-
Tensor-valued and frequency-dependent diffusion MRI and magnetization transfer saturation MRI evolution during adult mouse brain maturation
Authors:
Naila Rahman,
Jake Hamilton,
Kathy Xu,
Arthur Brown,
Corey A. Baron
Abstract:
Although rodent models are a predominant study model in neuroscience research, research investigating healthy rodent brain maturation remains limited. This motivates further study of normal brain maturation in rodents to exclude confounds of developmental changes from interpretations of disease mechanisms. 11 C57Bl/6 mice (6 males) were scanned longitudinally at 3, 4, 5, and 8 months of age using…
▽ More
Although rodent models are a predominant study model in neuroscience research, research investigating healthy rodent brain maturation remains limited. This motivates further study of normal brain maturation in rodents to exclude confounds of developmental changes from interpretations of disease mechanisms. 11 C57Bl/6 mice (6 males) were scanned longitudinally at 3, 4, 5, and 8 months of age using frequency-dependent and tensor-valued diffusion MRI (dMRI), and Magnetization Transfer saturation (MTsat) MRI. Total kurtosis showed significant increases over time in all regions, which was driven by increases in isotropic kurtosis while anisotropic kurtosis remained stable. Increases in total and isotropic kurtosis with age were matched with increases in MTsat. Quadratic fits revealed that most metrics show a maximum/minimum around 5-6 months of age. Most dMRI metrics revealed significantly different trajectories between males and females, while the MT metrics did not. Linear fits between kurtosis and MT metrics highlighted that changes in total kurtosis found throughout normal brain development are driven by isotropic kurtosis, while differences in total kurtosis between brain regions are driven by anisotropic kurtosis. Overall, the trends observed in conventional dMRI and MT metrics are comparable to previous studies on normal brain development, while the trajectories of our more advanced dMRI metrics provide novel insight. Based on the developmental trajectories of tensor-valued dMRI and MT metrics, our results suggest myelination during brain maturation is not a main contributor to microscopic diffusion anisotropy and anisotropic kurtosis in axons. For studies that only calculate total kurtosis, we suggest caution in attributing neurobiological changes to changes in total kurtosis as we show here constant anisotropic kurtosis in the presence of increasing myelin content.
△ Less
Submitted 26 September, 2023;
originally announced September 2023.
-
Robust frequency-dependent diffusion kurtosis computation using an efficient direction scheme, axisymmetric modelling, and spatial regularization
Authors:
J. Hamilton,
K. Xu,
A. Brown,
C. A. Baron
Abstract:
Frequency-dependent diffusion MRI (dMRI) using oscillating gradient encoding and diffusion kurtosis imaging (DKI) techniques have been shown to provide additional insight into tissue microstructure compared to conventional dMRI. However, a technical challenge when combining these techniques is that the generation of the large b-values required for DKI is difficult when using oscillating gradient d…
▽ More
Frequency-dependent diffusion MRI (dMRI) using oscillating gradient encoding and diffusion kurtosis imaging (DKI) techniques have been shown to provide additional insight into tissue microstructure compared to conventional dMRI. However, a technical challenge when combining these techniques is that the generation of the large b-values required for DKI is difficult when using oscillating gradient diffusion encoding. While efficient encoding schemes can enable larger b-values by maximizing multiple gradient channels simultaneously, they do not have sufficient directions to enable fitting of the full kurtosis tensor. Accordingly, we investigate a DKI fitting algorithm that combines axisymmetric DKI fitting, a prior that enforces the same axis of symmetry for all oscillating gradient frequencies, and spatial regularization, which together enable robust DKI fitting for a 10-direction scheme that offers double the b-value compared to traditional direction schemes. Using data from mice (oscillating frequencies of 0, 60, and 120 Hz) and humans (0 Hz only), we first show that axisymmetric modelling is advantageous over full kurtosis tensor fitting in terms of preserving contrast and reducing noise in DKI maps, and improved DKI map quality when using an efficient encoding scheme with averaging as compared to a traditional scheme with more encoding directions. We also demonstrate how spatial regularization during fitting preserves spatial features better than using Gaussian filtering prior to fitting, which is an oft-reported preprocessing step for DKI, and that enforcing consistent axes of symmetries across frequencies improves fitting quality. Thus, the use of an efficient 10-direction scheme combined with the proposed DKI fitting algorithm provides robust maps of frequency-dependent directional kurtosis parameters that can be used to explore novel biomarkers for various pathologies.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
Correction of high-order phase variation effects in dynamic field monitoring
Authors:
Paul I. Dubovan,
Kyle M. Gilbert,
Corey A. Baron
Abstract:
Purpose: Field monitoring measures field perturbations, which can be accounted for during image reconstructions. In certain field monitoring environments, significant phase deviations can arise far from isocenter due to the finite extent of the gradient and/or main magnet. This can degrade the accuracy of field dynamics when field probes are placed near or outside the diameter spherical volume of…
▽ More
Purpose: Field monitoring measures field perturbations, which can be accounted for during image reconstructions. In certain field monitoring environments, significant phase deviations can arise far from isocenter due to the finite extent of the gradient and/or main magnet. This can degrade the accuracy of field dynamics when field probes are placed near or outside the diameter spherical volume of the gradient coils and/or main magnet, leading to corrupted image quality. The objective of this work was to develop a correction algorithm that reduces errors from highly nonlinear phase variations at distant field probes in field dynamic fits. Methods: The algorithm is split into three components. Component one fits phase coefficients one spatial order at a time, while the second implements a weighted least squares solution based on probe distance. After initial fitting, component three calculates phase residuals and removes the phase for distant probes before re-fitting. Two healthy volunteers were scanned on a head-only 7T MRI using diffusion-weighted single-shot spiral and EPI sequences and field monitoring was performed. Images were reconstructed with and without phase coefficient correction and compared qualitatively. Results: The algorithm was able to correct corrupted field dynamics, resulting in image quality improvements. Significant artefact reduction was observed when correcting higher order fits, especially for diffusion weighted images. Stepwise fitting provided the most correction benefit, which was marginally improved when adding weighted least squares and phase residual corrections. Conclusion: The proposed algorithm can mitigate effects of phase errors in field monitoring, providing improved reliability of field dynamic characterization.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
High-resolution single-shot spiral diffusion-weighted imaging at 7T using expanded encoding with compressed sensing
Authors:
Gabriel Varela-Mattatall,
Paul I. Dubovan,
Tales Santini,
Kyle M. Gilbert,
Ravi S. Menon,
Corey A. Baron
Abstract:
Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stopping used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-…
▽ More
Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stopping used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-wavelet regularization, or equivalently compressed sensing (CS), combined with expanded encoding improves trade-offs between spatial resolution, readout time and SNR for single-shot spiral diffusion-weighted imaging at 7T. The reconstructions were performed using our open-source GPU-enabled reconstruction toolbox, MatMRI, that allows inclusion of the different components of the expanded encoding model, with or without CS. Methods: In vivo accelerated single-shot spirals were acquired with five acceleration factors (2-6) and three in-plane spatial resolutions (1.5, 1.3, and 1.1 mm). From the in vivo reconstructions, we estimated diffusion tensors and computed fractional anisotropy maps. Then, simulations were used to quantitatively investigate and validate the impact of CS-based regularization on image quality when compared to a known ground truth. Results: In vivo reconstructions revealed improved image quality with retainment of small features when CS was used. Simulations showed that the joint use of the expanded encoding model and CS improves accuracy of image reconstructions (reduced mean-squared error) over the range of acceleration factors investigated. Conclusion: The expanded encoding model and CS regularization are complementary tools for single-shot spiral diffusion MRI, which enables both higher spatial resolutions and higher acceleration factors.
△ Less
Submitted 14 November, 2022;
originally announced November 2022.
-
Model-based determination of the synchronization delay between MRI and trajectory data
Authors:
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Real time monitoring of dynamic magnetic fields has recently become a commercially available option for measuring MRI k-space trajectories and magnetic fields induced by eddy currents in real time. However, for accurate image reconstructions, sub-microsecond synchronization between the MRI and trajectory data is required. In this work, we introduce a new model-based algorithm to automatic…
▽ More
Purpose: Real time monitoring of dynamic magnetic fields has recently become a commercially available option for measuring MRI k-space trajectories and magnetic fields induced by eddy currents in real time. However, for accurate image reconstructions, sub-microsecond synchronization between the MRI and trajectory data is required. In this work, we introduce a new model-based algorithm to automatically perform this synchronization using only the MRI and trajectory data. Methods: The algorithm works by enforcing consistency between the MRI data, trajectory data, and receiver sensitivity profiles by iteratively alternating between convex optimizations for (a) the image and (b) the synchronization delay. A healthy human subject was scanned at 7T using a transmit-receive coil with integrated field probes using both single shot spiral and echo-planar imaging (EPI), and reconstructions with various synchronization delays were compared to the result of the proposed algorithm. The accuracy of the algorithm was also investigated using simulations, where the acquisition delays for simulated acquisitions were determined using the proposed algorithm and compared to the known ground truth. Results: In the in vivo scans, the proposed algorithm minimized artefacts related to synchronization delay for both spiral and EPI acquisitions, and the computation time required was less than 30 seconds. The simulations demonstrated accuracy to within tens of nanoseconds. Conclusion: The proposed algorithm can automatically determine synchronization delays between MRI data and trajectories measured using a field probe system.
△ Less
Submitted 27 May, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Tuned bipolar oscillating gradients for mapping frequency dispersion of diffusion kurtosis in the human brain
Authors:
Kevin B. Borsos,
Desmond H. Y. Tse,
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Oscillating gradient spin echo (OGSE) sequences have demonstrated an ability to probe time-dependent microstructural features, though they often suffer from low SNR due to increased echo times. In this work we introduce frequency tuned bipolar (FTB) gradients as a variation of oscillating gradients with reduced echo time and demonstrate their utility by mapping the frequency dispersion of…
▽ More
Purpose: Oscillating gradient spin echo (OGSE) sequences have demonstrated an ability to probe time-dependent microstructural features, though they often suffer from low SNR due to increased echo times. In this work we introduce frequency tuned bipolar (FTB) gradients as a variation of oscillating gradients with reduced echo time and demonstrate their utility by mapping the frequency dispersion of diffusion kurtosis in human subjects. Methods: An FTB oscillating gradient waveform is presented that provides encoding of 1.5 net oscillation periods thereby reducing the echo time of the acquisition. Simulations were performed to determine an optimal protocol based on SNR of kurtosis frequency dispersion - defined as the difference in kurtosis between pulsed and oscillating gradient acquisitions. Healthy human subjects were scanned at 7T using pulsed gradient and an optimized 23 Hz FTB protocol, which featured a maximum b-value of 2500 s/mm2. In addition, to directly compare existing methods, measurements using traditional cosine OGSE were also acquired. Results: FTB oscillating gradients demonstrated equivalent frequency dependent diffusion measurements compared to cosine modulated OGSE while enabling a significant reduction in echo time. Optimization and in vivo results suggest FTB gradients provide increased SNR of kurtosis dispersion maps compared to traditional cosine OGSE. The optimized FTB gradient protocol demonstrated consistent reductions in apparent kurtosis values and increased diffusivity in generated frequency dispersion maps. Conclusion: This work presents an alternative to traditional cosine OGSE sequences enabling more time efficient acquisitions of frequency dependent diffusion quantities as demonstrated through in vivo kurtosis frequency dispersion maps.
△ Less
Submitted 15 October, 2022; v1 submitted 28 September, 2021;
originally announced September 2021.
-
Least Squares Optimal Density Compensation for the Gridding Non-uniform Discrete Fourier Transform
Authors:
Nicholas Dwork,
Daniel O'Connor,
Ethan M. I. Johnson,
Corey A. Baron,
Jeremy W. Gordon,
John M. Pauly,
Peder E. Z. Larson
Abstract:
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measu…
▽ More
The Gridding algorithm has shown great utility for reconstructing images from non-uniformly spaced samples in the Fourier domain in several imaging modalities. Due to the non-uniform spacing, some correction for the variable density of the samples must be made. Existing methods for generating density compensation values are either sub-optimal or only consider a finite set of points (a set of measure 0) in the optimization. This manuscript presents the first density compensation algorithm for a general trajectory that takes into account the point spread function over a set of non-zero measure. We show that the images reconstructed with Gridding using the density compensation values of this method are of superior quality when compared to density compensation weights determined in other ways. Results are shown with a numerical phantom and with magnetic resonance images of the abdomen and the knee.
△ Less
Submitted 16 June, 2021; v1 submitted 11 June, 2021;
originally announced June 2021.
-
BMART-Enabled Field-Map Combination of Projection-Reconstruction Phase-Cycled SSFP Cardiac Cine for Banding and Flow-Artifact Reduction
Authors:
Anjali Datta,
Dwight G Nishimura,
Corey A Baron
Abstract:
Purpose: To develop a method for banding-free bSSFP cardiac cine with substantially reduced flow artifacts.
Methods: A projection-reconstruction (PR) trajectory is proposed for a frequency-modulated cine sequence, facilitating reconstruction of three phase cycles and a field-map time series from a short, breath-held scan. Data is also acquired during the gradient rewinders to enable generation o…
▽ More
Purpose: To develop a method for banding-free bSSFP cardiac cine with substantially reduced flow artifacts.
Methods: A projection-reconstruction (PR) trajectory is proposed for a frequency-modulated cine sequence, facilitating reconstruction of three phase cycles and a field-map time series from a short, breath-held scan. Data is also acquired during the gradient rewinders to enable generation of field maps using BMART, B$_0$ mapping using rewinding trajectories, where the rewind data forms the second TE image for calculating the field map. A field-map-based combination method is developed which weights the phase-cycle component images to include only passband signal in the final cine images, and exclude stopband and near-band flow artifacts.
Results: The weights derived from the BMART-generated field maps mask out banding and near-band flow artifacts in and around the heart. Therefore, the field-map-based phase-cycle combination, which is facilitated by the PR acquisition with BMART, results in more homogeneous blood pools and reduced hyperintense regions than root-sum-of-squares.
Conclusion: With the proposed techniques, using a non-Cartesian trajectory for a frequency-modulated cine sequence enables flow-artifact-reduced banding-free cardiac imaging within a short breath-hold.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Characterization and Correction of Time-Varying Eddy Currents for Diffusion MRI
Authors:
Jake J. Valsamis,
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Diffusion MRI (dMRI) suffers from eddy currents induced by strong diffusion gradients, which introduce artefacts that can impair subsequent diffusion metric analysis. Existing retrospective correction techniques that correct for diffusion gradient induced eddy currents do not account for eddy current decay, which is generally effective for traditional Pulsed Gradient Spin Echo (PGSE) diff…
▽ More
Purpose: Diffusion MRI (dMRI) suffers from eddy currents induced by strong diffusion gradients, which introduce artefacts that can impair subsequent diffusion metric analysis. Existing retrospective correction techniques that correct for diffusion gradient induced eddy currents do not account for eddy current decay, which is generally effective for traditional Pulsed Gradient Spin Echo (PGSE) diffusion encoding. However, these techniques do not necessarily apply to advanced forms of dMRI that require substantial gradient slewing, such as Oscillating Gradient Spin Echo (OGSE).
Methods: An in-house algorithm (TVEDDY), that for the first time retrospectively models eddy current decay, was tested on PGSE and OGSE brain images acquired at 7T. Correction performance was compared to conventional correction methods by evaluating the mean-squared error (MSE) between diffusion-weighted images acquired with opposite polarity diffusion gradients. As a ground truth comparison, images were corrected using field dynamics up to third order in space measured using a field monitoring system.
Results: Time-varying eddy currents were observed for OGSE, which introduced blurring that was not reduced using the traditional approach but was diminished considerably with TVEDDY and model-based reconstruction. No MSE difference was observed between the conventional approach and TVEDDY for PGSE, but for OGSE TVEDDY resulted in significantly lower MSE than the conventional approach. The field-monitoring-informed model-based reconstruction had the lowest MSE for both PGSE and OGSE.
Conclusion: This work establishes that it is possible to estimate time-varying eddy currents from the diffusion data itself, which provides substantial image quality improvements for gradient-intensive dMRI acquisitions like OGSE.
△ Less
Submitted 14 July, 2021; v1 submitted 31 January, 2021;
originally announced February 2021.
-
High-Resolution, Respiratory-Resolved Coronary MRA Using a Phyllotaxis-Reordered Variable-Density 3D Cones Trajectory
Authors:
Srivathsan P. Koundinyan,
Corey A. Baron,
Mario O. Malave,
Frank Ong,
Nii Okai Addy,
Joseph Y. Cheng,
Phillip C. Yang,
Bob S. Hu,
Dwight G. Nishimura
Abstract:
Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory.
Methods: To achieve respiratory-resolved 0.98 mm resolution images in a clinically relevant scan time, we undersample the imaging data with a variable-density 3D cones trajectory. For retrospective motion compensation, tran…
▽ More
Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory.
Methods: To achieve respiratory-resolved 0.98 mm resolution images in a clinically relevant scan time, we undersample the imaging data with a variable-density 3D cones trajectory. For retrospective motion compensation, translational estimates from 3D image-based navigators (3D iNAVs) are used to bin the imaging data into four phases from end-expiration to end-inspiration. To ensure pseudo-random undersampling within each respiratory phase, we devise a phyllotaxis readout ordering scheme mindful of eddy current artifacts in steady state free precession imaging. Following binning, residual 3D translational motion within each phase is computed using the 3D iNAVs and corrected for in the imaging data. The noise-like aliasing characteristic of the combined phyllotaxis and cones sampling pattern is leveraged in a compressed sensing reconstruction with spatial and temporal regularization to reduce aliasing in each of the respiratory phases.
Results: In a volunteer and 5 patients, respiratory motion compensation using the proposed method yields improved image quality compared to non-respiratory-resolved approaches with no motion correction and with 3D translational correction. Qualitative assessment by two cardiologists indicates the superior sharpness of coronary segments reconstructed with the proposed method (P < 0.01).
Conclusion: The proposed method better mitigates motion artifacts in free-breathing, high-resolution coronary angiography exams compared to translational correction.
△ Less
Submitted 27 October, 2019;
originally announced October 2019.
-
Unraveling the Effect of Spatial Resolution and Scan Acceleration on 3D Image-Based Navigators for Respiratory Motion Tracking in Coronary MR Angiography
Authors:
Srivathsan P. Koundinyan,
Joseph Y. Cheng,
Mario O. Malave,
Phillip C. Yang,
Bob S. Hu,
Dwight G. Nishimura,
Corey A. Baron
Abstract:
Purpose: To study the accuracy of motion information extracted from beat-to-beat 3D image-based navigators (3D iNAVs) collected using a variable-density cones trajectory with different combinations of spatial resolutions and scan acceleration factors.
Methods: Fully sampled, breath-held 4.4 mm 3D iNAV datasets for six respiratory phases are acquired in a volunteer. Ground truth translational and…
▽ More
Purpose: To study the accuracy of motion information extracted from beat-to-beat 3D image-based navigators (3D iNAVs) collected using a variable-density cones trajectory with different combinations of spatial resolutions and scan acceleration factors.
Methods: Fully sampled, breath-held 4.4 mm 3D iNAV datasets for six respiratory phases are acquired in a volunteer. Ground truth translational and nonrigid motion information is derived from these datasets. Subsequently, the motion estimates from synthesized undersampled 3D iNAVs with isotropic spatial resolutions of 4.4 mm (acceleration factor = 10.9), 5.4 mm (acceleration factor = 7.2), 6.4 mm (acceleration factor = 4.2), and 7.8 mm (acceleration factor = 2.9) are assessed against the ground truth information. The undersampled 3D iNAV configuration with the highest accuracy motion estimates in simulation is then compared with the originally proposed 4.4 mm undersampled 3D iNAV in six volunteer studies.
Results: The simulations indicate that for navigators beyond certain scan acceleration factors, the accuracy of motion estimates is compromised due to errors from residual aliasing and blurring/smoothening effects following compressed sensing reconstruction. The 6.4 mm 3D iNAV achieves an acceptable spatial resolution with a small acceleration factor, resulting in the highest accuracy motion information among all assessed undersampled 3D iNAVs. Reader scores for six volunteer studies demonstrate superior coronary vessel sharpness when applying an autofocusing nonrigid correction technique using the 6.4 mm 3D iNAVs in place of 4.4 mm 3D iNAVs.
Conclusion: Undersampled 6.4 mm 3D iNAVs enable motion tracking with improved accuracy relative to previously proposed undersampled 4.4 mm 3D iNAVs.
△ Less
Submitted 27 October, 2019;
originally announced October 2019.
-
Diffusion Dispersion Imaging: Mapping OGSE Frequency Dependence in the Human Brain
Authors:
Aidin Arbabi,
Jason Kai,
Ali R Khan,
Corey A Baron
Abstract:
Purpose: Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues via the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human brain have been limited and have suffered from low contrast between different frequencie…
▽ More
Purpose: Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues via the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human brain have been limited and have suffered from low contrast between different frequencies, long scan times and a limited exploration of the nature of the ADC dependence on frequency. Methods: Multiple frequency OGSE acquisitions were acquired in healthy subjects at 7 T to explore the power-law frequency dependence of ADC, the "diffusion dispersion". Further, a method for optimizing the estimation of the ADC difference between different OGSE frequencies was developed, which enabled the design of a highly efficient protocol for mapping diffusion dispersion. Results: For the first time, evidence of a linear dependence of ADC on the square root of frequency in healthy human white matter was obtained. Using the optimized protocol, high quality, full-brain maps of apparent diffusion dispersion rate were also demonstrated at an isotropic resolution of 2 mm in a scan time of 6 minutes. Conclusion: This work sheds light on the nature of diffusion dispersion in the healthy human brain and introduces full brain diffusion dispersion mapping at clinically relevant scan times. These advances may lead to new biomarkers of pathology or improved microstructural modelling.
△ Less
Submitted 24 September, 2019; v1 submitted 16 April, 2019;
originally announced April 2019.