-
Conceptual design of the Spin Physics Detector
Authors:
V. M. Abazov,
V. Abramov,
L. G. Afanasyev,
R. R. Akhunzyanov,
A. V. Akindinov,
N. Akopov,
I. G. Alekseev,
A. M. Aleshko,
V. Yu. Alexakhin,
G. D. Alexeev,
M. Alexeev,
A. Amoroso,
I. V. Anikin,
V. F. Andreev,
V. A. Anosov,
A. B. Arbuzov,
N. I. Azorskiy,
A. A. Baldin,
V. V. Balandina,
E. G. Baldina,
M. Yu. Barabanov,
S. G. Barsov,
V. A. Baskov,
A. N. Beloborodov,
I. N. Belov
, et al. (270 additional authors not shown)
Abstract:
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarize…
▽ More
The Spin Physics Detector, a universal facility for studying the nucleon spin structure and other spin-related phenomena with polarized proton and deuteron beams, is proposed to be placed in one of the two interaction points of the NICA collider that is under construction at the Joint Institute for Nuclear Research (Dubna, Russia). At the heart of the project there is huge experience with polarized beams at JINR.
The main objective of the proposed experiment is the comprehensive study of the unpolarized and polarized gluon content of the nucleon. Spin measurements at the Spin Physics Detector at the NICA collider have bright perspectives to make a unique contribution and challenge our understanding of the spin structure of the nucleon. In this document the Conceptual Design of the Spin Physics Detector is presented.
△ Less
Submitted 2 February, 2022; v1 submitted 31 January, 2021;
originally announced February 2021.
-
Monitoring of the Photon Beam
Authors:
V. I. Alekseev,
V. A. Baskov,
V. A. Dronov,
A. I. Lvov,
A. V. Koltsov,
Yu. F. Krechetov,
V. V. Polyansky,
S. S. Sidorin
Abstract:
Presented are the characteristics of systems for monitoring the intensity of the bremsstrahlung photon beam of the PAKHRA accelerator based on Cherenkov counters.
Presented are the characteristics of systems for monitoring the intensity of the bremsstrahlung photon beam of the PAKHRA accelerator based on Cherenkov counters.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Calibration of a Shower Lead-Scintillation Spectrometer by Cosmic Radiation
Authors:
V. I. Alekseev,
V. A. Baskov,
V. A. Dronov,
A. I. Lvov,
A. V. Koltsov,
Yu. F. Krechetov,
V. V. Polyansky,
S. S. Sidorin
Abstract:
The results of calibration by cosmic muons of a shower lead-scintillation spectrometer of the sandwich type designed to work in high-intensity photon and electron beams with an energy of 0.1 - 1.0 GeV are presented. It was found that the relative energy resolution of the spectrometer depends on the angle of entry of cosmic muons into the spectrometer in the vertical plane and does not depend on th…
▽ More
The results of calibration by cosmic muons of a shower lead-scintillation spectrometer of the sandwich type designed to work in high-intensity photon and electron beams with an energy of 0.1 - 1.0 GeV are presented. It was found that the relative energy resolution of the spectrometer depends on the angle of entry of cosmic muons into the spectrometer in the vertical plane and does not depend on the angle of entry in the horizontal plane. The relative energy resolution of the spectrometer was 16%. Placing an additional lead-scintillation assembly in front of the spectrometer improved the relative energy resolution of the spectrometer to 9%.
△ Less
Submitted 16 April, 2020;
originally announced April 2020.
-
Determination of the Energy Characteristics of an Electron Beam using a Light Scintillator
Authors:
V. I. Alekseev,
V. A. Baskov,
V. A. Dronov,
A. I. L'vov,
A. V. Koltsov,
Yu. F. Krechetov,
V. V. Polyansky
Abstract:
The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is experimentally presented. The energy calibration of the quasi-monochromatic electron beam of the Pakhra accelerator of the P. N. Lebedev Physical Institute of the Russian…
▽ More
The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is experimentally presented. The energy calibration of the quasi-monochromatic electron beam of the Pakhra accelerator of the P. N. Lebedev Physical Institute of the Russian Academy of Sciences using scintillation detectors with a thickness of 14.5, 20, 23.5 and 51.2 cm was performed. For electron beam energies up to about 100 MeV and scintillation detector thicknesses from 5 to 20 cm the accuracy of electron beam energy determination was 10 to 20%, respectively.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Calibration of The Extended Quadrahedral NaI(Tl) Spectrometer by Cosmic Muons
Authors:
V. A. Baskov,
B. B. Govorkov,
V. V. Polyansky
Abstract:
The results of the extended quadrahedral NaI(Tl) spectrometer`s calibration by cosmic muons are presented. The signal amplitude and energy resolution of the spectrometer have complex dependencies on the voltage at the photomultiplier and the entry point of the particle into the spectrometer in the transverse direction. When the voltage across the photomultiplier divider photomultiplier is U = 1150…
▽ More
The results of the extended quadrahedral NaI(Tl) spectrometer`s calibration by cosmic muons are presented. The signal amplitude and energy resolution of the spectrometer have complex dependencies on the voltage at the photomultiplier and the entry point of the particle into the spectrometer in the transverse direction. When the voltage across the photomultiplier divider photomultiplier is U = 1150 V the homogeneous signals area is observed at about 90% of the spectrometer length, the energy resolution is about 7%.
△ Less
Submitted 30 March, 2020;
originally announced March 2020.
-
Characteristics of the secondary electrons calibration beam of the accelerator S-25R "Pakhra"
Authors:
V. I. Alekseev,
V. A. Baskov,
V. A. Dronov,
A. I. Lvov,
A. V. Koltsov,
Yu. F. Krechetov,
V. V. Polyansky,
S. S. Sidorin
Abstract:
The characteristics of the secondary electrons` calibration quasi-monochromatic beam of the accelerator S-25R "Pakhra" of the Lebedev Physical Institute of the Russian Academy of Sciences (LPI) on the basis of magnet SP-57 are presented. With an electron energy in the range of 45-280 MeV, a collimator diameter in front of the trigger counters of 3 mm and copper Converter thicknesses of 1-3 mm, the…
▽ More
The characteristics of the secondary electrons` calibration quasi-monochromatic beam of the accelerator S-25R "Pakhra" of the Lebedev Physical Institute of the Russian Academy of Sciences (LPI) on the basis of magnet SP-57 are presented. With an electron energy in the range of 45-280 MeV, a collimator diameter in front of the trigger counters of 3 mm and copper Converter thicknesses of 1-3 mm, the energy resolution and beam intensity were 4.4-2.2% and around 16 e/sec, respectively.
△ Less
Submitted 16 December, 2019;
originally announced December 2019.
-
Detection of low energy electrons by a total absorption Cherenkov spectrometer
Authors:
V. I. Alekseev,
V. A. Baskov,
V. A. Dronov,
A. I. L'vov,
A. V. Koltsov,
Yu. F. Krechetov,
E. I. Malinovsky,
V. V. Polyansky
Abstract:
Presented are results of calibration, with a quasi-monochromatic electron beam, of a total absorption Cherenkov spectrometer based on the 14.8 X0 lead glass TF-1. It was found that the energy resolution of the spectrometer was 89% to 10% in the energy range of the electron beam E = 6 to 285 MeV, respectively.
Presented are results of calibration, with a quasi-monochromatic electron beam, of a total absorption Cherenkov spectrometer based on the 14.8 X0 lead glass TF-1. It was found that the energy resolution of the spectrometer was 89% to 10% in the energy range of the electron beam E = 6 to 285 MeV, respectively.
△ Less
Submitted 28 November, 2019;
originally announced November 2019.