-
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
On the features of great Forbush effect during May 2024 extreme geomagnetic storm
Authors:
M. A. Abunina,
N. S. Shlyk,
A. V. Belov,
S. M. Belov,
A. A. Abunin
Abstract:
The work investigates the features of galactic cosmic ray density and anisotropy behavior and their relation to solar sources, interplanetary and geomagnetic disturbances from May 8 to May 13, 2024. During this time, powerful solar flares and fast CMEs were recorded, leading to registration of an extreme geomagnetic storm along with one of the most significant Forbush effects for the entire observ…
▽ More
The work investigates the features of galactic cosmic ray density and anisotropy behavior and their relation to solar sources, interplanetary and geomagnetic disturbances from May 8 to May 13, 2024. During this time, powerful solar flares and fast CMEs were recorded, leading to registration of an extreme geomagnetic storm along with one of the most significant Forbush effects for the entire observation period. All the calculations of cosmic ray characteristics are made using the data of global neutron monitor network and unique methods maintained at IZMIRAN: the Global Survey Method and the Ring of Stations Method. It is determined that the magnitude of Forbush effect under study was 15.7% (for particles with 10 GV rigidity) and as an extreme geomagnetic storm was recorded there was a significant magnetospheric effect observed in the data of neutron monitors (~4%).
△ Less
Submitted 14 January, 2025;
originally announced January 2025.
-
Long term remote reactor power and fuel composition monitoring using antineutrinos
Authors:
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
D. Filosofov,
M. Fomina,
P. Gorovtsov,
Ye. Iusko,
S. Kazartsev,
V. Khvatov,
S. Kiselev,
A. Kobyakin,
A. Krapiva,
A. Kuznetsov,
I. Machikhiliyan,
N. Mashin,
D. Medvedev,
V. Nesterov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik
, et al. (9 additional authors not shown)
Abstract:
Electron antineutrinos are emitted in the decay chains of the fission products inside a reactor core and could be used for remote monitoring of nuclear reactors. The DANSS detector is placed under the core of the 3.1 GW power reactor at the Kalinin Nuclear Power Plant (KNPP) and collects up to 5000 antineutrino events per day. DANSS measured changes of the reactor power by antineutrino counting ra…
▽ More
Electron antineutrinos are emitted in the decay chains of the fission products inside a reactor core and could be used for remote monitoring of nuclear reactors. The DANSS detector is placed under the core of the 3.1 GW power reactor at the Kalinin Nuclear Power Plant (KNPP) and collects up to 5000 antineutrino events per day. DANSS measured changes of the reactor power by antineutrino counting rates over 7 years with 1.0% accuracy in one week periods. The fission fractions of four major isotopes for the reactor power calculations were provided by KNPP. The systematic uncertainty of this measurement is less than 0.8%. It is comparable to the accuracy of conventional methods of the reactor power measurements while it is based on completely different approach. For the first time the 239Pu and 235U fission fractions were reconstructed using antineutrino inverse beta-decay spectrum which is a completely new technique. This method was applied to the data from three reactor fuel campaigns (approximately 1.5 year each). The reconstructed fission fractions in about two-week measurements and the fission fractions provided by KNPP coincide within better than 3% accuracy. This provides confidence in both completely different approaches of the fission fraction determination.
△ Less
Submitted 12 May, 2025; v1 submitted 24 October, 2024;
originally announced October 2024.
-
PET mapping of receptor occupancy using joint direct parametric reconstruction
Authors:
Thibault Marin,
Vasily Belov,
Yanis Chemli,
Jinsong Ouyang,
Yassir Najmaoui,
Georges El Fakhri,
Sridhar Duvvuri,
Philip Iredale,
Nicolas J. Guehl,
Marc D. Normandin,
Yoann Petibon
Abstract:
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconst…
▽ More
Receptor occupancy (RO) studies using PET neuroimaging play a critical role in the development of drugs targeting the central nervous system (CNS). The conventional approach to estimate drug receptor occupancy consists in estimation of binding potential changes between two PET scans (baseline and post-drug injection). This estimation is typically performed separately for each scan by first reconstructing dynamic PET scan data before fitting a kinetic model to time activity curves. This approach fails to properly model the noise in PET measurements, resulting in poor RO estimates, especially in low receptor density regions. Objective: In this work, we evaluate a novel joint direct parametric reconstruction framework to directly estimate distributions of RO and other kinetic parameters in the brain from a pair of baseline and post-drug injection dynamic PET scans. Methods: The proposed method combines the use of regularization on RO maps with alternating optimization to enable estimation of occupancy even in low binding regions. Results: Simulation results demonstrate the quantitative improvement of this method over conventional approaches in terms of accuracy and precision of occupancy. The proposed method is also evaluated in preclinical in-vivo experiments using 11C-MK-6884 and a muscarinic acetylcholine receptor 4 positive allosteric modulator drug, showing improved estimation of receptor occupancy as compared to traditional estimators. Conclusion: The proposed joint direct estimation framework improves RO estimation compared to conventional methods, especially in intermediate to low-binding regions. Significance: This work could potentially facilitate the evaluation of new drug candidates targeting the CNS.
△ Less
Submitted 19 October, 2024;
originally announced October 2024.
-
Nonlinear scintillation effects in the intrinsic luminescence from Sc$_{1.318}$Y$_{0.655}$Si$_{1.013}$O$_{4.987}$ crystal excited by electrons and gamma-quanta
Authors:
M. V. Belov,
V. A. Kozlov,
N. V. Pestovskii,
S. Yu. Savinov,
V. S. Tskhay,
V. I. Vlasov,
A. I. Zagumennyi,
Yu. D. Zavartsev,
M. V. Zavertyaev
Abstract:
The spectral and kinetic properties of intrinsic luminescence from (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ crystal are studied. The emission is excited by electrons and gamma-quanta. The composition (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ is the congruent one for Sc$_2$SiO$_5$-Y$_2$SiO$_5$ solid solutions. It is found, that the crystal emits fairly bright intrinsic cathodololuminescence (CL) and radiolu…
▽ More
The spectral and kinetic properties of intrinsic luminescence from (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ crystal are studied. The emission is excited by electrons and gamma-quanta. The composition (Y$_2$Sc$_1$)$_{0.(3)}$(Sc)[Si]O$_5$ is the congruent one for Sc$_2$SiO$_5$-Y$_2$SiO$_5$ solid solutions. It is found, that the crystal emits fairly bright intrinsic cathodololuminescence (CL) and radioluminescence (RL) at room temperature. In particular, the light yield of scintillation excited by -quanta with the energies of 661.7 keV is of 12000 photons/MeV. An increase in the beam flux by $\sim$20 times leads to the shift in the maximum CL energy spectral density from 315 to 340 nm and to the decrease in the CL decay time at 415 nm from 1377 +/- 3 ns to 1165 +/- 1 ns. Simultaneously, the decay time of RL excited by a photoelectron with the energy of 644.7 keV is of 1310 +/- 10 ns while a Compton electron with the energy of 477 keV excites RL with the decay time of 1050 +/- 10 ns. Also, we observed differences in the CL yield dependencies on the volume-averaged density of electronic excitations (EEs) at different wavelengths. An explanation of the results is given considering the nonlinear scintillation phenomena induced by an interaction between EEs. It is based on a conception that an increase in EE volume density leads to an increase in EEs nonradiative quenching due to these interactions.
△ Less
Submitted 17 August, 2024;
originally announced August 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
Authors:
D. Yu. Akimov,
I. S. Aleksandrov,
F. B. Ata Kurbonova,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
Yu. I. Koskin,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons…
▽ More
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy reconstruction procedures, and evaluation of the efficiency of electron extraction from the liquid xenon to the gas phase.
△ Less
Submitted 31 October, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Study of polysterene based scintillator ageing in the DANSS experiment
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
D. Filosofov,
M. Fomina,
P. Gorovtsov,
Ye. Iusko,
S. Kazartsev,
A. Kobyakin,
A. Krapiva,
A. Kuznetsov,
N. Mashin,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko
, et al. (8 additional authors not shown)
Abstract:
DANSS is a spectrometer of reactor antineutrino based on plastic scintillator. The sensitive volume of the detector is made of 2500 polystyrene based scintillator plates with wavelength shifting (WLS) fiber readout (strips). We present a study of the strips light yield during 6.5 years of DANSS continuous running. Overall ageing at the rate $0.55 \pm 0.05(syst.)$ % per year is observed that is con…
▽ More
DANSS is a spectrometer of reactor antineutrino based on plastic scintillator. The sensitive volume of the detector is made of 2500 polystyrene based scintillator plates with wavelength shifting (WLS) fiber readout (strips). We present a study of the strips light yield during 6.5 years of DANSS continuous running. Overall ageing at the rate $0.55 \pm 0.05(syst.)$ % per year is observed that is considerably smaller than in other similar experiments. We also observe the WLS fiber attenuation length shortening at the rate $0.26 \pm 0.04(stat.)$ % per year.
△ Less
Submitted 23 November, 2023;
originally announced November 2023.
-
Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS
Authors:
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
M. Febbraro,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller,
M. R. Heath,
S. Hedges,
B. A. Johnson
, et al. (55 additional authors not shown)
Abstract:
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We…
▽ More
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant
Authors:
D. Y. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
B. O. Lavrov,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr…
▽ More
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper describes the external background conditions for the RED-100 experiment at Kalinin Nuclear Power Plant.
△ Less
Submitted 24 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (53 additional authors not shown)
Abstract:
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the…
▽ More
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Application of the Duperier method to the analysis of the cosmic muon flux dependence on the meteorological parameters, based on the DANSS detector data
Authors:
I. Alekseev,
V. Belov,
M. Danilov,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova,
D. Svirida,
E. Tarkovsky,
A. Yakovleva,
E. Yakushev,
I. Zhitnikov
, et al. (1 additional authors not shown)
Abstract:
The detector DANSS is located under n industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~ 50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector DANSS is located under an industrial nuclear r…
▽ More
The detector DANSS is located under n industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~ 50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector DANSS is located under an industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector's sensitive area consists of 2500 plastic scintillator counters, each 100x4x1 cm$^3$ in size, making in total a 1 m$^3$ volume, which is surrounded by a muon veto system and multiple layers of passive shielding. The main goal of the DANSS experiment is to study the antineutrino spectra at different distances from the source. For this purpose the detector is placed on a lifting platform, and the data is collected at three positions: 10.9 m, 11.9 m and 12.9 m from the center of the reactor core. The detector is capable of reconstructing muon tracks passing though the sensitive volume. In this work the barometric, height and temperature correlation coefficients are calculated in three areas of the zenith angle $θ$ using the Duperier approach. These results are based on the muon data collected during four years.
△ Less
Submitted 10 July, 2023;
originally announced July 2023.
-
Luminescence from oxygen vacancies in Lu$_{2}$SiO$_{5}$ crystal and ceramics at room temperature
Authors:
M. V. Belov,
S. A. Koutovoi,
V. A. Kozlov,
N. V. Pestovskii,
S. Yu. Savinov,
A. I. Zagumennyi,
Yu. D. Zavartsev,
M. V. Zavertyaev
Abstract:
Photoluminescence (PL) of Lu$_{2}$SiO$_{5}$ crystal and ceramics with a high concentration of oxygen vacancies (about ~0.5 at.%) is studied. Oxygen vacancies were created using two ways. The first method is a growth of crystal from the non-stoichiometric Lu$_{2}$Si$_{0.98}$O$_{4.96}$ melt and the second one is a doping of Lu$_{2}$SiO$_{5}$ matrix with divalent Ca$^{2+}$ ions at the concentration o…
▽ More
Photoluminescence (PL) of Lu$_{2}$SiO$_{5}$ crystal and ceramics with a high concentration of oxygen vacancies (about ~0.5 at.%) is studied. Oxygen vacancies were created using two ways. The first method is a growth of crystal from the non-stoichiometric Lu$_{2}$Si$_{0.98}$O$_{4.96}$ melt and the second one is a doping of Lu$_{2}$SiO$_{5}$ matrix with divalent Ca$^{2+}$ ions at the concentration of 1 at.%. For the first time we observe a fairly bright room-temperature ultraviolet PL of both crystal grown from the Lu$_{2}$Si$_{0.98}$O$_{4.96}$ melt and Lu$_{2}$SiO$_{5}$ ceramics doped with Ca$^{2+}$ ions. A band at 290 nm in the PL spectrum of the crystal and a band at 283 nm in the PL spectrum of the calcium-doped ceramics are observed. The spectral and kinetic properties of these bands are close to each other. This fact indicates similar origins of these bands. The results of the work show that the studied ultraviolet luminescence is related to oxygen vacancies in lutetium oxyorthosilicate.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Results from a Prototype TES Detector for the Ricochet Experiment
Authors:
Ricochet Collaboration,
C. Augier,
G. Baulieu,
V. Belov,
L. Bergé,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chala,
C. L. Chang,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
E. Cudmore,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol
, et al. (66 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of…
▽ More
Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.
△ Less
Submitted 12 January, 2024; v1 submitted 28 April, 2023;
originally announced April 2023.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
Authors:
S. Li,
I. Ostrovskiy,
Z. Li,
L. Yang,
S. Al Kharusi,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian
, et al. (65 additional authors not shown)
Abstract:
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial N…
▽ More
Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.
△ Less
Submitted 8 May, 2023; v1 submitted 11 March, 2023;
originally announced March 2023.
-
The RED-100 experiment
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
R. R. Alyev,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
E. M. Glagovsky,
Y. V. Gusakov,
A. V. Khromov,
S. M. Kiselev,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des…
▽ More
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is described. There is no correlation of the radioactive background at the experimental setup site with ON and OFF states of the reactor. The data taking run was carried out at the beginning of the year 2022 and covered both the reactor OFF and ON periods.
△ Less
Submitted 14 November, 2022; v1 submitted 30 September, 2022;
originally announced September 2022.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor
Authors:
C. Augier,
G. Baulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J. -L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. -B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (58 additional authors not shown)
Abstract:
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW resear…
▽ More
The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment's shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $^3$He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance.
△ Less
Submitted 2 August, 2022;
originally announced August 2022.
-
The COHERENT Experimental Program
Authors:
D. Akimov,
S. Alawabdeh,
P. An,
A. Arteaga,
C. Awe,
P. S. Barbeau,
C. Barry,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
C. Bock,
B. Bodur,
A. Bolozdynya,
R. Bouabid,
A. Bracho,
J. Browning,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Daughtry,
E. Day
, et al. (106 additional authors not shown)
Abstract:
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o…
▽ More
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
Optimized scintillation strip design for the DANSS upgrade
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
A. Ershova,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
N. Kozlenko,
A. Kuznetsov,
I. Machikhiliyan,
F. Mamedov,
D. Medvedev,
V. Nesterov,
D. Novinsky,
K. Perminov,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko
, et al. (10 additional authors not shown)
Abstract:
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile…
▽ More
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile neutrino exclusion regions. Yet a moderate energy resolution of the detector prevents the further progress in the physics program. The main challenge of the planned upgrade is to achieve the energy resolution of 12% at 1 MeV. The new design of the main sensitive element - the plastic scintillation strip - is the most important step forward. The strip prototypes were manufactured and tested at the pion beam of the PNPI synchrocyclotron. More than twice higher light output together with fairly flat detector response uniformity, longitudinal timing information and other optimizations will surely help to reach the upgrade goal. The paper discusses the drawbacks of the current strip version, outlines the new features of the proposed upgrade, describes the beam test procedure and presents the test results reflecting the advantages of the new strip design in comparison with the currently used version.
△ Less
Submitted 13 April, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.
-
Observation of the temperature and barometric effects on the cosmic muon flux by the DANSS detector
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
V. Brudanin,
A. Bystryakov,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova,
A. Starostin,
D. Svirida
, et al. (4 additional authors not shown)
Abstract:
The DANSS detector is located directly below a commercial reactor core at the Kalinin Nuclear Power Plant. Such a position provides an overburden about 50 m.w.e. in vertical direction. In terms of the cosmic rays it occupies an intermediate position between surface and underground detectors. The sensitive volume of the detector is a cubic meter of plastic scintillator with fine segmentation and co…
▽ More
The DANSS detector is located directly below a commercial reactor core at the Kalinin Nuclear Power Plant. Such a position provides an overburden about 50 m.w.e. in vertical direction. In terms of the cosmic rays it occupies an intermediate position between surface and underground detectors. The sensitive volume of the detector is a cubic meter of plastic scintillator with fine segmentation and combined PMT and SiPM readout, surrounded by multilayer passive and active shielding. The detector can reconstruct muon tracks passing through its sensitive volume. The main physics goal of the DANSS experiment implies the antineutrino spectra measurements at various distances from the source. This is achieved by means of a lifting platform so that the data is taken in three positions - 10.9, 11.9 and 12.9 meters from the reactor core. The muon data were collected for nearly four calendar years. The overburden parameters $\langle E_{thr}\cosθ\rangle$ and $\langle E_{thr} \rangle$, as well as the temperature and barometric correlation coefficients are evaluated separately for the three detector positions and, in each position, in three ranges of the zenith angle - for nearly vertical muons with $\cosθ>0.9$, for nearly horizontal muons with $\cosθ<0.36$, and for the whole upper hemisphere.
△ Less
Submitted 30 May, 2022; v1 submitted 7 December, 2021;
originally announced December 2021.
-
Monitoring the SNS basement neutron background with the MARS detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (53 additional authors not shown)
Abstract:
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the…
▽ More
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.
△ Less
Submitted 14 April, 2022; v1 submitted 5 December, 2021;
originally announced December 2021.
-
Ricochet Progress and Status
Authors:
Ricochet Collaboration,
G. Beaulieu,
V. Belov,
L. Berge,
J. Billard,
G. Bres,
J-. L. Bret,
A. Broniatowski,
M. Calvo,
A. Cazes,
D. Chaize,
M. Chapellier,
L. Chaplinsky,
G. Chemin,
R. Chen,
J. Colas,
M. De Jesus,
P. de Marcillac,
L. Dumoulin,
O. Exshaw,
S. Ferriol,
E. Figueroa-Feliciano,
J. B. Filippini,
J. A. Formaggio,
S. Fuard
, et al. (55 additional authors not shown)
Abstract:
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array dete…
▽ More
We present an overview of recent progress towards the Ricochet coherent elastic neutrino nucleus scattering CE$ν$NS experiment. The ILL research reactor in Grenoble, France has been selected as the experiment site, after in situ studies of vibration and particle backgrounds. We present background rate estimates specific to that site, along with descriptions of the planned CryoCube and Q-Array detector payloads.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (52 additional authors not shown)
Abstract:
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at t…
▽ More
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
△ Less
Submitted 6 October, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
E. Day,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (54 additional authors not shown)
Abstract:
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncerta…
▽ More
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.
△ Less
Submitted 25 August, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Radial Evolution of the April 2020 Stealth Coronal Mass Ejection between 0.8 and 1 AU -- A Comparison of Forbush Decreases at Solar Orbiter and Earth
Authors:
Johan L. Freiherr von Forstner,
Mateja Dumbović,
Christian Möstl,
Jingnan Guo,
Athanasios Papaioannou,
Robert Elftmann,
Zigong Xu,
Jan Christoph Terasa,
Alexander Kollhoff,
Robert F. Wimmer-Schweingruber,
Javier Rodríguez-Pacheco,
Andreas J. Weiss,
Jürgen Hinterreiter,
Tanja Amerstorfer,
Maike Bauer,
Anatoly V. Belov,
Maria A. Abunina,
Timothy Horbury,
Emma E. Davies,
Helen O'Brien,
Robert C. Allen,
G. Bruce Andrews,
Lars Berger,
Sebastian Boden,
Ignacio Cernuda Cangas
, et al. (18 additional authors not shown)
Abstract:
Aims. We present observations of the first coronal mass ejection (CME) observed at the Solar Orbiter spacecraft on April 19, 2020, and the associated Forbush decrease (FD) measured by its High Energy Telescope (HET). This CME is a multispacecraft event also seen near Earth the next day. Methods. We highlight the capabilities of HET for observing small short-term variations of the galactic cosmic r…
▽ More
Aims. We present observations of the first coronal mass ejection (CME) observed at the Solar Orbiter spacecraft on April 19, 2020, and the associated Forbush decrease (FD) measured by its High Energy Telescope (HET). This CME is a multispacecraft event also seen near Earth the next day. Methods. We highlight the capabilities of HET for observing small short-term variations of the galactic cosmic ray count rate using its single detector counters. The analytical ForbMod model is applied to the FD measurements to reproduce the Forbush decrease at both locations. Input parameters for the model are derived from both in situ and remote-sensing observations of the CME. Results. The very slow (~350 km/s) stealth CME caused a FD with an amplitude of 3 % in the low-energy cosmic ray measurements at HET and 2 % in a comparable channel of the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) on the Lunar Reconnaissance Orbiter, as well as a 1 % decrease in neutron monitor measurements. Significant differences are observed in the expansion behavior of the CME at different locations, which may be related to influence of the following high speed solar wind stream. Under certain assumptions, ForbMod is able to reproduce the observed FDs in low-energy cosmic ray measurements from HET as well as CRaTER, but with the same input parameters, the results do not agree with the FD amplitudes at higher energies measured by neutron monitors on Earth. We study these discrepancies and provide possible explanations. Conclusions. This study highlights that the novel measurements of the Solar Orbiter can be coordinated with other spacecraft to improve our understanding of space weather in the inner heliosphere. Multi-spacecraft observations combined with data-based modeling are also essential to understand the propagation and evolution of CMEs as well as their space weather impacts.
△ Less
Submitted 24 February, 2021;
originally announced February 2021.
-
Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr i…
▽ More
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV
△ Less
Submitted 27 January, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Peculiar solar sources and geospace disturbances on 20-26 August 2018
Authors:
A. A. Abunin,
M. A. Abunina,
A. V. Belov,
I. M. Chertok
Abstract:
On the approach to minimum of Solar Cycle 24, on 26 August 2018, an unexpectedly strong geomagnetic storm (GMS) suddenly occurred. Its Dst index reached -174 nT, that is the third of the most intense storms during the cycle. The analysis showed that it was initiated by a two-step long filament eruption, which occurred on 20 August in the central sector of the solar disk. The eruptions were accompa…
▽ More
On the approach to minimum of Solar Cycle 24, on 26 August 2018, an unexpectedly strong geomagnetic storm (GMS) suddenly occurred. Its Dst index reached -174 nT, that is the third of the most intense storms during the cycle. The analysis showed that it was initiated by a two-step long filament eruption, which occurred on 20 August in the central sector of the solar disk. The eruptions were accompanied by two large-scale divergent ribbons and dimmings of a considerable size and were followed by relatively weak but evident Earth-directed coronal mass ejections. In the inner corona, their estimated speed was very low of about 200-360 km/s. The respective interplanetary transients apparently propagated between two high-speed solar wind streams originated from a two-component coronal hole and therefore their expansion was limited. The resulting ejecta arrived at the Earth only on 25 August and brought an unexpectedly strong field of Bt ~ 18.2 nT with a predominantly negative Bz component of almost the same strength. The geospace storm also manifested itself in the form of a peculiar Forbush decrease (FD). Its magnitude was about 1.5%, which is rather small for the observed G3-class GMS. The main unusual feature of the event is that large positive bursts with an enhancement up to 3% above the pre-event level were recorded on the FD background. We argue that these bursts were mainly caused by an unusually large and changeable cosmic ray anisotropy combined with lowering of the geomagnetic cutoff rigidity in the perturbed Earth's magnetosphere under conditions of the cycle minimum.
△ Less
Submitted 17 December, 2019;
originally announced December 2019.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri,
M. P. Green,
K. S. Hansen
, et al. (53 additional authors not shown)
Abstract:
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitu…
▽ More
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
First ground-level laboratory test of the two-phase xenon emission detector RED-100
Authors:
D. Yu. Akimov,
V. A. Belov,
A. I. Bolozdynya,
Yu. V. Efremenko,
A. V. Etenko,
A. V. Galavanov,
D. V. Gouss,
Yu. V. Gusakov,
Dj. Ed. Kdib,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
Yu. A. Melikyan,
V. V. Moramzin,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
Yu. V. Stogov,
A. A. Vasin
Abstract:
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats…
▽ More
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamatsu R11410-20 PMTs assembled in two planes on top and bottom. The electrode system is equipped with an electron shutter (a patented device) to reduce a "spontaneous" single-electron noise. The detector was tested in a ground-level laboratory. The obtained results demonstrate that detection of coherent elastic scattering of reactor antineutrinos off xenon nuclei at Kalinin nuclear power plant with the RED-100 detector is feasible with a threshold of 4 ionization electrons.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.
-
Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
Authors:
EXO-200 Collaboration,
:,
G. Anton,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
T. Daniels,
L. Darroch,
S. J. Daugherty,
J. Davis,
S. Delaquis,
A. Der Mesrobian-Kabakian,
R. DeVoe,
J. Dilling,
A. Dolgolenko
, et al. (78 additional authors not shown)
Abstract:
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the…
▽ More
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.
△ Less
Submitted 15 June, 2020; v1 submitted 12 August, 2019;
originally announced August 2019.
-
Simulation of charge readout with segmented tiles in nEXO
Authors:
Z. Li,
W. R. Cen,
A. Robinson,
D. C. Moore,
L. J. Wen,
A. Odian,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland
, et al. (128 additional authors not shown)
Abstract:
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neu…
▽ More
nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0νββ$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated $0νββ$ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the $0νββ$ signal from backgrounds. The estimated half-life sensitivity for $0νββ$ decay is improved by $\sim$20$~(32)\%$ with the multi-variate~(deep neural network) methods considered here, relative to the sensitivity estimated in the nEXO pre-conceptual design report.
△ Less
Submitted 11 October, 2019; v1 submitted 17 July, 2019;
originally announced July 2019.
-
Fast component re-emission in Xe-doped liquid argon
Authors:
D. Akimov,
V. Belov,
A. Konovalov,
A. Kumpan,
O. Razuvaeva,
D. Rudik,
G. Simakov
Abstract:
We present the first direct experimental confirmation of the fast component re-emission in liquid argon (LAr) doped with xenon (Xe). This effect was studied at various Xe concentrations up to $\sim$3000 ppm. The rate constant of energy transfer for the fast component was quantified. It was shown that LAr doped with a high concentration of Xe without TPB has a better PSD efficiency than pure LAr or…
▽ More
We present the first direct experimental confirmation of the fast component re-emission in liquid argon (LAr) doped with xenon (Xe). This effect was studied at various Xe concentrations up to $\sim$3000 ppm. The rate constant of energy transfer for the fast component was quantified. It was shown that LAr doped with a high concentration of Xe without TPB has a better PSD efficiency than pure LAr or Xe-doped LAr with TPB. The stability of LAr+Xe mixture was tested for the first time at high Xe concentration for long continuous runtimes.
△ Less
Submitted 21 September, 2019; v1 submitted 3 June, 2019;
originally announced June 2019.
-
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Authors:
G. Gallina,
P. Giampa,
F. Retiere,
J. Kroeger,
G. Zhang,
M. Ward,
P. Margetak,
G. Lic,
T. Tsang,
L. Doria,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
J. P. Brodsky,
E. Brown,
T. Brunner,
G. F. Cao,
L. Cao
, et al. (126 additional authors not shown)
Abstract:
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency…
▽ More
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
△ Less
Submitted 7 June, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Study of Silicon Photomultiplier Performance in External Electric Fields
Authors:
X. L. Sun,
T. Tolba,
G. F. Cao,
P. Lv,
L. J. Wen,
A. Odian,
F. Vachon,
A. Alamre,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois
, et al. (127 additional authors not shown)
Abstract:
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estima…
▽ More
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.
△ Less
Submitted 9 July, 2018;
originally announced July 2018.
-
Imaging individual barium atoms in solid xenon for barium tagging in nEXO
Authors:
C. Chambers,
T. Walton,
D. Fairbank,
A. Craycraft,
D. R. Yahne,
J. Todd,
A. Iverson,
W. Fairbank,
A. Alamare,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen
, et al. (126 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a…
▽ More
The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or 'tagging', of the $^{136}$Ba daughter atom from double beta decay of $^{136}$Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for $\sim$30~s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of $\leq$0.16\%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.
△ Less
Submitted 12 December, 2018; v1 submitted 27 June, 2018;
originally announced June 2018.
-
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
Authors:
A. Jamil,
T. Ziegler,
P. Hufschmidt,
G. Li,
L. Lupin-Jimenez,
T. Michel,
I. Ostrovskiy,
F. Retière,
J. Schneider,
M. Wagenpfeil,
J. B. Albert,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. Barbeau,
D. Beck,
V. Belov,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers
, et al. (118 additional authors not shown)
Abstract:
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting t…
▽ More
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area avalanche photodiodes. The next generation double beta decay experiment, nEXO, with a 5 tonne liquid xenon time projection chamber, will use SiPMs for detecting the $178\,\text{nm}$ xenon scintillation light, in order to achieve an energy resolution of $σ/ Q_{ββ} = 1\, \%$. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler in two complementary setups. It includes measurements of the photon detection efficiency with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. We report improved photon detection efficiency at $175\,\text{nm}$ compared to previous generation devices, that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.
△ Less
Submitted 13 March, 2019; v1 submitted 6 June, 2018;
originally announced June 2018.
-
nEXO Pre-Conceptual Design Report
Authors:
nEXO Collaboration,
S. Al Kharusi,
A. Alamre,
J. B. Albert,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
F. Bourque,
J. P. Brodsky,
E. Brown,
T. Brunner,
A. Burenkov,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
R. Conley
, et al. (149 additional authors not shown)
Abstract:
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of app…
▽ More
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0νββ$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0νββ$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed.
This design for nEXO presents a compelling path towards a next generation search for $0νββ$, with a substantial possibility to discover physics beyond the Standard Model.
△ Less
Submitted 13 August, 2018; v1 submitted 28 May, 2018;
originally announced May 2018.
-
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
Authors:
S. Delaquis,
M. J. Jewell,
I. Ostrovskiy,
M. Weber,
T. Ziegler,
J. Dalmasson,
L. J. Kaufman,
T. Richards,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree,
T. Daniels
, et al. (69 additional authors not shown)
Abstract:
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what…
▽ More
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.
△ Less
Submitted 30 August, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.
-
Search for sterile neutrinos at the DANSS experiment
Authors:
I. Alekseev,
V. Belov,
V. Brudanin,
M. Danilov,
V. Egorov,
D. Filosofov,
M. Fomina,
Z. Hons,
S. Kazartsev,
A. Kobyakin,
A. Kuznetsov,
I. Machikhiliyan,
D. Medvedev,
V. Nesterov,
A. Olshevsky,
N. Pogorelov,
D. Ponomarev,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko,
Yu. Shitov,
N. Skrobova
, et al. (6 additional authors not shown)
Abstract:
DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-e…
▽ More
DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-equivalent shielding against the cosmic background. DANSS detects almost 5000 $\widetildeν_e$ per day at the closest position with the cosmic background less than 3$\%$. The inverse beta decay process is used to detect $\widetildeν_e$. Sterile neutrinos are searched for assuming the $4ν$ model (3 active and 1 sterile $ν$). The exclusion area in the $Δm_{14}^2,\sin^22θ_{14}$ plane is obtained using a ratio of positron energy spectra collected at different distances. Therefore results do not depend on the shape and normalization of the reactor $\widetildeν_e$ spectrum, as well as on the detector efficiency. Results are based on 966 thousand antineutrino events collected at 3 distances from the reactor core. The excluded area covers a wide range of the sterile neutrino parameters up to $\sin^22θ_{14}<0.01$ in the most sensitive region.
△ Less
Submitted 14 November, 2018; v1 submitted 11 April, 2018;
originally announced April 2018.