Development and operational experience of magnetic horn system for T2K experiment
Authors:
T. Sekiguchi,
K. Bessho,
Y. Fujii,
M. Hagiwara,
T. Hasegawa,
K. Hayashi,
T. Ishida,
T. Ishii,
H. Kobayashi,
T. Kobayashi,
S. Koike,
K. Koseki,
T. Maruyama,
H. Matsumoto,
T. Nakadaira,
K. Nakamura,
K. Nakayoshi,
K. Nishikawa,
Y. Oyama,
K. Sakashita,
M. Shibata,
Y. Suzuki,
M. Tada,
K. Takahashi,
T. Tsukamoto
, et al. (12 additional authors not shown)
Abstract:
A magnetic horn system to be operated at a pulsed current of 320 kA and to survive high-power proton beam operation at 750 kW was developed for the T2K experiment. The first set of T2K magnetic horns was operated for over 12 million pulses during the four years of operation from 2010 to 2013, under a maximum beam power of 230 kW, and $6.63\times10^{20}$ protons were exposed to the production targe…
▽ More
A magnetic horn system to be operated at a pulsed current of 320 kA and to survive high-power proton beam operation at 750 kW was developed for the T2K experiment. The first set of T2K magnetic horns was operated for over 12 million pulses during the four years of operation from 2010 to 2013, under a maximum beam power of 230 kW, and $6.63\times10^{20}$ protons were exposed to the production target. No significant damage was observed throughout this period. This successful operation of the T2K magnetic horns led to the discovery of the $ν_μ\rightarrowν_e$ oscillation phenomenon in 2013 by the T2K experiment. In this paper, details of the design, construction, and operation experience of the T2K magnetic horns are described.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
Radionuclides in the Cooling Water Systems for the NuMi Beamline and the Antiproton Production Target Station at Fermilab
Authors:
Hiroshi Matsumura,
Akihiro Toyoda,
Kotaro Bessho,
Shun Sekimoto,
Hiroshi Yashima,
Yoshimi Kasugai,
Norihiro Matsuda,
Yukio Sakamoto,
Hiroshi Nakashima,
Koji Oishi,
David Boehnlein,
Gary Lauten,
Anthony Leveling,
Nikolai Mokhov,
Kamran Vaziri
Abstract:
At the 120-GeV proton accelerator facilities of Fermilab, USA, water samples were collected from the cooling water systems for the target, magnetic horn1, magnetic horn2, decay pipe, and hadron absorber at the NuMI beamline as well as from the cooling water systems for the collection lens, pulse magnet and collimator, and beam absorber at the antiproton production target station, just after the sh…
▽ More
At the 120-GeV proton accelerator facilities of Fermilab, USA, water samples were collected from the cooling water systems for the target, magnetic horn1, magnetic horn2, decay pipe, and hadron absorber at the NuMI beamline as well as from the cooling water systems for the collection lens, pulse magnet and collimator, and beam absorber at the antiproton production target station, just after the shutdown of the accelerators for a maintenance period. Specific activities of γ -emitting radionuclides and 3H in these samples were determined using high-purity germanium detectors and a liquid scintillation counter. The cooling water contained various radionuclides depending on both major and minor materials in contact with the water. The activity of the radionuclides depended on the presence of a deionizer. Specific activities of 3H were used to estimate the residual rates of 7Be. The estimated residual rates of 7Be in the cooling water were approximately 5% for systems without deionizers and less than 0.1% for systems with deionizers, although the deionizers function to remove 7Be from the cooling water.
△ Less
Submitted 29 August, 2014;
originally announced September 2014.