Study of a possible silicon photomultiplier based readout of the large plastic scintillator neutron detector NeuLAND
Authors:
Thomas Hensel,
David Weinberger,
Daniel Bemmerer,
Konstanze Boretzky,
Igor Gašparić,
Daniel Stach,
Andreas Wagner,
Kai Zuber
Abstract:
The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its final configuration, NeuLAND will consist of 3000 2.7 m $\times$ 5 cm $\times$ 5 cm big plastic scintillator bars that are read out on each end by fast timing phot…
▽ More
The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its final configuration, NeuLAND will consist of 3000 2.7 m $\times$ 5 cm $\times$ 5 cm big plastic scintillator bars that are read out on each end by fast timing photomultipliers.
Here, data from a comprehensive study of an alternative light readout scheme using silicon photomultipliers (SiPM) are reported. For this purpose, a NeuLAND bar was instrumented on each end with a SiPM-based prototype of the same geometry as a 1'' photomultiplier tube, including four 6 $\times$ 6 mm$^2$ SiPMs, amplifiers, high voltage supply, and microcontroller.
Tests were carried out using the 35 MeV electron beam from the superconducting Electron Linac for beams with high Brilliance and low Emittance (ELBE) with its picosecond-level time jitter in two different modes of operation, namely parasitic mode with one electron per bunch and single-user mode with 1-60 electrons per bunch. Acqiris fast digitisers were used for data acquisition. In addition, off-beam tests using cosmic rays and the NeuLAND data acquisition scheme have been carried out.
Typical time resolutions of $σ_t\leq$ 120 ps were found for $\geq$95% efficiency for minimum ionising particles, improving on previous work at ELBE and exceeding the NeuLAND timing goal of $σ_t$ < 150 ps. Over a range of 10-300 MeV deposited energy in the NeuLAND bar, the gain was found to deviate by $\leq$10% ($\leq$20%) from linearity for 35 mm (75 mm) SiPM pitch, respectively, satisfactory for calorimetric use of the full NeuLAND detector. The dark rate of the prototype studied was found to be lower than the expected cosmic-ray induced background in NeuLAND.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Classical and Machine Learning Methods for Event Reconstruction in NeuLAND
Authors:
Jan Mayer,
Konstanze Boretzky,
Christiaan Douma,
Elena Hoemann,
Andreas Zilges
Abstract:
NeuLAND, the New Large Area Neutron Detector, is a key component to investigate the origin of matter in the universe with experimental nuclear physics. It is a core component of the Reactions with Relativistic Radioactive Beams setup at the Facility for Antiproton and Ion Research, Germany. Neutrons emitted from these reactions create a wide range of patterns in NeuLAND. From these patterns, the n…
▽ More
NeuLAND, the New Large Area Neutron Detector, is a key component to investigate the origin of matter in the universe with experimental nuclear physics. It is a core component of the Reactions with Relativistic Radioactive Beams setup at the Facility for Antiproton and Ion Research, Germany. Neutrons emitted from these reactions create a wide range of patterns in NeuLAND. From these patterns, the number of neutrons (multiplicity) and their first interaction points must be reconstructed to determine the neutrons' four-momenta. In this paper, we detail the challenges involved in this reconstruction and present a range of possible solutions. Scikit-Learn classification models and simple Keras-based neural networks were trained on a wide range of input-scaler combinations and compared to classical models. While the improvement in multiplicity reconstruction is limited due to the overlap between features, the machine learning methods achieve a significantly better first interaction point selection, which directly improves the resolution of physical quantities.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Response of Multi-strip Multi-gap Resistive Plate Chamber
Authors:
Ushasi Datta,
S. Chakraborty,
A. Rahaman,
P. Basu,
J. Basu,
D. Bemmerer,
K. Boretzky,
Z. Elekes,
M. Kempe,
G. Munzenberg,
H. Simon,
M. Sobiella,
D. Stach,
A. Wagner,
D. Yakorev
Abstract:
A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The…
▽ More
A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The obtained time resolution ($σ_t$) of the detector after slew correction was 91.5$ \pm $3 ps. Position resolution measured along ($σ_x$) and across ($σ_y$) the strip was 2.8$\pm$0.6 cm and 0.58 cm, respectively. The measured absolute efficiency of the detector for minimum ionizing particle like electron was 95.8$\pm$1.3 $\%$. Better timing resolution of the detector can be achieved by restricting the events to a single strip. The response of the detector was mainly in avalanche mode but a few percentage of streamer mode response was also observed. A comparison of the response of these two modes with trigger rate was studied
△ Less
Submitted 15 January, 2016; v1 submitted 30 April, 2015;
originally announced April 2015.
-
Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons
Authors:
M. Röder,
Z. Elekes,
T. Aumann,
D. Bemmerer,
K. Boretzky,
C. Caesar,
T. E. Cowan,
J. Hehner,
M. Heil,
M. Kempe,
V. Maroussov,
O. Nusair,
A. V. Prokofiev,
R. Reifarth,
M. Sobiella,
D. Stach,
A. Wagner,
D. Yakorev,
A. Zilges,
K. Zuber
Abstract:
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypotheti…
▽ More
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment.
△ Less
Submitted 10 July, 2014; v1 submitted 23 June, 2014;
originally announced June 2014.