-
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
-
Scintillation Light Detection in Polycrystalline Diamond Using Single Photon Detectors
Authors:
Niccolò Gallice,
Aleksey Bolotnikov,
Erik M. Muller,
Thomas Tsang
Abstract:
This study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing di…
▽ More
This study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive ${}^6$LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.
△ Less
Submitted 13 February, 2025;
originally announced February 2025.
-
Neutrinoless Double Beta Decay Sensitivity of the XLZD Rare Event Observatory
Authors:
XLZD Collaboration,
J. Aalbers,
K. Abe,
M. Adrover,
S. Ahmed Maouloud,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
L. Althueser,
D. W. P. Amaral,
C. S. Amarasinghe,
A. Ames,
B. Andrieu,
N. Angelides,
E. Angelino,
B. Antunovic,
E. Aprile,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
M. Babicz,
D. Bajpai,
A. Baker,
M. Balzer,
J. Bang
, et al. (419 additional authors not shown)
Abstract:
The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60 to 80 t capable of probing the remaining WIMP-nucleon interaction parameter space down to the so-called neutrino fog. In this work we show that, based on the performance of currently operating detectors using the same technology and a realistic reduction of radioactivity in detector materials,…
▽ More
The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60 to 80 t capable of probing the remaining WIMP-nucleon interaction parameter space down to the so-called neutrino fog. In this work we show that, based on the performance of currently operating detectors using the same technology and a realistic reduction of radioactivity in detector materials, such an experiment will also be able to competitively search for neutrinoless double beta decay in $^{136}$Xe using a natural-abundance xenon target. XLZD can reach a 3$σ$ discovery potential half-life of 5.7$\times$10$^{27}$ yr (and a 90% CL exclusion of 1.3$\times$10$^{28}$ yr) with 10 years of data taking, corresponding to a Majorana mass range of 7.3-31.3 meV (4.8-20.5 meV). XLZD will thus exclude the inverted neutrino mass ordering parameter space and will start to probe the normal ordering region for most of the nuclear matrix elements commonly considered by the community.
△ Less
Submitted 30 April, 2025; v1 submitted 23 October, 2024;
originally announced October 2024.
-
The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
XLZD Collaboration,
J. Aalbers,
K. Abe,
M. Adrover,
S. Ahmed Maouloud,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
L. Althueser,
D. W. P. Amaral,
C. S. Amarasinghe,
A. Ames,
B. Andrieu,
N. Angelides,
E. Angelino,
B. Antunovic,
E. Aprile,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
M. Babicz,
A. Baker,
M. Balzer,
J. Bang,
E. Barberio
, et al. (419 additional authors not shown)
Abstract:
This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chambe…
▽ More
This report describes the experimental strategy and technologies for XLZD, the next-generation xenon observatory sensitive to dark matter and neutrino physics. In the baseline design, the detector will have an active liquid xenon target of 60 tonnes, which could be increased to 80 tonnes if the market conditions for xenon are favorable. It is based on the mature liquid xenon time projection chamber technology used in current-generation experiments, LZ and XENONnT. The report discusses the baseline design and opportunities for further optimization of the individual detector components. The experiment envisaged here has the capability to explore parameter space for Weakly Interacting Massive Particle (WIMP) dark matter down to the neutrino fog, with a 3$σ$ evidence potential for WIMP-nucleon cross sections as low as $3\times10^{-49}\rm\,cm^2$ (at 40 GeV/c$^2$ WIMP mass). The observatory will also have leading sensitivity to a wide range of alternative dark matter models. It is projected to have a 3$σ$ observation potential of neutrinoless double beta decay of $^{136}$Xe at a half-life of up to $5.7\times 10^{27}$ years. Additionally, it is sensitive to astrophysical neutrinos from the sun and galactic supernovae.
△ Less
Submitted 14 April, 2025; v1 submitted 22 October, 2024;
originally announced October 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
A Simple Model of Energy Threshold for Snowball Chambers
Authors:
M. Szydagis,
C. Levy,
A. E. Bolotnikov,
M. V. Diwan,
G. J. Homenides,
A. C. Kamaha,
J. Martin,
R. Rosero,
M. Yeh
Abstract:
Cloud and bubble chambers have historically been used for particle detection, capitalizing on supersaturation and superheating, respectively. Here we present new results from a prototype snowball chamber, in which an incoming particle triggers crystallization of a purified, supercooled liquid. We demonstrate, for the first time, simulation agreement with our first results from 5 years ago: the hig…
▽ More
Cloud and bubble chambers have historically been used for particle detection, capitalizing on supersaturation and superheating, respectively. Here we present new results from a prototype snowball chamber, in which an incoming particle triggers crystallization of a purified, supercooled liquid. We demonstrate, for the first time, simulation agreement with our first results from 5 years ago: the higher temperature of the freezing of water and significantly shorter time spent supercooled with respect to control in the presence of a Cf-252 fission neutron source. This is accomplished by combining Geant4 modeling of neutron interactions with the Seitz nucleation model used in superheated bubble chambers, including those seeking dark matter. We explore the possible implications of using this new technology for GeV-scale WIMP searches, especially in terms of spin-dependent proton coupling, and report the first supercooling of WbLS (water-based liquid scintillator).
△ Less
Submitted 26 January, 2024;
originally announced January 2024.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Front-end ASIC for Spectroscopic Readout of Virtual Frisch-Grid CZT Bar Sensors
Authors:
Emerson Vernon,
Gianluigi De Geronimo,
Aleksey Bolotnikov,
Milutin Stanacevic,
Jack Fried,
Luis Ocampo Giraldo,
Kevin Wolniewicz,
Kim Ackley,
Cynthia Salwen,
John Triolo,
Don Pinelli,
Kenny Luong
Abstract:
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at th…
▽ More
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than $\pm$ 1 % with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 x 4 array of 6 mm x 6 mm x 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of $\approx$ 270 rms $e^{-}$ for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8 % FWHM at 238 keV and 0.9 % FWHM at 662 keV.
△ Less
Submitted 2 April, 2019;
originally announced April 2019.
-
Effects of Bulk and Surface Conductivity on the Performance of CdZnTe Pixel Detectors
Authors:
Aleksey E. Bolotnikov,
C. M. Hubert Chen,
Walter R. Cook,
Fiona A. Harrison,
Irfan Kuvvetli,
Stephen M. Schindler
Abstract:
We studied the effects of bulk and surface conductivity on the performance of high-resistivity CdZnTe (CZT) pixel detectors with Pt contacts. We emphasize the difference in mechanisms of the bulk and surface conductivity as indicated by their different temperature behaviors. In addition, the existence of a thin (10-100 A) oxide layer on the surface of CZT, formed during the fabrication process,…
▽ More
We studied the effects of bulk and surface conductivity on the performance of high-resistivity CdZnTe (CZT) pixel detectors with Pt contacts. We emphasize the difference in mechanisms of the bulk and surface conductivity as indicated by their different temperature behaviors. In addition, the existence of a thin (10-100 A) oxide layer on the surface of CZT, formed during the fabrication process, affects both bulk and surface leakage currents. We demonstrate that the measured I-V dependencies of bulk current can be explained by considering the CZT detector as a metal-semiconductor-metal system with two back-to-back Schottky-barrier contacts. The high surface leakage current is apparently due to the presence of a low-resistivity surface layer that has characteristics which differ considerably from those of the bulk material. This surface layer has a profound effect on the charge collection efficiency in detectors with multi-contact geometry; some fraction of the electric field lines originated on the cathode intersects the surface areas between the pixel contacts where the charge produced by an ionizing particle gets trapped. To overcome this effect we place a grid of thin electrodes between the pixel contacts; when the grid is negatively biased, the strong electric field in the gaps between the pixels forces the electrons landing on the surface to move toward the contacts, preventing the charge loss. We have investigated these effects by using CZT pixel detectors indium bump bonded to a custom-built VLSI readout chip.
△ Less
Submitted 30 November, 2001;
originally announced December 2001.
-
Properties of Pt Schottky Type Contacts On High-Resistivity CdZnTe Detectors
Authors:
Aleksey E. Bolotnikov,
Steven E. Boggs,
C. M. Hubert Chen,
Walter R. Cook,
Fiona A. Harrison,
Stephen M. Schindler
Abstract:
In this paper we present studies of the I-V characteristics of CdZnTe detectors with Pt contacts fabricated from high-resistivity single crystals grown by the high-pressure Brigman process. We have analyzed the experimental I-V curves using a model that approximates the CZT detector as a system consisting of a reversed Schottky contact in series with the bulk resistance. Least square fits to the…
▽ More
In this paper we present studies of the I-V characteristics of CdZnTe detectors with Pt contacts fabricated from high-resistivity single crystals grown by the high-pressure Brigman process. We have analyzed the experimental I-V curves using a model that approximates the CZT detector as a system consisting of a reversed Schottky contact in series with the bulk resistance. Least square fits to the experimental data yield 0.78-0.79 eV for the Pt-CZT Schottky barrier height, and <20 V for the voltage required to deplete a 2 mm thick CZT detector. We demonstrate that at high bias the thermionic current over the Schottky barrier, the height of which is reduced due to an interfacial layer between the contact and CZT material, controls the leakage current of the detectors. In many cases the dark current is not determined by the resistivity of the bulk material, but rather the properties of the contacts; namely by the interfacial layer between the contact and CZT material.
△ Less
Submitted 1 March, 2001;
originally announced March 2001.