-
The CIPM list "Recommended values of standard frequencies": 2021 update
Authors:
H S Margolis,
G Panfilo,
G Petit,
C Oates,
T Ido,
S Bize
Abstract:
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures (CIPM). This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods fo…
▽ More
This paper gives a detailed account of the analysis underpinning the 2021 update to the list of standard reference frequency values recommended by the International Committee for Weights and Measures (CIPM). This update focused on a subset of atomic transitions that are secondary representations of the second (SRS) or considered as potential SRS. As in previous updates in 2015 and 2017, methods for analysing over-determined data sets were applied to make optimum use of the worldwide body of published clock comparison data. To ensure that these methods were robust, three independent calculations were performed using two different algorithms. The 2021 update differed from previous updates in taking detailed account of correlations among the input data, a step shown to be important in deriving unbiased frequency values and avoiding underestimation of their uncertainties. It also differed in the procedures used to assess input data and to assign uncertainties to the recommended frequency values, with previous practice being adapted to produce a fully consistent output data set consisting of frequency ratio values as well as absolute frequencies. These changes are significant in the context of an anticipated redefinition of the second in terms of an optical transition or transitions, since optical frequency ratio measurements will be critical for verifying the international consistency of optical clocks prior to the redefinition. In the meantime, the reduced uncertainties for optical SRS resulting from this analysis significantly increases the weight that secondary frequency standards based on these transitions can have in the steering of International Atomic Time (TAI).
△ Less
Submitted 25 January, 2024;
originally announced January 2024.
-
Roadmap towards the redefinition of the second
Authors:
N. Dimarcq,
M. Gertsvolf,
G. Mileti,
S. Bize,
C. W. Oates,
E. Peik,
D. Calonico,
T. Ido,
P. Tavella,
F. Meynadier,
G. Petit,
G. Panfilo,
J. Bartholomew,
P. Defraigne,
E. A. Donley,
P. O. Hedekvist,
I. Sesia,
M. Wouters,
P. Dube,
F. Fang,
F. Levi,
J. Lodewyck,
H. S. Margolis,
D. Newell,
S. Slyusarev
, et al. (12 additional authors not shown)
Abstract:
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the ne…
▽ More
This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements and the open challenges related to the status of the optical frequency standards, their contribution to time scales and UTC, the possibility of their comparison and the knowledge of the Earth's gravitational potential at the necessary level of uncertainty are discussed. In addition, the mandatory criteria to be achieved before redefinition and their current fulfilment level, together with the redefinition options based on a single or on a set of transitions are described.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
-
Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
Authors:
Ivan Alonso,
Cristiano Alpigiani,
Brett Altschul,
Henrique Araujo,
Gianluigi Arduini,
Jan Arlt,
Leonardo Badurina,
Antun Balaz,
Satvika Bandarupally,
Barry C Barish Michele Barone,
Michele Barsanti,
Steven Bass,
Angelo Bassi,
Baptiste Battelier,
Charles F. A. Baynham,
Quentin Beaufils,
Aleksandar Belic,
Joel Berge,
Jose Bernabeu,
Andrea Bertoldi,
Robert Bingham,
Sebastien Bize,
Diego Blas,
Kai Bongs,
Philippe Bouyer
, et al. (224 additional authors not shown)
Abstract:
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, a…
▽ More
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
Accurate laser frequency locking to optical frequency combs under low-signal-to-noise-ratio conditions
Authors:
C. Guo,
M. Favier,
N. Galland,
V. Cambier,
H. Álvarez-Martínez,
M. Lours,
L. De Sarlo,
M. Andia,
R. Le Targat,
S. Bize
Abstract:
We demonstrate a method for accurately locking the frequency of a continuous-wave laser to an optical frequency comb in conditions where the signal-to-noise ratio is low, too low to accommodate other methods. Our method is typically orders of magnitude more accurate than conventional wavemeters and can considerably extend the usable wavelength range of a given optical frequency comb. We illustrate…
▽ More
We demonstrate a method for accurately locking the frequency of a continuous-wave laser to an optical frequency comb in conditions where the signal-to-noise ratio is low, too low to accommodate other methods. Our method is typically orders of magnitude more accurate than conventional wavemeters and can considerably extend the usable wavelength range of a given optical frequency comb. We illustrate our method by applying it to the frequency control of a dipole lattice trap for an optical lattice clock, a representative case where our method provides significantly better accuracy than other methods.
△ Less
Submitted 23 March, 2020;
originally announced March 2020.
-
The unit of time: present and future directions
Authors:
S. Bize
Abstract:
Some 50~years ago, physicists, and after them the entire world, started to found their time reference on atomic properties instead of motions of the Earth that have been in use since the origin. Far from being an arrival point, this decision marked the beginning of an adventure characterized by a 6 orders of magnitude improvement in the uncertainty of realization of atomic frequency and time refer…
▽ More
Some 50~years ago, physicists, and after them the entire world, started to found their time reference on atomic properties instead of motions of the Earth that have been in use since the origin. Far from being an arrival point, this decision marked the beginning of an adventure characterized by a 6 orders of magnitude improvement in the uncertainty of realization of atomic frequency and time references. Ever progressing atomic frequency standards and time references derived from them are key resources for science and for society. We will describe how the unit of time is realized with a fractional accuracy approaching $10^{-16}$ and how it is delivered to users via the elaboration of the international atomic time. We will describe the tremendous progress of optical frequency metrology over the last 20~years which led to a novel generation of optical frequency standards with fractional uncertainties of $10^{-18}$. We will describe work toward a possible redefinition of the SI second based on such standards. We will describe existing and emerging applications of atomic frequency standards in science.
△ Less
Submitted 26 October, 2019;
originally announced October 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Lorentz-symmetry test at Planck-scale suppression with nucleons in a spin-polarized $^{133}$Cs cold atom clock
Authors:
H. Pihan-Le Bars,
C. Guerlin,
R. -D. Lasseri,
J. -P. Ebran,
Q. G. Bailey,
S. Bize,
E. Khan,
P. Wolf
Abstract:
We introduce an improved model that links the frequency shift of the $^{133}\text{Cs}$ hyperfine Zeeman transitions $\vert F = 3, m_F> \longleftrightarrow \vert F = 4, m_F >$ to the Lorentz-violating Standard-Model Extension (SME) coefficients of the proton and neutron. The new model uses Lorentz transformations developed to second order in boost and additionally takes the nuclear structure into a…
▽ More
We introduce an improved model that links the frequency shift of the $^{133}\text{Cs}$ hyperfine Zeeman transitions $\vert F = 3, m_F> \longleftrightarrow \vert F = 4, m_F >$ to the Lorentz-violating Standard-Model Extension (SME) coefficients of the proton and neutron. The new model uses Lorentz transformations developed to second order in boost and additionally takes the nuclear structure into account, beyond the simple Schmidt model used previously in SME analyses, thereby providing access to both proton and neutron SME coefficients including the isotropic coefficient $\tilde{c}_{TT}$. Using this new model in a second analysis of the data delivered by the FO2 dual Cs/Rb fountain at Paris Observatory and previously analysed in arXiv:hep-ph/0601024v1, we improve by up to 12 orders of magnitude the present maximum sensitivities (see arXiv:0801.0287v9) on the $\tilde{c}_{Q}$, $\tilde{c}_{TJ}$ and $\tilde{c}_{TT}$ coefficients for the neutron and on the $\tilde{c}_{TT}$ coefficient for the proton, reaching respectively $10^{-20}$, $10^{-17}$, $10^{-13}$ and $10^{-15}$ GeV.
△ Less
Submitted 31 May, 2017; v1 submitted 21 December, 2016;
originally announced December 2016.
-
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Authors:
Guillaume Lion,
Isabelle Panet,
Peter Wolf,
Christine Guerlin,
Sébastien Bize,
Pacôme Delva
Abstract:
Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-level accuracy in geoid height. However, so far detailed quantitative estimates of the possible improvement in geoid determination when adding such clock measurements to existing data are lacking. We present a first step…
▽ More
Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-level accuracy in geoid height. However, so far detailed quantitative estimates of the possible improvement in geoid determination when adding such clock measurements to existing data are lacking. We present a first step in that direction with the aim and hope of triggering further work and efforts in this emerging field of chronometric geodesy and geophysics. We specifically focus on evaluating the contribution of this new kind of direct measurements in determining the geopotential at high spatial resolution (~ 10 km). We studied two test areas, both located in France and corresponding to a middle (Massif Central) and high (Alps) mountainous terrain. These regions are interesting because the gravitational field strength varies greatly from place to place at high spatial resolution due to the complex topography. Our method consists in first generating a synthetic high resolution geopotential map, then drawing synthetic measurement data (gravimetry and clock data) from it, and finally reconstructing the geopotential map from that data using least squares collocation. The quality of the reconstructed map is then assessed by comparing it to the original one used to generate the data. We show that adding only a few clock data points (less than 1 % of the gravimetry data) reduces the bias significantly and improves the standard deviation by a factor 3. The effect of the data coverage and data quality on the results is investigated, and the trade-off between the measurement noise level and the number of data points is discussed.
△ Less
Submitted 19 January, 2017; v1 submitted 12 December, 2016;
originally announced December 2016.
-
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Authors:
Jérôme Lodewyck,
Sławomir Bilicki,
Eva Bookjans,
Jean-Luc Robyr,
Chunyan Shi,
Grégoire Vallet,
Rodolphe Le Targat,
Daniele Nicolodi,
Yann Le Coq,
Jocelyne Guéna,
Michel Abgrall,
Peter Rosenbusch,
Sébastien Bize
Abstract:
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached th…
▽ More
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude smaller than the best microwave clocks. For this reason, a redefinition of the SI second based on optical clocks seems possible in the near future. However, the operation of optical lattice clocks has not yet reached the reliability that microwave clocks have achieved so far. In this paper, we report on the operation of a strontium optical lattice clock that spans several weeks, with more than 80% uptime. We make use of this long integration time to demonstrate a reproducible measurement of frequency ratios between the strontium clock transition and microwave Cs primary and Rb secondary frequency standards.
△ Less
Submitted 12 May, 2016;
originally announced May 2016.
-
Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
Authors:
A. Hees,
J. Guéna,
M. Abgrall,
S. Bize,
P. Wolf
Abstract:
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine tr…
▽ More
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter candidate. Such a scalar field can induce harmonic variations of the fine structure constant, of the mass of fermions and of the quantum chromodynamic mass scale, which will directly impact the rubidium/caesium hyperfine transition frequency ratio. We find no signal consistent with a scalar dark matter candidate but provide improved constraints on the coupling of the putative scalar field to standard matter. Our limits are complementary to previous results that were only sensitive to the fine structure constant, and improve them by more than an order of magnitude when only a coupling to electromagnetism is assumed.
△ Less
Submitted 28 July, 2016; v1 submitted 28 April, 2016;
originally announced April 2016.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
S. Origlia,
S. Schiller,
M. S. Pramod,
L. Smith,
Y. Singh,
W. He,
S. Viswam,
D. Świerad,
J. Hughes,
K. Bongs,
U. Sterr,
Ch. Lisdat,
S. Vogt,
S. Bize,
J. Lodewyck,
R. Le Targat,
D. Holleville,
B. Venon,
P. Gill,
G. Barwood,
I. R. Hill,
Y. Ovchinnikov,
A. Kulosa,
W. Ertmer,
E. -M. Rasel
, et al. (3 additional authors not shown)
Abstract:
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than…
▽ More
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.
△ Less
Submitted 19 March, 2016;
originally announced March 2016.
-
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Authors:
R Tyumenev,
M Favier,
S Bilicki,
E Bookjans,
R Le Targat,
J Lodewyck,
D Nicolodi,
Y Le Coq,
M Abgrall,
J Guéna,
L De Sarlo,
S Bize
Abstract:
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (sta…
▽ More
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of $1.7\times 10^{-16}$. Comparing this characterized frequency standard to a Cs atomic fountain we determine the absolute frequency of the $^1S_0 \rightarrow \phantom{}^3P_0$ transition of $^{199}$Hg as $ν_{\mathrm{Hg}} = 1 128\,575\,290\,808\,154.62\,$Hz $\pm\,0.19\,$Hz (statistical) $\pm\,0.38\,$Hz (systematic), limited solely by the realization of the SI second. Furthermore, by comparing the mercury optical lattice clock to a Rb atomic fountain, we determine for the first time to our knowledge the ratio between the $^{199}$Hg clock transition and the $^{87}$Rb ground state hyperfine transition. Finally we present a direct optical to optical measurement of the $^{199}$Hg/$^{87}$Sr frequency ratio. The obtained value of $ν_{\mathrm{Hg}}/ν_{\mathrm{Sr}}=2.629\,314\,209\,898\,909\,15$ with a fractional uncertainty of $1.8\times10^{-16}$ is in excellent agreement with the same measurement obtained by Yamanaka et al. (arXiv:1503.07941). This makes this frequency ratio one of the few physical quantities agreed upon by different laboratories to this level of uncertainty. Frequency ratio measurements of the kind of those reported in this paper have a strong impact for frequency metrology but also for fundamental physics as they can be used to monitor putative variations of fundamental constants.
△ Less
Submitted 13 November, 2016; v1 submitted 7 March, 2016;
originally announced March 2016.
-
Atomic fountains and optical clocks at SYRTE: status and perspectives
Authors:
M. Abgrall,
B. Chupin,
L. De Sarlo,
J. Guéna,
Ph. Laurent,
Y. Le Coq,
R. Le Targat,
J. Lodewyck,
M. Lours,
P. Rosenbusch,
D. Rovera,
S. Bize
Abstract:
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on w…
▽ More
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application to timekeeping. We also cover the development of optical lattice clocks based on strontium and on mercury. We report on tests of fundamental physical laws made with these highly accurate atomic clocks. We also report on work relevant to a future possible redefinition of the SI second.
△ Less
Submitted 16 July, 2015;
originally announced July 2015.
-
Development of a strontium optical lattice clock for the SOC mission on the ISS
Authors:
K. Bongs,
Y. Singh,
L. Smith,
W. He,
O. Kock,
D. Swierad,
J. Hughes,
S. Schiller,
S. Alighanbari,
S. Origlia,
S. Vogt,
U. Sterr,
Ch. Lisdat,
R. Le Targat,
J. Lodewyck,
D. Holleville,
B. Venon,
S. Bize,
G. P. Barwood,
P. Gill,
I. R. Hill,
Y. B. Ovchinnikov,
N. Poli,
G. M. Tino,
J. Stuhler
, et al. (2 additional authors not shown)
Abstract:
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at l…
▽ More
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.
△ Less
Submitted 29 March, 2015;
originally announced March 2015.
-
Contributing to TAI with a Secondary Representation of the SI Second
Authors:
Jocelyne Guéna,
Michel Abgrall,
André Clairon,
Sébastien Bize
Abstract:
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in th…
▽ More
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain frequency standard using the $^{87}$Rb ground state hyperfine transition. We describe FO2-Rb and how it is connected to local and international time scales. We report on local measurements of this frequency standard in the SI system, i.e. against primary frequency standards, down to a fractional uncertainty of $4.4\times 10^{-16}$, and on the establishment of the recommended value for the $^{87}$Rb hyperfine transition by the CIPM. We also report on the process that led to the participation of the FO2-Rb frequency standard to $Circular~T$ and to the elaboration of TAI. This participation enables us to demonstrate absolute frequency measurement directly in terms of the SI second realized by the TAI ensemble with a statistical uncertainty of $1.1\times 10^{-16}$, therefore at the limit allowed by the accuracy of primary frequency standards. This work constitutes a demonstration of how other secondary representations, based on optical transitions, could also be used for TAI, and an investigation of a number of issues relevant to a future redefinition of the SI second.
△ Less
Submitted 29 January, 2014;
originally announced January 2014.
-
Experimenting an optical second with strontium lattice clocks
Authors:
R. Le Targat,
L. Lorini,
Y. Le Coq,
M. Zawada,
J. Guéna,
M. Abgrall,
M. Gurov,
P. Rosenbusch,
D. G. Rovera,
B. Nagórny,
R. Gartman,
P. G. Westergaard,
M. E. Tobar,
M. Lours,
G. Santarelli,
A. Clairon,
S. Bize,
P. Laurent,
P. Lemonde,
J. Lodewyck
Abstract:
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurat…
▽ More
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.
△ Less
Submitted 31 July, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
Authors:
J. Guéna,
P. Rosenbusch,
Ph. Laurent,
M. Abgrall,
D. Rovera,
M. Lours,
G. Santarelli,
M. E. Tobar,
S. Bize,
A. Clairon
Abstract:
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency meas…
▽ More
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual clock operation occurs with no degradation of either the stability or the accuracy. We describe the key features for achieving such a simultaneous operation. We also report on the results of the first Rb/Cs frequency measurement campaign performed with FO2 in this dual atom clock configuration, including a new determination of the absolute 87Rb hyperfine frequency.
△ Less
Submitted 3 January, 2013;
originally announced January 2013.
-
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
Authors:
S. Schiller,
A. Görlitz,
A. Nevsky,
S. Alighanbari,
S. Vasilyev,
C. Abou-Jaoudeh,
G. Mura,
T. Franzen,
U. Sterr,
S. Falke,
Ch. Lisdat,
E. Rasel,
A. Kulosa,
S. Bize,
J. Lodewyck,
G. M. Tino,
N. Poli,
M. Schioppo,
K. Bongs,
Y. Singh,
P. Gill,
G. Barwood,
Y. Ovchinnikov,
J. Stuhler,
W. Kaenders
, et al. (6 additional authors not shown)
Abstract:
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio…
▽ More
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.
△ Less
Submitted 17 June, 2012;
originally announced June 2012.
-
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Peter Rosenbusch,
Michael E. Tobar,
Philippe Laurent,
André Clairon,
Sébastien Bize
Abstract:
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H.…
▽ More
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.
△ Less
Submitted 22 August, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
Authors:
J. J. McFerran,
D. V. Magalhaes,
C. Mandache,
J. Millo,
W. Zhang,
Y. Le Coq,
G. Santarelli,
S. Bize
Abstract:
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.…
▽ More
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and achieve a fractional frequency stability of 5.4x10^(-15)/sqrt(tau) for tau<=400s. The highly stable laser light used for the atom probing is derived from a 1062.6 nm fiber laser locked to an ultrastable optical cavity that exhibits a mean drift rate of -6.0x10^(-17) s^(-1) (or -16.9 mHz.s^(-1) at 282 THz) over a five month period. A comparison between two such lasers locked to independent optical cavities shows a flicker noise limited fractional frequency instability of 4x10^(-16) per cavity.
△ Less
Submitted 2 July, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields
Authors:
D. J. Papoular,
S. Bize,
A. Clairon,
H. Marion,
S. J. Kokkelmans,
G. V. Shlyapnikov
Abstract:
We have observed Feshbach resonances for 133Cs atoms in two different hyperfine states at ultra-low static magnetic fields by using an atomic fountain clock. The extreme sensitivity of our setup allows for high signal-to-noise-ratio observations at densities of only 2*10^7 cm^{-3}. We have reproduced these resonances using coupled-channels calculations which are in excellent agreement with our mea…
▽ More
We have observed Feshbach resonances for 133Cs atoms in two different hyperfine states at ultra-low static magnetic fields by using an atomic fountain clock. The extreme sensitivity of our setup allows for high signal-to-noise-ratio observations at densities of only 2*10^7 cm^{-3}. We have reproduced these resonances using coupled-channels calculations which are in excellent agreement with our measurements. We justify that these are s-wave resonances involving weakly-bound states of the triplet molecular Hamiltonian, identify the resonant closed channels, and explain the observed multi-peak structure. We also describe a model which precisely accounts for the collisional processes in the fountain and which explains the asymmetric shape of the observed Feshbach resonances in the regime where the kinetic energy dominates over the coupling strength.
△ Less
Submitted 11 May, 2012;
originally announced May 2012.
-
Progress in Atomic Fountains at LNE-SYRTE
Authors:
Jocelyne Guéna,
Michel Abgrall,
Daniele Rovera,
Philippe Laurent,
Baptiste Chupin,
Michel Lours,
Giorgio Santarelli,
Peter Rosenbusch,
Michael E. Tobar,
Ruoxin Li,
Kurt Gibble,
André Clairon,
Sébastien Bize
Abstract:
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed…
▽ More
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
Authors:
J. J. McFerran,
L. Yi,
S. Mejri,
S. Di Manno,
W. Zhang,
J. Guéna,
Y. Le Coq,
S. Bize
Abstract:
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are load…
▽ More
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an atomic quality factor, Q, of ~10^(14). The 199Hg atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of 362.5697 +/-0.0011 nm and at a lattice depth of 20Er. The atoms are loaded from a single stage magneto-optical trap with cooling light at 253.7 nm. The high Q factor is obtained with an 80 ms Rabi pulse at 265.6 nm. The frequency of the clock transition is found to be 1 128 575 290 808 162.0 +/-6.4 (sys.) +/-0.3 (stat.) Hz (fractional uncertainty = 5.7x10^(-15)). Neither an atom number nor second order Zeeman dependence have yet to be detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing and detection.
△ Less
Submitted 17 January, 2012;
originally announced January 2012.
-
Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
Authors:
Jocelyne Guéna,
Ruoxin Li,
Kurt Gibble,
Sébastien Bize,
André Clairon
Abstract:
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10…
▽ More
We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.
△ Less
Submitted 8 March, 2011;
originally announced March 2011.
-
An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock
Authors:
S. T. Dawkins,
R. Chicireanu,
M. Petersen,
J. Millo,
D. V. Magalhães,
C. Mandache,
Y. Le Coq,
S. Bize
Abstract:
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low the…
▽ More
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-Pérot cavity which is highly impervious to temperature and vibrational perturbations. The mirror substrate is made of fused silica in order to exploit the comparatively low thermal noise limits associated with this material. By stabilizing the frequency of a 1062.6 nm Yb-doped fiber laser to the cavity, and including an additional link to LNE-SYRTE's fountain primary frequency standards via an optical frequency comb, we produce a signal which is both stable at the 1E-15 level in fractional terms and referenced to primary frequency standards. The signal is subsequently amplified and frequency-doubled twice to produce several milliwatts of interrogation signal at 265.6 nm in the deep ultraviolet.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Testing Local Lorentz and Position Invariance and Variation of Fundamental Constants by searching the Derivative of the Comparison Frequency Between a Cryogenic Sapphire Oscillator and Hydrogen Maser
Authors:
Michael Edmund Tobar,
Peter Wolf,
Sebastien Bize,
Giorgio Santarelli,
Victor Flambaum
Abstract:
The cryogenic sapphire oscillator (CSO) at the Paris Observatory has been continuously compared to various Hydrogen Masers since 2001. The early data sets were used to test Local Lorentz Invariance in the Robertson-Mansouri-Sexl (RMS) framework by searching for sidereal modulations with respect to the Cosmic Microwave Background, and represent the best Kennedy-Thorndike experiment to date. In th…
▽ More
The cryogenic sapphire oscillator (CSO) at the Paris Observatory has been continuously compared to various Hydrogen Masers since 2001. The early data sets were used to test Local Lorentz Invariance in the Robertson-Mansouri-Sexl (RMS) framework by searching for sidereal modulations with respect to the Cosmic Microwave Background, and represent the best Kennedy-Thorndike experiment to date. In this work we present continuous operation over a period of greater than six years from September 2002 to December 2008 and present a more precise way to analyze the data by searching the time derivative of the comparison frequency. Due to the long-term operation we are able to search both sidereal and annual modulations. The results gives P_{KT} = β_{RMS}-α_{RMS}-1 = -1.7(4.0) \times 10^{-8} for the sidereal and -23(10) \times 10^{-8} for the annual term, with a weighted mean of -4.8(3.7) \times 10^{-8}, a factor of 8 better than previous. Also, we analyze the data with respect to a change in gravitational potential for both diurnal and annual variations. The result gives β_{H-Maser} - β_{CSO} = -2.7(1.4) \times 10^{-4} for the annual and -6.9(4.0) \times 10^{-4} for the diurnal terms, with a weighted mean of -3.2(1.3) \times 10^{-4}. This result is two orders of magnitude better than other tests that use electromagnetic resonators. With respect to fundamental constants a limit can be provided on the variation with ambient gravitational potential and boost of a combination of the fine structure constant (α), the normalized quark mass (m_q), and the electron to proton mass ratio (m_e/m_p), setting the first limit on boost dependence of order 10^{-10}.
△ Less
Submitted 16 December, 2009; v1 submitted 15 December, 2009;
originally announced December 2009.
-
Ultrastable lasers based on vibration insensitive cavities
Authors:
J. Millo,
D. V. Magalhaes,
C. Mandache,
Y. Le Coq,
E. M. L. English,
P. G. Westergaard,
J. Lodewyck,
S. Bize,
P. Lemonde,
G. Santarelli
Abstract:
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better…
▽ More
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to decrease the thermal noise limit, in order to improve the frequency stability over previous designs. Vibration sensitivity components measured are equal to or better than 1.5e-11 per m.s^-2 for each spatial direction, which shows significant improvement over previous studies. We have tested the very low dependence on the position of the cavity support points, in order to establish that our designs eliminate the need for fine tuning to achieve extremely low vibration sensitivity. Relative frequency measurements show that at least one of the stabilized lasers has a stability better than 5.6e-16 at 1 second, which is the best result obtained for this length of cavity.
△ Less
Submitted 4 May, 2009; v1 submitted 29 January, 2009;
originally announced January 2009.
-
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
Authors:
J. Millo,
M. Abgrall,
M. Lours,
E. M. L. English,
H. Jiang,
J. Guena,
A. Clairon,
S. Bize,
Y. Le Coq,
G. Santarelli,
M. E. Tobar
Abstract:
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used t…
▽ More
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about $3\times10^{-15}$ between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of $3.5\times10^{-14}τ^{-1/2}$. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.
△ Less
Submitted 23 January, 2009;
originally announced January 2009.
-
Doppler-free spectroscopy of the 1S0-3P0 optical clock transition in laser-cooled fermionic isotopes of neutral mercury
Authors:
M. Petersen,
R. Chicireanu,
S. T. Dawkins,
D. V. Magalhães,
C. Mandache,
Y. Lecoq,
A. Clairon,
S. Bize
Abstract:
We have performed for the first time direct laser spectroscopy of the 1S0-3P0 optical clock transition at 265.6 nm in fermionic isotopes of neutral mercury laser-cooled in a magneto-optical trap. Spectroscopy is performed by measuring the depletion of the magneto-optical trap induced by the excitation of the long-lived 3P0 state by a probe at 265.6 nm. Measurements resolve the Doppler-free recoi…
▽ More
We have performed for the first time direct laser spectroscopy of the 1S0-3P0 optical clock transition at 265.6 nm in fermionic isotopes of neutral mercury laser-cooled in a magneto-optical trap. Spectroscopy is performed by measuring the depletion of the magneto-optical trap induced by the excitation of the long-lived 3P0 state by a probe at 265.6 nm. Measurements resolve the Doppler-free recoil doublet allowing for a determination of the transition frequency to an uncer- tainty well below the Doppler-broadened linewidth. We have performed absolute measurement of the frequency with respect to an ultra-stable reference monitored by LNE-SYRTE fountain pri- mary frequency standards using a femtosecond laser frequency comb. The measured frequency is 1128575290808 +/- 5.6 kHz in 199Hg and 1128569561140 +/- 5.3 kHz in 201Hg, more than 4 orders of magnitude better than previous indirect determinations. Owing to a low sensitivity to blackbody radiation, mercury is a promising candidate for reaching the ultimate performance of optical lattice clocks.
△ Less
Submitted 22 July, 2008;
originally announced July 2008.
-
An Optical Lattice Clock with Spin-polarized 87Sr Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Frédéric Chapelet,
Michel Abgrall,
Giovanni D. Rovera,
Philippe Laurent,
Peter Rosenbusch,
Sébastien Bize,
Giorgio Santarelli,
André Clairon,
Pierre Lemonde,
Gesine Grosche,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one o…
▽ More
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.
△ Less
Submitted 29 September, 2007;
originally announced October 2007.
-
Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Yann Le Coq,
Giovanni D. Rovera,
Sebastien Bize,
Pierre Lemonde
Abstract:
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss…
▽ More
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock frequency is determined to be 429 228 066 418 009(32) Hz. The isotopic shift between 87Sr and 88Sr is 62 188 135 Hz with fractional uncertainty 5.10^{-7}. We discuss the conditions necessary to reach a clock accuracy of 10^{-17} or less using this scheme.
△ Less
Submitted 14 March, 2007;
originally announced March 2007.
-
Long Term Operation and Performance of Cryogenic Sapphire Oscillators
Authors:
M. E. Tobar,
E. N. Ivanov,
C. R. Locke,
P. L. Stanwix,
J. G. Hartnett,
A. N. Luiten,
R. B. Warrington,
P. T. H. Fisk,
M. A. Lawn,
M. J. Wouters,
S. Bize,
G. Santarelli,
P. Wolf,
A. Clairon,
P. Guillemot
Abstract:
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive…
▽ More
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency standards at the limit of quantum projection noise; otherwise aliasing effects will dominate the frequency stability due to the periodic sampling between successive interrogations of the atomic transition. For this reason, UWA oscillators are now operational at NMI (Sydney), LNE-SYRTE (Paris), the French Space Agency (CNES, Toulouse) and at UWA (Perth). Other applications, which have attracted attention in recent years, include tests on fundamental principles of physics, such as tests of Lorentz invariance. This paper reports on the long-term operation and performance of such oscillators. We compare the long-term drift of some different CSOs. The drift rates turn out to be linear over many years and in the same direction. However, the magnitude seems to vary by more than one order of magnitude between the oscillators, ranging from 10^14 per day to a few parts in 10^13 per day.
△ Less
Submitted 19 August, 2006;
originally announced August 2006.
-
From Optical Lattice Clocks to the Measurement of Forces in the Casimir Regime
Authors:
Peter Wolf,
Pierre Lemonde,
Astrid Lambrecht,
Sebastien Bize,
Arnaud Landragin,
Andre Clairon
Abstract:
We describe a novel experiment based on atoms trapped close to a macroscopic surface, to study the interactions between the atoms and the surface at very small separations (0.6 to 10 $μ$m). In this range the dominant potential is the QED interaction (Casimir-Polder and Van der Waals) between the surface and the atom. Additionally, several theoretical models suggest the possibility of Yukawa type…
▽ More
We describe a novel experiment based on atoms trapped close to a macroscopic surface, to study the interactions between the atoms and the surface at very small separations (0.6 to 10 $μ$m). In this range the dominant potential is the QED interaction (Casimir-Polder and Van der Waals) between the surface and the atom. Additionally, several theoretical models suggest the possibility of Yukawa type potentials with sub-mm range, arising from new physics related to gravity. The proposes set-up is very similar to neutral atom optical lattice clocks, but with the atoms trapped in lattice sites close to the reflecting mirror. A sequence of pulses of the probe laser at different frequencies is then used to create an interferometer with a coherent superposition between atomic states at different distances from the mirror (in different lattice sites). Assuming atom interferometry state of the art measurement of the phase difference and a duration of the superposition of about 0.1 s we expect to be able to measure the potential difference between separated states with an uncertainty of $\approx 10^{-4}$ Hz. An analysis of systematic effects for different atoms and surfaces indicates no fundamentally limiting effect at the same level of uncertainty, but does influence the choice of atom and surface material. Based on those estimates, we expect that such an experiment would improve the best existing measurements of the atom-wall QED interaction by $\geq$ 2 orders of magnitude, whilst gaining up to 4 orders of magnitude on the best present limits on new interactions in the range between 100 nm and 100 $μ$m.
△ Less
Submitted 15 December, 2006; v1 submitted 2 August, 2006;
originally announced August 2006.
-
Interference-filter-stabilized external-cavity diode lasers
Authors:
X. Baillard,
A. Gauguet,
S. Bize,
P. Lemonde,
Ph. Laurent,
A. Clairon,
P. Rosenbusch
Abstract:
We have developed external-cavity diode lasers, where the wavelength selection is assured by a low loss interference filter instead of the common diffraction grating. The filter allows a linear cavity design reducing the sensitivity of the wavelength and the external cavity feedback against misalignment. By separating the feedback and wavelength selection functions, both can be optimized indepen…
▽ More
We have developed external-cavity diode lasers, where the wavelength selection is assured by a low loss interference filter instead of the common diffraction grating. The filter allows a linear cavity design reducing the sensitivity of the wavelength and the external cavity feedback against misalignment. By separating the feedback and wavelength selection functions, both can be optimized independently leading to an increased tunability of the laser. The design is employed for the generation of laser light at 698, 780 and 852 nm. Its characteristics make it a well suited candidate for space-born lasers.
△ Less
Submitted 5 May, 2006;
originally announced May 2006.
-
High Resolution Frequency Standard Dissemination via Optical Fibre Metropolitan Network
Authors:
Francois Narbonneau,
Michel Lours,
Olivier Lopez,
Anne Amy-Klein,
Christophe Daussy,
Christian Chardonnet,
Sebastien Bize,
Andre Clairon,
Giorgio Santarelli
Abstract:
We present in this paper results on a new dissemination system of ultra-stable reference signal at 100 MHz on a standard fibre network. The 100 MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solution suggested in…
▽ More
We present in this paper results on a new dissemination system of ultra-stable reference signal at 100 MHz on a standard fibre network. The 100 MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solution suggested in order to improve the frequency stability and to further extend the distribution distance. Nevertheless, our system is a good tool for the best cold atom fountains comparison between laboratories, up to 100 km, with a relative frequency resolution of 10-14 at one second integration time and 10-17 for one day of measurement. The distribution system may be upgraded to fulfill the stringent distribution requirements for the future optical clocks.
△ Less
Submitted 15 March, 2006;
originally announced March 2006.
-
Cold Atom Clock Test of Lorentz Invariance in the Matter Sector
Authors:
Peter Wolf,
Frederic Chapelet,
Sebastien Bize,
Andre Clairon
Abstract:
We report on a new experiment that tests for a violation of Lorentz invariance (LI), by searching for a dependence of atomic transition frequencies on the orientation of the spin of the involved states (Hughes-Drever type experiment). The atomic frequencies are measured using a laser cooled $^{133}$Cs atomic fountain clock, operating on a particular combination of Zeeman substates. We analyze th…
▽ More
We report on a new experiment that tests for a violation of Lorentz invariance (LI), by searching for a dependence of atomic transition frequencies on the orientation of the spin of the involved states (Hughes-Drever type experiment). The atomic frequencies are measured using a laser cooled $^{133}$Cs atomic fountain clock, operating on a particular combination of Zeeman substates. We analyze the results within the framework of the Lorentz violating standard model extension (SME), where our experiment is sensitive to a largely unexplored region of the SME parameter space, corresponding to first measurements of four proton parameters and improvements by 11 and 13 orders of magnitude on the determination of four others. In spite of the attained uncertainties, and of having extended the search into a new region of the SME, we still find no indication of LI violation.
△ Less
Submitted 4 January, 2006;
originally announced January 2006.
-
Recent Experimental Tests of Special Relativity
Authors:
Peter Wolf,
Sebastien Bize,
Michael E. Tobar,
Frederic Chapelet,
Andre Clairon,
Andre N. Luiten,
Giorgio Santarelli
Abstract:
We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative…
▽ More
We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative theories to special relativity. We also report first results of a test of Lorentz invariance in the SME (Standard Model Extension) matter sector, using Zeeman transitions in a laser cooled Cs atomic fountain clock. We describe the experiment together with the theoretical model and analysis. Recent experimental results are presented and we give a first estimate of components of the $\tilde{c}^p$ parameters of the SME matter sector. A full analysis of systematic effects is still in progress, and will be the subject of a future publication together with our final results. If confirmed, the present limits would correspond to first ever measurements of some $\tilde{c}^p$ components, and improvements by 11 and 14 orders of magnitude on others.
△ Less
Submitted 21 June, 2005;
originally announced June 2005.
-
Cold atom Clocks and Applications
Authors:
S. Bize,
P. Laurent,
M. Abgrall,
H. Marion,
I. Maksimovic,
L. Cacciapuoti,
J. Gruenert,
C. Vian,
F. Pereira dos Santos,
P. Rosenbusch,
P. Lemonde,
G. Santarelli,
P. Wolf,
A. Clairon,
A. Luiten,
M. Tobar,
C. Salomon
Abstract:
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time…
▽ More
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of $2\times 10^{-16}$ at $50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of $7\times 10^{-16}$, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using $^{87}$Rb and $^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.
-
First observation of feshbach resonances at very low magnetic field in a 133Cs fountain
Authors:
H. Marion,
S. Bize,
L. Cacciapuoti,
D. Chambon,
F. Pereira Dos Santos,
G. Santarelli,
P. Wolf,
A. Clairon,
A. Luiten,
M. Tobar,
S. Kokkelmans,
C. Salomon
Abstract:
One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the…
▽ More
One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the clock shift as a function of the field has been performed. Feshbach resonances have been observed for the first time at very low magnetic field and with a very good resolution. A Monte Carlo simulation has been performed and could fit properly some of experimental data. This constrains some parameters of the theory of collisions.
△ Less
Submitted 7 August, 2006; v1 submitted 13 July, 2004;
originally announced July 2004.
-
New Limits to the Drift of Fundamental Constants from Laboratory Measurements
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Haensch,
M. Abgrall,
J. Gruenert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon,
M. Haas,
U. D. Jentschura,
C. H. Keitel
Abstract:
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency…
▽ More
We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency in $^{199}$Hg$^+$ against $ν_{\rm {Cs}}$ and a microwave $^{87}$Rb and $^{133}$Cs clock comparison, we deduce separate limits on $\dotα/α= (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments $μ_{\rm {Rb}}/μ_{\rm {Cs}}$ equal to $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$. The latter provides information on the temporal behavior of the constant of strong interaction.
△ Less
Submitted 4 June, 2004; v1 submitted 12 December, 2003;
originally announced December 2003.
-
Precision Spectroscopy of Atomic Hydrogen and Variations of Fundamental Constants
Authors:
M. Fischer,
N. Kolachevsky,
M. Zimmermann,
R. Holzwarth,
Th. Udem,
T. W. Hänsch,
M. Abgrall,
J. Grünert,
I. Maksimovic,
S. Bize,
H. Marion,
F. Pereira Dos Santos,
P. Lemonde,
G. Santarelli,
P. Laurent,
A. Clairon,
C. Salomon
Abstract:
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measure…
▽ More
In 2003 we have measured the absolute frequency of the $(1S, F=1, m_F=\pm 1) \leftrightarrow (2S, F'=1, m_F'=\pm 1)$ two-photon transition in atomic hydrogen. We observed a variation of $(-29\pm 57)$ Hz over a 44 months interval separating this measurement from the previous one performed in 1999. We have combined this result with recently published results of optical transition frequency measurement in the $^{199}$Hg$^+$ ion and and comparison between clocks based on $^{87}$Rb and $^{133}$Cs. From this combination we deduce the stringent limits for fractional time variation of the fine structure constant $\partial/{\partial t}(\ln α)=(-0.9\pm 4.2)\times 10^{-15}$ yr$^{-1}$ and for the ratio of $^{87}$Rb and $^{133}$Cs spin magnetic moments $\partial/{\partial t}(\ln[μ_{\rm {Rb}}/μ_{\rm {Cs}}])=(0.5\pm 2.1)\times 10^{-15}$ yr$^{-1}$. This is the first precise restriction for the fractional time variation of $α$ made without assumptions about the relative drifts of the constants of electromagnetic, strong and weak interactions.
△ Less
Submitted 27 July, 2004; v1 submitted 26 November, 2003;
originally announced November 2003.
-
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Authors:
H. Marion,
F. Pereira Dos Santos,
M. Abgrall,
S. Zhang,
Y. Sortais,
S. Bize,
I. Maksimovic,
D. Calonico,
J. Gruenert,
C. Mandache,
P. Lemonde,
G. Santarelli,
Ph. Laurent,
A. Clairon,
C. Salomon
Abstract:
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma…
▽ More
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.
△ Less
Submitted 31 December, 2002;
originally announced December 2002.
-
Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock
Authors:
S. Bize,
S. A. Diddams,
U. Tanaka,
C. E. Tanner,
W. H. Oskay,
R. E. Drullinger,
T. E. Parker,
T. P. Heavner,
S. R. Jefferts,
L. Hollberg,
W. M. Itano,
D. J. Wineland,
J. C. Bergquist
Abstract:
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertai…
▽ More
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs) m_e / m_p alpha^6.0 at the same level.
△ Less
Submitted 30 December, 2002;
originally announced December 2002.
-
133Cs87Rb Laser Cooled Dual Fountain
Authors:
D. Calonico,
Y. Sortais,
S. Bize,
H. Marion,
C. Mandache,
C. Salomon,
G. Santarelli,
A. Clairon
Abstract:
At BNM-SYRTE laboratories in Paris two 133Cs fountains and a 87Rb one have been already demonstrated. This paper illustrates the construction of a 87Rb and Cs dual fountain realized within the same structure to work simultaneously. Up to now only the Cs part is under operation but Rb part, already completed, will be soon operational. The experiment has been projected to improve present fountain…
▽ More
At BNM-SYRTE laboratories in Paris two 133Cs fountains and a 87Rb one have been already demonstrated. This paper illustrates the construction of a 87Rb and Cs dual fountain realized within the same structure to work simultaneously. Up to now only the Cs part is under operation but Rb part, already completed, will be soon operational. The experiment has been projected to improve present fountain frequency standards and to perform a more precise laboratory test (at 10E-16 level) on a possible time variation of the fine structure constant alpha, as recent cosmological evidences strongly motivates.
△ Less
Submitted 10 December, 2002;
originally announced December 2002.
-
Controlling the cold collision shift in high precision atomic interferometry
Authors:
F. Pereira Dos Santos,
H. Marion,
S. Bize,
Y. Sortais,
A. Clairon,
C. Salomon
Abstract:
We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the…
▽ More
We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the $10^{-16}$ level realistic. With an improved set-up, the adiabatic passage would allow measurements of atom number-dependent phase shifts at the $10^{-3}$ level in high precision experiments.
△ Less
Submitted 3 September, 2002;
originally announced September 2002.