European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
Authors:
PIONEER Collaboration,
A. Adelmann,
W. Altmannshofer,
S. Ban,
O. Beesley,
A. Bolotnikov,
T. Brunner,
D. Bryman,
Q. Buat,
L. Caminada,
J. Carlton,
S. Chen,
M. Chiu,
V. Cirigliano,
S. Corrodi,
A. Crivellin,
S. Cuen-Rochin,
J. Datta,
B. Davis-Purcell,
A. Deshpande,
A. Di Canto,
A. Ebrahimi,
P. Fisher,
S. Foster,
K. Frahm
, et al. (54 additional authors not shown)
Abstract:
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimen…
▽ More
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.
△ Less
Submitted 14 April, 2025; v1 submitted 8 April, 2025;
originally announced April 2025.
Measurements of a LYSO crystal array from threshold to 100 MeV
Authors:
O. Beesley,
J. Carlton,
B. Davis-Purcell,
D. Ding,
S. Foster,
K. Frahm,
L. Gibbons,
T. Gorringe,
D. W. Hertzog,
S. Hochrein,
J. Hui,
P. Kammel,
J. LaBounty,
J. Liu,
R. Roehnelt,
P. Schwendimann,
A. Soter,
E. Swanson,
B. Taylor
Abstract:
We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution wer…
▽ More
We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30 - 100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. As an example of the results, the energy resolution at 70 MeV of 1.52 $\pm$ 0.03% is more than two times better than reported results using previous generation LYSO crystals.
△ Less
Submitted 2 February, 2025; v1 submitted 22 September, 2024;
originally announced September 2024.