
Marina Kudra,
Giovanna Tancredi,
Jonas Bylander,
Per Delsing,
Simone Gasparinetti,
David B. Haviland
Abstract:
We describe a digital microwave platform called Presto, designed for measurement and control of multiple quantum bits (qubits) and based on the third-generation radio-frequency system on a chip. Presto uses direct digital synthesis to create signals up to 9 GHz on 16 synchronous output ports, while synchronously analyzing response on 16 input ports. Presto has 16 DC-bias outputs, 4 inputs and 4 ou…
▽ More
We describe a digital microwave platform called Presto, designed for measurement and control of multiple quantum bits (qubits) and based on the third-generation radio-frequency system on a chip. Presto uses direct digital synthesis to create signals up to 9 GHz on 16 synchronous output ports, while synchronously analyzing response on 16 input ports. Presto has 16 DC-bias outputs, 4 inputs and 4 outputs for digital triggers or markers, and two continuous-wave outputs for synthesizing frequencies up to 15 GHz. Scaling to a large number of qubits is enabled through deterministic synchronization of multiple Presto units. A Python application programming interface configures a firmware for synthesis and analysis of pulses, coordinated by an event sequencer. The analysis integrates template matching (matched filtering) and low-latency (184 - 254 ns) feedback to enable a wide range of multi-qubit experiments. We demonstrate Presto's capabilities with experiments on a sample consisting of two superconducting qubits connected via a flux-tunable coupler. We show single-shot readout and active reset of a single qubit; randomized benchmarking of single-qubit gates showing 99.972% fidelity, limited by the coherence time of the qubit; and calibration of a two-qubit iSWAP gate.
△ Less
Submitted 31 October, 2022; v1 submitted 30 May, 2022;
originally announced May 2022.
-
IQ Mixer Calibration for Superconducting Circuits
Authors:
S. W. Jolin,
R. Borgani,
M. O. Tholén,
D. Forchheimer,
D. B. Haviland
Abstract:
An important device for modulation and frequency translation in the field of circuit quantum electrodynamics is the IQ mixer, an analog component for which calibration is necessary to achieve optimal performance. In this paper, we introduce techniques originally developed for wireless communication applications to calibrate upconversion and downconversion mixers. A Kalman filter together with a co…
▽ More
An important device for modulation and frequency translation in the field of circuit quantum electrodynamics is the IQ mixer, an analog component for which calibration is necessary to achieve optimal performance. In this paper, we introduce techniques originally developed for wireless communication applications to calibrate upconversion and downconversion mixers. A Kalman filter together with a controllable carrier frequency offset calibrates both mixers without removing them from the embedding measurement infrastructure. These techniques can be embedded into room temperature control electronics and they will find widespread use as circuit QED devices continue to grow in size and complexity.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
On modeling and measuring viscoelasticity with dynamic Atomic Force Microscopy
Authors:
Per-Anders Thorén,
Riccardo Borgani,
Daniel Forchheimer,
Illia Dobryden,
Per M. Claesson,
Hailu G. Kassa,
Philippe Leclère,
Yifan Wang,
Heinrich M. Jaeger,
David B. Haviland
Abstract:
The interaction between a rapidly oscillating atomic force microscope tip and a soft material surface is described using both elastic and viscous forces with a moving surface model. We derive the simplest form of this model, motivating it as a way to capture the impact dynamics of the tip and sample with an interaction consisting of two components: interfacial or surface force, and bulk or volumet…
▽ More
The interaction between a rapidly oscillating atomic force microscope tip and a soft material surface is described using both elastic and viscous forces with a moving surface model. We derive the simplest form of this model, motivating it as a way to capture the impact dynamics of the tip and sample with an interaction consisting of two components: interfacial or surface force, and bulk or volumetric force. Analytic solutions to the piece-wise linear model identify characteristic time constants, providing a physical explanation of the hysteresis observed in the measured dynamic force quadrature curves. Numerical simulation is used to fit the model to experimental data and excellent agreement is found with a variety of different samples. The model parameters form a dimensionless impact-rheology factor, giving a quantitative physical number to characterize a viscoelastic surface that does not depend on the tip shape or cantilever frequency.
△ Less
Submitted 21 May, 2018; v1 submitted 24 November, 2017;
originally announced November 2017.
-
A virtual instrument to standardise the calibration of atomic force microscope cantilevers
Authors:
John E. Sader,
Riccardo Borgani,
Christopher T. Gibson,
David B. Haviland,
Michael J. Higgins,
Jason I. Kilpatrick,
Jianing Lu,
Paul Mulvaney,
Cameron J. Shearer,
Ashley D. Slattery,
Per-Anders Thorén,
Jim Tran,
Heyou Zhang,
Hongrui Zhang,
Tian Zheng
Abstract:
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This is performed without reference to a global standard, which hinders robust comparison of force measurements reported by different laboratories. In this article, we describe a virtual instrument (an internet-based initiative) whereby users from all labor…
▽ More
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This is performed without reference to a global standard, which hinders robust comparison of force measurements reported by different laboratories. In this article, we describe a virtual instrument (an internet-based initiative) whereby users from all laboratories can instantly and quantitatively compare their calibration measurements to those of others - standardising AFM force measurements - and simultaneously enabling non-invasive calibration of AFM cantilevers of any geometry. This global calibration initiative requires no additional instrumentation or data processing on the part of the user. It utilises a single website where users upload currently available data. A proof-of-principle demonstration of this initiative is presented using measured data from five independent laboratories across three countries, which also allows for an assessment of current calibration.
△ Less
Submitted 25 May, 2016;
originally announced May 2016.