-
Precision Measurement of the Radiative $\Beta$ Decay of the Free Neutron
Authors:
M. J. Bales,
R. Alarcon,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
R. L. Cooper,
M. S. Dewey,
S. Gardner,
T. R. Gentile,
D. He,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was…
▽ More
The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the $β$ decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14~keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062 [syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.
△ Less
Submitted 26 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
Development and Characterization of a High Sensitivity Segmented Fast Neutron Spectrometer (FaNS-2)
Authors:
FaNS Collaboration,
T. J. Langford,
E. J. Beise,
H. Breuer,
C. R. Heimbach,
G. Ji,
J. S. Nico
Abstract:
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator…
▽ More
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to identify neutron events and reject backgrounds. Neutrons deposit energy in the plastic scintillator before capturing on a $^3$He nucleus in the proportional counters. Segmentation improves neutron energy reconstruction while the large volume of scintillator increases sensitivity to low neutron fluxes. A main goal of its design is to study comparatively low neutron fluxes, such as cosmogenic neutrons at the Earth's surface, in an underground environment, or from low-activity neutron sources. In this paper, we present details of its design and construction as well as its characterization with a calibrated $^{252}$Cf source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected monoenergetic neutron spectra are unfolded using a Singular Value Decomposition method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss plans for measuring the surface and underground cosmogenic neutron spectra with FaNS-2.
△ Less
Submitted 26 October, 2015;
originally announced October 2015.
-
Fast Neutron Detection with a Segmented Spectrometer
Authors:
T. J. Langford,
C. D. Bass,
E. J. Beise,
H. Breuer,
D. K. Erwin,
C. R. Heimbach,
J. S. Nico
Abstract:
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintill…
▽ More
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulseshape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130 deg. N, 77.218 deg. W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.
△ Less
Submitted 20 November, 2014; v1 submitted 24 July, 2014;
originally announced July 2014.
-
Event Identification in $^3$He Proportional Counters Using Risetime Discrimination
Authors:
T. J. Langford,
C. D. Bass,
E. J. Beise,
H. Breuer,
D. K. Erwin,
C. R. Heimbach,
J. S. Nico
Abstract:
We present a straightforward method for particle identification and background rejection in $^3$He proportional counters for use in neutron detection. By measuring the risetime and pulse height of the preamplifier signals, one may define a region in the risetime versus pulse height space where the events are predominately from neutron interactions. For six proportional counters surveyed in a low-b…
▽ More
We present a straightforward method for particle identification and background rejection in $^3$He proportional counters for use in neutron detection. By measuring the risetime and pulse height of the preamplifier signals, one may define a region in the risetime versus pulse height space where the events are predominately from neutron interactions. For six proportional counters surveyed in a low-background environment, we demonstrate the ability to reject alpha-particle events with an efficiency of 99%. By applying the same method, we also show an effective rejection of microdischarge noise events that, when passed through a shaping amplifier, are indistinguishable from physical events in the counters. The primary application of this method is in measurements where the signal-to-background for counting neutrons is very low, such as in underground laboratories.
△ Less
Submitted 19 December, 2012;
originally announced December 2012.
-
A gamma- and X-ray detector for cryogenic, high magnetic field applications
Authors:
R. L. Cooper,
R. Alarcon,
M. J. Bales,
C. D. Bass,
E. J. Beise,
H. Breuer,
J. Byrne,
T. E. Chupp,
K. J. Coakley,
M. S. Dewey,
C. Fu,
T. R. Gentile,
H. P. Mumm,
J. S. Nico,
B. O'Neill,
K. Pulliam,
A. K. Thompson,
F. E. Wietfeldt
Abstract:
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarg…
▽ More
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector is presented, as well as information on operation of APDs at cryogenic temperatures.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.
-
Characterization of a Li-6 loaded liquid organic scintillator for fast neutron spectrometry and thermal neutron detection
Authors:
C. D. Bass,
E. J. Beise,
H. Breuer,
C. R. Heimbach,
T. Langford,
J. S. Nico
Abstract:
The characterization of a liquid scintillator incorporating an aqueous solution of enriched lithium chloride to produce a scintillator with 0.40% Li-6 is presented, including the performance of the scintillator in terms of its optical properties and neutron response. The scintillator was incorporated into a fast neutron spectrometer, and the light output spectra from 2.5 MeV, 14.1 MeV, and Cf-252…
▽ More
The characterization of a liquid scintillator incorporating an aqueous solution of enriched lithium chloride to produce a scintillator with 0.40% Li-6 is presented, including the performance of the scintillator in terms of its optical properties and neutron response. The scintillator was incorporated into a fast neutron spectrometer, and the light output spectra from 2.5 MeV, 14.1 MeV, and Cf-252 neutrons were measured using capture-gated coincidence techniques. The spectrometer was operated without coincidence to perform thermal neutron measurements. Possible improvements in spectrometer performance are discussed.
△ Less
Submitted 7 February, 2013; v1 submitted 18 June, 2012;
originally announced June 2012.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.