Objective Features Extracted from Motor Activity Time Series for Food Addiction Analysis Using Machine Learning
Authors:
Mikhail Borisenkov,
Andrei Velichko,
Maksim Belyaev,
Dmitry Korzun,
Tatyana Tserne,
Larisa Bakutova,
Denis Gubin
Abstract:
This study investigates machine learning algorithms to identify objective features for diagnosing food addiction (FA) and assessing confirmed symptoms (SC). Data were collected from 81 participants (mean age: 21.5 years, range: 18-61 years, women: 77.8%) whose FA and SC were measured using the Yale Food Addiction Scale (YFAS). Participants provided demographic and anthropometric data, completed th…
▽ More
This study investigates machine learning algorithms to identify objective features for diagnosing food addiction (FA) and assessing confirmed symptoms (SC). Data were collected from 81 participants (mean age: 21.5 years, range: 18-61 years, women: 77.8%) whose FA and SC were measured using the Yale Food Addiction Scale (YFAS). Participants provided demographic and anthropometric data, completed the YFAS, the Zung Self-Rating Depression Scale, and the Dutch Eating Behavior Questionnaire, and wore an actimeter on the non-dominant wrist for a week to record motor activity. Analysis of the actimetric data identified significant statistical and entropy-based features that accurately predicted FA and SC using ML. The Matthews correlation coefficient (MCC) was the primary metric. Activity-related features were more effective for FA prediction (MCC=0.88) than rest-related features (MCC=0.68). For SC, activity segments yielded MCC=0.47, rest segments MCC=0.38, and their combination MCC=0.51. Significant correlations were also found between actimetric features related to FA, emotional, and restrained eating behaviors, supporting the model's validity. Our results support the concept of a human bionic suite composed of IoT devices and ML sensors, which implements health digital assistance with real-time monitoring and analysis of physiological indicators related to FA and SC.
△ Less
Submitted 5 December, 2024; v1 submitted 30 August, 2024;
originally announced September 2024.
-
Entropy-based machine learning model for diagnosis and monitoring of Parkinson's Disease in smart IoT environment
Authors:
Maksim Belyaev,
Murugappan Murugappan,
Andrei Velichko,
Dmitry Korzun
Abstract:
The study presents the concept of a computationally efficient machine learning (ML) model for diagnosing and monitoring Parkinson's disease (PD) in an Internet of Things (IoT) environment using rest-state EEG signals (rs-EEG). We computed different types of entropy from EEG signals and found that Fuzzy Entropy performed the best in diagnosing and monitoring PD using rs-EEG. We also investigated di…
▽ More
The study presents the concept of a computationally efficient machine learning (ML) model for diagnosing and monitoring Parkinson's disease (PD) in an Internet of Things (IoT) environment using rest-state EEG signals (rs-EEG). We computed different types of entropy from EEG signals and found that Fuzzy Entropy performed the best in diagnosing and monitoring PD using rs-EEG. We also investigated different combinations of signal frequency ranges and EEG channels to accurately diagnose PD. Finally, with a fewer number of features (11 features), we achieved a maximum classification accuracy (ARKF) of ~99.9%. The most prominent frequency range of EEG signals has been identified, and we have found that high classification accuracy depends on low-frequency signal components (0-4 Hz). Moreover, the most informative signals were mainly received from the right hemisphere of the head (F8, P8, T8, FC6). Furthermore, we assessed the accuracy of the diagnosis of PD using three different lengths of EEG data (150-1000 samples). Because the computational complexity is reduced by reducing the input data. As a result, we have achieved a maximum mean accuracy of 99.9% for a sample length (LEEG) of 1000 (~7.8 seconds), 98.2% with a LEEG of 800 (~6.2 seconds), and 79.3% for LEEG = 150 (~1.2 seconds). By reducing the number of features and segment lengths, the computational cost of classification can be reduced. Lower-performance smart ML sensors can be used in IoT environments for enhances human resilience to PD.
△ Less
Submitted 28 August, 2023;
originally announced September 2023.
-
Detection of Risk Predictors of COVID-19 Mortality with Classifier Machine Learning Models Operated with Routine Laboratory Biomarkers
Authors:
Mehmet Tahir Huyut,
Andrei Velichko,
Maksim Belyaev
Abstract:
Early evaluation of patients who require special care and who have high death-expectancy in COVID-19, and the effective determination of relevant biomarkers on large sample-groups are important to reduce mortality. This study aimed to reveal the routine blood-value predictors of COVID-19 mortality and to determine the lethal-risk levels of these predictors during the disease process. The dataset o…
▽ More
Early evaluation of patients who require special care and who have high death-expectancy in COVID-19, and the effective determination of relevant biomarkers on large sample-groups are important to reduce mortality. This study aimed to reveal the routine blood-value predictors of COVID-19 mortality and to determine the lethal-risk levels of these predictors during the disease process. The dataset of the study consists of 38 routine blood-values of 2597 patients who died (n = 233) and those who recovered (n = 2364) from COVID-19 in August-December, 2021. In this study, the histogram-based gradient-boosting (HGB) model was the most successful machine-learning classifier in detecting living and deceased COVID-19 patients (with squared F1 metrics F1^2 = 1). The most efficient binary combinations with procalcitonin were obtained with D-dimer, ESR, D-Bil and ferritin. The HGB model operated with these feature pairs correctly detected almost all of the patients who survived and those who died (precision > 0.98, recall > 0.98, F1^2 > 0.98). Furthermore, in the HGB model operated with a single feature, the most efficient features were procalcitonin (F1^2 = 0.96) and ferritin (F1^2 = 0.91). In addition, according to the two-threshold approach, ferritin values between 376.2 mkg/L and 396.0 mkg/L (F1^2 = 0.91) and pro-calcitonin values between 0.2 mkg/L and 5.2 mkg/L (F1^2 = 0.95) were found to be fatal risk levels for COVID-19. Considering all the results, we suggest that many features combined with these features, especially procalcitonin and ferritin, operated with the HGB model, can be used to achieve very successful results in the classification of those who live, and those who die from COVID-19. Moreover, we strongly recommend that clinicians consider the critical levels we have found for procalcitonin and ferritin properties, to reduce the lethality of the COVID-19 disease.
△ Less
Submitted 29 November, 2022; v1 submitted 22 October, 2022;
originally announced October 2022.
-
Machine Learning Sensors for Diagnosis of COVID-19 Disease Using Routine Blood Values for Internet of Things Application
Authors:
Andrei Velichko,
Mehmet Tahir Huyut,
Maksim Belyaev,
Yuriy Izotov,
Dmitry Korzun
Abstract:
Healthcare digitalization requires effective applications of human sensors, when various parameters of the human body are instantly monitored in everyday life due to the Internet of Things (IoT). In particular, machine learning (ML) sensors for the prompt diagnosis of COVID-19 are an important option for IoT application in healthcare and ambient assisted living (AAL). Determining a COVID-19 infect…
▽ More
Healthcare digitalization requires effective applications of human sensors, when various parameters of the human body are instantly monitored in everyday life due to the Internet of Things (IoT). In particular, machine learning (ML) sensors for the prompt diagnosis of COVID-19 are an important option for IoT application in healthcare and ambient assisted living (AAL). Determining a COVID-19 infected status with various diagnostic tests and imaging results is costly and time-consuming. This study provides a fast, reliable and cost-effective alternative tool for the diagnosis of COVID-19 based on the routine blood values (RBVs) measured at admission. The dataset of the study consists of a total of 5296 patients with the same number of negative and positive COVID-19 test results and 51 routine blood values. In this study, 13 popular classifier machine learning models and the LogNNet neural network model were exanimated. The most successful classifier model in terms of time and accuracy in the detection of the disease was the histogram-based gradient boosting (HGB) (accuracy: 100%, time: 6.39 sec). The HGB classifier identified the 11 most important features (LDL, cholesterol, HDL-C, MCHC, triglyceride, amylase, UA, LDH, CK-MB, ALP and MCH) to detect the disease with 100% accuracy. In addition, the importance of single, double and triple combinations of these features in the diagnosis of the disease was discussed. We propose to use these 11 features and their binary combinations as important biomarkers for ML sensors in the diagnosis of the disease, supporting edge computing on Arduino and cloud IoT service.
△ Less
Submitted 20 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Electrical switching and oscillations in vanadium dioxide
Authors:
Alexander Pergament,
Andrei Velichko,
Maksim Belyaev,
Vadim Putrolaynen
Abstract:
We have studied electrical switching with S-shaped I-V characteristics in two-terminal MOM devices based on vanadium dioxide thin films. The switching effect is associated with the metal-insulator phase transition. Relaxation oscillations are observed in circuits with VO2-based switches. Dependences of the oscillator critical frequency Fmax, threshold power and voltage, as well as the time of curr…
▽ More
We have studied electrical switching with S-shaped I-V characteristics in two-terminal MOM devices based on vanadium dioxide thin films. The switching effect is associated with the metal-insulator phase transition. Relaxation oscillations are observed in circuits with VO2-based switches. Dependences of the oscillator critical frequency Fmax, threshold power and voltage, as well as the time of current rise, on the switching structure size are obtained by numerical simulation. The empirical dependence of the threshold voltage on the switching region dimensions and film thickness is found. It is shown that, for the VO2 channel sizes of 10*10 nm, Fmax can reach the value of 300 MHz at a film thickness of ~20 nm. Next, it is shown that oscillatory neural networks can be implemented on the basis of coupled VO2 oscillators. For the weak capacitive coupling, we revealed the dependence of the phase difference upon synchronization on the coupling capacitance value. When the switches are scaled down, the limiting time of synchronization is reduced to Ts ~13 μs, and the number of oscillation periods for the entering to the synchronization mode remains constant, Ns ~ 17. In the case of weak thermal coupling in the synchronization mode, we observe in-phase behavior of oscillators, and there is a certain range of parameters of the supply current, in which the synchronization effect becomes possible. With a decrease in dimensions, a decrease in the thermal coupling action radius is observed, which can vary in the range from 0.5 to 50 μm for structures with characteristic dimensions of 0.1 to 5 μm, respectively. Thermal coupling may have a promising effect for realization of a 3D integrated oscillatory neural network.
△ Less
Submitted 7 January, 2020;
originally announced January 2020.
-
Deep Learning for Brain Tumor Segmentation in Radiosurgery: Prospective Clinical Evaluation
Authors:
Boris Shirokikh,
Alexandra Dalechina,
Alexey Shevtsov,
Egor Krivov,
Valery Kostjuchenko,
Amayak Durgaryan,
Mikhail Galkin,
Ivan Osinov,
Andrey Golanov,
Mikhail Belyaev
Abstract:
Stereotactic radiosurgery is a minimally-invasive treatment option for a large number of patients with intracranial tumors. As part of the therapy treatment, accurate delineation of brain tumors is of great importance. However, slice-by-slice manual segmentation on T1c MRI could be time-consuming (especially for multiple metastases) and subjective. In our work, we compared several deep convolution…
▽ More
Stereotactic radiosurgery is a minimally-invasive treatment option for a large number of patients with intracranial tumors. As part of the therapy treatment, accurate delineation of brain tumors is of great importance. However, slice-by-slice manual segmentation on T1c MRI could be time-consuming (especially for multiple metastases) and subjective. In our work, we compared several deep convolutional networks architectures and training procedures and evaluated the best model in a radiation therapy department for three types of brain tumors: meningiomas, schwannomas and multiple brain metastases. The developed semiautomatic segmentation system accelerates the contouring process by 2.2 times on average and increases inter-rater agreement from 92.0% to 96.5%.
△ Less
Submitted 18 December, 2019; v1 submitted 6 September, 2019;
originally announced September 2019.
-
PICsar: A 2.5D Axisymmetric, Relativistic, Electromagnetic, Particle in Cell Code with a Radiation Absorbing Boundary
Authors:
Mikhail Belyaev
Abstract:
We present PICsar -- a new Particle in Cell code geared towards efficiently simulating the magnetosphere of the aligned rotator. PICsar is a special relativistic, electromagnetic, charge conservative code that can be used to simulate arbitrary electromagnetics problems in axisymmetry. It features stretchable body-fitted coordinates that follow the surface of a sphere, simplifying the application o…
▽ More
We present PICsar -- a new Particle in Cell code geared towards efficiently simulating the magnetosphere of the aligned rotator. PICsar is a special relativistic, electromagnetic, charge conservative code that can be used to simulate arbitrary electromagnetics problems in axisymmetry. It features stretchable body-fitted coordinates that follow the surface of a sphere, simplifying the application of boundary conditions in the case of the aligned rotator; a radiation absorbing outer boundary, which allows a steady state to be set up dynamically and maintained indefinitely from transient initial conditions; and algorithms for injection of charged particles into the simulation domain. The code is parallelized using MPI and scales well to a large number of processors. We discuss the numerical methods used in PICsar and present tests of the code. In particular, we show that PICsar can accurately and efficiently simulate the magnetosphere of the aligned monopole rotator in the force free limit. We present simulations of the aligned dipole rotator in a forthcoming paper.
△ Less
Submitted 1 June, 2016; v1 submitted 7 July, 2014;
originally announced July 2014.
-
A New Way to Conserve Total Energy for Eulerian Hydrodynamic Simulations with Self-Gravity
Authors:
Yan-Fei Jiang,
Mikhail Belyaev,
Jeremy Goodman,
James M. Stone
Abstract:
We propose a new method to conserve the total energy to round-off error in grid-based codes for hydrodynamic simulations with self-gravity. A formula for the energy flux due to the work done by the the self-gravitational force is given, so the change in total energy can be written in conservative form. Numerical experiments with the code Athena show that the total energy is indeed conserved with o…
▽ More
We propose a new method to conserve the total energy to round-off error in grid-based codes for hydrodynamic simulations with self-gravity. A formula for the energy flux due to the work done by the the self-gravitational force is given, so the change in total energy can be written in conservative form. Numerical experiments with the code Athena show that the total energy is indeed conserved with our new algorithm and the new algorithm is second order accurate. We have performed a set of tests that show the numerical errors in the traditional, non-conservative algorithm can affect the dynamics of the system. The new algorithm only requires one extra solution of the Poisson equation, as compared to the traditional algorithm which includes self-gravity as a source term. If the Poisson solver takes a negligible fraction of the total simulation time, such as when FFTs are used, the new algorithm is almost as efficient as the original method. This new algorithm is useful in Eulerian hydrodynamic simulations with self-gravity, especially when results are sensitive to small energy errors, as for radiation pressure dominated flow.
△ Less
Submitted 1 October, 2012; v1 submitted 8 August, 2012;
originally announced August 2012.