-
A Silicon Microstrip Detector for Power-Limited and Large Sensitive Area Applications
Authors:
Dexing Miao,
Zijun Xu,
Zhiyu Xiang,
Pingcheng Liu,
Giovanni Ambrosi,
Mattia Barbanera,
Mengke Cai,
Xudong Cai,
Hsin-Yi Chou,
Matteo Duranti,
Valerio Formato,
Maria Ionica,
Yaozu Jiang,
Liangchenglong Jin,
Vladimir Koutsenko,
Qinze Li,
Cong Liu,
Xingjian Lv,
Alberto Oliva,
Wenxi Peng,
Rui Qiao,
Gianluigi Silvestre,
Zibing Wu,
Xuhao Yuan,
Hongyu Zhang
, et al. (2 additional authors not shown)
Abstract:
A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors inserted between two aluminum readout strips. Beam test measurements with the single sensor confirmed that this configuration achieves a total detection efficiency of…
▽ More
A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors inserted between two aluminum readout strips. Beam test measurements with the single sensor confirmed that this configuration achieves a total detection efficiency of $99.8 \, \%$ and spatial resolution $7.6 \, \mathrm{μm}$ for MIPs. A double-$η$ algorithm was developed to optimize hit position reconstruction for this SSD. The design can be adapted for large area silicon detectors.
△ Less
Submitted 28 May, 2025;
originally announced May 2025.
-
Performance assessment of the HERD calorimeter with a photo-diode read-out system for high-energy electron beams
Authors:
O. Adriani,
G. Ambrosi,
M. Antonelli,
Y. Bai,
X. Bai,
T. Bao,
M. Barbanera,
E. Berti,
P. Betti,
G. Bigongiari,
M. Bongi,
V. Bonvicini,
S. Bottai,
I. Cagnoli,
W. Cao,
J. Casaus,
D. Cerasole,
Z. Chen,
X. Cui,
R. D'Alessandro,
L. Di Venere,
C. Diaz,
Y. Dong,
S. Detti,
M. Duranti
, et al. (41 additional authors not shown)
Abstract:
The measurement of cosmic rays at energies exceeding 100 TeV per nucleon is crucial for enhancing the understanding of high-energy particle propagation and acceleration models in the Galaxy. HERD is a space-borne calorimetric experiment that aims to extend the current direct measurements of cosmic rays to unexplored energies. The payload is scheduled to be installed on the Chinese Space Station in…
▽ More
The measurement of cosmic rays at energies exceeding 100 TeV per nucleon is crucial for enhancing the understanding of high-energy particle propagation and acceleration models in the Galaxy. HERD is a space-borne calorimetric experiment that aims to extend the current direct measurements of cosmic rays to unexplored energies. The payload is scheduled to be installed on the Chinese Space Station in 2027. The primary peculiarity of the instrument is its capability to measure particles coming from all directions, with the main detector being a deep, homogeneous, 3D calorimeter. The active elements are read out using two independent systems: one based on wavelength shifter fibers coupled to CMOS cameras, and the other based on photo-diodes read-out with custom front-end electronics. A large calorimeter prototype was tested in 2023 during an extensive beam test campaign at CERN. In this paper, the performance of the calorimeter for high-energy electron beams, as obtained from the photo-diode system data, is presented. The prototype demonstrated excellent performance, e.g., an energy resolution better than 1% for electrons at 250 GeV. A comparison between beam test data and Monte Carlo simulation data is also presented.
△ Less
Submitted 4 October, 2024;
originally announced October 2024.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Light Detection System and Time Resolution of the NA62 RICH
Authors:
G. Anzivino,
M. Barbanera,
A. Bizzeti,
F. Brizioli,
F. Bucci,
A. Cassese,
P. Cenci,
R. Ciaranfi,
V. Duk,
J. Engelfried,
N. Estrada-Tristan,
E. Iacopini,
E. Imbergamo,
G. Latino,
M. Lenti,
R. Lollini,
P. Lubrano,
R. Piandani,
M. Pepe,
M. Piccini,
A. Sergi,
M. Turisini,
R. Volpe
Abstract:
A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion sample by a factor of 100 in the momentum range between 15 and 35 GeV/c. Cherenkov light is collected by 1952 photomultipliers placed at the upstream end. In this paper the characterization of the photomultipliers and the dedicated Frontend and Data Acquisition electronics are described, the time resolutio…
▽ More
A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion sample by a factor of 100 in the momentum range between 15 and 35 GeV/c. Cherenkov light is collected by 1952 photomultipliers placed at the upstream end. In this paper the characterization of the photomultipliers and the dedicated Frontend and Data Acquisition electronics are described, the time resolution and the light detection efficiency measurement are presented.
△ Less
Submitted 16 September, 2020;
originally announced September 2020.
-
The integrated low-level trigger and readout system of the CERN NA62 experiment
Authors:
R. Ammendola,
B. Angelucci,
M. Barbanera,
A. Biagioni,
V. Cerny,
B. Checcucci,
R. Fantechi,
F. Gonnella,
M. Koval,
M. Krivda,
G. Lamanna,
M. Lupi,
A. Lonardo,
A. Papi,
C. Parkinson,
E. Pedreschi,
P. Petrov,
R. Piandani,
J. Pinzino,
L. Pontisso,
M. Raggi,
D. Soldi,
M. S. Sozzi,
F. Spinella,
S. Venditti
, et al. (1 additional authors not shown)
Abstract:
The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowi…
▽ More
The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowing full flexibility on this scale, allowing in principle any information available from the detector to be used for triggering. The design concept, implementation and performances from the first years of running are illustrated.
△ Less
Submitted 25 March, 2019;
originally announced March 2019.
-
Precise Mirror Alignment and Basic Performance of the RICH Detector of the NA62 Experiment at CERN
Authors:
G. Anzivino,
M. Barbanera,
A. Bizzeti,
F. Brizioli,
F. Bucci,
A. Cassese,
P. Cenci,
B. Checcucci,
R. Ciaranfi,
V. Duk,
J. Engelfried,
N. Estrada-Tristan,
E. Iacopini,
E. Imbergamo,
G. Latino,
M. Lenti,
R. Lollini,
M. Pepe,
M. Piccini,
R. Volpe
Abstract:
The Ring Imaging Cherenkov detector is crucial for the identification of charged particles in the NA62 experiment at the CERN SPS. The detector commissioning was completed in 2016 by the precise alignment of mirrors using reconstructed tracks. The alignment procedure and measurement of the basic performance are described. Ring radius resolution, ring centre resolution, single hit resolution and me…
▽ More
The Ring Imaging Cherenkov detector is crucial for the identification of charged particles in the NA62 experiment at the CERN SPS. The detector commissioning was completed in 2016 by the precise alignment of mirrors using reconstructed tracks. The alignment procedure and measurement of the basic performance are described. Ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring are evaluated for positron tracks. The contribution of the residual mirror misalignment to the performance is calculated.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Search for $K^{+}\rightarrowπ^{+}ν\overlineν$ at NA62
Authors:
NA62 Collaboration,
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
R. Ammendola,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
M. Barbanera,
J. Bendotti,
A. Biagioni,
L. Bician,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Boretto,
M. Bragadireanu,
D. Britton
, et al. (227 additional authors not shown)
Abstract:
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired,…
▽ More
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired, in view of the final measurement, will be presented.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.