Exploring Offline Pileup Correction to Improve the Accuracy of Microdosimetric Characterization in Clinical Ion Beams
Authors:
Matthias Knopf,
Sandra Barna,
Daniel Radmanovac,
Thomas Bergauer,
Albert Hirtl,
Giulio Magrin
Abstract:
Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorp…
▽ More
Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology, radiation protection and radiotherapy. Microdosimetric pulse height spectra are usually measured using an ionization detector in a pulsed readout mode. This incorporates a charge-sensitive amplifier followed by a shaping network. At high particle rates, the pileup of multiple pulses leads to distortions in the recorded spectra. Especially for gas-based detectors, this is a significant issue, that can be reduced by using solid-state detectors with smaller cross-sectional areas and faster readout speeds. At particle rates typical for ion therapy, however, such devices will also experience pileup. Mitigation techniques often focus on avoiding pileup altogether, while post-processing approaches are rarely investigated. This work explores pileup effects in microdosimetric measurements and presents a stochastic resampling algorithm, allowing for offline simulation and correction of spectra. Initially it was developed for measuring neutron spectra with tissue equivalent proportional counters and is adapted for the use with solid-state microdosimeters in a clinical radiotherapy setting. The algorithm was tested on data acquired with solid-state microdosimeters at the MedAustron ion therapy facility. The successful simulation and reduction of pileup counts is achieved by establishing of a limited number of parameters for a given setup. The presented results illustrate the potential of offline correction methods in situations where a direct pileup-free measurement is currently not practicable.
△ Less
Submitted 15 April, 2025; v1 submitted 16 December, 2024;
originally announced December 2024.
-
High-count-rate Particle Tracking in Proton and Carbon Radiotherapy with Timepix2 Operated in Ultra-Short Acquisition Time
Authors:
C. Oancea,
A. Resch,
S. Barna,
G. Magrin,
L. Grevillot,
D. Hladik,
L. Marek,
J. Jakubek,
C. Granja
Abstract:
This work investigates the operational acquisition time limits of Timepix3 and Timepix2 detectors operated in frame mode for high-count rate of high deposited energy transfer particles. Measurements were performed using alpha particles from a 241Am laboratory source and proton and carbon ion beams from a synchrotron accelerator. The particle count rate upper limit is determined by overlapping per-…
▽ More
This work investigates the operational acquisition time limits of Timepix3 and Timepix2 detectors operated in frame mode for high-count rate of high deposited energy transfer particles. Measurements were performed using alpha particles from a 241Am laboratory source and proton and carbon ion beams from a synchrotron accelerator. The particle count rate upper limit is determined by overlapping per-pixel particle signals, identifiable by the hits per pixel counter > 2, indicating the need to decrease acquisition time. On the other hand, the lower limit is the time required to collect the particle deposited charge while maintaining spectral properties. Different acquisition times were evaluated for an AdvaPIX Timepix3 detector (500 um Silicon sensor) with standard per-pixel DAC settings and a Minipix Timepix2 detector (300 um Silicon sensor) with standard and customized settings the pulse shaping parameter and threshold. For AdvaPIX Timepix3, spectra remained accurate down to 100 us frame acquisition time; at 10 us, loss of collected charge occurred, suggesting either avoiding this acquisition time or applying a correction. Timepix2 allowed acquisition times down to 100 ns for single particle track measurements even for high energy loss, enabled by a new Timepix2 feature delaying shutter closure until full particle charge collection. This work represents the first measurement utilizing Timepix-chips pixel detectors in an accelerator beam of clinical energy and intensity without the need to decrease the beam current. This is made possible by exploiting the short shutter feature in Timepix2 and a customized per-pixel energy calibration of the Timepix2 detector with a larger discharging signal value which allowed for a shorter time-over-threshold (ToT) signal. These customized settings extend the operation of the pixel detectors to higher event rates up to 10^9 particles/cm^2/s.
△ Less
Submitted 26 September, 2024;
originally announced September 2024.
-
Microdosimetry of a clinical carbon-ion pencil beam at MedAustron -- Part 1: experimental characterization
Authors:
Cynthia Meouchi,
Sandra Barna,
Anatoly Rosenfeld,
Linh T. Tran,
Hugo Palmans,
Giulio Magrin
Abstract:
This paper characterizes the microdosimetric spectra of a single-energy carbon-ion pencil beam at MedAustron using a miniature solid-state silicon microdosimeter to estimate the impact of the lateral distribution of the different fragments on the microdosimetric spectra. The microdosimeter was fixed at one depth and then laterally moved away from the central beam axis in steps of approximately 2 m…
▽ More
This paper characterizes the microdosimetric spectra of a single-energy carbon-ion pencil beam at MedAustron using a miniature solid-state silicon microdosimeter to estimate the impact of the lateral distribution of the different fragments on the microdosimetric spectra. The microdosimeter was fixed at one depth and then laterally moved away from the central beam axis in steps of approximately 2 mm. The measurements were taken in both horizontal and vertical direction in a water phantom at different depths. In a position on the distal dose fall-off beyond the Bragg peak, the frequency-mean and the dose-mean lineal energies were derived using either the entire range of y-values, or a sub-range of y values, presumingly corresponding mainly to contributions from primary particles. The measured microdosimetric spectra do not exhibit a significant change up to 4 mm away from the beam central axis. For lateral positions more than 4 mm away from the central axis, the relative contribution of the lower lineal-energy part of the spectrum increases with lateral distance due to the increased partial dose from secondary fragments. The average values yF and yD are almost constant for each partial contribution. However, when all particles are considered together, the average value of yF and yD varies with distance from the axis due to the changing dose fractions of these two components varying by 30 % and 10 % respectively up to the most off axis vertical position. Characteristic features in the microdosimetric spectra providing strong indications of the presence of helium and boron fragments have been observed downstream of the distal part of the Bragg peak. We were able to investigate the radiation quality as function of off-axis position. These measurements emphasize variation of the radiation quality within the beam and this has implications in terms of relative biological effectiveness.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.