The ILD Detector: A Versatile Detector for an Electron-Positron Collider at Energies up to 1 TeV
Authors:
H. Abramowicz,
D. Ahmadi,
J. Alcaraz,
O. Alonso,
L. Andricek,
J. Anguiano,
O. Arquero,
F. Arteche,
D. Attie,
O. Bach,
M. Basso,
J. Baudot,
A. Bean,
T. Behnke,
A. Bellerive,
Y. Benhammou,
M. Berggren,
G. Bertolone,
M. Besancon,
A. Besson,
O. Bezshyyko,
G. Blazey,
B. Bliewert,
J. Bonis,
R. Bosley
, et al. (254 additional authors not shown)
Abstract:
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magneti…
▽ More
The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a central solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. ILD is based mostly on technologies which have been demonstrated by extensive research and test programs. The ILD concept is proposed both for linear and circular lepton collider, be it at CERN or elsewhere. The concept has been developed by a group of nearly 60 institutes from around the world, and offers a well developed and powerful environment for science and technology studies at lepton colliders. In this document, the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed.
△ Less
Submitted 6 June, 2025;
originally announced June 2025.
-
Atmospheric muon flux suppression at potential new low-radiation underground physics laboratory in Israel
Authors:
Nadav Hargittai,
Igor Zolkin,
Yiftah Silver,
Yan Benhammou,
Gilad Mizrachi,
Hagar Landsman,
Erez Etzion,
Ran Budnik
Abstract:
The residual atmospheric muon flux was measured at a candidate site for a new underground, low-radiation physics laboratory beneath the Kokhav HaYarden national park in Israel. Located inside the tunnels of a hydroelectric pumped-storage facility operating since 2024, the proposed site benefits from a vertical rock overburden of 361 meters, large potential floorspace, and easy access by road. A mu…
▽ More
The residual atmospheric muon flux was measured at a candidate site for a new underground, low-radiation physics laboratory beneath the Kokhav HaYarden national park in Israel. Located inside the tunnels of a hydroelectric pumped-storage facility operating since 2024, the proposed site benefits from a vertical rock overburden of 361 meters, large potential floorspace, and easy access by road. A muon hodoscope of vertically stacked wide-area $144 \times 60 \times 1.2 $ cm$^3$ plastic scintillator plates was employed to measure the suppression in the integrated muon flux at the site as compared with above ground at sea level. Data-taking took place in mid-August of 2024 for several days and was split into South-North and West-East orientations to account for the directional acceptances due to the geometry of the detector. The suppression factor is reported at $4456 \pm 77$, expressed as $3.75 \pm 0.06 \times 10^{-6}$ cm$^{-2}$ s$^{-1}$ in absolute terms, corresponding to an effective overburden of roughly $873$ m.w.e.. A deeper location at the site may also be available, but it could not be reached at this time. Furthermore, the asymmetric topography of the mountain above and its muon shadow are clearly visible in the angular data. Finally, auxiliary environmental measurements recorded low background radon activity at $28.3 \pm 14.0$ Bq m$^{-3}$. The experimental campaign thus succeeded in demonstrating the viability of the site's working conditions for future scientific research.
△ Less
Submitted 21 April, 2025;
originally announced April 2025.
-
First Demonstration of Underground Muon Imaging at an Archaeological Site in Ancient Jerusalem
Authors:
Yan Benhammou,
Erez Etzion,
Yuval Gadot,
Gilad Mizrachi,
Oded Lipschits,
Yiftah Shalev,
Yiftah Silver,
Amir Weissbein,
Igor Zolkin
Abstract:
We present a novel underground imaging system that utilizes cosmic-ray muons to explore the subsurface environment at the City of David archaeological site in ancient Jerusalem. This report details the initial findings from measurements conducted at a large cistern, commonly called "Jeremiah's cistern" (referenced in Jeremiah 38:6). The system aims to locate and map hidden voids and structural ano…
▽ More
We present a novel underground imaging system that utilizes cosmic-ray muons to explore the subsurface environment at the City of David archaeological site in ancient Jerusalem. This report details the initial findings from measurements conducted at a large cistern, commonly called "Jeremiah's cistern" (referenced in Jeremiah 38:6). The system aims to locate and map hidden voids and structural anomalies within the overburden. Our primary outcome is the derivation of the angular ground depth, which serves as a proxy for understanding the integrated density distribution of the overburden. This work represents a significant interdisciplinary effort to deepen our understanding of this historically important site.
△ Less
Submitted 3 April, 2025;
originally announced April 2025.
-
MATHUSLA: An External Long-Lived Particle Detector to Maximize the Discovery Potential of the HL-LHC
Authors:
Branden Aitken,
Cristiano Alpigiani,
Juan Carlos Arteaga-Velázquez,
Mitchel Baker,
Kincso Balazs,
Jared Barron,
Brian Batell,
Austin Batz,
Yan Benhammou,
Tamara Alice Bud,
Karen Salomé Caballero-Mora,
John Paul Chou,
David Curtin,
Albert de Roeck,
Miriam Diamond,
Mariia Didenko,
Keith R. Dienes,
William Dougherty,
Liam Andrew Dougherty,
Marco Drewes,
Sameer Erramilli,
Erez Etzion,
Arturo Fernández Téllez,
Grace Finlayson,
Oliver Fischer
, et al. (48 additional authors not shown)
Abstract:
We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close pr…
▽ More
We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate reach of the LHC main detectors. This provides unique sensitivity to many LLP signals that are highly theoretically motivated, due to their connection to the hierarchy problem, the nature of dark matter, and baryogenesis. Data taking is projected to commence with the start of HL-LHC operations. We summarize the new 40m design for the detector that was recently presented in the MATHUSLA Conceptual Design Report, alongside new realistic background and signal simulations that demonstrate high efficiency for the main target LLP signals in a background-free HL-LHC search. We argue that MATHUSLA's uniquely robust expansion of the HL-LHC physics reach is a crucial ingredient in CERN's mission to search for new physics and characterize the Higgs boson with precision.
△ Less
Submitted 1 April, 2025;
originally announced April 2025.
-
The Linear Collider Facility (LCF) at CERN
Authors:
H. Abramowicz,
E. Adli,
F. Alharthi,
M. Almanza-Soto,
M. M. Altakach,
S. Ampudia Castelazo,
D. Angal-Kalinin,
J. A. Anguiano,
R. B. Appleby,
O. Apsimon,
A. Arbey,
O. Arquero,
D. Attié,
J. L. Avila-Jimenez,
H. Baer,
Y. Bai,
C. Balazs,
P. Bambade,
T. Barklow,
J. Baudot,
P. Bechtle,
T. Behnke,
A. B. Bellerive,
S. Belomestnykh,
Y. Benhammou
, et al. (386 additional authors not shown)
Abstract:
In this paper we outline a proposal for a Linear Collider Facility as the next flagship project for CERN. It offers the opportunity for a timely, cost-effective and staged construction of a new collider that will be able to comprehensively map the Higgs boson's properties, including the Higgs field potential, thanks to a large span in centre-of-mass energies and polarised beams. A comprehensive pr…
▽ More
In this paper we outline a proposal for a Linear Collider Facility as the next flagship project for CERN. It offers the opportunity for a timely, cost-effective and staged construction of a new collider that will be able to comprehensively map the Higgs boson's properties, including the Higgs field potential, thanks to a large span in centre-of-mass energies and polarised beams. A comprehensive programme to study the Higgs boson and its closest relatives with high precision requires data at centre-of-mass energies from the Z pole to at least 1 TeV. It should include measurements of the Higgs boson in both major production mechanisms, ee -> ZH and ee -> vvH, precision measurements of gauge boson interactions as well as of the W boson, Higgs boson and top-quark masses, measurement of the top-quark Yukawa coupling through ee ->ttH, measurement of the Higgs boson self-coupling through HH production, and precision measurements of the electroweak couplings of the top quark. In addition, ee collisions offer discovery potential for new particles complementary to HL-LHC.
△ Less
Submitted 19 June, 2025; v1 submitted 31 March, 2025;
originally announced March 2025.
-
Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS
Authors:
Branden Aitken,
Cristiano Alpigiani,
Juan Carlos Arteaga-Velázquez,
Mitchel Baker,
Kincso Balazs,
Jared Barron,
Brian Batell,
Austin Batz,
Yan Benhammou,
Tamara Alice Bud,
Karen Salomé Caballero-Mora,
John Paul Chou,
David Curtin,
Albert de Roeck,
Miriam Diamond,
Mariia Didenko,
Keith R. Dienes,
William Dougherty,
Liam Andrew Dougherty,
Marco Drewes,
Sameer Erramilli,
Erez Etzion,
Arturo Fernández Téllez,
Grace Finlayson,
Oliver Fischer
, et al. (48 additional authors not shown)
Abstract:
We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size,…
▽ More
We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.
△ Less
Submitted 26 March, 2025;
originally announced March 2025.
-
A Linear Collider Vision for the Future of Particle Physics
Authors:
H. Abramowicz,
E. Adli,
F. Alharthi,
M. Almanza-Soto,
M. M. Altakach,
S Ampudia Castelazo,
D. Angal-Kalinin,
R. B. Appleby,
O. Apsimon,
A. Arbey,
O. Arquero,
A. Aryshev,
S. Asai,
D. Attié,
J. L. Avila-Jimenez,
H. Baer,
J. A. Bagger,
Y. Bai,
I. R. Bailey,
C. Balazs,
T Barklow,
J. Baudot,
P. Bechtle,
T. Behnke,
A. B. Bellerive
, et al. (391 additional authors not shown)
Abstract:
In this paper we review the physics opportunities at linear $e^+e^-$ colliders with a special focus on high centre-of-mass energies and beam polarisation, take a fresh look at the various accelerator technologies available or under development and, for the first time, discuss how a facility first equipped with a technology mature today could be upgraded with technologies of tomorrow to reach much…
▽ More
In this paper we review the physics opportunities at linear $e^+e^-$ colliders with a special focus on high centre-of-mass energies and beam polarisation, take a fresh look at the various accelerator technologies available or under development and, for the first time, discuss how a facility first equipped with a technology mature today could be upgraded with technologies of tomorrow to reach much higher energies and/or luminosities. In addition, we will discuss detectors and alternative collider modes, as well as opportunities for beyond-collider experiments and R\&D facilities as part of a linear collider facility (LCF). The material of this paper will support all plans for $e^+e^-$ linear colliders and additional opportunities they offer, independently of technology choice or proposed site, as well as R\&D for advanced accelerator technologies. This joint perspective on the physics goals, early technologies and upgrade strategies has been developed by the LCVision team based on an initial discussion at LCWS2024 in Tokyo and a follow-up at the LCVision Community Event at CERN in January 2025. It heavily builds on decades of achievements of the global linear collider community, in particular in the context of CLIC and ILC.
△ Less
Submitted 31 March, 2025; v1 submitted 25 March, 2025;
originally announced March 2025.
-
Novel Silicon and GaAs Sensors for Compact Sampling Calorimeters
Authors:
H. Abramowicz,
M. Almanza Soto,
Y. Benhammou,
W. Daniluk,
M. Elad,
M. Firlej,
T. Fiutowski,
V. Ghenescu,
G. Grzelak,
D. Horn,
S. Huang,
M. Idzik,
A. Irles,
J. Kotula,
A. Levy,
I. Levy,
W. Lohmann,
J. Morón,
A. T. Neagu,
D. Pietruch,
P. M. Potlog,
K. Świentek,
A. F. Żarnecki,
K. Zembaczyński
Abstract:
Two samples of silicon pad sensors and two samples of GaAs sensors are studied in an electron beam with 5 GeV energy from the DESY-II test-beam facility. The sizes of the silicon and GaAs sensors are about 9$\times$9 cm$^2$ and 5$\times$8 cm$^2$, respectively. The thickness is 500 micrometer for both the silicon and GaAs sensors. The pad size is about 5$\times$5 mm$^2$. The sensors are foreseen to…
▽ More
Two samples of silicon pad sensors and two samples of GaAs sensors are studied in an electron beam with 5 GeV energy from the DESY-II test-beam facility. The sizes of the silicon and GaAs sensors are about 9$\times$9 cm$^2$ and 5$\times$8 cm$^2$, respectively. The thickness is 500 micrometer for both the silicon and GaAs sensors. The pad size is about 5$\times$5 mm$^2$. The sensors are foreseen to be used in a compact electromagnetic sampling calorimeter. The readout of the pads is done by metal traces connected to the pads and the front-end ASICs at the edges of the sensors. For the silicon sensors, copper traces on a Kapton foil are connected to the sensor pads with conducting glue. The pads of the GaAs sensors are connected to bond-pads via aluminium traces on the sensor substrate. The readout is based on a dedicated front-end ASIC, called FLAME. Pre-processing of the raw data and deconvolution is performed with FPGAs. The whole system is orchestrated by a Trigger Logic Unit. Results are shown for the signal-to-noise ratio, the homogeneity of the response, edge effects on pads, and for signals due to the readout traces.
△ Less
Submitted 16 June, 2025; v1 submitted 13 January, 2025;
originally announced January 2025.
-
Technical Design Report for the LUXE Experiment
Authors:
H. Abramowicz,
M. Almanza Soto,
M. Altarelli,
R. Aßmann,
A. Athanassiadis,
G. Avoni,
T. Behnke,
M. Benettoni,
Y. Benhammou,
J. Bhatt,
T. Blackburn,
C. Blanch,
S. Bonaldo,
S. Boogert,
O. Borysov,
M. Borysova,
V. Boudry,
D. Breton,
R. Brinkmann,
M. Bruschi,
F. Burkart,
K. Büßer,
N. Cavanagh,
F. Dal Corso,
W. Decking
, et al. (109 additional authors not shown)
Abstract:
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel…
▽ More
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.
△ Less
Submitted 2 August, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
Muon Detector for Underground Tomography
Authors:
Yan Benhammou,
Erez Etzion,
Gilad Mizrachi,
Meny Raviv Moshe,
Yiftah Silver,
Igor Zolkin
Abstract:
We utilise muons from cosmic ray to explore hidden underground archaeological structures. Presented here is the design, simulation studies and first laboratory results of a compact, scintillators based, cosmic ray muon telescope for underground muon radiography.
We utilise muons from cosmic ray to explore hidden underground archaeological structures. Presented here is the design, simulation studies and first laboratory results of a compact, scintillators based, cosmic ray muon telescope for underground muon radiography.
△ Less
Submitted 7 May, 2022;
originally announced May 2022.
-
Detector challenges of the strong-field QED experiment LUXE at the European XFEL
Authors:
Yan Benhammou
Abstract:
The LUXE experiment (Laser Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL (Eu.XFEL). LUXE is intended to study collisions between a high-intensity optical laser and up to 16.5 GeV electrons from the Eu.XFEL electron beam, or, alternatively, high-energy secondary photons. The physics objective of LUXE are processes of Quantum Electr…
▽ More
The LUXE experiment (Laser Und XFEL Experiment) is a new experiment in planning at DESY Hamburg using the electron beam of the European XFEL (Eu.XFEL). LUXE is intended to study collisions between a high-intensity optical laser and up to 16.5 GeV electrons from the Eu.XFEL electron beam, or, alternatively, high-energy secondary photons. The physics objective of LUXE are processes of Quantum Electrodynamics (QED) at the strong-field frontier, where QED is non-perturbative. The design of the experimental setup and the different detectors are presented.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Liquid Scintillators for Large Area Tracking System
Authors:
Yan Benhammou,
Erez Etzion,
Gilad Mizrachi,
Meny Raviv Moshe,
Yiftah Silver
Abstract:
We report on studies of non-toxic scintillating liquid useful for large surface detectors. Arrays of liquid scintillators offer a rather simple tool for detecting charged particles traversing a surface and tracking their path through a defined volume. Insertion of wavelength shifting fibres along the liquid scintillating containers significantly improves the light collection at the two ends of the…
▽ More
We report on studies of non-toxic scintillating liquid useful for large surface detectors. Arrays of liquid scintillators offer a rather simple tool for detecting charged particles traversing a surface and tracking their path through a defined volume. Insertion of wavelength shifting fibres along the liquid scintillating containers significantly improves the light collection at the two ends of the scintillators. We have demonstrated that we can achieve timing resolution of O(1 ns) allowing good spatial resolution. Liquid scintillators with fibres read by Photo-multipliers or SiPMs provide an inexpensive alternative technology which suits well the requirement of the MATHUSLA experiment tracking system.
△ Less
Submitted 29 April, 2020;
originally announced April 2020.
-
Letter of Intent for the LUXE Experiment
Authors:
H. Abramowicz,
M. Altarelli,
R. Aßmann,
T. Behnke,
Y. Benhammou,
O. Borysov,
M. Borysova,
R. Brinkmann,
F. Burkart,
K. Büßer,
O. Davidi,
W. Decking,
N. Elkina,
H. Harsh,
A. Hartin,
I. Hartl,
B. Heinemann,
T. Heinzl,
N. TalHod,
M. Hoffmann,
A. Ilderton,
B. King,
A. Levy,
J. List,
A. R. Maier
, et al. (12 additional authors not shown)
Abstract:
This Letter of Intent describes LUXE (Laser Und XFEL Experiment), an experiment that aims to use the high-quality and high-energy electron beam of the European XFEL and a powerful laser. The scientific objective of the experiment is to study quantum electrodynamics processes in the regime of strong fields. High-energy electrons, accelerated by the European XFEL linear accelerator, and high-energy…
▽ More
This Letter of Intent describes LUXE (Laser Und XFEL Experiment), an experiment that aims to use the high-quality and high-energy electron beam of the European XFEL and a powerful laser. The scientific objective of the experiment is to study quantum electrodynamics processes in the regime of strong fields. High-energy electrons, accelerated by the European XFEL linear accelerator, and high-energy photons, produced via Bremsstrahlung of those beam electrons, colliding with a laser beam shall experience an electric field up to three times larger than the Schwinger critical field (the field at which the vacuum itself is expected to become unstable and spark with spontaneous creation of electron-positron pairs) and access a new regime of quantum physics. The processes to be investigated, which include nonlinear Compton scattering and nonlinear Breit-Wheeler pair production, are relevant to a variety of phenomena in Nature, e.g. in the areas of astrophysics and collider physics and complement recent results in atomic physics. The setup requires in particular the extraction of a minute fraction of the electron bunches from the European XFEL accelerator, the installation of a powerful laser with sophisticated diagnostics, and an array of precision detectors optimised to measure electrons, positrons and photons. Physics sensitivity projections based on simulations are also provided.
△ Less
Submitted 2 September, 2019;
originally announced September 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
O. Borysov,
M. Borysova,
I. Bozovic- Jelisavcic,
W. Daniluk,
D. Dannheim,
M. Demichev,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempelb,
H. Henschel,
M. Idzik,
A. Ignatenkoc,
A. Ishikawa,
A. Joffe,
G. Kacarevic,
S. Kananov,
O. Karachebanb
, et al. (29 additional authors not shown)
Abstract:
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY wi…
▽ More
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.
△ Less
Submitted 25 October, 2019; v1 submitted 29 December, 2018;
originally announced December 2018.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode
Authors:
A. Mulski,
Y. Benhammou,
J. W. Chapman,
A. Das,
E. Etzion,
C. Ferretti,
P. S. Friedman,
R. P. Johnson,
D. S. Levin,
N. Kamp,
H. Ochoa,
M. Raviv-Moshe,
N. Ristow
Abstract:
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and her…
▽ More
The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and hermetically sealed gaseous tracking detector with high rate ( > 100 KHz/cm^2 ) capability. The devices reported here were fabricated as 16 x 16 pixel arrays of 2 mm edge-to-edge, 1 mm deep hexagonal cells embedded in a thin, 1.4 mm glass-ceramic wafer. Cell walls are metalized cathodes, connected to high voltage bus lines through conductive vias. Anodes are small, 457 micron diameter metal discs screen printed on the upper substrate. The detectors are filled with an operating gas to near 1 atm and then closed with a shut-off valve. They have been operated in both avalanche mode and gas discharge devices, producing mV to volt level signals with about 1 to 3 ns rise times. Operation in discharge mode is enabled by high impedance quench resistors on the high voltage bus at each pixel site. Results indicate that each individual pixel behaves as an isolated detection unit with high single pixel intrinsic efficiency to both beta's from radioactive sources and to cosmic ray muons. Continuous avalanche mode operation over several days at hit rates over 300 KHz/cm^2 with no gas flow have been observed. Measurements of pixel isolation, timing response, efficiency, hit rate and rate stability are reported.
△ Less
Submitted 24 October, 2018;
originally announced October 2018.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Study of the performance of a compact sandwich calorimeter for the instrumentation of the very forward region of a future linear collider detector
Authors:
V. Ghenescu,
Y. Benhammou
Abstract:
The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These calorimeters are designed as sensor-tungsten calorimeters with very thin sensor planes to keep the Moliere radius small and dedicated FE electronics to match the ti…
▽ More
The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These calorimeters are designed as sensor-tungsten calorimeters with very thin sensor planes to keep the Moliere radius small and dedicated FE electronics to match the timing and dynamic range requirements. A partially instrumented prototype was investigated in the CERN PS T9 beam in 2014 and at the DESY-II Synchrotron in 2015. It was operated in a mixed particle beam (electrons, muons and hadrons) of 5 GeV from PS facilities and with secondary electrons of 5 GeV energy from DESY-II. The results demonstrated a very good performance of the full readout chain. The high statistics data were used to study the response to different particles, perform sensor alignment and measure the longitudinal shower development in the sandwich. In addition, Geant4 MC simulations were done, and compared to the data.
△ Less
Submitted 7 April, 2016;
originally announced April 2016.
-
Performance of a Full-Size Small-Strip Thin Gap Chamber Prototype for the ATLAS New Small Wheel Muon Upgrade
Authors:
Angel Abusleme,
Camille Bélanger-Champagne,
Alain Bellerive,
Yan Benhammou,
James Botte,
Hadar Cohen,
Merlin Davies,
Yanyan Du,
Lea Gauthier,
Thomas Koffas,
Serguei Kuleshov,
Benoit Lefebvre,
Changyu Li,
Nachman Lupu,
Giora Mikenberg,
Daniel Mori,
Jean-Pierre Ochoa-Ricoux,
Estel Perez Codina,
Sebastien Rettie,
Andree Robichaud-Véronneau,
Rimsky Rojas,
Meir Shoa,
Vladimir Smakhtin,
Bernd Stelzer,
Oliver Stelzer-Chilton
, et al. (10 additional authors not shown)
Abstract:
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs…
▽ More
The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs will be installed during the LHC long shutdown in 2018/19. Small-Strip Thin Gap Chamber (sTGC) detectors are designed to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. To validate the design, a full-size prototype sTGC detector of approximately 1.2 $\times$ $1.0\, \mathrm{m}^2$ consisting of four gaps has been constructed. Each gap provides pad, strip and wire readouts. The sTGC intrinsic spatial resolution has been measured in a $32\, \mathrm{GeV}$ pion beam test at Fermilab. At perpendicular incidence angle, single gap position resolutions of about $50\,\mathrm{μm}$ have been obtained, uniform along the sTGC strip and perpendicular wire directions, well within design requirements. Pad readout measurements have been performed in a $130\, \mathrm{GeV}$ muon beam test at CERN. The transition region between readout pads has been found to be $4\,\mathrm{mm}$, and the pads have been found to be fully efficient.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
First results with a microcavity plasma panel detector
Authors:
R. Ball,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
M. Davies,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
B. Zhou
Abstract:
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles fro…
▽ More
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.
△ Less
Submitted 3 December, 2014; v1 submitted 24 July, 2014;
originally announced July 2014.
-
Development of a plasma panel radiation detector
Authors:
R. Ball,
J. R. Beene,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
R. Wetzel,
B. Zhou,
T. Anderson,
K. McKinny,
E. H. Bentefour
Abstract:
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were t…
▽ More
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were tested with cosmic ray muons, beta rays and gamma rays, protons and thermal neutrons. The results demonstrated rise times and time resolution of a few nanoseconds, as well as sub-millimeter spatial resolution compatible with the pixel pitch.
△ Less
Submitted 14 June, 2014; v1 submitted 13 March, 2014;
originally announced March 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Plasma panel-based radiation detectors
Authors:
Peter Friedman,
Robert Ball,
James Beene,
Yan Benhammou,
Meny Ben-Moshe,
Hassan Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Daniel Levin,
Yiftah Silver,
Robert Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates…
▽ More
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50-mm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low-to-medium energy, thermal neutrons, and X-rays.
△ Less
Submitted 10 May, 2013;
originally announced May 2013.
-
Plasma Panel Sensors for Particle and Beam Detection
Authors:
Peter S. Friedman,
Robert Ball,
James R. Beene,
Yan Benhammou,
E. H. Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Daniel S. Levin,
Meny Ben-Moshe,
Yiftah Silver,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials…
▽ More
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials such as glass substrates, metal electrodes and mostly inert gas mixtures. We are developing the technology to fabricate these devices with very low mass and small thickness, using gas gaps of at least a few hundred micrometers. Our tests with these devices demonstrate a spatial resolution of about 1 mm. We intend to make PPS devices with much smaller cells and the potential for much finer position resolutions. Our PPS tests also show response times of several nanoseconds. We report here our results in detecting betas, cosmic-ray muons, and our first proton beam tests.
△ Less
Submitted 22 November, 2012;
originally announced November 2012.
-
Development of a plasma panel radiation detector: recent progress and key issues
Authors:
Yiftah Silver,
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben-Moshe,
J. W. Chapman,
Tiesheng Dai,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Peter S. Friedman,
Daniel S. Levin,
S. Ritt,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pi…
▽ More
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.
△ Less
Submitted 30 May, 2012;
originally announced May 2012.
-
The Detection of Ionizing Radiation by Plasma Panel Sensors: Cosmic Muons, Ion Beams and Cancer Therapy
Authors:
Peter S. Friedman,
Robert Ball,
J. W. Chapman,
Claudio Ferretti,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
Nir Guttman,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
△ Less
Submitted 3 April, 2012;
originally announced April 2012.
-
Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Progress in the Development of Plasma Panel Radiation Detectors
Authors:
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben Moshe,
J. Wehrley Chapman,
Tiesheng Dai,
Erez Etzion,
Peter S. Friedman,
Daniel S. Levin,
Yiftah Silver,
Guy Sherman,
Robert L. Varner Jr.,
Curtis Weaverdyck,
Steve White,
J. Yu,
Bing Zhou
Abstract:
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We r…
▽ More
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including recent laboratory measurements.
△ Less
Submitted 30 December, 2010;
originally announced January 2011.
-
Large-Area Plasma-Panel Radiation Detectors for Nuclear Medicine Imaging to Homeland Security and the Super Large Hadron Collider
Authors:
Peter S. Friedman,
Robert Ball,
J. Wehrley Chapman,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
△ Less
Submitted 3 July, 2010;
originally announced July 2010.
-
Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC
Authors:
Nir Amram,
Gideon Bella,
Yan Benhammou,
Marco A. Diaz,
Ehud Duchovni,
Erez Etzion,
Alon Hershenhorn,
Amit Klier,
Nachman Lupu,
Giora Mikenberg,
Dmitry Milstein,
Yonathan Munwes,
Osamu Sasaki,
Meir Shoa,
Vladimir Smakhtin,
Ulrich Volkmann
Abstract:
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strip…
▽ More
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strips and wires readout, with a total thickness of 50 mm, have been constructed. Their local spatial resolution has been measured in a 100 GeV/c muon test beam at CERN. At perpendicular incidence angle, single gap position resolution better than 60 microns has been obtained. For incidence angle of 20 degrees resolution of less than 100 micron was achieved. TGC prototypes were also tested under a flux of 10^5 Hz/cm^2 of 5.5-6.5 MeV neutrons, showing a high efficiency for cosmic muons detection.
△ Less
Submitted 2 June, 2010; v1 submitted 1 June, 2010;
originally announced June 2010.
-
The Thin Gap Chambers database experience in test beam and preparations for ATLAS
Authors:
Y. Benhammou,
E. Etzion,
S. Bressler,
S. Tarem,
D. Lellouch,
L. Levinson
Abstract:
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last few years. A relational database was used for storing the conditions of t…
▽ More
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last few years. A relational database was used for storing the conditions of the tests as well as the configuration of the system. This database has provided the detector control system with the information needed for configuration of the front end electronics. The database is used to assist the online operation and maintenance. The same database is used to store the non event condition and configuration parameters needed later for the offline reconstruction software. A larger scale of the database has been produced to support the whole TGC system. It integrates all the production, QA tests and assembly information. A 1/12th model of the whole TGC system is currently in use for testing the performance of this database in configuring and tracking the condition of the system. A prototype of the database was first implemented during the H8 test beams. This paper describes the database structure, its interface to other systems and its operational performance.
△ Less
Submitted 26 September, 2005;
originally announced September 2005.
-
The Certification of ATLAS Thin Gap Chambers Produced in Israel and China
Authors:
E. Etzion,
Y. Benhammou,
J. Ginzburg,
M. Ishino,
L. Levinson,
G. Mikenberg,
N. Panikashvili,
D. Primor,
Y. Rozen,
V. Smakhtin,
S. Tarem
Abstract:
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. A TGC consists of a plane of closely spaced wires maintained at positive high voltage, sandwiched between resistive grounded cathode planes with an anode wire to cathode plane gap distance smaller than the wire-to-wire spacing. The TGCs are expected to provide a trigger signal within…
▽ More
Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. A TGC consists of a plane of closely spaced wires maintained at positive high voltage, sandwiched between resistive grounded cathode planes with an anode wire to cathode plane gap distance smaller than the wire-to-wire spacing. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing of the LHC accelerator, with an efficiency exceeding 95%, while exposed to an effective photon and neutron background ranging from 30 to 500 Hz/cm2. About 2,500 out of the 3,600 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Once installed in the ATLAS detector the TGCs will be inaccessible. A vigorous production quality control program is therefore implemented at the production sites. Furthermore, after chamber completion, a thorough program of quality assurance is implemented to ensure the efficient performance of the chambers during more than ten years of operation in the LHC high rate environment. This program consists of a detailed mapping of the detectors response using cosmic rays, as well as checking the chambers behavior using a high rate radiation source. An aging test performed on five chambers in a serial gas connection is presented. Finally the results of the chambers certification tests performed at CERN before the installation in ATLAS are described.
△ Less
Submitted 15 November, 2004;
originally announced November 2004.
-
Using a neural network approach for muon reconstruction and triggering
Authors:
E. Etzion,
H. Abramowicz,
Y. Benhammou,
D. Horn,
L. Levinson,
R. Livneh
Abstract:
The extremely high rate of events that will be produced in the future Large Hadron Collider requires the triggering mechanism to take precise decisions in a few nano-seconds. We present a study which used an artificial neural network triggering algorithm and compared it to the performance of a dedicated electronic muon triggering system. Relatively simple architecture was used to solve a complic…
▽ More
The extremely high rate of events that will be produced in the future Large Hadron Collider requires the triggering mechanism to take precise decisions in a few nano-seconds. We present a study which used an artificial neural network triggering algorithm and compared it to the performance of a dedicated electronic muon triggering system. Relatively simple architecture was used to solve a complicated inverse problem. A comparison with a realistic example of the ATLAS first level trigger simulation was in favour of the neural network. A similar architecture trained after the simulation of the electronics first trigger stage showed a further background rejection.
△ Less
Submitted 16 February, 2004;
originally announced February 2004.
-
The Cosmic Ray Hodoscopes for Testing Thin Gap Chambers at the Technion and Tel Aviv University
Authors:
E. Etzion,
H. Abramowicz,
N. Amram,
Y. Benhammou,
M. Ben-Moshe,
G. Bella,
J. Ginzburg,
Y. Gernitzky,
A. Harel,
H. Landsman,
N. Panikashvili,
Y. Rozen,
S. Tarem,
E. Warszawski,
J. Wasilewski,
L. Levinson
Abstract:
Thin gap chambers (TGCs) are built for the muon trigger chambers in the endcap region of the LHC experiment ATLAS. More than 2500 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Detailed testing of these chambers is performed at the Technion and at the Tel-Aviv University. Two cosmic ray hodoscopes for testing the operation of these detecto…
▽ More
Thin gap chambers (TGCs) are built for the muon trigger chambers in the endcap region of the LHC experiment ATLAS. More than 2500 ATLAS TGCs are being produced at the Weizmann institute in Israel, and in Shandong University in China. Detailed testing of these chambers is performed at the Technion and at the Tel-Aviv University. Two cosmic ray hodoscopes for testing the operation of these detectors were built in Israel. In these hodoscopes the response of the chambers to energetic cosmic ray muons is recorded and analyzed. The hodoscopes measure the exact time and space location of the cosmic ray hit and read out the chambers which are being tested to verify that they produce a corresponding signal within the required time interval. The cosmic ray hodoscopes built at the Technion and at the Tel Aviv University for the test of ATLAS TGCs are described. The mechanical structure, readout electronics, data acquisition and operating scheme are presented. Typical TGC test results are presented and discussed.
△ Less
Submitted 19 February, 2004; v1 submitted 11 December, 2003;
originally announced December 2003.