-
Nanobeacon: A time calibration device for the KM3NeT neutrino telescope
Authors:
S. Aiello,
A. Albert,
M. Alshamsi,
S. Alves Garre,
Z. Aly,
A. Ambrosone,
F. Ameli,
M. Andre,
G. Androulakis,
M. Anghinolfi,
M. Anguita,
M. Ardid,
S. Ardid,
J. Aublin,
C. Bagatelas,
B. Baret,
S. Basegmez du Pree,
M. Bendahman,
F. Benfenati,
E. Berbee,
A. M. van den Berg,
V. Bertine,
S. Biagi,
M. Boettcher,
M. Bou Cabo
, et al. (216 additional authors not shown)
Abstract:
The KM3NeT Collaboration is currently constructing a multi-site high-energy neutrino telescope in the Mediterranean Sea consisting of matrices of pressure-resistant glass spheres, each holding a set of 31 small-area photomultipliers. The main goals of the telescope are the observation of neutrino sources in the Universe and the measurement of the neutrino oscillation parameters with atmospheric ne…
▽ More
The KM3NeT Collaboration is currently constructing a multi-site high-energy neutrino telescope in the Mediterranean Sea consisting of matrices of pressure-resistant glass spheres, each holding a set of 31 small-area photomultipliers. The main goals of the telescope are the observation of neutrino sources in the Universe and the measurement of the neutrino oscillation parameters with atmospheric neutrinos. Both extraterrestrial and atmospheric neutrinos are detected through the Cherenkov light induced in seawater by charged particles produced in neutrino interactions in the surrounding medium. A relative time synchronization between photomultipliers of the order of 1 ns is needed to guarantee the required angular resolution of the detector. Due to the large detector volumes to be instrumented by KM3NeT, a cost reduction of the different systems is a priority. To this end, the inexpensive Nanobeacon has been designed and developed by the KM3NeT Collaboration to be used for detector time-calibration studies. At present, more than 600 Nanobeacons have been already produced. The characterization of the optical pulse and the wavelength emission profile of the devices are critical for the time calibration. In this paper, the main features of the Nanobeacon design, production and operation, together with the main properties of the light pulse generated are described.
△ Less
Submitted 30 October, 2021;
originally announced November 2021.
-
Event reconstruction for KM3NeT/ORCA using convolutional neural networks
Authors:
Sebastiano Aiello,
Arnauld Albert,
Sergio Alves Garre,
Zineb Aly,
Fabrizio Ameli,
Michel Andre,
Giorgos Androulakis,
Marco Anghinolfi,
Mancia Anguita,
Gisela Anton,
Miquel Ardid,
Julien Aublin,
Christos Bagatelas,
Giancarlo Barbarino,
Bruny Baret,
Suzan Basegmez du Pree,
Meriem Bendahman,
Edward Berbee,
Vincent Bertin,
Simone Biagi,
Andrea Biagioni,
Matthias Bissinger,
Markus Boettcher,
Jihad Boumaaza,
Mohammed Bouta
, et al. (207 additional authors not shown)
Abstract:
The KM3NeT research infrastructure is currently under construction at two locations in the Mediterranean Sea. The KM3NeT/ORCA water-Cherenkov neutrino detector off the French coast will instrument several megatons of seawater with photosensors. Its main objective is the determination of the neutrino mass ordering. This work aims at demonstrating the general applicability of deep convolutional neur…
▽ More
The KM3NeT research infrastructure is currently under construction at two locations in the Mediterranean Sea. The KM3NeT/ORCA water-Cherenkov neutrino detector off the French coast will instrument several megatons of seawater with photosensors. Its main objective is the determination of the neutrino mass ordering. This work aims at demonstrating the general applicability of deep convolutional neural networks to neutrino telescopes, using simulated datasets for the KM3NeT/ORCA detector as an example. To this end, the networks are employed to achieve reconstruction and classification tasks that constitute an alternative to the analysis pipeline presented for KM3NeT/ORCA in the KM3NeT Letter of Intent. They are used to infer event reconstruction estimates for the energy, the direction, and the interaction point of incident neutrinos. The spatial distribution of Cherenkov light generated by charged particles induced in neutrino interactions is classified as shower- or track-like, and the main background processes associated with the detection of atmospheric neutrinos are recognized. Performance comparisons to machine-learning classification and maximum-likelihood reconstruction algorithms previously developed for KM3NeT/ORCA are provided. It is shown that this application of deep convolutional neural networks to simulated datasets for a large-volume neutrino telescope yields competitive reconstruction results and performance improvements with respect to classical approaches.
△ Less
Submitted 17 April, 2020;
originally announced April 2020.
-
Dependence of atmospheric muon flux on seawater depth measured with the first KM3NeT detection units
Authors:
KM3NeT Collaboration,
M. Ageron,
S. Aiello,
F. Ameli,
M. Andre,
G. Androulakis,
M. Anghinolfi,
G. Anton,
M. Ardid,
J. Aublin,
C. Bagatelas,
G. Barbarino,
B. Baret,
S. Basegmez du Pree,
A. Belias,
E. Berbee,
A. M. van den Berg,
V. Bertin,
V. van Beveren,
S. Biagi,
A. Biagioni,
S. Bianucci,
M. Billault,
M. Bissinger,
R. de Boer
, et al. (240 additional authors not shown)
Abstract:
KM3NeT is a research infrastructure located in the Mediterranean Sea, that will consist of two deep-sea Cherenkov neutrino detectors. With one detector (ARCA), the KM3NeT Collaboration aims at identifying and studying TeV-PeV astrophysical neutrino sources. With the other detector (ORCA), the neutrino mass ordering will be determined by studying GeV-scale atmospheric neutrino oscillations. The fir…
▽ More
KM3NeT is a research infrastructure located in the Mediterranean Sea, that will consist of two deep-sea Cherenkov neutrino detectors. With one detector (ARCA), the KM3NeT Collaboration aims at identifying and studying TeV-PeV astrophysical neutrino sources. With the other detector (ORCA), the neutrino mass ordering will be determined by studying GeV-scale atmospheric neutrino oscillations. The first KM3NeT detection units were deployed at the Italian and French sites between 2015 and 2017. In this paper, a description of the detector is presented, together with a summary of the procedures used to calibrate the detector in-situ. Finally, the measurement of the atmospheric muon flux between 2232-3386 m seawater depth is obtained.
△ Less
Submitted 4 February, 2020; v1 submitted 6 June, 2019;
originally announced June 2019.