Advanced LIGO detector performance in the fourth observing run
Authors:
E. Capote,
W. Jia,
N. Aritomi,
M. Nakano,
V. Xu,
R. Abbott,
I. Abouelfettouh,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
S. K. Apple,
K. Arai,
S. M. Aston,
M. Ball,
S. W. Ballmer,
D. Barker,
L. Barsotti,
B. K. Berger,
J. Betzwieser,
D. Bhattacharjee,
G. Billingsley,
S. Biscans,
C. D. Blair,
N. Bode,
E. Bonilla
, et al. (171 additional authors not shown)
Abstract:
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron st…
▽ More
On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.
△ Less
Submitted 21 November, 2024;
originally announced November 2024.
-
Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit
Authors:
Wenxuan Jia,
Victoria Xu,
Kevin Kuns,
Masayuki Nakano,
Lisa Barsotti,
Matthew Evans,
Nergis Mavalvala,
Rich Abbott,
Ibrahim Abouelfettouh,
Rana Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Naoki Aritomi,
Stuart Aston,
Matthew Ball,
Stefan Ballmer,
David Barker,
Beverly Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Nina Bode,
Edgard Bonilla,
Vladimir Bossilkov
, et al. (146 additional authors not shown)
Abstract:
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Stan…
▽ More
Precision measurements of space and time, like those made by the detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO), are often confronted with fundamental limitations imposed by quantum mechanics. The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot both be precisely measured, giving rise to an apparent limitation called the Standard Quantum Limit (SQL). Reducing quantum noise below the SQL in gravitational-wave detectors, where photons are used to continuously measure the positions of freely falling mirrors, has been an active area of research for decades. Here we show how the LIGO A+ upgrade reduced the detectors' quantum noise below the SQL by up to 3 dB while achieving a broadband sensitivity improvement, more than two decades after this possibility was first presented.
△ Less
Submitted 16 October, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Fiducial displacements with improved accuracy for the global network of gravitational wave detectors
Authors:
D Bhattacharjee,
Y Lecoeuche,
S Karki,
J Betzwieser,
V Bossilkov,
S Kandhasamy,
E Payne,
R L Savage
Abstract:
As sensitivities improve and more detectors are added to the global network of gravitational wave observatories, calibration accuracy and precision are becoming increasingly important. Photon calibrators, relying on power-modulated auxiliary laser beams reflecting from suspended interferometer optics, enable continuous calibration by generating displacement fiducials proportional to the modulated…
▽ More
As sensitivities improve and more detectors are added to the global network of gravitational wave observatories, calibration accuracy and precision are becoming increasingly important. Photon calibrators, relying on power-modulated auxiliary laser beams reflecting from suspended interferometer optics, enable continuous calibration by generating displacement fiducials proportional to the modulated laser power. Developments in the propagation of laser power calibration via transfer standards to on-line power sensors monitoring the modulated laser power have enabled generation of length fiducials with improved accuracy. Estimated uncertainties are almost a factor of two smaller than the lowest values previously reported. This is partly due to improvements in methodology that have increased confidence in the results reported. Referencing the laser power calibration standards for each observatory to a single transfer standard enables reducing relative calibration errors between elements of the detector network. Efforts within the national metrology institute community to realize improved laser power sensor calibration accuracy are ongoing.
△ Less
Submitted 29 May, 2020;
originally announced June 2020.
-
advligorts: The Advanced LIGO Real-Time Digital Control and Data Acquisition System
Authors:
Rolf Bork,
Jonathan Hanks,
David Barker,
Joseph Betzwieser,
Jameson Rollins,
Keith Thorne,
Erik von Reis
Abstract:
The Advanced LIGO detectors are sophisticated opto-mechanical devices. At the core of their operation is feedback control. The Advanced LIGO project developed a custom digital control and data acquisition system to handle the unique needs of this new breed of astronomical detector. The advligorts is the software component of this system. This highly modular and extensible system has enabled the un…
▽ More
The Advanced LIGO detectors are sophisticated opto-mechanical devices. At the core of their operation is feedback control. The Advanced LIGO project developed a custom digital control and data acquisition system to handle the unique needs of this new breed of astronomical detector. The advligorts is the software component of this system. This highly modular and extensible system has enabled the unprecedented performance of the LIGO instruments, and has been a vital component in the direct detection of gravitational waves.
△ Less
Submitted 4 May, 2020; v1 submitted 1 May, 2020;
originally announced May 2020.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
First Demonstration of Electrostatic Damping of Parametric Instability at Advanced LIGO
Authors:
Carl Blair,
Slawek Gras,
Richard Abbott,
Stuart Aston,
Joseph Betzwieser,
David Blair,
Ryan DeRosa,
Matthew Evans,
Valera Frolov,
Peter Fritschel,
Hartmut Grote,
Terra Hardwick,
Jian Liu,
Marc Lormand,
John Miller,
Adam Mullavey,
Brian O'Reilly,
Chunnong Zhao,
LSC Instrument Authors
Abstract:
Interferometric gravitational wave detectors operate with high optical power in their arms in order to achieve high shot-noise limited strain sensitivity. A significant limitation to increasing the optical power is the phenomenon of three-mode parametric instabilities, in which the laser field in the arm cavities is scattered into higher order optical modes by acoustic modes of the cavity mirrors.…
▽ More
Interferometric gravitational wave detectors operate with high optical power in their arms in order to achieve high shot-noise limited strain sensitivity. A significant limitation to increasing the optical power is the phenomenon of three-mode parametric instabilities, in which the laser field in the arm cavities is scattered into higher order optical modes by acoustic modes of the cavity mirrors. The optical modes can further drive the acoustic modes via radiation pressure, potentially producing an exponential buildup. One proposed technique to stabilize parametric instability is active damping of acoustic modes. We report here the first demonstration of damping a parametrically unstable mode using active feedback forces on the cavity mirror. A 15,538 Hz mode that grew exponentially with a time constant of 182 sec was damped using electro-static actuation, with a resulting decay time constant of 23 sec. An average control force of 0.03 nNrms was required to maintain the acoustic mode at its minimum amplitude.
△ Less
Submitted 28 November, 2016;
originally announced November 2016.
-
The Advanced LIGO Photon Calibrators
Authors:
S. Karki,
D. Tuyenbayev,
S. Kandhasamy,
B. P. Abbott,
T. D. Abbott,
E. H. Anders,
J. Berliner,
J. Betzwieser,
H. P. Daveloza,
C. Cahillane,
L. Canete,
C. Conley,
J. R. Gleason,
E. Goetz,
J. S. Kissel,
K. Izumi,
G. Mendell,
V. Quetschke,
M. Rodruck,
S. Sachdev,
T. Sadecki,
P. B. Schwinberg,
A. Sottile,
M. Wade,
A. J. Weinstein
, et al. (2 additional authors not shown)
Abstract:
The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generati…
▽ More
The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as Photon Calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO Photon Calibrators that are currently providing fiducial displacements on the order of $10^{-18}$ m/$\sqrt{\textrm{Hz}}$ with accuracy and precision of better than 1 %.
△ Less
Submitted 17 August, 2016;
originally announced August 2016.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Multi-color Cavity Metrology
Authors:
Kiwamu Izumi,
Koji Arai,
Bryan Barr,
Joseph Betzwieser,
Aidan Brooks,
Katrin Dahl,
Suresh Doravari,
Jennifer C. Driggers,
W. Zach Korth,
Haixing Miao,
Jameson Rollins,
Stephen Vass,
David Yeaton-Massey,
Rana X. Adhikari
Abstract:
Long baseline laser interferometers used for gravitational wave detection have proven to be very complicated to control. In order to have sufficient sensitivity to astrophysical gravitational waves, a set of multiple coupled optical cavities comprising the interferometer must be brought into resonance with the laser field. A set of multi-input, multi-output servos then lock these cavities into pla…
▽ More
Long baseline laser interferometers used for gravitational wave detection have proven to be very complicated to control. In order to have sufficient sensitivity to astrophysical gravitational waves, a set of multiple coupled optical cavities comprising the interferometer must be brought into resonance with the laser field. A set of multi-input, multi-output servos then lock these cavities into place via feedback control. This procedure, known as lock acquisition, has proven to be a vexing problem and has reduced greatly the reliability and duty factor of the past generation of laser interferometers. In this article, we describe a technique for bringing the interferometer from an uncontrolled state into resonance by using harmonically related external fields to provide a deterministic hierarchical control. This technique reduces the effect of the external seismic disturbances by four orders of magnitude and promises to greatly enhance the stability and reliability of the current generation of gravitational wave detector. The possibility for using multi-color techniques to overcome current quantum and thermal noise limits is also discussed.
△ Less
Submitted 24 May, 2012; v1 submitted 6 May, 2012;
originally announced May 2012.