-
The Muon Collider
Authors:
Carlotta Accettura,
Simon Adrian,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aime',
Avni Aksoy,
Gian Luigi Alberghi,
Siobhan Alden,
Luca Alfonso,
Muhammad Ali,
Anna Rita Altamura,
Nicola Amapane,
Kathleen Amm,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Ludovica Aperio Bella,
Rob Appleby,
Artur Apresyan,
Pouya Asadi,
Mohammed Attia Mahmoud,
Bernhard Auchmann,
John Back,
Anthony Badea,
Kyu Jung Bae
, et al. (433 additional authors not shown)
Abstract:
Muons offer a unique opportunity to build a compact high-energy electroweak collider at the 10 TeV scale. A Muon Collider enables direct access to the underlying simplicity of the Standard Model and unparalleled reach beyond it. It will be a paradigm-shifting tool for particle physics representing the first collider to combine the high-energy reach of a proton collider and the high precision of an…
▽ More
Muons offer a unique opportunity to build a compact high-energy electroweak collider at the 10 TeV scale. A Muon Collider enables direct access to the underlying simplicity of the Standard Model and unparalleled reach beyond it. It will be a paradigm-shifting tool for particle physics representing the first collider to combine the high-energy reach of a proton collider and the high precision of an electron-positron collider, yielding a physics potential significantly greater than the sum of its individual parts. A high-energy muon collider is the natural next step in the exploration of fundamental physics after the HL-LHC and a natural complement to a future low-energy Higgs factory. Such a facility would significantly broaden the scope of particle colliders, engaging the many frontiers of the high energy community.
The last European Strategy for Particle Physics Update and later the Particle Physics Project Prioritisation Panel in the US requested a study of the muon collider, which is being carried on by the International Muon Collider Collaboration. In this comprehensive document we present the physics case, the state of the work on accelerator design and technology, and propose an R\&D project that can make the muon collider a reality.
△ Less
Submitted 30 April, 2025;
originally announced April 2025.
-
MuCol Milestone Report No. 5: Preliminary Parameters
Authors:
Carlotta Accettura,
Simon Adrian,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aimé,
Avni Aksoy,
Gian Luigi Alberghi,
Siobhan Alden,
Luca Alfonso,
Nicola Amapane,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Rob Appleby,
Artur Apresyan,
Pouya Asadi,
Mohammed Attia Mahmoud,
Bernhard Auchmann,
John Back,
Anthony Badea,
Kyu Jung Bae,
E. J. Bahng,
Lorenzo Balconi,
Fabrice Balli,
Laura Bandiera
, et al. (369 additional authors not shown)
Abstract:
This document is comprised of a collection of updated preliminary parameters for the key parts of the muon collider. The updated preliminary parameters follow on from the October 2023 Tentative Parameters Report. Particular attention has been given to regions of the facility that are believed to hold greater technical uncertainty in their design and that have a strong impact on the cost and power…
▽ More
This document is comprised of a collection of updated preliminary parameters for the key parts of the muon collider. The updated preliminary parameters follow on from the October 2023 Tentative Parameters Report. Particular attention has been given to regions of the facility that are believed to hold greater technical uncertainty in their design and that have a strong impact on the cost and power consumption of the facility. The data is collected from a collaborative spreadsheet and transferred to overleaf.
△ Less
Submitted 5 November, 2024;
originally announced November 2024.
-
Interim report for the International Muon Collider Collaboration (IMCC)
Authors:
C. Accettura,
S. Adrian,
R. Agarwal,
C. Ahdida,
C. Aimé,
A. Aksoy,
G. L. Alberghi,
S. Alden,
N. Amapane,
D. Amorim,
P. Andreetto,
F. Anulli,
R. Appleby,
A. Apresyan,
P. Asadi,
M. Attia Mahmoud,
B. Auchmann,
J. Back,
A. Badea,
K. J. Bae,
E. J. Bahng,
L. Balconi,
F. Balli,
L. Bandiera,
C. Barbagallo
, et al. (362 additional authors not shown)
Abstract:
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accele…
▽ More
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.
△ Less
Submitted 28 January, 2025; v1 submitted 17 July, 2024;
originally announced July 2024.
-
Practice Makes Better: Quantifying Grade Benefits of Study
Authors:
William K. Black,
Rebecca L. Matz,
Mark Mills,
A. E. Evrard
Abstract:
Problem Roulette (PR), an online study service at the University of Michigan, offers points-free formative practice to students preparing for examinations in introductory STEM courses. Using four years of PR data involving millions of problem attempts by thousands of students, we quantify benefits of increased practice study volume in introductory physics. After conditioning mean final grade on st…
▽ More
Problem Roulette (PR), an online study service at the University of Michigan, offers points-free formative practice to students preparing for examinations in introductory STEM courses. Using four years of PR data involving millions of problem attempts by thousands of students, we quantify benefits of increased practice study volume in introductory physics. After conditioning mean final grade on standardized (ACT/SAT) math test score, we analyze deviations based on student study volume. We find a strong effect; mean course grade rises quadratically with the logarithm of the total number of PR questions encountered over the term ($N_{\rm Q,tot}$), with an overall gain of $0.77 \pm 0.12$ grade points between $1 < N_{\rm Q,tot} < 1000$. The gains are persistent across the range of math test score represented in our sample. While $N_{\rm Q,tot}$ surely correlates with other study habits, the benefits of increased study in general still hold. A model for final grade using test score and study volume largely accounts for demographic stratification, including by sex, parental education level, number of parents at home, nationality / underrepresented minority status, and regional income level, with two significant exceptions: students whose parents did not earn a college degree, who earn $-0.27 \pm 0.04$ grade points ($6.1σ$) below expectations and underrepresented minority students at $-0.14 \pm 0.04$ points ($3.6σ$). Residual scatter in final grade remains comparable to the maximal study gains, implying that the model is far from deterministic: individual variation trumps mean trends. Our findings can help motivate students to study more and help teachers to identify which types of students may especially need such encouragement.
△ Less
Submitted 29 April, 2023; v1 submitted 7 January, 2023;
originally announced January 2023.
-
Report of the Topical Group on Micro-Pattern Gaseous Detectors for Snowmass 2021
Authors:
B. Surrow,
M. Titov,
S. Vahsen,
A. Bellerive,
K. Black,
A. Colaleo,
K. Dehmelt,
K. Gnanvo,
P. Lewis,
D. Loomba,
C. O'Hare,
M. Posik,
A. White
Abstract:
This report summarizes white papers on micro-pattern gaseous detectors (MPGDs) that were submitted to the Instrumentation Frontier Topical Group IF05, as part of the Snowmass 2021 decadal survey of particle physics.
This report summarizes white papers on micro-pattern gaseous detectors (MPGDs) that were submitted to the Instrumentation Frontier Topical Group IF05, as part of the Snowmass 2021 decadal survey of particle physics.
△ Less
Submitted 16 September, 2022; v1 submitted 1 September, 2022;
originally announced September 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Strategy for Understanding the Higgs Physics: The Cool Copper Collider
Authors:
Sridhara Dasu,
Emilio A. Nanni,
Michael E. Peskin,
Caterina Vernieri,
Tim Barklow,
Rainer Bartoldus,
Pushpalatha C. Bhat,
Kevin Black,
Jim Brau,
Martin Breidenbach,
Nathaniel Craig,
Dmitri Denisov,
Lindsey Gray,
Philip C. Harris,
Michael Kagan,
Zhen Liu,
Patrick Meade,
Nathan Majernik,
Sergei Nagaitsev,
Isobel Ojalvo,
Christoph Paus,
Carl Schroeder,
Ariel G. Schwartzman,
Jan Strube,
Su Dong
, et al. (4 additional authors not shown)
Abstract:
A program to build a lepton-collider Higgs factory, to precisely measure the couplings of the Higgs boson to other particles, followed by a higher energy run to establish the Higgs self-coupling and expand the new physics reach, is widely recognized as a primary focus of modern particle physics. We propose a strategy that focuses on a new technology and preliminary estimates suggest that can lead…
▽ More
A program to build a lepton-collider Higgs factory, to precisely measure the couplings of the Higgs boson to other particles, followed by a higher energy run to establish the Higgs self-coupling and expand the new physics reach, is widely recognized as a primary focus of modern particle physics. We propose a strategy that focuses on a new technology and preliminary estimates suggest that can lead to a compact, affordable machine. New technology investigations will provide much needed enthusiasm for our field, resulting in trained workforce. This cost-effective, compact design, with technologies useful for a broad range of other accelerator applications, could be realized as a project in the US. Its technology innovations, both in the accelerator and the detector, will offer unique and exciting opportunities to young scientists. Moreover, cost effective compact designs, broadly applicable to other fields of research, are more likely to obtain financial support from our funding agencies.
△ Less
Submitted 7 June, 2022; v1 submitted 15 March, 2022;
originally announced March 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
MPGDs for tracking and Muon detection at future high energy physics colliders
Authors:
K. Black,
A. Colaleo,
C. Aimè,
M. Alviggi,
C. Aruta,
M. Bianco,
I. Balossino,
G. Bencivenni,
M. Bertani,
A. Braghieri,
V. Cafaro,
S. Calzaferri,
M. T. Camerlingo,
V. Canale,
G. Cibinetto,
M. Corbetta,
V. D'Amico,
E. De Lucia,
M. Della Pietra,
C. Di Donato,
R. Di Nardo,
D. Domenici,
F. Errico,
P. Everaerts,
F. Fallavollita
, et al. (39 additional authors not shown)
Abstract:
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high backgro…
▽ More
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the envisaged construction of new machines at energy scales up to hundreds TeV or with unprecedented intensity (FCC-hh, FCC-ee, ILC, Muon Collider). Large size, cost-effective, high-efficiency detection systems in high background environments are required in order to accomplish the physics program. MPGDs offer a diversity of technologies that allow them to meet the required performance challenges at future facilities thanks to the specific advantages that each technology provides. MPGDs allow stable operation, with environmentally friendly gas mixtures, at very high background particle flux with high detection efficiency and excellent spatial resolution. These features make MPGD one of the primary choices as precise muon tracking and trigger system in general-purpose detectors at future HEP colliders. In addition, the low material budget and the flexibility of the base material make MPGDs suitable for the development of very light, full cylindrical fine tracking inner trackers at lepton colliders. On-going R&Ds aim at pushing the detector performance at the limits of each technology. We are working in continuing to consolidate the construction and stable operation of large-size detectors, able to cope with large particle fluxes. In this white paper, we describe some of the most prominent MPGD technologies, their performance measurements, the challenges faced in the most recent applications, and the areas of improvement towards efficient tracking and Muon detection at future high energy physics colliders.
△ Less
Submitted 12 March, 2022;
originally announced March 2022.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.
-
Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays
Authors:
M. A. Leutenegger,
M. E. Eckart,
S. J. Moseley,
S. O. Rohrbach,
J. K. Black,
M. P. Chiao,
R. L. Kelley,
C. A. Kilbourne,
F. S. Porter
Abstract:
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the…
▽ More
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
△ Less
Submitted 13 August, 2020;
originally announced August 2020.
-
Photoelectron track length distributions measured in a negative ion time projection chamber
Authors:
Z. R. Prieskorn,
J. E. Hill,
P. E. Kaaret,
J. K. Black
Abstract:
We report photoelectron track length distributions between 3 and 8 keV in gas mixtures of Ne+CO2+CH3NO2 (260:80:10 Torr) and CO2+CH3NO2 (197.5: 15 Torr). The measurements were made using a negative ion time projection chamber (NITPC) at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). We report the first quantitative analysis of photoelectron track length d…
▽ More
We report photoelectron track length distributions between 3 and 8 keV in gas mixtures of Ne+CO2+CH3NO2 (260:80:10 Torr) and CO2+CH3NO2 (197.5: 15 Torr). The measurements were made using a negative ion time projection chamber (NITPC) at the National Synchrotron Light Source (NSLS) at the Brookhaven National Laboratory (BNL). We report the first quantitative analysis of photoelectron track length distributions in a gas. The distribution of track lengths at a given energy is best fit by a lognormal distribution. A powerlaw distribution of the form, f(E)=a(E/Eo)n, is found to fit the relationship between mean track length and energy. We find n=1.29 +/- 0.07 for Ne+CO2+CH3NO2 and n=1.20 +/- 0.09 for CO2+CH3NO2. Understanding the distribution of photoelectron track lengths in proportional counter gases is important for optimizing the pixel size and the dimensions of the active region in electron-drift time projection chambers (TPCs) and NITPC X-ray polarimeters.
△ Less
Submitted 17 June, 2014;
originally announced June 2014.
-
Gas Gain Measurements from a Negative Ion TPC X-ray Polarimeter
Authors:
Z. Prieskorn,
J. E. Hill,
P. E. Kaaret,
J. K. Black,
K. Jahoda
Abstract:
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good mo…
▽ More
Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray emission of a Gamma-ray burst (GRB), a large area detector is needed. Diffusion of the electron cloud in a standard TPC could be prohibitive to measuring good modulation when the drift distance is large. Therefore, we propose using a negative ion TPC (NITPC) with Nitromethane (CH3NO2) as the electron capture agent. The diffusion of negative ions is reduced over that of electrons due to the thermal coupling of the negative ions to the surrounding gas. This allows for larger area detectors as the drift distance can be increased without degrading polarimeter modulation. Negative ions also travel ~200 times slower than electrons, allowing the readout electronics to operate slower, resulting in a reduction of instrument power. To optimize the NITPC design, we have measured gas gain with SciEnergy gas electron multipliers (GEMs) in single and double GEM configurations. Each setup was tested with different gas combinations, concentrations and pressures: P10 700 Torr, Ne+CO2 700 Torr at varying concentrations of CO2 and Ne+CO2+CH3NO2 700 Torr. We report gain as a function of total voltage, measured from top to bottom of the GEM stack, and as a function of drift field strength for the gas concentrations listed above. Examples of photoelectron tracks at 5.9 keV are also presented.
△ Less
Submitted 5 August, 2013; v1 submitted 15 July, 2011;
originally announced July 2011.
-
A benign, low Z electron capture agent for negative ion TPCs
Authors:
C. J. Martoff,
M. P. Dion,
M. Hosack,
D. Barton,
J. K. Black
Abstract:
We have identified nitromethane (CH$_3$NO$_2$) as an effective electron capture agent for negative ion TPCs (NITPCs).
We present drift velocity and longitudinal diffusion measurements for negative ion gas mixtures using nitromethane as the capture agent.
Not only is nitromethane substantially more benign than the only other identified capture agent, CS$_2$, but its low atomic number will ena…
▽ More
We have identified nitromethane (CH$_3$NO$_2$) as an effective electron capture agent for negative ion TPCs (NITPCs).
We present drift velocity and longitudinal diffusion measurements for negative ion gas mixtures using nitromethane as the capture agent.
Not only is nitromethane substantially more benign than the only other identified capture agent, CS$_2$, but its low atomic number will enable the use of the NITPC as a photoelectric X{}-ray polarimeter in the 1{}-10 keV band.
△ Less
Submitted 20 August, 2009;
originally announced August 2009.
-
Understanding the use of two integration methods on separable first order differential equations
Authors:
Katrina E. Black,
Michael C. Wittmann
Abstract:
We present evidence from three student interactions in which two types of common solution methods for solving simple first-order differential equations are used. We describe these using the language of resources, considering epistemic games as particular pathways of solutions along resource graphs containing linked procedural and conceptual resources. Using transcript data, we define several pro…
▽ More
We present evidence from three student interactions in which two types of common solution methods for solving simple first-order differential equations are used. We describe these using the language of resources, considering epistemic games as particular pathways of solutions along resource graphs containing linked procedural and conceptual resources. Using transcript data, we define several procedural resources, show how they can be organized into two facets of a previously described epistemic game, and produce a resource graph that allows visualization of this portion of the epistemic games. By representing two correct mathematical procedures in terms of shared resources, we help clarify the types of thinking in which students engage when learning to apply mathematical reasoning to physics and illustrate how a "failure to connect" two ideas often hinders students' successful problem solving.
△ Less
Submitted 4 February, 2009;
originally announced February 2009.
-
Visualizing changes in student responses using consistency plots
Authors:
Katrina E. Black,
Michael C. Wittmann
Abstract:
Traditional methods of reporting changes in student responses have focused on class-wide averages. Such models hide information about the switches in responses by individual students over the course of a semester. We extend unpublished work by Steven Kanim on "escalator diagrams" which show changes in student responses from correct to incorrect (and vice versa) while representing pre- and post-i…
▽ More
Traditional methods of reporting changes in student responses have focused on class-wide averages. Such models hide information about the switches in responses by individual students over the course of a semester. We extend unpublished work by Steven Kanim on "escalator diagrams" which show changes in student responses from correct to incorrect (and vice versa) while representing pre- and post-instruction results on questions. Our extension consists of "consistency plots" in which we represent three forms of data: method of solution and correctness of solution both before and after instruction. Our data are from an intermediate mechanics class, and come from (nearly) identical midterm and final examination questions.
△ Less
Submitted 16 December, 2008;
originally announced December 2008.
-
The D0 Run II Impact Parameter Trigger
Authors:
T. Adams,
Q. An,
K. M. Black,
T. Bose,
N. J. Buchanan,
S. Caron,
D. K. Cho,
S. Choi,
A. Das,
M. Das,
H. Dong,
W. Earle,
H. Evans,
S. N. Fatakia,
L. Feligioni,
T. Fitzpatrick,
E. Hazen,
U. Heintz,
K. Herner,
J. D. Hobbs,
D. Khatidze,
W. M. Lee,
S. L. Linn,
M. Narain,
C. Pancake
, et al. (18 additional authors not shown)
Abstract:
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as…
▽ More
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as part of the DO detector upgrade for Run II. Interesting events must be identified initially in 100-200 microseconds to be available for later study. This paper describes custom electronics used in the DO trigger system to provide the real--time identification of events having tracks consistent with the decay of b--flavored particles.
△ Less
Submitted 17 January, 2007;
originally announced January 2007.
-
The imaging X-ray detector for Lobster-ISS
Authors:
J. K. Black,
A. N. Brunton,
N. P. Bannister,
P. Deines-Jones,
K. Jahoda
Abstract:
Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled for deployment as an attached payload on the International Space Station (ISS) in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an order-of-magnitude improvement in the sensitivity of all-sky monitors in the soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique challenges to t…
▽ More
Lobster-ISS is a revolutionary astrophysical X-ray all-sky monitor scheduled for deployment as an attached payload on the International Space Station (ISS) in 2009. Using a new wide field-of-view focusing optic, Lobster-ISS provides an order-of-magnitude improvement in the sensitivity of all-sky monitors in the soft X-ray band (0.1-3.0 keV). This lobster-eye optic presents unique challenges to the imaging X-ray detector at its focus. Micro-patterned imaging proportional counters, with thier mechanical simplicity and high performance, are the most practical means of meeting the requirements. We describe our design for the Lobster-ISS imaging detector based on direct-imaging micro-well proportional counters and the expected performance.
△ Less
Submitted 7 May, 2003;
originally announced May 2003.
-
X-ray polarimetry with an active-matrix pixel proportional counter
Authors:
J. K. Black,
P. Deines-Jones,
S. E. Ready,
R. A. Street
Abstract:
We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suit…
▽ More
We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.
△ Less
Submitted 27 March, 2003;
originally announced March 2003.