-
Absolute frequency measurement of a Lu$^+$ $(^{3}\rm D_1)$ optical frequency standard via link to international atomic time
Authors:
Zhao Zhang,
Qi Zhao,
Qin Qichen,
N. Jayjong,
M. D. K. Lee,
K. J. Arnold,
M. D. Barrett
Abstract:
We report on an absolute frequency measurement of the ${\rm Lu}^{+}\,(^{3}\rm D_1)$ standard frequency which is defined as the hyperfine-average of $^{1}\rm S_0$ to $^{3}\rm D_1$ optical clock transitions in $^{176}{\rm Lu}^{+}$. The measurement result of $353\,638\,794\,073\,800.35(33)$Hz with a fractional uncertainty of $9.2 \times 10^{-16}$ was obtained by operating a single-ion…
▽ More
We report on an absolute frequency measurement of the ${\rm Lu}^{+}\,(^{3}\rm D_1)$ standard frequency which is defined as the hyperfine-average of $^{1}\rm S_0$ to $^{3}\rm D_1$ optical clock transitions in $^{176}{\rm Lu}^{+}$. The measurement result of $353\,638\,794\,073\,800.35(33)$Hz with a fractional uncertainty of $9.2 \times 10^{-16}$ was obtained by operating a single-ion $^{176}{\rm Lu}^{+}$ frequency standard intermittently over 3 months with a total uptime of 162 hours. Traceability to the International System of Units (SI) is realized by remote link to International Atomic Time. This is the first reported absolute frequency value for a ${\rm Lu}^{+}\,(^{3}\rm D_1)$ optical frequency standard.
△ Less
Submitted 27 May, 2025; v1 submitted 14 February, 2025;
originally announced February 2025.
-
An extrapolation method for polarizability assessments of ion-based optical clocks
Authors:
K. J. Arnold,
M. D. Barrett
Abstract:
We present a numerical method for extrapolating polarizability measurements to dc as done in the assessment of blackbody radiation shifts for ion-based clocks. The method explicitly accounts for the frequency dependence of relevant atomic transitions without introducing an ad hoc modelling function. It incorporates \emph{a priori} atomic structure calculations, which allows measurements to be augm…
▽ More
We present a numerical method for extrapolating polarizability measurements to dc as done in the assessment of blackbody radiation shifts for ion-based clocks. The method explicitly accounts for the frequency dependence of relevant atomic transitions without introducing an ad hoc modelling function. It incorporates \emph{a priori} atomic structure calculations, which allows measurements to be augmented by calculations if there is insufficient data to make a purely measurement based estimate. The method also provides indicators of inconsistencies between theory and experiment or inadequacies of the data for making an extrapolation. We use results from Al$^+$, Lu$^+$, and Yb$^+$ to illustrate features of the method.
△ Less
Submitted 2 September, 2024;
originally announced September 2024.
-
Validating a lutetium frequency reference
Authors:
Kyle J. Arnold,
Scott Bustabad,
Qin Qichen,
Zhao Zhang,
Qi Zhao,
Murray D. Barrett
Abstract:
We review our progress in developing a frequency reference with singly ionized lutetium and give estimates of the levels of inaccuracy we expect to achieve in the near future with both the $^1S_0\leftrightarrow{}^3D_1$ and $^1S_0\leftrightarrow{}^3D_2$ transitions. Based on established experimental results, we show that inaccuracies at the low $10^{-19}$ level are readily achievable for the…
▽ More
We review our progress in developing a frequency reference with singly ionized lutetium and give estimates of the levels of inaccuracy we expect to achieve in the near future with both the $^1S_0\leftrightarrow{}^3D_1$ and $^1S_0\leftrightarrow{}^3D_2$ transitions. Based on established experimental results, we show that inaccuracies at the low $10^{-19}$ level are readily achievable for the $^1S_0\leftrightarrow{}^3D_1$ transition, and the frequency ratio between the two transitions is limited almost entirely by the BBR shift. We argue that the frequency ratio measured within the one apparatus provides a well-defined metric to compare and establish the performance of remotely located systems. For the measurement of an in situ frequency ratio, relativistic shifts drop out and both transitions experience the same electromagnetic environment. Consequently, the uncertainty budget for the ratio is practically identical to the uncertainty budgets for the individual transitions. If the ratios for two or more systems disagree we can be certain at least one of the clock assessments is incorrect. If they agree, subsequent comparisons on one transition would only differ by relativistic effects. Since motional effects are easily assessed and typically small for a heavy ion, only the differential gravitational red-shift will significantly contribute and this can be confirmed by comparison on the second transition.
△ Less
Submitted 25 April, 2024;
originally announced April 2024.
-
Enhanced micromotion compensation using a phase modulated light field
Authors:
K. J. Arnold,
N. Jayjong,
M. L. D. Kang,
Qin Qichen,
Zhao Zhang,
Qi Zhao,
M. D. Barrett
Abstract:
We investigate sideband spectroscopy of a trapped ion using a probe laser phase modulated at the trap drive frequency. The enhanced sensitivity of our technique over traditional sideband spectroscopy allows us to detect stray fields of $0.01\,\mathrm{V/m}$ on a timescale of a few minutes and detect differential phases of $5\,μ\mathrm{rad}$ between applied ac potentials. We also demonstrate the abi…
▽ More
We investigate sideband spectroscopy of a trapped ion using a probe laser phase modulated at the trap drive frequency. The enhanced sensitivity of our technique over traditional sideband spectroscopy allows us to detect stray fields of $0.01\,\mathrm{V/m}$ on a timescale of a few minutes and detect differential phases of $5\,μ\mathrm{rad}$ between applied ac potentials. We also demonstrate the ability suppress Doppler shifts from excess motion to well below the limit imposed by the intrinsic motion of the ion in the vibrational ground-state. The technique we introduce can be readily implemented in any ion trap system that utilizes sideband spectroscopy for micromotion compensation and can be seamlessly integrated into experiments in a fully automated way
△ Less
Submitted 28 February, 2024;
originally announced February 2024.
-
$^{176}$Lu$^+$ clock comparison at the $10^{-18}$ level via correlation spectroscopy
Authors:
Zhang Zhiqiang,
Kyle J. Arnold,
Rattakorn Kaewuam,
M. D. Barrett
Abstract:
We experimentally demonstrate agreement between two $^{176}$Lu$^+$ frequency references using correlation spectroscopy. From a comparison at different magnetic fields, we obtain a quadratic Zeeman coefficient of $-4.89264(88)\,\mathrm{Hz/mT^2}$, which gives a corresponding fractional frequency uncertainty contribution of just $2.5\times 10^{-20}$ for comparisons at typical operating fields of 0.1\…
▽ More
We experimentally demonstrate agreement between two $^{176}$Lu$^+$ frequency references using correlation spectroscopy. From a comparison at different magnetic fields, we obtain a quadratic Zeeman coefficient of $-4.89264(88)\,\mathrm{Hz/mT^2}$, which gives a corresponding fractional frequency uncertainty contribution of just $2.5\times 10^{-20}$ for comparisons at typical operating fields of 0.1\,mT. A subsequent comparison with both systems at 0.1\,mT, demonstrates a fractional frequency difference of $(-2.0\pm(3.7)_\mathrm{stat}\pm(0.9)_\mathrm{sys})\times10^{-18}$, where `stat' and `sys' indicate statistical and systematic uncertainty, respectively.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Hyperfine-mediated effects in a Lu$^+$ optical clock
Authors:
Zhiqiang Zhang,
K. J. Arnold,
R. Kaewuam,
M. S. Safronova,
M. D. Barrett
Abstract:
We consider hyperfine-mediated effects for clock transitions in $^{176}$Lu$^+$. Mixing of fine structure levels due to the hyperfine interaction bring about modifications to Landé $g$-factors and the quadrupole moment for a given state. Explicit expressions are derived for both $g$-factor and quadrupole corrections, for which leading order terms arise from the nuclear magnetic dipole coupling. Hig…
▽ More
We consider hyperfine-mediated effects for clock transitions in $^{176}$Lu$^+$. Mixing of fine structure levels due to the hyperfine interaction bring about modifications to Landé $g$-factors and the quadrupole moment for a given state. Explicit expressions are derived for both $g$-factor and quadrupole corrections, for which leading order terms arise from the nuclear magnetic dipole coupling. High accuracy measurements of the $g$-factors for the $^1S_0$ and $^3D_1$ hyperfine levels are carried out, which provide an experimental determination of the leading order correction terms.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
-
Precision measurement of the $^3D_1$ and $^3D_2$ quadrupole moments in Lu$^+$
Authors:
R. Kaewuam,
T. R. Tan,
Zhiqiang Zhang,
K. J. Arnold,
M. S. Safronova,
M. D. Barrett
Abstract:
Precision measurements of the Lu$^+$ $^3D_1$ and $^3D_2$ quadrupole moments have been carried out giving $Θ(^3D_1)=0.63862(74)\,e a_0^2$ and $Θ(^3D_2)=0.8602(14)\,e a_0^2$, respectively. The measurements utilize the differential shift between ions in a multi-ion crystal so that effects of external field gradients do not contribute leaving only the well defined Coulomb interaction. At this level of…
▽ More
Precision measurements of the Lu$^+$ $^3D_1$ and $^3D_2$ quadrupole moments have been carried out giving $Θ(^3D_1)=0.63862(74)\,e a_0^2$ and $Θ(^3D_2)=0.8602(14)\,e a_0^2$, respectively. The measurements utilize the differential shift between ions in a multi-ion crystal so that effects of external field gradients do not contribute leaving only the well defined Coulomb interaction. At this level of precision, hyperfine-mediated corrections will likely be important.
△ Less
Submitted 24 August, 2020;
originally announced August 2020.
-
Branching fractions for $P_{3/2}$ decays in Ba$^+$
Authors:
Zhiqiang Zhang,
K. J. Arnold,
S. R. Chanu,
R. Kaewuam,
M. S. Safronova,
M. D. Barrett
Abstract:
Branching fractions for decays from the $P_{3/2}$ level in $^{138}$Ba$^+$ have been measured with a single laser-cooled ion. Decay probabilities to $S_{1/2}$, $D_{3/2}$ and $D_{5/2}$ are determined to be $0.741716(71)$, $0.028031(23)$ and $0.230253(61)$, respectively, which are an order of magnitude improvement over previous results. Our methodology only involves optical pumping and state detectio…
▽ More
Branching fractions for decays from the $P_{3/2}$ level in $^{138}$Ba$^+$ have been measured with a single laser-cooled ion. Decay probabilities to $S_{1/2}$, $D_{3/2}$ and $D_{5/2}$ are determined to be $0.741716(71)$, $0.028031(23)$ and $0.230253(61)$, respectively, which are an order of magnitude improvement over previous results. Our methodology only involves optical pumping and state detection, and is hence relatively free of systematic effects. Measurements are carried out in two different ways to check for consistency. Our analysis also includes a measurement of the $D_{5/2}$ lifetime, for which we obtain 30.14(40)\,s.
△ Less
Submitted 4 March, 2020;
originally announced March 2020.
-
Magic wavelength of the $^{138}$Ba$^+$ $6s\;{}^2S_{1/2}-5d\;{}^2D_{5/2}$ clock transition
Authors:
S. R. Chanu,
V. P. W. Koh,
K. J. Arnold,
R. Kaewuam,
T. R. Tan,
Zhiqiang Zhang,
M. S. Safronova,
M. D. Barrett
Abstract:
The zero crossing of the dynamic differential scalar polarizability of the $S_{1/2}-D_{5/2}$ clock transition in $^{138}$Ba$^+$ has been determined to be $459.1614(28)\,$THz. Together with previously determined matrix elements and branching ratios, this tightly constrains the dynamic differential scalar polarizability of the clock transition over a large wavelength range ($\gtrsim 700\,$nm). In pa…
▽ More
The zero crossing of the dynamic differential scalar polarizability of the $S_{1/2}-D_{5/2}$ clock transition in $^{138}$Ba$^+$ has been determined to be $459.1614(28)\,$THz. Together with previously determined matrix elements and branching ratios, this tightly constrains the dynamic differential scalar polarizability of the clock transition over a large wavelength range ($\gtrsim 700\,$nm). In particular it allows an estimate of the blackbody radiation shift of the clock transition at room temperature.
△ Less
Submitted 4 March, 2020; v1 submitted 21 October, 2019;
originally announced October 2019.
-
Hyperfine averaging by dynamic decoupling in a multi-ion lutetium clock
Authors:
R. Kaewuam,
T. R. Tan,
K. J. Arnold,
S. R. Chanu,
Zhiqiang Zhang,
M. D. Barrett
Abstract:
We propose and experimentally demonstrate a scheme which effects hyperfine averaging during a Ramsey interrogation of a clock transition. The method eliminates the need to average over multiple optical transitions, reduces the sensitivity of the clock to its environment, and reduces inhomogeneous broadening in a multi-ion clock. The method is compatible with auto-balanced Ramsey spectroscopy, whic…
▽ More
We propose and experimentally demonstrate a scheme which effects hyperfine averaging during a Ramsey interrogation of a clock transition. The method eliminates the need to average over multiple optical transitions, reduces the sensitivity of the clock to its environment, and reduces inhomogeneous broadening in a multi-ion clock. The method is compatible with auto-balanced Ramsey spectroscopy, which facilitates elimination of residual shifts due to imperfect implementation and ac Stark shifts from the optical probe. We demonstrate the scheme using correlation spectroscopy of the $^1S_0$-to-$^3D_1$ clock transition in a three-ion Lu+ clock. From the demonstration we are able to provide a measurement of the $^3D_1$ quadrupole moment, $Θ(^3D_1)=0.634(9)ea_0^2$.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
Precision measurements on the $^{138}$Ba$^+$ $6s^2S_{1/2}-5d^2D_{5/2}$ clock transition
Authors:
Kyle J. Arnold,
Rattakorn Kaewuam,
Sapam R. Chanu,
Ting Rei Tan,
Zhiqiang Zhang,
Murray D. Barrett
Abstract:
Measurement of the $^{138}$Ba$^+$ ${}^2S_{1/2} - {}^2D_{5/2}$ clock transition frequency and $D_{5/2}$ Landé $g_J$ factor are reported. The clock transition frequency $ν_{\mathrm{Ba}^+}=170\,126\,432\,449\,333.31\pm(0.39)_\mathrm{stat}\pm(0.29)_\mathrm{sys}\,$Hz, is obtained with accuracy limited by the frequency calibration of the maser used as a reference oscillator. The Landé $g_J$-factor for t…
▽ More
Measurement of the $^{138}$Ba$^+$ ${}^2S_{1/2} - {}^2D_{5/2}$ clock transition frequency and $D_{5/2}$ Landé $g_J$ factor are reported. The clock transition frequency $ν_{\mathrm{Ba}^+}=170\,126\,432\,449\,333.31\pm(0.39)_\mathrm{stat}\pm(0.29)_\mathrm{sys}\,$Hz, is obtained with accuracy limited by the frequency calibration of the maser used as a reference oscillator. The Landé $g_J$-factor for the ${}^2D_{5/2}$ level is determined to be $g_{D}=1.200\,367\,39(24)$, which is a 30-fold improvement on previous measurements. The $g$-factor measurements are corrected for an ac-magnetic field from trap-drive-induced currents in the electrodes, and data taken over a range of magnetic fields underscores the importance of accounting for this systematic.
△ Less
Submitted 11 March, 2020; v1 submitted 21 June, 2019;
originally announced June 2019.
-
Measurements of the branching ratios for $6P_{1/2}$ decays in $^{138}$Ba$^+$
Authors:
K. J. Arnold,
S. R. Chanu,
R. Kaewuam,
T. R. Tan,
L. Yeo,
Zhiqiang Zhang,
M. S. Safronova,
M. D. Barrett
Abstract:
Measurement of the branching ratios for $6P_{1/2}$ decays to $6S_{1/2}$ and $5D_{3/2}$ in $^{138}$Ba$^+$ are reported with the decay probability from $6P_{1/2}$ to $5D_{3/2}$ measured to be $p=0.268177\pm(37)_\mathrm{stat}-(20)_\mathrm{sys}$. This result differs from a recent report by $12σ$. A detailed account of systematics is given and the likely source of the discrepancy is identified. The new…
▽ More
Measurement of the branching ratios for $6P_{1/2}$ decays to $6S_{1/2}$ and $5D_{3/2}$ in $^{138}$Ba$^+$ are reported with the decay probability from $6P_{1/2}$ to $5D_{3/2}$ measured to be $p=0.268177\pm(37)_\mathrm{stat}-(20)_\mathrm{sys}$. This result differs from a recent report by $12σ$. A detailed account of systematics is given and the likely source of the discrepancy is identified. The new value of the branching ratio is combined with a previous experimental results to give a new estimate of $τ=7.855(10)\,\mathrm{ns}$ for the $6P_{1/2}$ lifetime. In addition, ratios of matrix elements calculated from theory are combined with experimental results to provide improved theoretical estimates of the $6P_{3/2}$ lifetime and the associated matrix elements.
△ Less
Submitted 21 October, 2019; v1 submitted 16 May, 2019;
originally announced May 2019.
-
Polarizability assessments of ion-based optical clocks
Authors:
M. D. Barrett,
K. J. Arnold,
M. S. Safronova
Abstract:
It is shown that the dynamic differential scalar polarisability of the $S_{1/2}-D_{5/2}$ transition in $^{138}$Ba$^+$ can be determined to an inaccuracy below $0.5\%$ across a wide wavelength range ($λ>700\,\mathrm{nm}$). This can be achieved using measurements for which accurate determination of laser intensity is not required, and most of the required measurements are already in the literature.…
▽ More
It is shown that the dynamic differential scalar polarisability of the $S_{1/2}-D_{5/2}$ transition in $^{138}$Ba$^+$ can be determined to an inaccuracy below $0.5\%$ across a wide wavelength range ($λ>700\,\mathrm{nm}$). This can be achieved using measurements for which accurate determination of laser intensity is not required, and most of the required measurements are already in the literature. Measurement of a laser-induced ac-stark shift of the clock transition would then provide an \emph{in situ} measurement of the laser's intensity to the same $0.5\%$ level of inaccuracy, which is not easily achieved by other means. This would allow accurate polarisability measurements for clock transitions in other ions, through comparison with $^{138}$Ba$^+$. The approach would be equally applicable to Sr$^+$ and Ca$^+$, with the latter being immediately applicable to Al$^+$/Ca$^+$ quantum logic clocks.
△ Less
Submitted 11 October, 2019; v1 submitted 13 May, 2019;
originally announced May 2019.
-
Suppressing inhomogeneous broadening in a lutetium multi-ion optical clock
Authors:
Ting Rei Tan,
Rattakorn Kaewuam,
Kyle J. Arnold,
Sapam R. Chanu,
Zhiqiang Zhang,
Marianna Safronova,
Murray D. Barrett
Abstract:
We demonstrate precision measurement and control of inhomogeneous broadening in a multi-ion clock consisting of three $^{176}$Lu$^+$ ions. Microwave spectroscopy between hyperfine states in the $^3D_1$ level is used to characterise differential systematic shifts between ions, most notably those associated with the electric quadrupole moment. By appropriate alignment of the magnetic field, we demon…
▽ More
We demonstrate precision measurement and control of inhomogeneous broadening in a multi-ion clock consisting of three $^{176}$Lu$^+$ ions. Microwave spectroscopy between hyperfine states in the $^3D_1$ level is used to characterise differential systematic shifts between ions, most notably those associated with the electric quadrupole moment. By appropriate alignment of the magnetic field, we demonstrate suppression of these effects to the $\sim 10^{-17}$ level relative to the $^1S_0\leftrightarrow{}^3D_1$ optical transition frequency. Correlation spectroscopy on the optical transition demonstrates the feasibility of a 10s Ramsey interrogation in the three ion configuration with a corresponding projection noise limited stability of $σ(τ)=8.2\times 10^{-17}/\sqrtτ$
△ Less
Submitted 9 May, 2019;
originally announced May 2019.
-
Spectroscopy of the $^1S_0$-to-$^1D_2$ clock transition in $^{176}$Lu$^+$
Authors:
R. Kaewuam,
T. R. Tan,
K. J. Arnold,
M. D. Barrett
Abstract:
High precision spectroscopy of the $^1S_0$-to-${^1}D_2$ clock transition of $^{176}$Lu is reported. Measurements are performed with Hertz level precision with the accuracy of the hyperfine-averaged frequency limited by the calibration of an active hydrogen maser to the SI definition of the second via a GPS link. The measurements also provide accurate determination of the $^1D_2$ hyperfine structur…
▽ More
High precision spectroscopy of the $^1S_0$-to-${^1}D_2$ clock transition of $^{176}$Lu is reported. Measurements are performed with Hertz level precision with the accuracy of the hyperfine-averaged frequency limited by the calibration of an active hydrogen maser to the SI definition of the second via a GPS link. The measurements also provide accurate determination of the $^1D_2$ hyperfine structure. Hyperfine structure constants associated with the magnetic octupole and electric hexadecapole moments of the nucleus are considered, which includes a derivation of correction terms from third-order perturbation theory.
△ Less
Submitted 14 January, 2019;
originally announced January 2019.
-
Oscillating quadrupole effects in high precision metrology
Authors:
Kyle J. Arnold,
R. Kaewuan,
T. R. Tan,
M. D. Barrett
Abstract:
The influence of oscillating quadrupole fields on atomic energy levels is examined theoretically and general expressions for the quadrupole matrix elements are given. The results are relevant to any ion-based clock in which one of the clock states supports a quadrupole moment. Clock shifts are estimated for $^{176}$Lu$^+$ and indicate that coupling to the quadrupole field would not be a limitation…
▽ More
The influence of oscillating quadrupole fields on atomic energy levels is examined theoretically and general expressions for the quadrupole matrix elements are given. The results are relevant to any ion-based clock in which one of the clock states supports a quadrupole moment. Clock shifts are estimated for $^{176}$Lu$^+$ and indicate that coupling to the quadrupole field would not be a limitation to clock accuracy at the $\lesssim10^{-19}$ level. Nevertheless, a method is suggested that would allow this shift to be calibrated. This method utilises a resonant quadrupole coupling that enables the quadrupole moment of the atom to be measured. A proof-of-principle demonstration is given using $^{138}$Ba$^+$, in which the quadrupole moment of the $D_{5/2}$ state is estimated to be $Θ=3.229(89) e a_0^2$.
△ Less
Submitted 25 November, 2018;
originally announced November 2018.
-
Dynamic polarizability measurements in $^{176}$Lu$^+$
Authors:
K. J. Arnold,
R. Kaewuam,
T. R. Tan,
S. G. Porsev,
M. S. Safronova,
M. D. Barrett
Abstract:
We measure the differential polarizability of the $^{176}$Lu$^+$ $^1S_0$ -to- ${^3}D_1$ clock transition at multiple wavelengths. This experimentally characterizes the differential dynamic polarizability for frequencies up to 372 THz and allows an experimental determination of the dynamic correction to the blackbody radiation shift for the clock transition. In addition, measurements at the near re…
▽ More
We measure the differential polarizability of the $^{176}$Lu$^+$ $^1S_0$ -to- ${^3}D_1$ clock transition at multiple wavelengths. This experimentally characterizes the differential dynamic polarizability for frequencies up to 372 THz and allows an experimental determination of the dynamic correction to the blackbody radiation shift for the clock transition. In addition, measurements at the near resonant wavelengths of 598 and 646 nm determine the two dominant contributions to the differential dynamic polarizability below 372 THz. These additional measurements are carried out by two independent methods to verify the validity of our methodology. We also carry out a theoretical calculation of the polarizabilities using the hybrid method that combines the configuration interaction (CI) and the coupled-cluster approaches, incorporating for the first time quadratic non-linear terms and partial triple excitations in the coupled-cluster calculations. The experimental measurements of the $|\langle ^3D_1|| r || ^3P_J\rangle|$ matrix elements provide high-precision benchmarks for this theoretical approach.
△ Less
Submitted 25 October, 2018;
originally announced October 2018.
-
Oscillating magnetic field effects in high precision metrology
Authors:
H. C. J. Gan,
G. Maslennikov,
K. W. Tseng,
T. R. Tan,
R. Kaewuam,
K. J. Arnold,
D. Matsukevich,
M. D. Barrett
Abstract:
We examine a range of effects arising from ac magnetic fields in high precision metrology. These results are directly relevant to high precision measurements, and accuracy assessments for state-of-the-art optical clocks. Strategies to characterize these effects are discussed and a simple technique to accurately determine trap-induced ac magnetic fields in a linear Paul trap is demonstrated using…
▽ More
We examine a range of effects arising from ac magnetic fields in high precision metrology. These results are directly relevant to high precision measurements, and accuracy assessments for state-of-the-art optical clocks. Strategies to characterize these effects are discussed and a simple technique to accurately determine trap-induced ac magnetic fields in a linear Paul trap is demonstrated using $^{171}\mathrm{Yb}^+$
△ Less
Submitted 7 July, 2018; v1 submitted 1 July, 2018;
originally announced July 2018.
-
Dicke model simulation via cavity-assisted Raman transitions
Authors:
Zhang Zhiqiang,
Chern Hui Lee,
Ravi Kumar,
K. J. Arnold,
Stuart J. Masson,
A. L. Grimsmo,
A. S. Parkins,
M. D. Barrett
Abstract:
The Dicke model is of fundamental importance in quantum mechanics for understanding the collective behaviour of atoms coupled to a single electromagnetic mode. In this paper, we demonstrate a Dicke-model simulation using cavity-assisted Raman transitions in a configuration using counter-propagating laser beams. The observations indicate that motional effects should be included to fully account for…
▽ More
The Dicke model is of fundamental importance in quantum mechanics for understanding the collective behaviour of atoms coupled to a single electromagnetic mode. In this paper, we demonstrate a Dicke-model simulation using cavity-assisted Raman transitions in a configuration using counter-propagating laser beams. The observations indicate that motional effects should be included to fully account for the results and these results are contrasted with the experiments using single-beam and co-propagating configurations. A theoretical description is given that accounts for the beam geometries used in the experiments and indicates the potential role of motional effects. In particular a model is given that highlights the influence of Doppler broadening on the observed thresholds.
△ Less
Submitted 24 January, 2018;
originally announced January 2018.
-
Blackbody radiation shift assessment for a lutetium ion clock
Authors:
Kyle J. Arnold,
Rattakorn Kaewuam,
Arpan Roy,
Ting Rei Tan,
Murray D. Barrett
Abstract:
We measure the dynamic differential scalar polarizabilities at 10.6 $μ$m for two candidate clock transitions in $^{176}\mathrm{Lu}^+$. The fractional black body radiation (BBR) shifts at 300 K for the $^1S_0 \leftrightarrow {^3D_1}$ and $^1S_0 \leftrightarrow {^3D_2}$ transitions are evaluated to be $-1.36\,(9) \times 10^{-18}$ and $2.70 \,(21) \times10^{-17}$, respectively. The former is the lowe…
▽ More
We measure the dynamic differential scalar polarizabilities at 10.6 $μ$m for two candidate clock transitions in $^{176}\mathrm{Lu}^+$. The fractional black body radiation (BBR) shifts at 300 K for the $^1S_0 \leftrightarrow {^3D_1}$ and $^1S_0 \leftrightarrow {^3D_2}$ transitions are evaluated to be $-1.36\,(9) \times 10^{-18}$ and $2.70 \,(21) \times10^{-17}$, respectively. The former is the lowest of any established optical atomic clock.
△ Less
Submitted 26 October, 2018; v1 submitted 1 December, 2017;
originally announced December 2017.
-
Laser spectroscopy of $^{176}$Lu$^+$
Authors:
R. Kaewuam,
A. Roy,
T. R. Tan,
K. J. Arnold,
M. D. Barrett
Abstract:
We perform high resolution spectroscopy on $^{176}$Lu$^+$ including the $^1S_0\leftrightarrow{^3}D_1$ and $^1S_0\leftrightarrow{^3}D_2$ clock transitions. Hyperfine structures and optical frequencies relative to the $^1S_0$ ground state of four low lying excited states are given to a few tens of kHz resolution. This covers the most relevant transitions involved in clock operation with this isotope…
▽ More
We perform high resolution spectroscopy on $^{176}$Lu$^+$ including the $^1S_0\leftrightarrow{^3}D_1$ and $^1S_0\leftrightarrow{^3}D_2$ clock transitions. Hyperfine structures and optical frequencies relative to the $^1S_0$ ground state of four low lying excited states are given to a few tens of kHz resolution. This covers the most relevant transitions involved in clock operation with this isotope. Additionally, measurements of the $^3D_2$ hyperfine structure may provide access to higher order nuclear moments, specifically the magnetic octupole and electric hexadecapole moments.
△ Less
Submitted 8 January, 2019; v1 submitted 10 July, 2017;
originally announced July 2017.
-
Observation of the $^1$S$_0$ to $^3$D$_1$ clock transition in $^{175}$Lu$^+$
Authors:
Kyle J. Arnold,
R. Kaewuam,
A. Roy,
E. Paez,
S. Wang,
M. D. Barrett
Abstract:
We report the first laser spectroscopy of the $^1$S$_0$ to $^3$D$_1$ clock transition in $^{175}$Lu$^+$. Clock operation is demonstrated on three pairs of Zeeman transitions, one pair from each hyperfine manifold of the $^3$D$_1$ term. We measure the hyperfine intervals of the $^3$D$_1$ to 10 ppb uncertainty and infer the optical frequency averaged over the three hyperfine transitions to be 353.63…
▽ More
We report the first laser spectroscopy of the $^1$S$_0$ to $^3$D$_1$ clock transition in $^{175}$Lu$^+$. Clock operation is demonstrated on three pairs of Zeeman transitions, one pair from each hyperfine manifold of the $^3$D$_1$ term. We measure the hyperfine intervals of the $^3$D$_1$ to 10 ppb uncertainty and infer the optical frequency averaged over the three hyperfine transitions to be 353.639 915 952 2 (6) THz. The lifetime of the $^3$D$_1$ state is inferred to be $174^{+23}_{-32}$ hours from the M1 coupling strength.
△ Less
Submitted 6 March, 2017; v1 submitted 2 September, 2016;
originally announced September 2016.
-
Suppression of clock shifts at field-insensitive transitions
Authors:
Kyle J. Arnold,
M. D. Barrett
Abstract:
We show that it is possible to significantly reduce quadrupole and tensor polarizability shifts of a clock transition by operating at a judiciously chosen field-insensitive point. In some cases shifts are almost completely eliminated making the transition an effective J = 0 to J = 0 candidate. This significantly improves the feasibility of a recent proposal for clock operation with large ion cryst…
▽ More
We show that it is possible to significantly reduce quadrupole and tensor polarizability shifts of a clock transition by operating at a judiciously chosen field-insensitive point. In some cases shifts are almost completely eliminated making the transition an effective J = 0 to J = 0 candidate. This significantly improves the feasibility of a recent proposal for clock operation with large ion crystals. For such multi-ion clocks, geometric constraints and selection rules naturally divide clock operation into two categories based on the orientation of the magnetic field. We discuss the limitations imposed on each type and how calibrations might be carried out for clock operation.
△ Less
Submitted 14 July, 2016;
originally announced July 2016.
-
Atomic Properties of Lu$^+$
Authors:
Eduardo Paez,
K. J. Arnold,
Elnur Hajiyev,
S. G. Porsev,
V. A. Dzuba,
U. I. Safronova,
M. S. Safronova,
M. D. Barrett
Abstract:
Singly ionised Lutetium has recently been suggested as a potential clock candidate. Here we report a joint experimental and theoretical investigation of \ce{Lu^+}. Measurements relevant to practical clock operation are made and compared to atomic structure calculations. Calculations of scalar and tensor polarizabilities for clock states over a range of wavelengths are also given. These results wil…
▽ More
Singly ionised Lutetium has recently been suggested as a potential clock candidate. Here we report a joint experimental and theoretical investigation of \ce{Lu^+}. Measurements relevant to practical clock operation are made and compared to atomic structure calculations. Calculations of scalar and tensor polarizabilities for clock states over a range of wavelengths are also given. These results will be useful for future work with this clock candidate.
△ Less
Submitted 18 February, 2016;
originally announced February 2016.
-
Prospects for atomic clocks based on large ion crystals
Authors:
Kyle Arnold,
Elnur Haciyev,
Eduardo Paez,
Chern Hui Lee,
John Bollinger,
M. D. Barrett
Abstract:
We investigate the feasibility of precision frequency metrology with large ion crystals. For clock candidates with a negative differential static polarisability, we show that micromotion effects should not impede the performance of the clock. Using Lu+ as a specific example, we show that quadrupole shifts due to the electric fields from neighbouring ions do not significantly affect clock performan…
▽ More
We investigate the feasibility of precision frequency metrology with large ion crystals. For clock candidates with a negative differential static polarisability, we show that micromotion effects should not impede the performance of the clock. Using Lu+ as a specific example, we show that quadrupole shifts due to the electric fields from neighbouring ions do not significantly affect clock performance. We also show that effects from the tensor polarisability can be effectively managed with a compensation laser at least for a small number of ions (<1000). These results provide new possibilities for ion-based atomic clocks, allowing them to achieve stability levels comparable to neutral atoms in optical lattices and a viable path to greater levels of accuracy.
△ Less
Submitted 8 July, 2015;
originally announced July 2015.
-
Systematic evaluation of an atomic clock at 2e-18 total uncertainty
Authors:
T. L. Nicholson,
S. L. Campbell,
R. B. Hutson,
G. E. Marti,
B. J. Bloom,
R. L. McNally,
W. Zhang,
M. D. Barrett,
M. S. Safronova,
G. F. Strouse,
W. L. Tew,
J. Ye
Abstract:
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. This work takes an important step towards realizing the full potential of a many-…
▽ More
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. This work takes an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87Sr optical lattice clock now achieves fractional stability of 2.2e-16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms' thermal environment, and the atomic response to room-temperature BBR. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1e-18 in fractional frequency units.
△ Less
Submitted 6 May, 2015; v1 submitted 29 December, 2014;
originally announced December 2014.
-
Developing a field independent frequency reference by averaging over transitions to multiple hyperfine levels
Authors:
M. D. Barrett
Abstract:
We show that by averaging over transitions to multiple hyperfine levels, quadrupole shifts and dominant Zeeman effects exactly cancel whenever the nuclear spin, I, is at least as large as the total electronic angular momentum, J. The average frequency thus defines a frequency reference which is inherently independent of external magnetic fields and electric field gradients. We use Lu+ to illustrat…
▽ More
We show that by averaging over transitions to multiple hyperfine levels, quadrupole shifts and dominant Zeeman effects exactly cancel whenever the nuclear spin, I, is at least as large as the total electronic angular momentum, J. The average frequency thus defines a frequency reference which is inherently independent of external magnetic fields and electric field gradients. We use Lu+ to illustrate the method although the approach could be readily adapted to other atomic species. This approach practically eliminates the quadrupole and Zeeman shift considerations for many clock candidates.
△ Less
Submitted 2 November, 2014;
originally announced November 2014.
-
Realization of the Dicke model using cavity-assisted Raman transitions
Authors:
Markus P. Baden,
Kyle J. Arnold,
Arne L. Grimsmo,
Scott Parkins,
Murray D. Barrett
Abstract:
We realize an open version of the Dicke model by coupling two hyperfine ground states using two cavity-assisted Raman transitions. The interaction due to only one of the couplings is described by the Tavis-Cummings model and we observe a normal mode splitting in the transmission around the dispersively shifted cavity. With both couplings present the dynamics are described by the Dicke model and we…
▽ More
We realize an open version of the Dicke model by coupling two hyperfine ground states using two cavity-assisted Raman transitions. The interaction due to only one of the couplings is described by the Tavis-Cummings model and we observe a normal mode splitting in the transmission around the dispersively shifted cavity. With both couplings present the dynamics are described by the Dicke model and we measure the onset of superradiant scattering into the cavity above a critical coupling strength.
△ Less
Submitted 30 May, 2017; v1 submitted 2 April, 2014;
originally announced April 2014.
-
Experimental determination of the nuclear magnetic octupole moment of $^{137}$Ba$^+$ ion
Authors:
Nicholas C. Lewty,
Boon Leng Chuah,
Radu Cazan,
B. K. Sahoo,
M. D. Barrett
Abstract:
We perform precision measurements on the 5D$_{5/2}$ manifold hyperfine intervals of a single trapped ion, $^{137}$Ba$^+$. RF spectroscopy is used to measure the hyperfine intervals to an accuracy of a few Hz. Our results provide a three orders of magnitude improvement in accuracy over previous work and also provide a 10-fold improvement in the value of $g_J$ for this level. These results complemen…
▽ More
We perform precision measurements on the 5D$_{5/2}$ manifold hyperfine intervals of a single trapped ion, $^{137}$Ba$^+$. RF spectroscopy is used to measure the hyperfine intervals to an accuracy of a few Hz. Our results provide a three orders of magnitude improvement in accuracy over previous work and also provide a 10-fold improvement in the value of $g_J$ for this level. These results complement our previous work on the 5D$_{3/2}$ manifold of $^{137}$Ba$^+$, providing an independent measurement of the nuclear octupole, and a consistency check on atomic structure calculations.
△ Less
Submitted 1 July, 2013; v1 submitted 20 May, 2013;
originally announced May 2013.
-
Reliability test for the experimental results of electric quadrupole hyperfine structure constants and new assessment of nuclear quadrupole moments in $^{135,137}$Ba
Authors:
B. K. Sahoo,
M. D. Barrett,
B. P. Das
Abstract:
We investigate electric quadrupole hyperfine structure constant ($B$) results in $^{135}$Ba$^+$ and $^{137}$Ba$^+$ and compare their ratios with the reported measurements of the ratio between the nuclear quadrupole moment ($Q$) values of these isotopes. We carry out confidence tests for the reported experimental $B$ values and calculations of $B/Q$ from the present work. Inconsistencies in the exp…
▽ More
We investigate electric quadrupole hyperfine structure constant ($B$) results in $^{135}$Ba$^+$ and $^{137}$Ba$^+$ and compare their ratios with the reported measurements of the ratio between the nuclear quadrupole moment ($Q$) values of these isotopes. We carry out confidence tests for the reported experimental $B$ values and calculations of $B/Q$ from the present work. Inconsistencies in the experimental $B$ values are observed in both the isotopes from different experiments performed using the same techniques. The present calculations are carried out using an all order relativistic many-body theory considering only single and double excitations in the coupled-cluster ansatz. After a detailed analysis of the results, the values of $Q$ we obtain for $^{135}$Ba and $^{137}$Ba are 0.153(2)$b$ and 0.236(3)$b$, respectively, which differ by about 4% from the currently referred precise values.
△ Less
Submitted 27 March, 2013;
originally announced March 2013.
-
Sub-Doppler Cavity Cooling Beyond The Lamb-Dicke Limit
Authors:
Boon Leng Chuah,
Nicholas C. Lewty,
Radu Cazan,
Murray D. Barrett
Abstract:
We investigate the dynamics of cavity cooling of a single ion beyond the Lamb-Dicke regime and demonstrate a cooling limit of approximately 50% of the Doppler temperature using a high finesse cavity for the first time. We also study the statistical properties of the ion-cavity emission and present a model that maps the phonon states to the photon states. With this model, we explain the super-Poiss…
▽ More
We investigate the dynamics of cavity cooling of a single ion beyond the Lamb-Dicke regime and demonstrate a cooling limit of approximately 50% of the Doppler temperature using a high finesse cavity for the first time. We also study the statistical properties of the ion-cavity emission and present a model that maps the phonon states to the photon states. With this model, we explain the super-Poissonian photon distribution observed in our experiments and propose a method to estimate the ion temperature in a real-time manner based on the statistical behavior of the photon emission from the cavity.
△ Less
Submitted 19 April, 2013; v1 submitted 19 February, 2013;
originally announced February 2013.
-
Minimization of Ion Micromotion in a Linear Paul Trap with a High Finesse Cavity
Authors:
Boon Leng Chuah,
Nicholas C. Lewty,
Radu Cazan,
Murray D. Barrett
Abstract:
We demonstrate minimization of ion micromotion in a linear Paul trap with the use of a high finesse cavity. The excess ion micromotion projected along the optical cavity axis or along the laser propagation direction manifests itself as sideband peaks around the carrier in the ion-cavity emission spectrum. By minimizing the sideband height in the emission spectrum, we are able to reduce the micromo…
▽ More
We demonstrate minimization of ion micromotion in a linear Paul trap with the use of a high finesse cavity. The excess ion micromotion projected along the optical cavity axis or along the laser propagation direction manifests itself as sideband peaks around the carrier in the ion-cavity emission spectrum. By minimizing the sideband height in the emission spectrum, we are able to reduce the micromotion amplitude to approximately the spread of the ground state wave function. This method is useful for cavity QED experiments as it allows for efficient 3-D micromotion compensation despite optical access limitations imposed by the cavity mirrors. We also show that sub-nanometer micromotion compensation is possible with our current system.
△ Less
Submitted 1 November, 2012;
originally announced November 2012.
-
Self-Organization Threshold with an External Potential
Authors:
K. J. Arnold,
M. P. Baden,
M. D. Barrett
Abstract:
We derive threshold equations for self-organization of laser driven atoms in an optical cavity. Our analysis includes probing with either a traveling wave or a retro reflected lattice. These two scenarios lead to qualitatively different behavior in terms of the response of the system as a function of cavity detuning with respect to the probe. In addition our analysis includes the effects of an int…
▽ More
We derive threshold equations for self-organization of laser driven atoms in an optical cavity. Our analysis includes probing with either a traveling wave or a retro reflected lattice. These two scenarios lead to qualitatively different behavior in terms of the response of the system as a function of cavity detuning with respect to the probe. In addition our analysis includes the effects of an intra-cavity trapping potential which is also shown to impact on the threshold condition. We specifically consider the case of an intra-cavity lattice but our treatment can easily be modified to other geometries.
△ Less
Submitted 21 August, 2012;
originally announced August 2012.
-
Trapping and detection of single atoms using a spherical mirror
Authors:
Arpan Roy,
Andrew Bah Shen Jing,
Murray D. Barrett
Abstract:
We fabricate a miniature spherical mirror for tightly focusing an optical dipole trap for neutral atoms. The mirror formation process is modelled to predict the dimensions for particular fabrication parameters. We integrate the spherical mirror with a neutral atom experiment to trap and detect a single atom with high efficiency. The mirror serves the dual purpose of focusing the dipole trap as wel…
▽ More
We fabricate a miniature spherical mirror for tightly focusing an optical dipole trap for neutral atoms. The mirror formation process is modelled to predict the dimensions for particular fabrication parameters. We integrate the spherical mirror with a neutral atom experiment to trap and detect a single atom with high efficiency. The mirror serves the dual purpose of focusing the dipole trap as well as collection of the atomic fluorescence into an optical fibre.
△ Less
Submitted 27 July, 2012;
originally announced July 2012.
-
Spectroscopy on a single trapped 137Ba+ ion for nuclear magnetic octupole moment determination
Authors:
Nicholas C. Lewty,
Boon Leng Chuah,
Radu Cazan,
B. K. Sahoo,
M. D. Barrett
Abstract:
We present precision measurements of the hyperfine intervals in the 5D3/2 manifold of a single trapped Barium ion, 137 Ba+ . Measurements of the hyperfine intervals are made between mF = 0 sublevels over a range of magnetic fields allowing us to interpolate to the zero field values with an accuracy below a few Hz, an improvement on previous measurements by three orders of magnitude. Our results, i…
▽ More
We present precision measurements of the hyperfine intervals in the 5D3/2 manifold of a single trapped Barium ion, 137 Ba+ . Measurements of the hyperfine intervals are made between mF = 0 sublevels over a range of magnetic fields allowing us to interpolate to the zero field values with an accuracy below a few Hz, an improvement on previous measurements by three orders of magnitude. Our results, in conjunction with theoretical calculations, provide a 30-fold reduction in the uncertainty of the magnetic dipole (A) and electric quadrupole (B) hyperfine constants. In addition, we obtain the magnetic octupole constant (C) with an accuracy below 0.1 Hz. This gives a subsequent determination of the nuclear magnetic octupole moment, Ω, with an uncertainty of 1% limited almost completely by the accuracy of theoretical calculations. This constitutes the first observation of the octupole moment in 137 Ba+ and the most accurately determined octupole moment to date.
△ Less
Submitted 4 July, 2012; v1 submitted 31 May, 2012;
originally announced May 2012.
-
Self-Organization Threshold Scaling for Thermal Atoms Coupled to a Cavity
Authors:
K. J. Arnold,
M. P. Baden,
M. D. Barrett
Abstract:
We make a detailed experimental study of the threshold for the self-organization of thermal 87Rb atoms coupled to a high-finesse cavity over a range of atom numbers and cavity detunings. We investigate the difference between probing with a traveling wave and a retroreflected lattice. These two scenarios lead to qualitatively different behavior in terms of the response of the system as a function o…
▽ More
We make a detailed experimental study of the threshold for the self-organization of thermal 87Rb atoms coupled to a high-finesse cavity over a range of atom numbers and cavity detunings. We investigate the difference between probing with a traveling wave and a retroreflected lattice. These two scenarios lead to qualitatively different behavior in terms of the response of the system as a function of cavity detuning with respect to the probe. In both cases, we confirm a N-1 scaling of the threshold with atom number.
△ Less
Submitted 3 November, 2012; v1 submitted 18 May, 2012;
originally announced May 2012.
-
Fabrication of Glass Micro-Cavities for Cavity QED Experiments
Authors:
Arpan Roy,
Murray D. Barrett
Abstract:
We report a process for fabricating high quality, defect-free spherical mirror templates suitable for developing high finesse optical Fabry-Perot resonators. The process utilizes the controlled reflow of borosilicate glass and differential pressure to produce mirrors with 0.3 nanometer surface roughness. The dimensions of the mirrors are in the 0.5-5mm range making them suitable candidates for int…
▽ More
We report a process for fabricating high quality, defect-free spherical mirror templates suitable for developing high finesse optical Fabry-Perot resonators. The process utilizes the controlled reflow of borosilicate glass and differential pressure to produce mirrors with 0.3 nanometer surface roughness. The dimensions of the mirrors are in the 0.5-5mm range making them suitable candidates for integration with on-chip neutral atom and ion experiments where enhanced interaction between atoms and photons are required. Moreover the mirror curvature, dimension and placement is readily controlled and the process can easily provide an array of such mirrors. We show that cavities constructed with these mirror templates are well suited to quantum information applications such as single photon sources and atom-photon entanglement.
△ Less
Submitted 9 August, 2011;
originally announced August 2011.
-
All-Optical BEC in a 1.06 micron dipole trap
Authors:
K. J. Arnold,
M. D. Barrett
Abstract:
We report the all-optical production of a Rb87 Bose-Einstein condensate (BEC) in a simple 1.06 micron dipole trap experiment. We load a single beam dipole trap directly from a magneto-optic trap (MOT) using an optimized loading sequence. After evaporation in the single beam, a second crossed beam is used for compression. The intensity in both beams is then reduced for evaporation to BEC. We obtain…
▽ More
We report the all-optical production of a Rb87 Bose-Einstein condensate (BEC) in a simple 1.06 micron dipole trap experiment. We load a single beam dipole trap directly from a magneto-optic trap (MOT) using an optimized loading sequence. After evaporation in the single beam, a second crossed beam is used for compression. The intensity in both beams is then reduced for evaporation to BEC. We obtain a BEC with 3.5E4 atoms after 3 seconds of total evaporation time. We also give a detailed account of the thermal distribution in cross beam traps. This account highlights the possible difficulties in using shorter wavelength lasers to condense all optically.
△ Less
Submitted 9 May, 2011; v1 submitted 6 January, 2011;
originally announced January 2011.
-
A Storage Ring for Neutral Atoms
Authors:
J. A. Sauer,
M. D. Barrett,
M. S. Chapman
Abstract:
We have demonstrated a storage ring for ultra-cold neutral atoms. Atoms with mean velocities of 1 m/s corresponding to kinetic energies of ~100 neV are confined to a 2 cm diameter ring by magnetic forces produced by two current-carrying wires. Up to 10^6 atoms are loaded at a time in the ring, and 7 revolutions are clearly observed. Additionally, we have demonstrated multiple loading of the ring…
▽ More
We have demonstrated a storage ring for ultra-cold neutral atoms. Atoms with mean velocities of 1 m/s corresponding to kinetic energies of ~100 neV are confined to a 2 cm diameter ring by magnetic forces produced by two current-carrying wires. Up to 10^6 atoms are loaded at a time in the ring, and 7 revolutions are clearly observed. Additionally, we have demonstrated multiple loading of the ring and deterministic manipulation of the longitudinal velocity distribution of the atoms using applied laser pulses. Applications of this ring include large area atom interferometers and cw monochromatic atomic beam generation.
△ Less
Submitted 30 August, 2001;
originally announced August 2001.