-
Measurements of molecular size and shape on a chip
Authors:
Xin Zhu,
Timothy JD Bennett,
Konstantin C Zouboulis,
Dimitrios Soulias,
Michal Grzybek,
Justin LP Benesch,
Afaf H El-Sagheer,
Ünal Coskun,
Madhavi Krishnan
Abstract:
Size and shape are critical discriminators between molecular species and states. We describe a micro-chip based high-throughput imaging approach offering rapid and precise determination of molecular properties under native solution conditions. Our method detects differences in molecular weight across at least three orders of magnitude, and down to two carbon atoms in small molecules. We quantify t…
▽ More
Size and shape are critical discriminators between molecular species and states. We describe a micro-chip based high-throughput imaging approach offering rapid and precise determination of molecular properties under native solution conditions. Our method detects differences in molecular weight across at least three orders of magnitude, and down to two carbon atoms in small molecules. We quantify the strength of molecular interactions over six orders of magnitude in affinity constant, and track reactions in real-time. Highly parallel measurements on individual molecules serve to characterize sample-state heterogeneity at the highest resolution, offering predictive input to model three-dimensional structure. We further leverage the method's structural sensitivity for diagnostics, exploiting ligand-induced conformational changes in the insulin receptor to sense insulin concentration in serum at the sub-nanoliter and sub-zeptomole scale.
△ Less
Submitted 13 May, 2025;
originally announced May 2025.
-
The SHMS 11 GeV/c Spectrometer in Hall C at Jefferson Lab
Authors:
S. Ali,
A. Ahmidouch,
G. R. Ambrose,
A. Asaturyan,
C. Ayerbe Gayoso,
J. Benesch,
V. Berdnikov,
H. Bhatt,
D. Bhetuwal,
D. Biswas,
P. Brindza,
M. Bukhari,
M. Burton,
R. Carlini,
M. Carmignotto,
M. E. Christy,
C. Cotton,
J. Crafts,
D. Day,
S. Danagoulian,
A. Dittmann,
D. H. Dongwi,
B. Duran,
D. Dutta,
R. Ent
, et al. (50 additional authors not shown)
Abstract:
The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnet…
▽ More
The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5 to 40 degrees, thus allowing a wide range of low cross-section experiments to be conducted. These experiments complement and extend the previous Hall C research program to higher energies.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
Harnessing the Power of Gradient-Based Simulations for Multi-Objective Optimization in Particle Accelerators
Authors:
Kishansingh Rajput,
Malachi Schram,
Auralee Edelen,
Jonathan Colen,
Armen Kasparian,
Ryan Roussel,
Adam Carpenter,
He Zhang,
Jay Benesch
Abstract:
Particle accelerator operation requires simultaneous optimization of multiple objectives. Multi-Objective Optimization (MOO) is particularly challenging due to trade-offs between the objectives. Evolutionary algorithms, such as genetic algorithm (GA), have been leveraged for many optimization problems, however, they do not apply to complex control problems by design. This paper demonstrates the po…
▽ More
Particle accelerator operation requires simultaneous optimization of multiple objectives. Multi-Objective Optimization (MOO) is particularly challenging due to trade-offs between the objectives. Evolutionary algorithms, such as genetic algorithm (GA), have been leveraged for many optimization problems, however, they do not apply to complex control problems by design. This paper demonstrates the power of differentiability for solving MOO problems using a Deep Differentiable Reinforcement Learning (DDRL) algorithm in particle accelerators. We compare DDRL algorithm with Model Free Reinforcement Learning (MFRL), GA and Bayesian Optimization (BO) for simultaneous optimization of heat load and trip rates in the Continuous Electron Beam Accelerator Facility (CEBAF). The underlying problem enforces strict constraints on both individual states and actions as well as cumulative (global) constraint for energy requirements of the beam. A physics-based surrogate model based on real data is developed. This surrogate model is differentiable and allows back-propagation of gradients. The results are evaluated in the form of a Pareto-front for two objectives. We show that the DDRL outperforms MFRL, BO, and GA on high dimensional problems.
△ Less
Submitted 7 November, 2024;
originally announced November 2024.
-
Positron Beams At Ce$^+$BAF
Authors:
J. Grames,
J. Benesch,
M. Bruker,
L. Cardman,
S. Covrig,
P. Ghoshal,
S. Gopinath,
J. Gubeli,
S. Habet,
C. Hernandez-Garcia,
A. Hofler,
R. Kazimi,
F. Lin,
S. Nagaitsev,
M. Poelker,
B. Rimmer,
Y. Roblin,
V. Lizarraga-Rubio,
A. Seryi,
M. Spata,
A. Sy,
D. Turner,
A. Ushakov,
C. A. Valerio-Lizarraga,
E. Voutier
Abstract:
We present a scheme for the generation of a high polarization positron beam with continous wave (CW) bunch structure for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab). The positrons are created in a high average power conversion target and collected by a CW capture linac and DC solenoid.
We present a scheme for the generation of a high polarization positron beam with continous wave (CW) bunch structure for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab). The positrons are created in a high average power conversion target and collected by a CW capture linac and DC solenoid.
△ Less
Submitted 27 September, 2023;
originally announced September 2023.
-
A Simple Modification of DC Current Septa to Reduce Current Density by Half
Authors:
Jay Benesch
Abstract:
Circular accelerators typically have one injection and one extraction septum magnet. CEBAF is a recircuating electron linac which has a total of 27 DC current septa and one Lambertson. Current densities range from 28-48 A/mm 2 . Current sheet widths are 5-24 mm, turns count 5-24 and lengths 1000-3000 mm. A design exercise to increase the beam energy to 22 GeV is underway. Since doubling the curren…
▽ More
Circular accelerators typically have one injection and one extraction septum magnet. CEBAF is a recircuating electron linac which has a total of 27 DC current septa and one Lambertson. Current densities range from 28-48 A/mm 2 . Current sheet widths are 5-24 mm, turns count 5-24 and lengths 1000-3000 mm. A design exercise to increase the beam energy to 22 GeV is underway. Since doubling the current density in copper is not practical in the CEBAF layout a conductively cooled superconducting septum concept was examined. Putting the current sheet and its cryostat between the poles as in a standard current sheet septum would have required 90 mm pole gap. The poles were brought to 40 mm separation and the steel notched for the 90 mm cryostat. The field in the bore increased while the field outside the current sheet remained close to zero as in a conventional septum. Required current density dropped enough that a copper coil became possible. Two examples will be shown, the one discussed above and the modification of the 3000 mm septum with 0.92 T bore field.
△ Less
Submitted 18 May, 2023;
originally announced September 2023.
-
The Solenoidal Large Intensity Device (SoLID) for JLab 12 GeV
Authors:
John Arrington,
Jay Benesch,
Alexandre Camsonne,
Jimmy Caylor,
Jian-Ping Chen,
Silviu Covrig Dusa,
Alexander Emmert,
George Evans,
Haiyan Gao,
J. Ole Hansen,
Garth M. Huber,
Sylvester Joosten,
Vladimir Khachatryan,
Nilanga Liyanage,
Zein-Eddine Meziani,
Michael Nycz,
Chao Peng,
Michael Paolone,
Whit Seay,
Paul A. Souder,
Nikos Sparveris,
Hubert Spiesberger,
Ye Tian,
Eric Voutier,
Junqi Xie
, et al. (6 additional authors not shown)
Abstract:
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensit…
▽ More
The Solenoidal Large Intensity Device (SoLID) is a new experimental apparatus planned for Hall A at the Thomas Jefferson National Accelerator Facility (JLab). SoLID will combine large angular and momentum acceptance with the capability to handle very high data rates at high luminosity. With a slate of approved high-impact physics experiments, SoLID will push JLab to a new limit at the QCD intensity frontier that will exploit the full potential of its 12 GeV electron beam. In this paper, we present an overview of the rich physics program that can be realized with SoLID, which encompasses the tomography of the nucleon in 3-D momentum space from Semi-Inclusive Deep Inelastic Scattering (SIDIS), expanding the phase space in the search for new physics and novel hadronic effects in parity-violating DIS (PVDIS), a precision measurement of $J/ψ$ production at threshold that probes the gluon field and its contribution to the proton mass, tomography of the nucleon in combined coordinate and momentum space with deep exclusive reactions, and more. To meet the challenging requirements, the design of SoLID described here takes full advantage of recent progress in detector, data acquisition and computing technologies. In addition, we outline potential experiments beyond the currently approved program and discuss the physics that could be explored should upgrades of CEBAF become a reality in the future.
△ Less
Submitted 12 February, 2023; v1 submitted 18 September, 2022;
originally announced September 2022.
-
Redesigning the Jefferson Lab Hall A Beam Line for High Precision Parity Experiments
Authors:
Jay Benesch,
Yves Roblin
Abstract:
The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line without consultation with the accelerator physics group. The beam raster system was placed aft…
▽ More
The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line without consultation with the accelerator physics group. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a member of the accelerator physics group had a sixth quadrupole installed downstream of the Moller polarimeter. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This paper documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.
△ Less
Submitted 26 November, 2021; v1 submitted 13 September, 2021;
originally announced September 2021.
-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
FEM models and Fourier decomposition of three thick septa
Authors:
J. Benesch
Abstract:
The CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lambertson. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features of both. The last has higher-order field components within a factor of two of the current-sheet septum and much lower current density in the conductor were it us…
▽ More
The CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lambertson. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features of both. The last has higher-order field components within a factor of two of the current-sheet septum and much lower current density in the conductor were it used as a drop-in replacement in CEBAF. There are accelerator layouts in which the new concept is superior to the current sheet septum in both harmonic content and current density.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
A novel comparison of Møller and Compton electron-beam polarimeters
Authors:
J. A. Magee,
A. Narayan,
D. Jones,
R. Beminiwattha,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
J. Hoskins,
E. Ihloff,
R. Jones,
P. M. King,
S. Kowalski,
L. Kurchaninov,
L. Lee
, et al. (16 additional authors not shown)
Abstract:
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimete…
▽ More
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Møller measurements made at low beam currents to physics experiments performed at higher beam currents. The agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.
△ Less
Submitted 25 January, 2017; v1 submitted 19 October, 2016;
originally announced October 2016.
-
Production of highly-polarized positrons using polarized electrons at MeV energies
Authors:
D. Abbott,
P. Adderley,
A. Adeyemi,
P. Aguilera,
M. Ali,
H. Areti,
M. Baylac,
J. Benesch,
G. Bosson,
B. Cade,
A. Camsonne,
L. S. Cardman,
J. Clark,
P. Cole,
S. Covert,
C. Cuevas,
O. Dadoun,
D. Dale,
H. Dong,
J. Dumas,
E. Fanchini,
T. Forest,
E. Forman,
A. Freyberger,
E. Froidefond
, et al. (40 additional authors not shown)
Abstract:
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an…
▽ More
The Polarized Electrons for Polarized Positrons experiment at the injector of the Continuous Electron Beam Accelerator Facility has demonstrated for the first time the efficient transfer of polarization from electrons to positrons produced by the polarized bremsstrahlung radiation induced by a polarized electron beam in a high-$Z$ target. Positron polarization up to 82\% have been measured for an initial electron beam momentum of 8.19~MeV/$c$, limited only by the electron beam polarization. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community.
△ Less
Submitted 28 June, 2016;
originally announced June 2016.
-
Precision Electron-Beam Polarimetry using Compton Scattering at 1 GeV
Authors:
A. Narayan,
D. Jones,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
E. Ihloff,
R. Jones,
S. Kowalski,
L. Kurchaninov,
L. Lee,
A. McCreary,
M. McDonald,
A. Micherdzinska,
A. Mkrtchyan
, et al. (11 additional authors not shown)
Abstract:
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micr…
▽ More
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~μ$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1\% per hour and a systematic uncertainty of 0.59\%. This exceeds the level of precision required by the \qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4\%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.
△ Less
Submitted 17 February, 2016; v1 submitted 22 September, 2015;
originally announced September 2015.
-
A longitudinal study of field emission in CEBAF's SRF cavities 1995-2015
Authors:
Jay Benesch
Abstract:
Field emission is one of the key issues in superconducting RF. When present, it limits operating gradient directly or via induced heat load at 2K. In order to minimize particulate contamination of and thus field emission in the CEBAF SRF cavities during assembly, a ceramic RF window was placed very close to the accelerating cavity proper. As an unintended consequence of this, it has been possible…
▽ More
Field emission is one of the key issues in superconducting RF. When present, it limits operating gradient directly or via induced heat load at 2K. In order to minimize particulate contamination of and thus field emission in the CEBAF SRF cavities during assembly, a ceramic RF window was placed very close to the accelerating cavity proper. As an unintended consequence of this, it has been possible to monitor and model field emission in the CEBAF cavities since in-tunnel operation began. The ceramic is charged by field emission to a stable voltage and then discharges. This phenomenon had to be studied statistically to minimize the number of interruptions to accelerator operation for nuclear physics. We report here the results of our twenty year study of this and related phenomena.
△ Less
Submitted 11 October, 2015; v1 submitted 24 February, 2015;
originally announced February 2015.
-
Solid core dipoles and switching power supplies: lower cost light sources?
Authors:
Jay Benesch,
Sarin Philip,
Thomas Jefferson National Accelerator Facility
Abstract:
As a result of improvements in power semiconductors, moderate frequency switching supplies can now provide the hundreds of amps typically required by accelerators with zero-to-peak noise in the kHz region ~0.06% in current or voltage mode. Modeling was undertaken using a finite electromagnetic program to determine if eddy currents induced in the solid steel of CEBAF magnets and small supplemental…
▽ More
As a result of improvements in power semiconductors, moderate frequency switching supplies can now provide the hundreds of amps typically required by accelerators with zero-to-peak noise in the kHz region ~0.06% in current or voltage mode. Modeling was undertaken using a finite electromagnetic program to determine if eddy currents induced in the solid steel of CEBAF magnets and small supplemental additions would bring the error fields down to the 5ppm level needed for beam quality. The expected maximum field of the magnet under consideration is 0.85T and the DC current required to produce that field is used in the calculations. An additional 0.1% current ripple is added to the DC current at discrete frequencies 360 Hz, 720 Hz or 7200 Hz. Over the region of the pole within 0.5% of the central integrated BdL the resulting AC field changes can be reduced to less than 1% of the 0.1% input ripple for all frequencies, and a sixth of that at 7200 Hz. Doubling the current, providing 1.5T central field, yielded the same fractional reduction in ripple at the beam for the cases checked. For light sources with aluminum vacuum vessels and full energy linac injection, the combination of solid core dipoles and switching power supplies may result in significant cost savings.
△ Less
Submitted 23 February, 2015;
originally announced February 2015.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Primary Beam Steering Due to Field Leakage from Superconducting SHMS Magnets
Authors:
Michael H. Moore,
Buddhini P. Waidyawansa,
Silviu Covrig,
Roger Carlini,
Jay Benesch
Abstract:
Simulations of the magnetic fields from the Super High Momentum Spectrometer in Hall C at Thomas Jefferson National Accelerator Facility show significant field leakage into the region of the primary beam line between the target and the beam dump. Without mitigation, these remnant fields will steer the unscattered beam enough to limit beam operations at small scattering angles. Presented here are m…
▽ More
Simulations of the magnetic fields from the Super High Momentum Spectrometer in Hall C at Thomas Jefferson National Accelerator Facility show significant field leakage into the region of the primary beam line between the target and the beam dump. Without mitigation, these remnant fields will steer the unscattered beam enough to limit beam operations at small scattering angles. Presented here are magnetic field simulations of the spectrometer magnets and a solution using optimal placement of a minimal amount of shielding iron around the beam line.
△ Less
Submitted 26 August, 2014; v1 submitted 30 June, 2014;
originally announced June 2014.
-
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
Authors:
R. D. Carlini,
J. M. Finn,
S. Kowalski,
S. A. Page,
D. S. Armstrong,
A. Asaturyan,
T. Averett,
J. Benesch,
J. Birchall,
P. Bosted,
A. Bruell,
C. L. Capuano,
G. Cates,
C. Carrigee,
S. Chattopadhyay,
S. Covrig,
C. A. Davis,
K. Dow,
J. Dunne,
D. Dutta,
R. Ent,
J. Erler,
W. Falk,
H. Fenker,
T. A. Forest
, et al. (61 additional authors not shown)
Abstract:
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep…
▽ More
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.
△ Less
Submitted 7 February, 2012; v1 submitted 6 February, 2012;
originally announced February 2012.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.
-
Field Emission in CEBAF's Superconducting RF Cavities and Implications for Future Accelerators
Authors:
Jay Benesch
Abstract:
Field emission is one of the key issues in superconducting RF for particle accelerators. When present, it limits operating gradient directly or via induced heat load at 2K. In order to minimize particulate contamination of and thus field emission in the CEBAF SRF cavities during assembly, a cold ceramic RF window was placed very close to the accelerating cavity proper. As an unintended consequen…
▽ More
Field emission is one of the key issues in superconducting RF for particle accelerators. When present, it limits operating gradient directly or via induced heat load at 2K. In order to minimize particulate contamination of and thus field emission in the CEBAF SRF cavities during assembly, a cold ceramic RF window was placed very close to the accelerating cavity proper. As an unintended consequence of this, the window is charged by field-emitted electrons, making it possible to monitor and model field emission in the CEBAF cavities since in-tunnel operation began. From January 30, 1995, through February 10, 2003, there were 64 instances of spontaneous onset or change in cavity field emission with a drop in usable gradient averaging 1.4 (sigma 0.8) MV/m at each event. Fractional loss averaged 0.18 (sigma 0.12) of pre-event gradient. This event count corresponds to 2.4 events per century per cavity, or 8 per year in CEBAF. It is hypothesized that changes in field emission are due to adsorbed gas accumulation. The possible implications of this and other observations for the International Linear Collider (ILC) and other future accelerators will be discussed.
△ Less
Submitted 2 October, 2007; v1 submitted 15 June, 2006;
originally announced June 2006.