Pilot tone-guided focused navigation for free-breathing whole-liver fat-water and T2* quantification
Authors:
Adèle LC Mackowiak,
Christopher W Roy,
Mariana BL Falcão,
Mario Bacher,
Aurélien Bustin,
Jérôme Yerly,
Peter Speier,
Matthias Stuber,
Naïk Vietti-Violi,
Jessica AM Bastiaansen
Abstract:
Purpose To achieve whole-liver motion-corrected fat fraction (FF) and R2* quantification with a 3-minute free-breathing (FB) 3D radial isotropic acquisition, for increased organ coverage, ease-of-use, and patient comfort. Methods A FB 3D radial multiecho gradient-echo liver acquisition with integrated Pilot Tone (PT) navigation and NTE=8 echoes was reconstructed with a motion-correction algorithm…
▽ More
Purpose To achieve whole-liver motion-corrected fat fraction (FF) and R2* quantification with a 3-minute free-breathing (FB) 3D radial isotropic acquisition, for increased organ coverage, ease-of-use, and patient comfort. Methods A FB 3D radial multiecho gradient-echo liver acquisition with integrated Pilot Tone (PT) navigation and NTE=8 echoes was reconstructed with a motion-correction algorithm based on focused navigation and guided by PT signals (PT-fNAV), with and without a denoising step. Fat fraction (FF) and R2* quantification using a graph cut algorithm was performed on the motion-corrected whole-liver multiecho volumes. Volunteer experiments (n=10) at 1.5T included reference 3D and 2D Cartesian breath-hold (BH) acquisitions. Image sharpness was assessed to evaluate the quality of motion correction with PT-fNAV, compared to a motion-resolved reconstruction. Fat-water images and parametric maps were compared to BH reference acquisitions following Cartesian trajectories, and to a routinely used clinical software (MRQuantiF). Results The image sharpness provided by PT-fNAV (with and without denoising) was similar in end-expiratory motion-resolved reconstructions. The 3D radial FB FF maps compared well with reference BH 3D Cartesian maps (bias +0.7%, limits of agreement (LOA) [-2.5; 4.0]%) and with 2D quantification with MRQuantiF (-0.2%, LOA [-1.1; 0.6]%). While expected visual deviations between proposed FB and reference BH R2* maps were observed, no significant differences were found in quantitative analyses. Conclusion A 3D radial technique with retrospective motion correction by PT-fNAV enabled FF and R2* quantification of the whole-liver at 1.5T. The FB whole-liver acquisition at isotropic spatial resolution compared in accuracy with BH techniques, enabling 3D assessment of steatosis in individuals with limited respiratory capabilities.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Fat-free noncontrast whole-heart CMR with fast and power-optimized off-resonant water excitation pulses
Authors:
Adèle L. C. Mackowiak,
Davide Piccini,
Jessica A. M. Bastiaansen
Abstract:
Background: Cardiovascular MRI (CMR) faces challenges due to the interference of bright fat signals in visualizing anatomical structures. Effective fat suppression is crucial when using whole-heart CMR. Conventional methods often fall short due to rapid fat signal recovery and water-selective off-resonant pulses come with tradeoffs between scan time and RF energy deposit. A lipid-insensitive binom…
▽ More
Background: Cardiovascular MRI (CMR) faces challenges due to the interference of bright fat signals in visualizing anatomical structures. Effective fat suppression is crucial when using whole-heart CMR. Conventional methods often fall short due to rapid fat signal recovery and water-selective off-resonant pulses come with tradeoffs between scan time and RF energy deposit. A lipid-insensitive binomial off-resonant (LIBOR) RF pulse is introduced, addressing concerns about RF energy and scan time for CMR at 3T. Methods: A short LIBOR pulse was developed and implemented in a free-breathing respiratory self-navigated whole-heart sequence at 3T. A BORR pulse with matched duration, as well as previously used LIBRE pulses, were implemented and optimized for fat suppression in numerical simulations and validated in healthy subjects (n=3). Whole-heart CMR was performed in healthy subjects (n=5) with all four pulses. The SNR of ventricular blood, skeletal muscle, myocardium, and subcutaneous fat, and the coronary vessel sharpness and length were compared. Results: Experiments validated numerical findings and near homogeneous fat suppression was achieved with all pulses. Comparing the short pulses (1ms), LIBOR reduced the RF power two-fold compared with LIBRE, and three-fold compared with BORR, and LIBOR significantly decreased overall fat SNR. The reduction in RF duration shortened the whole-heart acquisition from 8.5min to 7min. No significant differences in coronary arteries detection and sharpness were found when comparing all four pulses. Conclusion: LIBOR enabled whole-heart CMR under 7 minutes at 3T, with large volume fat signal suppression, while reducing RF power compared with LIBRE and BORR. LIBOR is an excellent candidate to address SAR problems encountered in CMR where fat suppression remains challenging and short RF pulses are required.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
Getting the phase consistent: The importance of phase description in balanced steady-state free precession MRI of multicompartment systems
Authors:
Nils M. J. Plähn,
Simone Poli,
Eva S. Peper,
Berk C. Açikgöz,
Roland Kreis,
Carl Ganter,
Jessica A. M. Bastiaansen
Abstract:
Purpose: Determine the correct mathematical phase description for balanced steady-state free precession (bSSFP) signals in multicompartment systems. Theory and Methods: Based on published bSSFP signal models, two distinct phase descriptions can be formulated: one predicting the presence and the other predicting the absence of destructive interference effects in multicompartment systems. Numerical…
▽ More
Purpose: Determine the correct mathematical phase description for balanced steady-state free precession (bSSFP) signals in multicompartment systems. Theory and Methods: Based on published bSSFP signal models, two distinct phase descriptions can be formulated: one predicting the presence and the other predicting the absence of destructive interference effects in multicompartment systems. Numerical simulations of bSSFP signals of water and acetone were performed to evaluate the predictions of these two distinct phase descriptions. For experimental validation, bSSFP profiles were measured at 3T using phase-cycled bSSFP acquisitions performed in a phantom containing mixtures of water and acetone, which replicates a system with two signal components. Localized single voxel MRS was performed at 7T to determine the relative chemical-shift of the acetone-water mixtures. Results: Based on the choice of phase description, the simulated bSSFP profiles of water-acetone mixtures varied significantly, either displaying or lacking destructive interference effects, as predicted theoretically. In phantom experiments, destructive interference was consistently observed in the measured bSSFP profiles of water-acetone mixtures, an observation which excludes the phase description that predicts an absence of destructive interference. The connection between the choice of phase description and predicted observation enables an unambiguous experimental identification of the correct phase description for multicompartment bSSFP profiles, which is consistent with Bloch equations. Conclusion: The study emphasizes that consistent phase descriptions are crucial for accurately describing multi-compartment bSSFP signals, as incorrect phase descriptions result in erroneous predictions.
△ Less
Submitted 13 October, 2023; v1 submitted 24 February, 2023;
originally announced February 2023.
-
Motion-resolved fat-fraction mapping with whole-heart free-running multiecho gre and pilot tone
Authors:
Adèle L. C. Mackowiak,
Christopher W. Roy,
Jérôme Yerly,
Mariana B. L. Falcão,
Mario Bacher,
Peter Speier,
Davide Piccini,
Matthias Stuber,
Jessica A. M. Bastiaansen
Abstract:
PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRAS…
▽ More
PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRASP based image reconstruction of the separate echoes, fat fraction, water fraction, R2star and B0 maps, as well as fat and water images, were generated with a maximum likelihood fitting algorithm using graph cuts. The acquisition, reconstruction and post-processing framework was tested in 10 healthy volunteers at 1.5T and compared to a free-breathing ECG-triggered 5-echo acquisition. RESULTS The acquisition was successfully validated in vivo, with motion compensation achieved over all collected echoes, in both respiratory and cardiac dimensions. Pilot Tone navigation provided respiratory and cardiac signals in good agreement (r=0.954 and r=0.783, respectively) with self-gating signal extraction based on the MR data of the first echo. The framework enabled pericardial fat imaging and quantification across the cardiac cycle, revealing a decrease in apparent FF at systole across volunteers. 3D motion-resolved fat fraction maps showed good correlation with reference ECG-triggered measurements, as well as significant difference in measurements performed with NTE = 4 and NTE = 8 echoes (P < 0.0001 in chest fat and P < 0.01 in pericardial fat). CONCLUSION Volunteer experiments at 1.5T demonstrated the feasibility of a whole-heart free-running fat-fraction mapping technique for cardiac MRI in a 6 min scan time, with a resolution of 2mm3 isotropic.
△ Less
Submitted 12 April, 2023; v1 submitted 12 October, 2022;
originally announced October 2022.
-
Free-running SIMilarity-Based Angiography (SIMBA) for simplified anatomical MR imaging of the heart
Authors:
John Heerfordt,
Kevin K. Whitehead,
Jessica A. M. Bastiaansen,
Lorenzo Di Sopra,
Christopher W. Roy,
Jérôme Yerly,
Bastien Milani,
Mark A. Fogel,
Matthias Stuber,
Davide Piccini
Abstract:
Purpose: Whole-heart MRA techniques typically target pre-determined motion states and address cardiac and respiratory dynamics independently. We propose a novel fast reconstruction algorithm, applicable to ungated free-running sequences, that leverages inherent similarities in the acquired data to avoid such physiological constraints.
Theory and Methods: The proposed SIMilarity-Based Angiography…
▽ More
Purpose: Whole-heart MRA techniques typically target pre-determined motion states and address cardiac and respiratory dynamics independently. We propose a novel fast reconstruction algorithm, applicable to ungated free-running sequences, that leverages inherent similarities in the acquired data to avoid such physiological constraints.
Theory and Methods: The proposed SIMilarity-Based Angiography (SIMBA) method clusters the continuously acquired k-space data in order to find a motion-consistent subset that can be reconstructed into a motion-suppressed whole-heart MRA. Free-running 3D radial datasets from six ferumoxytol-enhanced scans of pediatric cardiac patients and twelve non-contrast scans of healthy volunteers were reconstructed with a non-motion-suppressed regridding of all the acquired data (All Data), our proposed SIMBA method, and a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium interface sharpness, contrast ratio, and visibility of coronary artery ostia.
Results: Both the fast SIMBA reconstruction (~20s) and the FRF provided significantly higher blood-myocardium sharpness than All Data (P<0.001). No significant difference was observed among the former two. Significantly higher blood-myocardium contrast ratio was obtained with SIMBA compared to All Data and FRF (P<0.01). More coronary ostia could be visualized with both SIMBA and FRF than with All Data (All Data: 4/36, SIMBA: 30/36, FRF: 33/36, both P<0.001) but no significant difference was found between the first two.
Conclusion: The combination of free-running sequences and the fast SIMBA reconstruction, which operates without a priori assumptions related to physiological motion, forms a simple workflow for obtaining whole-heart MRA with sharp anatomical structures.
△ Less
Submitted 13 July, 2020;
originally announced July 2020.
-
Radical-free hyperpolarized MRI using endogenously-occurring pyruvate analogues and UV-induced nonpersistent radicals
Authors:
Claudia C Zanella,
Andrea Capozzi,
Hikari AI Yoshihara,
Alice Radaelli,
Lionel P Arn,
Rolf Gruetter,
Jessica AM Bastiaansen
Abstract:
It was demonstrated that nonpersistent radicals can be generated in frozen solutions of metabolites such as pyruvate by irradiation with ultraviolet (UV) light, enabling radical-free dissolution DNP. Although pyruvate is endogenous, an excess of additional pyruvate may perturb metabolic processes, making it potentially unsuitable as a polarizing agent when studying fatty acids or carbohydrate meta…
▽ More
It was demonstrated that nonpersistent radicals can be generated in frozen solutions of metabolites such as pyruvate by irradiation with ultraviolet (UV) light, enabling radical-free dissolution DNP. Although pyruvate is endogenous, an excess of additional pyruvate may perturb metabolic processes, making it potentially unsuitable as a polarizing agent when studying fatty acids or carbohydrate metabolism. Therefore, the aim of the study was to characterize solutions containing endogenously-occurring alternatives to pyruvate as UV-induced nonpersistent radical precursors for in vivo hyperpolarized MRI. The metabolites alpha-ketovalerate (AKV) and alpha-ketobutyrate (AKB) are analogues of pyruvate and were chosen as potential radical precursors. Sample formulations containing AKV and AKB were studied with UV-visible spectroscopy, irradiated with UV light, and their nonpersistent radical yields were quantified with ESR and compared to pyruvate. The addition of 13C labeled substrates to the sample matrix altered the radical yield of the precursors. Using AKB increased the 13C-labeled glucose liquid state polarization to 16.3 +/- 1.3% compared with 13.3 +/- 1.5% obtained with pyruvate, and 8.9 +/- 2.1% with AKV. For [1-13C]butyric acid, polarization levels of 12.1 +/- 1.1% for AKV and 12.9 +/- 1.7% for AKB were achieved. Hyperpolarized [1-13C]butyrate metabolism in the heart revealed label incorporation into [1-13C]acetylcarnitine, [1-13C]acetoacetate, [1-13C]butyrylcarnitine, [5-13C]glutamate and [5-13C]citrate. This study demonstrates the potential of AKV and AKB as endogenous polarizing agents for in vivo radical-free hyperpolarized MRI. UV-induced, nonpersistent radicals generated in endogenous metabolites enable high polarization without requiring radical filtration, thus simplifying the quality-control tests in clinical applications.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
SPARCQ: A new approach for fat fraction mapping using asymmetries in the phase-cycled bSSFP signal profile
Authors:
Giulia MC Rossi,
Adele LC Mackowiak,
Tom Hilbert,
Berk C Acikgoz,
Katarzyna Pierzchała,
Tobias Kober,
Jessica AM Bastiaansen
Abstract:
Purpose: To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction using asymmetries in the phase-cycled bSSFP profile. Methods: SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain repetition times. For each voxel, the measured signal profile is decom…
▽ More
Purpose: To develop SPARCQ (Signal Profile Asymmetries for Rapid Compartment Quantification), a novel approach to quantify fat fraction using asymmetries in the phase-cycled bSSFP profile. Methods: SPARCQ uses phase-cycling to obtain bSSFP frequency profiles, which display asymmetries in the presence of fat and water at certain repetition times. For each voxel, the measured signal profile is decomposed into a weighted sum of simulated profiles via multi-compartment dictionary matching. Each dictionary entry represents a single-compartment bSSFP profile with a specific off-resonance frequency and relaxation time ratio. Using the results of dictionary matching, the fractions of the different off-resonance components are extracted for each voxel, generating quantitative maps of water and fat fraction and banding-artifact-free images for the entire image volume. SPARCQ was validated using simulations, experiments in a water-fat phantom and in knees of healthy volunteers. Experimental results were compared with reference proton density fat fractions obtained with 1H-MRS (phantoms) and with multiecho gradient-echo MRI (phantoms and volunteers). SPARCQ repeatability was evaluated in six scan-rescan experiments. Results: Simulations showed that fat fraction quantification is accurate and robust for signal-to-noise ratios greater than 20. Phantom experiments demonstrated good agreement between SPARCQ and gold standard fat fractions. In volunteers, banding-artifact-free quantitative maps and water-fat-separated images obtained with SPARCQ and ME-GRE demonstrated the expected contrast between fatty and non-fatty tissues. The coefficient of repeatability of SPARCQ fat fraction was 0.0512. Conclusion: SPARCQ demonstrates potential for fat quantification using asymmetries in bSSFP profiles, and may be a promising alternative to conventional fat fraction quantification techniques.
△ Less
Submitted 13 April, 2023; v1 submitted 19 May, 2020;
originally announced May 2020.
-
A robust broadband fat suppressing phaser T2 preparation module for cardiac magnetic resonance imaging at 3T
Authors:
Lionel Arn,
Ruud B van Heeswijk,
Matthias Stuber,
Jessica AM Bastiaansen
Abstract:
Purpose: Designing a new T2 preparation (T2-Prep) module in order to simultaneously provide robust fat suppression and efficient T2 preparation without requiring an additional fat suppression module for T2-weighted imaging at 3T. Methods: The tip-down RF pulse of an adiabatic T2 preparation (T2-Prep) module was replaced by a custom-designed RF excitation pulse that induces a phase difference betwe…
▽ More
Purpose: Designing a new T2 preparation (T2-Prep) module in order to simultaneously provide robust fat suppression and efficient T2 preparation without requiring an additional fat suppression module for T2-weighted imaging at 3T. Methods: The tip-down RF pulse of an adiabatic T2 preparation (T2-Prep) module was replaced by a custom-designed RF excitation pulse that induces a phase difference between water and fat, resulting in a simultaneous T2 preparation of water signals and the suppression of fat signals at the end of the module (now called a phaser adiabatic T2-Prep). Using numerical simulations, in vitro and in vivo ECG-triggered navigator gated acquisitions of the human heart, the blood, myocardium and fat signal-to-noise ratio and right coronary artery (RCA) vessel sharpness using this approach were compared against previously published conventional adiabatic T2-Prep approaches Results: Numerical simulations predicted an increased fat suppression bandwidth and decreased sensitivity against transmit magnetic field inhomogeneities using the proposed approach, while preserving the water T2 preparation capabilities. This was confirmed by the tissue signals acquired on the phantom and the in vivo MRA, which show similar blood and myocardium SNR and CNR and significantly reduced fat SNR compared to the other methods tested. As a result, the RCA conspicuity was significantly increased and the motion artifacts were visually decreased. Conclusion: A novel fat-suppressing T2-preparation method was developed and implemented that demonstrated robust fat suppression and increased vessel sharpness compared with conventional techniques, while preserving its T2 preparation capabilities.
△ Less
Submitted 8 May, 2020;
originally announced May 2020.
-
Natively Fat-Suppressed 5D Whole-Heart MRI with a Radial Free-Running Fast-Interrupted Steady-State (FISS) Sequence at 1.5T and 3T
Authors:
Jessica AM Bastiaansen,
Davide Piccini,
Lorenzo Di Sopra,
Christopher W Roy,
Robert R Edelman,
Ioannis Koktzoglou,
Jerome Yerly,
Matthias Stuber
Abstract:
Purpose: To implement, optimize and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5T and 3T. Methods: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics…
▽ More
Purpose: To implement, optimize and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5T and 3T. Methods: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (readouts per FISS module (NR) and repetition time (TR)) for effective fat suppression. Subsequently, free-running FISS data were collected in ten healthy volunteers. All acquisitions were compared with a continuous bSSFP version of the same sequence, and both fat suppression and scan times were analyzed. Results: Simulations demonstrate a variable width and location of suppression bands in FISS that was dependent on TR and NR. For a fat suppression bandwidth of 100Hz and NR below 8, simulations demonstrated that a TR between 2.2ms and 3.0ms is required at 1.5T while a range of 3.0ms to 3.5ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with bSSPF at both field strengths. After protocol optimization, high-resolution (1.1mm x 1.1mm x 1.1mm) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to bSSFP.Conclusion: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.
△ Less
Submitted 8 March, 2019;
originally announced March 2019.
-
Flexible water excitation for fat-free MRI at 3 Tesla using lipid insensitive binomial off-resonant RF excitation (LIBRE) pulses
Authors:
Jessica AM Bastiaansen,
Matthias Stuber
Abstract:
Purpose: To develop a robust and flexible low power water excitation pulse that enables effective fat suppression at high magnetic field strength. Methods: A water excitation method that uses spatially non-selective pulses was optimized in numerical simulations, and implemented and tested in phantoms and healthy volunteers at 3T. The lipid insensitive binomial off-resonant excitation (LIBRE) pulse…
▽ More
Purpose: To develop a robust and flexible low power water excitation pulse that enables effective fat suppression at high magnetic field strength. Methods: A water excitation method that uses spatially non-selective pulses was optimized in numerical simulations, and implemented and tested in phantoms and healthy volunteers at 3T. The lipid insensitive binomial off-resonant excitation (LIBRE) pulse comprises two low power rectangular sub-pulses that have a variable frequency offset, phase offset and duration. The capability and extent of LIBRE fat suppression was quantitatively compared with conventional fat saturation (FS) and water excitation (WE) techniques. Results: LIBRE enables simultaneous water excitation and near complete fat suppression in large volumes at 3T as demonstrated by numerical simulations, and experiments. In phantoms and in human subjects, the frequency responses matched well with those from the numerical simulation. Comparing FS and WE, LIBRE demonstrated an improved robustness to magnetic field inhomogeneities, and a much more effectively suppressed fat signal. This applied for a range of pulse durations and pulses as short as 1.4 ms. Conclusion: A flexible water excitation method was developed that shows robust, near complete fat suppression at 3T.
△ Less
Submitted 7 March, 2019;
originally announced March 2019.
-
Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE)
Authors:
Jessica A. M. Bastiaansen,
Ruud B. van Heeswijk,
Matthias Stuber,
Davide Piccini
Abstract:
Robust and homogeneous lipid suppression is mandatory for coronary magnetic resonance angiography (MRA) since coronary arteries are commonly embedded in fat. However, effective large volume lipid suppression becomes challenging when performing radial whole-heart coronary MRA and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression also generates ar…
▽ More
Robust and homogeneous lipid suppression is mandatory for coronary magnetic resonance angiography (MRA) since coronary arteries are commonly embedded in fat. However, effective large volume lipid suppression becomes challenging when performing radial whole-heart coronary MRA and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression also generates artifacts, and may affect advanced motion correction methods. The aim was to evaluate a recently reported lipid insensitive MRI method for self-navigated coronary MRA at 3T. Lipid insensitive binomial off resonant excitation (LIBRE) radiofrequency (RF) excitation pulses were included into a self-navigated 3D radial GRE coronary MRA sequence at 3T. LIBRE was compared against conventional fat saturation (FS) and binomial 1-180°-1 water excitation (WE). First, fat suppression of all techniques was numerically characterized using Matlab and experimentally validated in phantoms and in legs of human volunteers. Subsequently, free-breathing self-navigated coronary MRA was performed using the LIBRE pulse as well as FS and WE in ten volunteers. Results obtained in the simulations were confirmed by the experimental validations as LIBRE enabled near complete fat suppression for 3D radial imaging in vitro and in vivo. For self-navigated whole-heart coronary MRA at 3T, fat SNR was significantly attenuated using LIBRE compared with conventional FS. LIBRE increased the RCA vessel sharpness significantly (37 +/- 9% (LIBRE) vs. 29 +/- 8% (FS) and 30 +/- 8% (WE), both p<0.05) and led to a significant increase in the measured RCA vessel length to (83 +/- 31 mm (LIBRE) vs. 56 +/- 12 mm (FS) and 59 +/- 27 (WE) p<0.05). LIBRE enables robust large volume fat suppression and significantly improves coronary artery image quality at 3T compared to the use of conventional fat suppression and water excitation.
△ Less
Submitted 12 June, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.