-
The LHCb VELO Upgrade Module Construction
Authors:
K. Akiba,
M. Alexander,
C. Bertella,
A. Biolchini,
A. Bitadze,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
K. Bridges,
M. Brock,
A. T. Burke,
J. Buytaert,
W. Byczynski,
J. Carroll,
V. Coco,
P. Collins,
A. Davis,
O. De Aguiar Francisco,
K. De Bruyn,
S. De Capua,
K. De Roo,
F. Doherty,
L. Douglas,
L. Dufour,
R. Dumps
, et al. (62 additional authors not shown)
Abstract:
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon dete…
▽ More
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.
△ Less
Submitted 21 April, 2024;
originally announced April 2024.
-
The BM@N spectrometer at the NICA accelerator complex
Authors:
S. Afanasiev,
G. Agakishiev,
E. Aleksandrov,
I. Aleksandrov,
P. Alekseev,
K. Alishina,
V. Astakhov,
E. Atkin,
T. Aushev,
V. Azorskiy,
V. Babkin,
N. Balashov,
R. Barak,
A. Baranov,
D. Baranov,
N. Baranova,
N. Barbashina,
M. Baznat,
S. Bazylev,
M. Belov,
D. Blau,
V. Bocharnikov,
G. Bogdanova,
A. Bolozdynya,
E. Bondar
, et al. (187 additional authors not shown)
Abstract:
BM@N (Baryonic Matter at Nuclotron) is the first experiment operating and taking data at the Nuclotron/NICA ion-accelerating complex.The aim of the BM@N experiment is to study interactions of relativistic heavy-ion beams with fixed targets. We present a technical description of the BM@N spectrometer including all its subsystems.
BM@N (Baryonic Matter at Nuclotron) is the first experiment operating and taking data at the Nuclotron/NICA ion-accelerating complex.The aim of the BM@N experiment is to study interactions of relativistic heavy-ion beams with fixed targets. We present a technical description of the BM@N spectrometer including all its subsystems.
△ Less
Submitted 11 March, 2024; v1 submitted 29 December, 2023;
originally announced December 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 10 September, 2024; v1 submitted 17 May, 2023;
originally announced May 2023.
-
Status and initial physics performance studies of the MPD experiment at NICA
Authors:
MPD Collaboration,
V. Abgaryan,
R. Acevedo Kado,
S. V. Afanasyev,
G. N. Agakishiev,
E. Alpatov,
G. Altsybeev,
M. Alvarado Hernández,
S. V. Andreeva,
T. V. Andreeva,
E. V. Andronov,
N. V. Anfimov,
A. A. Aparin,
V. I. Astakhov,
E. Atkin,
T. Aushev,
G. S. Averichev,
A. V. Averyanov,
A. Ayala,
V. A. Babkin,
T. Babutsidze,
I. A. Balashov,
A. Bancer,
M. Yu. Barabanov,
D. A. Baranov
, et al. (454 additional authors not shown)
Abstract:
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro…
▽ More
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document provides an overview of the landscape of the investigation of the QCD phase diagram in the region of maximum baryonic density, where NICA and MPD will be able to provide significant and unique input. It also provides a detailed description of the MPD set-up, including its various subsystems as well as its support and computing infrastructures. Selected performance studies for particular physics measurements at MPD are presented and discussed in the context of existing data and theoretical expectations.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform
Authors:
P. Kopciewicz,
T. Szumlak,
M. Majewski,
K. Akiba,
O. Augusto,
J. Back,
D. S. Bobulska,
G. Bogdanova,
S. Borghi,
T. Bowcock,
J. Buytaert,
E. Lemos Cid,
V. Coco,
P. Collins,
E. Dall'Occo,
K. de Bruyn,
S. de Capua,
F. Dettori,
K. Dreimanis,
D. Dutta,
L. Eklund,
T. Evans,
M. Ferro-Luzzi W. Funk,
L. Meyer Garcia,
O. Boente García
, et al. (41 additional authors not shown)
Abstract:
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in…
▽ More
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.
△ Less
Submitted 22 July, 2022; v1 submitted 16 June, 2020;
originally announced June 2020.
-
Mapping the material in the LHCb vertex locator using secondary hadronic interactions
Authors:
M. Alexander,
W. Barter,
A. Bay,
L. J. Bel,
M. van Beuzekom,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
E. Buchanan,
J. Buytaert,
K. Carvalho Akiba,
S. Chen,
V. Coco,
P. Collins,
A. Crocombe,
F. Da Cunha Marinho,
E. Dall'Occo,
S. De Capua,
C. T. Dean,
F. Dettori,
D. Dossett,
K. Dreimanis,
G. Dujany,
L. Eklund,
T. Evans
, et al. (41 additional authors not shown)
Abstract:
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties…
▽ More
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties of a reconstructed secondary vertex and its constituent tracks, a $p$-value can be assigned to the hypothesis that the secondary vertex originates from a material interaction. A validation of this procedure is presented using photon conversions to dimuons.
△ Less
Submitted 18 June, 2018; v1 submitted 20 March, 2018;
originally announced March 2018.
-
Performance of the LHCb Vertex Locator
Authors:
LHCb VELO Group,
R. Aaij,
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
R. B. Appleby,
M. Artuso,
A. Bates,
A. Bay,
O. Behrendt,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
A. Borgia,
T. J. V. Bowcock,
J. van den Brand,
H. Brown,
J. Buytaert,
O. Callot,
J. Carroll,
G. Casse,
P. Collins
, et al. (79 additional authors not shown)
Abstract:
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stabi…
▽ More
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.
△ Less
Submitted 10 September, 2014; v1 submitted 30 May, 2014;
originally announced May 2014.
-
Radiation damage in the LHCb Vertex Locator
Authors:
A. Affolder,
K. Akiba,
M. Alexander,
S. Ali,
M. Artuso,
J. Benton,
M. van Beuzekom,
P. M. Bjørnstad,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
H. Brown,
J. Buytaert,
G. Casse,
P. Collins,
S. De Capua,
D. Dossett,
L. Eklund,
C. Farinelli,
J. Garofoli,
M. Gersabeck,
T. Gershon,
H. Gordon,
J. Harrison,
V. Heijne
, et al. (26 additional authors not shown)
Abstract:
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the op…
▽ More
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\rm{45 \times 10^{12}\,1\,MeV}$ neutron equivalent ($\rm{1\,MeV\,n_{eq}}$). At the operational sensor temperature of approximately $-7\,^{\circ}\rm{C}$, the average rate of sensor current increase is $18\,\upmu\rm{A}$ per $\rm{fb^{-1}}$, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of $E_{g}=1.16\pm0.03\pm0.04\,\rm{eV}$ obtained. The first observation of n-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around $15 \times 10 ^{12}$ of $1\,\rm{MeV\,n_{eq}}$. The only n-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately $\rm{3 \times 10^{12}\,1\,MeV\,n_{eq}}$, a decrease in the Effective Depletion Voltage (EDV) of around 25\,V is observed, attributed to oxygen induced removal of boron interstitial sites. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n-on-n type sensors, with rates of $(1.43\pm 0.16) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ and $(1.35\pm 0.25) \times 10 ^{-12}\,\rm{V} / \, 1 \, \rm{MeV\,n_{eq}}$ measured for n-on-p and n-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed.
△ Less
Submitted 21 February, 2013;
originally announced February 2013.