-
Study of neutron response using time of flight technique in ISMRAN detector
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We report the measurements of the fast neutron energy response in Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector consisting of an array of 9$\times$10 Plastic Scintillator Bars (PSBs) at BARC, Mumbai. ISMRAN is an above ground detector setup at $\sim$13 m from the Dhruva reactor core for the detection of reactor anti-neutrinos (${\overline{\ensuremathν}}_{e}$) via the inve…
▽ More
We report the measurements of the fast neutron energy response in Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector consisting of an array of 9$\times$10 Plastic Scintillator Bars (PSBs) at BARC, Mumbai. ISMRAN is an above ground detector setup at $\sim$13 m from the Dhruva reactor core for the detection of reactor anti-neutrinos (${\overline{\ensuremathν}}_{e}$) via the inverse beta decay (IBD) process. The dominant sources of reactor-related background in the vicinity of the detector are high energy $γ$-rays and fast neutrons. Therefore, a good understanding of fast neutron response in PSB is an essential pre-requisite for suppression and discrimination of the fast neutron background from IBD events. Kinetic energies of the fast neutron were determined using the Time-of-Flight (TOF) technique, which is used to get the scintillation light yield due to recoiling proton in PSB. We also measured the fast neutron capture time distribution in ISMRAN array using a novel technique involving TOF of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with GEANT4 based MC simulation. These experimentally measured results will be useful for discriminating correlated and uncorrelated (accidental) background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 15 June, 2025;
originally announced June 2025.
-
Discrimination of neutron-$γ$ in the low energy regime using machine learning for an EJ-276D plastic scintillator
Authors:
S. Panda,
P. K. Netrakanti,
S. P. Behera,
R. R. Sahu,
K. Kumar,
R. Sehgal,
D. K. Mishra,
V. Jha
Abstract:
In this work, we present results for discrimination of neutron and $γ$ events using a plastic scintillator detector with pulse shape discrimination capabilities. Machine learning (ML) algorithms are used to improve the discriminatory power between neutron and $γ$ events at lower energy ranges which otherwise are not addressed by the conventional pulse shape discrimination techniques. The use of a…
▽ More
In this work, we present results for discrimination of neutron and $γ$ events using a plastic scintillator detector with pulse shape discrimination capabilities. Machine learning (ML) algorithms are used to improve the discriminatory power between neutron and $γ$ events at lower energy ranges which otherwise are not addressed by the conventional pulse shape discrimination techniques. The use of a multilayer perceptron with Bayesian inference (MLPBNN) and support vector machine (SVM) algorithms are studied using the recorded waveforms from the detector. Three variables are constructed for the input of ML algorithms, which captures the essence of the differences in the head and tail part of the neutron and $γ$ waveforms. The training and the testing of the ML algorithms are done using an AmBe neutron source. In the lower energy region, the results obtained from the ML predictions are compared with the results obtained from a time of flight (ToF) technique to benchmark the overall performance of the ML algorithms. A reasonable agreement is observed between the results obtained from ML algorithm and the ToF experiment in the studied energy range. The MLPBNN gives better discriminatory power for the neutron and $γ$ events than the SVM algorithm.
△ Less
Submitted 13 June, 2025;
originally announced June 2025.
-
Measurement of cosmic muon-induced neutron background with ISMRAN detector in a non-reactor environment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai, India. The primary goal of the ISMRAN experiment is the indirect detection of reactor ${\overline{\ensuremathν}}_{e}$ through an inverse beta decay (IBD) process, u…
▽ More
The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai, India. The primary goal of the ISMRAN experiment is the indirect detection of reactor ${\overline{\ensuremathν}}_{e}$ through an inverse beta decay (IBD) process, using a cluster of 90 optically segmented plastic scintillator detectors, weighing $\sim$1 ton. In this work, we present the neutron capture time response and energy deposition of neutron capture signals generated by cosmic muons in the ISMRAN geometry, and we compare these experimental results with Geant4-based Monte Carlo (MC) simulations. The obtained mean capture time of fast neutrons is 74.46 $\pm$ 5.98 $\mathrmμ$s and is comparable with the MC simulation results. The efficiency-corrected rate of muon-induced neutron background inside the ISMRAN geometry, due to the presence of a passive shielding structure of 10 cm lead followed by 10 cm borated polyethylene with a surface area of 600 $\mathrm{cm^{2}}$, deployed on top of the ISMRAN setup, is reported to be 1334 $\pm$ 64 (stat.) $\pm$ 70 (sys.) per day. This result shows good agreement with the expected background rate from MC simulations using Geant4. We also estimate the muon-induced fast-neutron rate in the ISMRAN geometry for the actual shielding configuration of 9000 $\mathrm{cm^{2}}$ surface area to be 3335 $\pm$ 160 (stat.) $\pm$ 175 (sys.) neutrons $\mathrm{day^{-1}}$ through an extrapolation, after incorporating the model dependent acceptance correction factor from the Geant4 MC simulation. Finally, using these results, we evaluate the neutron production yield due to the composite shielding in the ISMRAN geometry, which is 2.81$\times$$\mathrm{10^{-5}}$ neutrons per $μ$ per (g/$\mathrm{cm^{2}}$) at sea level.
△ Less
Submitted 23 March, 2025;
originally announced March 2025.
-
Background measurements and detector response studies for ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) ex…
▽ More
We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) experiment at very short baseline located at Dhruva research reactor facility. It is enclosed by a shielding made of 10 cm thick lead and 10 cm thick borated polyethylene to minimize the backgrounds and is mounted on a movable base structure, situated at $\sim$ 13 m away from the reactor core. These measurements are useful in the context of the ISMRAN detector setup that will be used to detect the reactor $\mathrm{\overlineν_{e}}$ and measure its energy spectrum through the inverse beta decay (IBD) process. In this paper, we present the energy resolution model and energy non-linearity model of PSB and the cosmogenic muon-induced background, based on the sum of their energy depositions and number of hit bars. Reconstructed sum energy spectrum and number of hit bars distribution for $\mathrm{{}^{22}Na}$ radioactive source has been compared with Geant4 based Monte Carlo simulations. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 11 January, 2023; v1 submitted 27 November, 2022;
originally announced November 2022.
-
Evaluation of the response of plastic scintillator bars and measurement of neutron capture time in non-reactor environment for the ISMRAN experiment
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
R. Sehgal,
V. Jha,
L. M. Pant
Abstract:
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will b…
▽ More
We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will be used to detect the reactor anti-neutrinos (${\bar{\ensuremathν}}_{e}$) and measure its energy spectra, through the inverse beta decay (IBD) process. A GEANT4 based Monte Carlo (MC) simulation is used to understand the optical transmission, energy resolution and energy non-linearity of the ISMRAN detector. A detailed analysis procedure has been developed to understand the natural radioactive, cosmogenic and cosmic muon-induced backgrounds with the ISMRAN detector setup in a non-reactor environment, based on their energy deposition, number of bars hit as well as topological event selection criteria in position and time for triggered events. Data and MC simulated distributions of reconstructed sum energy and number of bars hit has been compared for the radioactive $γ$ + positron source such as $\mathrm{{}^{22}Na}$ placed at the center of the ISMRAN array. Fast neutron energy response and capture time distribution in ISMRAN array has been studied using a novel technique involving Time of Flight (TOF) of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with $\sim$65 $μ$s obtained from MC simulation. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection
Authors:
P. K. Netrakanti,
D. Mulmule,
D. K. Mishra,
S. P. Behera,
R. Dey,
R. Sehgal,
S. K. Sinha,
V. Jha,
L. M. Pant
Abstract:
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy d…
▽ More
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.
△ Less
Submitted 28 December, 2021; v1 submitted 24 December, 2021;
originally announced December 2021.
-
Cosmic ray measurements using the ISMRAN setup in a non-reactor environment
Authors:
S. P. Behera,
R. Sehgal,
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
V. Jha,
L. M. Pant
Abstract:
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muo…
▽ More
The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muons has been measured and compared with Monte Carlo expectations. The detector setup was further used to measure the lifetime distribution of stopped muons and extract their rates inside the detector matrix. The measured spectra of decaying muons and associated electrons show a good agreement with the MC simulations performed through GEANT4 simulation.
△ Less
Submitted 2 June, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
D. Mulmule,
T. Patel,
P. S. Sarkar,
V. Jha,
L. M. Pant
Abstract:
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse…
▽ More
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.
△ Less
Submitted 4 November, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.
-
Active-sterile neutrino mixing constraint using reactor antineutrinos with the ISMRAN set-up
Authors:
S. P. Behera,
D. K. Mishra,
L. M. Pant
Abstract:
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near a…
▽ More
In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near and far positions from the given reactor core. Results extracted in the later case are independent of the theoretical prediction of the reactor anti-neutrino spectrum and detector related systematic uncertainties. Our analysis shows that the results obtained from the measurement carried out at a combination of the near and far detector positions are improved significantly at higher $Δm^{2}_{41}$ compared to the ones obtained with the measurement at a single detector position only. It is found that the best possible combination of near and far detector positions from a 100 MW$_{th}$ power DHRUVA research reactor core are 7 m and 9 m, respectively, for which ISMRAN set-up can exclude in the range 1.4 $eV^{2} \leq Δm^{2}_{41} \leq$ 4.0 $eV^{2}$ of reactor antineutrino anomaly region along with the present best-fit point of active-sterile neutrino oscillation parameters. At those combinations of detector positions, the ISMRAN set-up can observe the active sterile neutrino oscillation with a 95$\%$ confidence level provided that $\sin^{2}2θ_{14}\geq 0.09$ at $Δm^{2}_{41}$ = 1 eV$^{2}$ for an exposure of 1 ton-yr. The active-sterile neutrino mixing sensitivity can be improved by about 22\% at the same exposure by placing the detector at near and far distances of 15 m and 17 m, respectively, from the compact proto-type fast breeder reactor (PFBR) facility which has a higher thermal power of 1250 MW$_{th}$.
△ Less
Submitted 21 July, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
A plastic scintillator array for reactor based anti-neutrino studies
Authors:
D. Mulmule,
S. P. Behera,
P. K. Netrakanti,
D. K. Mishra,
V. K. S. Kashyap,
V. Jha,
L. M. Pant,
B. K. Nayak,
A. Saxena
Abstract:
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event cha…
▽ More
Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event characterization in the reactor and non-reactor environment. The data acquisition system based on waveform digitizers is being used for pulse processing and event triggering. Monte-Carlo based simulations using GEANT4 are performed to optimize lead (Pb) and borated polyethylene (BP) shielding for background reduction and to study the positron, neutron and $γ$-ray response in the ISMRAN detector. Characterization of plastic scintillator detectors with known radioactive sources is done for energy, timing and position measurements. Using the energy summation and bar multiplicity selection, coincident events from $\mathrm{{}^{60}Co}$ decay are reconstructed in non-reactor environment. Results from background measurements using various detectors are quantified in reactor ON and OFF condition. The shielding of 10 cm Pb and 10 cm BP along with the requirement of hits in multiple bars, reduces the uncorrelated background in reactor ON condition.
△ Less
Submitted 6 December, 2018; v1 submitted 12 June, 2018;
originally announced June 2018.
-
Measurement of the response of a liquid scintillation detector to monoenergetic electrons and neutrons
Authors:
P. C. Rout,
A. Gandhi,
T. Basak,
R. G. Thomas,
C. Ghosh,
A. Mitra,
G. Mishra,
S. P. Behera,
R. Kujur,
E. T. Mirgule,
B. K. Nayak,
A. Saxena,
Suresh Kumar,
V. M. Datar
Abstract:
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination…
▽ More
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $γ$-ray tagging has been carried out for various radioactive $γ$-ray sources. The measured electron response is found to be linear up to $\sim$4~MeVee and the resolution of the liquid scintillator at 1~MeVee is observed to be $\sim$~11\%. The pulse shape discrimination and pulse height response of the liquid scintillator for neutrons has been measured using $^7$Li(p,n$_1$)$^7$Be*(0.429 MeV) reaction. Non linear response to mono-energetic neutrons for the liquid scintillator is observed at E$_n$=5.3, 9.0 and 12.7 MeV. The measured response of the liquid scintillator for electrons and neutrons have been compared with Geant4 simulation.
△ Less
Submitted 16 May, 2017;
originally announced May 2017.
-
Physics Potential of the ICAL detector at the India-based Neutrino Observatory (INO)
Authors:
The ICAL Collaboration,
Shakeel Ahmed,
M. Sajjad Athar,
Rashid Hasan,
Mohammad Salim,
S. K. Singh,
S. S. R. Inbanathan,
Venktesh Singh,
V. S. Subrahmanyam,
Shiba Prasad Behera,
Vinay B. Chandratre,
Nitali Dash,
Vivek M. Datar,
V. K. S. Kashyap,
Ajit K. Mohanty,
Lalit M. Pant,
Animesh Chatterjee,
Sandhya Choubey,
Raj Gandhi,
Anushree Ghosh,
Deepak Tiwari,
Ali Ajmi,
S. Uma Sankar,
Prafulla Behera,
Aleena Chacko
, et al. (67 additional authors not shown)
Abstract:
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the mul…
▽ More
The upcoming 50 kt magnetized iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) is designed to study the atmospheric neutrinos and antineutrinos separately over a wide range of energies and path lengths. The primary focus of this experiment is to explore the Earth matter effects by observing the energy and zenith angle dependence of the atmospheric neutrinos in the multi-GeV range. This study will be crucial to address some of the outstanding issues in neutrino oscillation physics, including the fundamental issue of neutrino mass hierarchy. In this document, we present the physics potential of the detector as obtained from realistic detector simulations. We describe the simulation framework, the neutrino interactions in the detector, and the expected response of the detector to particles traversing it. The ICAL detector can determine the energy and direction of the muons to a high precision, and in addition, its sensitivity to multi-GeV hadrons increases its physics reach substantially. Its charge identification capability, and hence its ability to distinguish neutrinos from antineutrinos, makes it an efficient detector for determining the neutrino mass hierarchy. In this report, we outline the analyses carried out for the determination of neutrino mass hierarchy and precision measurements of atmospheric neutrino mixing parameters at ICAL, and give the expected physics reach of the detector with 10 years of runtime. We also explore the potential of ICAL for probing new physics scenarios like CPT violation and the presence of magnetic monopoles.
△ Less
Submitted 9 May, 2017; v1 submitted 27 May, 2015;
originally announced May 2015.
-
Simulation Studies for Electromagnetic Design of INO ICAL Magnet and its Response to Muons
Authors:
S. P. Behera,
M. S. Bhatia,
V. M. Datar,
A. K. Mohanty
Abstract:
The iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) will be used to measure neutrino mass hierarchy. The magnet in the ICAL detector will be used to distinguish the {μ^-} and {μ^+} events induced by {ν_μ} and {\bar{ν_μ}}, respectively. Due to the importance of the magnet in ICAL, an electromagnetic simulation has been carried out to study the B-field distribution in…
▽ More
The iron calorimeter (ICAL) detector at the India-based Neutrino Observatory (INO) will be used to measure neutrino mass hierarchy. The magnet in the ICAL detector will be used to distinguish the {μ^-} and {μ^+} events induced by {ν_μ} and {\bar{ν_μ}}, respectively. Due to the importance of the magnet in ICAL, an electromagnetic simulation has been carried out to study the B-field distribution in iron using various designs. The simulation shows better uniformity in the portion of the iron layer between the coils, which is bounded by regions which have lesser field strength as we move to the periphery of the iron layer. The ICAL magnet was configured to have a tiling structure that gave the minimum reluctance path while keeping a reasonably uniform field pattern.This translates into less Ampere-turns needed for generation of the required magnetic field. At low Ampere-turns, a larger fractional area with \vert B \vert \ge 1 Tesla (T) can be obtained by using a soft magnetic material. A study of the effect of the magnetic field on muon trajectories has been carried out using GEANT4. For muons up to 20 GeV, the energy resolution improves as the magnetic field increases from 1.1T to 1.8T. The charge identification efficiency for muons was found to be more than 90\% except for large zenith angles.
△ Less
Submitted 15 July, 2014; v1 submitted 16 June, 2014;
originally announced June 2014.