-
Comparison of Two Detector Magnetic Systems for the Future Circular Hadron-Hadron Collider
Authors:
Vyacheslav Klyukhin,
Austin Ball,
Christophe Paul Berriaud,
Benoit Curé,
Alexey Dudarev,
Andrea Gaddi,
Hubert Gerwig,
Alain Hervé,
Matthias Mentink,
Werner Riegler,
Udo Wagner,
Herman Ten Kate
Abstract:
The conceptual design study of a Future Circular hadron-hadron Collider (FCC-hh) to be con-structed at CERN with a center-of-mass energy of the order of 100 TeV requires superconducting magnetic systems with a central magnetic flux density of an order of 4 T for the experimental detectors. The developed concept of the FCC-hh detector involves the use of an iron-free magnetic system consisting of t…
▽ More
The conceptual design study of a Future Circular hadron-hadron Collider (FCC-hh) to be con-structed at CERN with a center-of-mass energy of the order of 100 TeV requires superconducting magnetic systems with a central magnetic flux density of an order of 4 T for the experimental detectors. The developed concept of the FCC-hh detector involves the use of an iron-free magnetic system consisting of three superconducting solenoids. A superconducting magnet with a minimal steel yoke is proposed as an alternative to the baseline iron-free design. In this study, both magnetic system options for the FCC-hh detector are modeled with the same electrical parameters using Cobham$'$s program TOSCA. All the main characteristics of both designs are compared and discussed.
△ Less
Submitted 5 January, 2024;
originally announced January 2024.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Comparison of the Baseline and the Minimal Steel Yoke Superconducting Magnets for the Future Circular Hadron-Hadron Collider
Authors:
V. I. Klyukhin,
A. Ball,
C. P. Berriaud,
E. Bielert,
B. Curé,
A. Dudarev,
A. Gaddi,
H. Gerwig,
A. Hervé,
M. Mentink,
H. Pais Da Silva,
U. Wagner,
H. H. J. Ten Kate
Abstract:
The conceptual design study of a hadron Future Circular hadron-hadron Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV assumes using in the experimental detector the superconducting magnetic system with a central magnetic flux density of an order of 4 T. A superconducting magnet with a minimal steel yoke was proposed as an alternative to the baseline iron-free solenoids. In a…
▽ More
The conceptual design study of a hadron Future Circular hadron-hadron Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV assumes using in the experimental detector the superconducting magnetic system with a central magnetic flux density of an order of 4 T. A superconducting magnet with a minimal steel yoke was proposed as an alternative to the baseline iron-free solenoids. In a present study, both designs are modeled with Cobham's program TOSCA and compared. All the main parameters are discussed.
△ Less
Submitted 18 January, 2022;
originally announced January 2022.
-
Superconducting Magnet with a Minimal Steel Yoke for the Future Circular Collider Detector
Authors:
V. I. Klyukhin,
A. Hervé,
A. Ball,
B. Curé,
A. Dudarev,
A. Gaddi,
H. Gerwig,
M. Mentink,
H. Pais Da Silva,
G. Rolando,
H. H. J. Ten Kate,
C. P. Berriaud
Abstract:
The conceptual design study of a Future Circular hadron-hadron Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV, assumed to be constructed in a new tunnel of 80-100 km circumference, includes the determination of the basic requirements for its detectors. A superconducting solenoid magnet of 12-m-diameter inner bore with the central magnetic flux density of 6 T, in combination…
▽ More
The conceptual design study of a Future Circular hadron-hadron Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV, assumed to be constructed in a new tunnel of 80-100 km circumference, includes the determination of the basic requirements for its detectors. A superconducting solenoid magnet of 12-m-diameter inner bore with the central magnetic flux density of 6 T, in combination with two superconducting dipole magnets and two conventional toroid magnets is proposed for an FCC-hh experimental setup. The coil of 23.468 m length has seven 3.35-m-long modules included into one cryostat. The steel yoke with a mass of 22.6 kt consists of two barrel layers of 0.5 m radial thickness and a 0.7-m-thick nose disk and four 0.6-m-thick end-cap disks each side. The outer diameter of the yoke is 17.7 m. The full length of the magnetic system is 62.6 m. The air gaps between the end-cap disks provide for the installation of the muon chambers up to an absolute pseudorapidity about 2.7. The superconducting dipole magnets provide measurement of charged particle momenta in the absolute pseudorapidity region greater than 3. The conventional forward muon spectrometer allows muon identification in the absolute pseudorapidity region from 2.7 to 5. The magnet is modeled with the program TOSCA from Cobham CTS Limited. The total current in the superconducting solenoid coil is 123 MA-turns; the stored energy is 41.8 GJ. The axial force acting on each end-cap is 450 MN. The stray field is 13.7 mT at a radius of 50 m from the coil axis, and 5.2 mT at a radius of 100 m. Many other parameters are presented and discussed.
△ Less
Submitted 8 August, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
Wide Aperture Vector magnet for neutron scattering studies
Authors:
P. Lavie,
A. M. Bataille,
A. Peugeot,
P. Bredy,
C. Berriaud,
A. Daël,
J. -M. Riffet,
S. Klimko,
J. -L. Meuriot,
T. Robillard,
G. Aubert
Abstract:
We propose an innovative design for a vector magnet compatible with neutron scattering experiments. This would vastly expand the range of experimental possibilities since applying a magnetic field and orienting the sample in diffraction conditions will become completely independent. This Wide Aperture VEctor magnet is a setup made of 16 coils, all with a vertical axis. The vertical component of th…
▽ More
We propose an innovative design for a vector magnet compatible with neutron scattering experiments. This would vastly expand the range of experimental possibilities since applying a magnetic field and orienting the sample in diffraction conditions will become completely independent. This Wide Aperture VEctor magnet is a setup made of 16 coils, all with a vertical axis. The vertical component of the field is produced by two pairs of coaxial coils carrying opposite currents for an active shielding of the stray field, while the horizontal components are generated by 3 sets of 4 coils each, two above and two below the diffraction plane. This innovative geometry allows a very wide aperture (220$\,^{\circ}$ horizontal, $\pm$ 10$\,^{\circ}$ vertical), which is crucial for neutron diffraction and inelastic neutron scattering experiments. Moreover, the homogeneity of the field is far better than in the usual vertical coils, and the diameter of the sample bore is unusually large (10 cm).
The concept has been developed so as to be used as a sample environment on every LLB instrument relevant for magnetism studies.
△ Less
Submitted 27 April, 2016;
originally announced April 2016.
-
Superconducting Magnet with the Reduced Barrel Yoke for the Hadron Future Circular Collider
Authors:
V. I. Klyukhin,
A. Ball,
C. Berriaud,
B. Curé,
A. Dudarev,
A. Gaddi,
H. Gerwig,
A. Hervé,
M. Mentink,
G. Rolando,
H. F. Pais Da Silva,
U. Wagner,
H. H. J. ten Kate
Abstract:
The conceptual design study of a hadron Future Circular Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV in a new tunnel of 80-100 km circumference assumes the determination of the basic requirements for its detectors. A superconducting solenoid magnet of 12 m diameter inner bore with the central magnetic flux density of 6 T is proposed for a FCC-hh experimental setup. The co…
▽ More
The conceptual design study of a hadron Future Circular Collider (FCC-hh) with a center-of-mass energy of the order of 100 TeV in a new tunnel of 80-100 km circumference assumes the determination of the basic requirements for its detectors. A superconducting solenoid magnet of 12 m diameter inner bore with the central magnetic flux density of 6 T is proposed for a FCC-hh experimental setup. The coil of 24.518 m long has seven 3.5 m long modules included into one cryostat. The steel yoke with a mass of 21 kt consists of two barrel layers of 0.5 m radial thickness, and 0.7 m thick nose disk, four 0.6 m thick end-cap disks, and three 0.8 m thick muon toroid disks each side. The outer diameter of the yoke is 17.7 m; the length without the forward muon toroids is 33 m. The air gaps between the end-cap disks provide the installation of the muon chambers up to the pseudorapidity of \pm 3.5. The conventional forward muon spectrometer provides the measuring of the muon momenta in the pseudorapidity region from \pm 2.7 to \pm 4.6. The magnet modeled with Cobham's program TOSCA. The total Ampere-turns in the superconducting solenoid coil are 127.25 MA-turns. The stored energy is 43.3 GJ. The axial force onto each end-cap is 480 MN. The stray field at the radius of 50 m off the coil axis is 14.1 mT and 5.4 mT at the radius of 100 m. All other parameters presented and discussed.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.